prEN ISO 14159
(Main)Safety of machinery - General requirements for hygienic design (ISO/DIS 14159:2026)
- Abstract
This International Standard specifies hygiene requirements of machines and provides information for the intended use to be provided by the manufacturer. It applies to all types of machines and associated equipment used in applications where hygiene risks to the consumer of the product can occur.
This International Standard does not cover requirements relative to the uncontrolled egress of microbiological agents from the machine.
- Status
- Not Published
- Publication Date
- 02-Jan-2028
- Technical Committee
- CEN/TC 114 - Safety of machinery
- Current Stage
- 4060 - Closure of enquiry - Enquiry
- Start Date
- 01-Oct-2026
- Due Date
- 01-Oct-2026
- Completion Date
- 01-Oct-2026
prEN ISO 14159 is a Type B standard from CEN/ISO for the hygienic design of machinery and associated equipment. It sets general hygiene requirements and the information for use that the manufacturer should provide for machines used where product contamination could affect the consumer of the product. It does not cover requirements for the uncontrolled egress of microbiological agents from the machine.
What does prEN ISO 14159 specify?
prEN ISO 14159 specifies general requirements for hygienic design, together with instructions for use, for all types of machines and associated equipment used in applications where hygiene risks to the consumer can occur. In practice, it is the general reference for deciding how a machine should be shaped, finished, cleaned, verified and documented so that product contamination is controlled.
The document is organized into these main clauses:
- Clause 1 Scope
- Clause 2 Normative references
- Clause 3 Terms and definitions
- Clause 4 List of significant hazards
- Clause 5 Hygiene requirements and hygiene measures
- Clause 6 Hygiene risk reduction
- Clause 7 Verification of hygiene measures and test methods
- Clause 8 Instruction handbook, maintenance and cleaning
It also includes three informative annexes.
| Annex | What it covers |
|---|---|
| Annex A | Examples of potential risks and possible solutions, with figures showing good and poor hygienic design |
| Annex B | Examples of hygiene hazards, organized as a table of hazard sources and hazardous situations |
| Annex ZA | Relationship between this European Standard and the essential requirements of Regulation (EU) 2023/1230 |
What are the key requirements of prEN ISO 14159?
The core of prEN ISO 14159 is an iterative risk-based process. The standard asks the manufacturer to identify hygiene hazards, assess the hygiene risk, reduce it in steps, verify the result, and describe any residual risks and cleaning or maintenance measures in the instructions for use.
Risk assessment and hazard identification
Clause 5 links hygienic design to ISO 12100 and requires the risk assessment to cover the product area, splash area and non-product areas. The assessment starts with the limits of the machine, including intended use, foreseeable misuse, operating modes, user groups, cleaning intervals, maintenance intervals, product type and the processing stage. In practice, this means the designer has to think about how the machine will actually be used, cleaned and maintained, not only how it works in production.
Clause 4 lists significant hazards from microbiological, chemical and physical causes, and also from malfunctions of equipment such as filters, cleaning systems, pasteurizing or sterilizing systems, sterilized air or protective gas flow. This matters because the hygienic design has to address contamination risks from the product, the environment and the machine itself.
The hygiene risk reduction sequence
Clause 5.2.4 sets the reduction sequence:
- remove the hazard or reduce it by hygienic design
- use technical measures if needed
- use cleaning and/or disinfection measures if needed
- use additional measures such as personnel hygiene or training
The standard also says that hygiene measures can create safety risks, so the hygiene and safety assessments have to be considered together. In practice, if a design change improves cleanability but reduces safety, the manufacturer has to resolve both risks and keep the highest level of protection for the more severe risk.
Materials and surfaces
Clause 6.1.1 requires materials, surface finishes and coatings to be suitable for the intended use. Product contact surfaces have to be corrosion resistant, non-toxic, non-absorbent where possible, and not transfer odors, colors or taint to the product. Non-product contact surfaces, including splash areas, also need to resist corrosion and not contaminate the product.
This matters when selecting stainless steel, plastics, coatings, seals and repair methods. The material choice must fit the product, the cleaning chemicals and any disinfection, pasteurization or sterilization conditions.
Product area design
Clause 6.1.2 focuses on the product area. Surfaces should avoid pits, folds, cracks and crevices, and liquid-handling surfaces should be self-draining or drainable. Dead spaces should be avoided, joints should be hygienically sealed and flush, and fasteners in the product area should be kept to the technically necessary minimum.
The same clause also covers seals, gaskets, O-rings, shafts, bearings, sensors, sampling devices, covers and process intrusions. In practice, these are the places where soil, moisture and microorganisms can collect, so the standard pushes the designer toward easy cleaning, inspection and drainage.
Splash area and non-product area
Clause 6.1.3 says splash areas may have less stringent design criteria than the product area, but they still have to prevent moisture retention and soil harborage and allow cleaning, inspection, servicing and maintenance. Clause 6.1.4 gives separate requirements for non-product areas, including insulation, supports, product contamination by machine fluids and ventilation openings.
This is important because not every part of a machine needs the same level of hygienic detailing, but every area still has to be assessed for its own contamination risk.
Verification and instructions
Clause 7 allows verification by examination of specifications and drawings, inspection of the fabricated machine, and practical tests using validated methods. Clause 8 requires the instruction handbook to follow ISO 20607 and/or ISO 12100 and to cover installation, intended use, hygienic startup measures, maintenance and cleaning, including cleaning after interruptions and re-assembly after dismantling.
For users, this means the standard is not only about design drawings. It also requires the supplier to explain how the machine should be installed, cleaned, maintained and checked so that hygienic integrity is preserved over time.
What terms does prEN ISO 14159 define?
- Associated equipment - equipment linked to a machine that is essential for hygienic product processing, such as fittings, piping and tubing.
- Cleaning in place (CIP) - cleaning a machine or equipment without dismantling parts.
- Product area - surfaces exposed to the product or from which product, drain-off or residues can enter the product.
- Splash area - surfaces that can be hit by product splashes or flow during use, but where the material does not return to the product.
- Non-product area - any area that is neither product area nor splash area.
- Verification - applying methods, procedures and tests to determine compliance.
- Hygienic integrity - the probability that a hygiene-related system performs its required hygiene function under specified conditions for a specified time.
Who uses prEN ISO 14159?
prEN ISO 14159 is used by machinery manufacturers, design engineers, system integrators, and suppliers of associated equipment who need to build hygienic machines from the start. It is also used by quality managers, hygiene specialists, buyers and auditors who review whether a machine design, cleaning concept and instruction handbook are suitable for hygienic applications.
The document is especially relevant for food, feed, beverages, pharmaceuticals, biotechnological products and cosmetics, where contamination control is part of the machine specification. It is useful when writing supplier requirements, carrying out risk assessments, checking cleanability, selecting materials, and defining maintenance and cleaning routines.
What changed in prEN ISO 14159 from the previous edition?
prEN ISO 14159 replaces ISO 14159:2002-04-01 and is described as technically revised. The main changes stated in the document are:
- references were updated
- terms and definitions were updated
- a new Clause 5 on hygiene requirements and hygiene measures was added
- Clause 6 was reorganized around product area, splash area and non-product area
- informative Annexes A and C were replaced by Annex A on potential risks and solutions and Annex B on hygiene hazards
Which standards are used with prEN ISO 14159?
prEN ISO 14159 cites these standards as normative references:
- ISO 12100:2010 - provides the general machinery risk assessment and risk reduction framework used as the base for the hygiene risk process.
- ISO 21920:2022 - supplies surface texture terms, definitions and parameters when specific surface texture requirements are needed.
- ISO 20607:2019 - gives general drafting principles for the instruction handbook.
The document also points readers to:
- EN 1672-2:2022 - additional hygiene and cleanability guidance, especially relevant for food processing machinery.
- ISO/TR 14121-2:2013 - practical guidance and examples for risk assessment methods.
What does the prEN ISO 14159 document contain?
The document contains the full risk-based structure for hygienic design, including the hazard list, the hygiene risk assessment sequence and the area-based design rules for product, splash and non-product areas. It also includes verification options, instruction-handbook requirements, and maintenance and cleaning topics.
Annex A uses figures A.1 to A.16 to show typical hygienic design problems and preferred solutions, such as drainage, dead spaces, joints, fasteners, shafts, bearings, covers, mounting arrangements and sampling devices. Annex B provides a table of example hygiene hazards by source, including materials, product-area design, splash areas, non-product areas, fluids, instrumentation, utilities and pneumatic or hydraulic systems. Annex ZA maps the standard to Regulation (EU) 2023/1230 for European use.
Relations
- Effective Date
- 06-Dec-2023
Get Certified
Connect with accredited certification bodies for this standard
CIS Institut d.o.o.
Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

Kiwa BDA Testing
Building and construction product certification.
Kmetijski inštitut Slovenije
Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.
Sponsored listings
Frequently Asked Questions
prEN ISO 14159 is a draft published by the European Committee for Standardization (CEN). Its full title is "Safety of machinery - General requirements for hygienic design (ISO/DIS 14159:2026)". This standard covers: This International Standard specifies hygiene requirements of machines and provides information for the intended use to be provided by the manufacturer. It applies to all types of machines and associated equipment used in applications where hygiene risks to the consumer of the product can occur. This International Standard does not cover requirements relative to the uncontrolled egress of microbiological agents from the machine.
This International Standard specifies hygiene requirements of machines and provides information for the intended use to be provided by the manufacturer. It applies to all types of machines and associated equipment used in applications where hygiene risks to the consumer of the product can occur. This International Standard does not cover requirements relative to the uncontrolled egress of microbiological agents from the machine.
prEN ISO 14159 is classified under the following ICS (International Classification for Standards) categories: 13.110 - Safety of machinery. The ICS classification helps identify the subject area and facilitates finding related standards.
prEN ISO 14159 has the following relationships with other standards: It is inter standard links to EN ISO 14159:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
prEN ISO 14159 is associated with the following European legislation: EU Directives/Regulations: 2023/1230; Standardization Mandates: M/605. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
prEN ISO 14159 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 3.1 associated equipment
- 3.2 bond
- 3.3 cleaning in place
- 3.4 cleaning
- 3.5 cleanable
- 3.6 consumer
- 3.7 corrosion resistant material
- 3.8 crevice
- 3.9 dead space
- 3.10 disinfection
- 3.11 hygiene
- 3.12 joint
- 3.13 machinery
- 3.14 manual cleaning
- 3.15 micro-organism (relevant)
- 3.16 non-toxic materials
- 3.17 non-absorbent materials
- 3.18 pasteurization
- 3.19 pasteurizable
- 3.20 pest
- 3.21 practical test
- 3.22 product
- 3.23 product area
- 3.24 splash area
- 3.25 non-product area
- 3.26 easily cleanable
- 3.27 readily accessible
- 3.28 readily removable
- 3.29 seal
- 3.30 self-draining
- 3.31 sensors
- 3.32 smooth
- 3.33 soil
- 3.34 sterilization
- 3.35 sterilizability
- 3.36 wet cleaning
- 3.37 dry cleaning
- 3.38 verification
- 3.39 hygienic integrity
- 4 List of significant hazards
- 5 Hygiene requirements and hygiene measures
- 5.1 General
- 5.2 Risk assessment strategy
- 6 Hygiene Risk Reduction
- 7 Verification of hygiene measures and test methods
- 8 Instruction handbook, Maintenance and Cleaning
- 8.1 General
- 8.2 Maintenance and Cleaning
- Annex A
- Annex B
- 2 Hazards arising from the design and manufac-
- 3 Hazards arising from the design of splash
- 4 Design of non-product area
- 6 Hazards arising from machinery fluids — Contamination of non product
- 7 Hazards arising from instrumentation and — Residuals, propagation of
- 8 Hazards arising from unintentional interrup- — Spoilage of accumulated
- 9 Hazards arising from pneumatic systems — Microbial growth due to poor
- Annex ZA
- 8.2 3 ff Not covered
- Bibliography
Introduction
This International Standard is one of a series of standards relating to the safety of machinery (ISO 12100:2010). It is a Type B standard and as such very general. This document does not deal with the hygiene-related risks to operators arising from the use of the machinery.
Hygiene risks are associated with the ability of a machine to prevent product contamination and to be freed from product debris and microorganisms that can compromise the health and safety of persons or domestic animals.
This standard considers machinery and their associated equipment and can be used to provide guidance to the manufacturers of machines, associated equipment and other equipment where hygiene risks to the consumer of the products can occur. Type C standard applicable to specific machines types can implement or modify the requirement of this standard. Furthermore, detailed B standards with requirements for specific sectors of machinery - depending on identified hazards - can be deduced on basis of this general Type B standard.
It is applicable to all machines and associated equipment in applications where hygiene risks to the consumer of the product can occur (e.g.: food, feed,beverages, pharmaceuticals, biotechnological products, cosmetics). Other standards, for example machinery specific Type C standards, may be required to provide guidance for specific types of equipment and/or for specific industry sectors. Furthermore, detailed B standards with requirements for specific sectors of machinery - depending on identified hazards - can be deduced on basis of this general Type B standard.
When no design or safeguarding options are within the state of the art to adequately control both hygiene and safety risks, then one of the risks, or both, would have to be dealt with by residual safeguards, including instructions to the user. The assessment of the respective safety and hygiene risks shall indicate their relative significance, and the highest level of protection (i.e. safeguarding) shall be implemented to deal with the severest risk, and residual safeguards shall be used for the lesser risk. This standard deals in particular with hygiene risks but also considers the possible conflict between safety and hygiene measures. The technical solutions given in this International Standard permit both objectives to be met for those significant and common risks identified as justifying common requirements specified in this International Standard.
oSIST prEN ISO 14159:2026
oSIST prEN ISO 14159:2026 DRAFT International Standard ISO/DIS 14159:2026(en) Safety of machinery — General requirements for hygienic design
1 Scope
This International Standard specifies general requirements for the hygienic design of machinery and associated equipment as well as instructions for use. It applies to all types of machines and associated equipment used in applications where hygiene risks to the consumer of the product can occur. This International Standard does not cover requirements relative to the egress of microbiological agents from the machine.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 12100:2010, Safety of machinery — General principles for design — Risk assessment and risk reduction Reduction ISO 21920:2022, Geometrical product specifications (GPS) – Surface texture: Profile- Part 2: Terms, definitions and surface texture parameters ISO 20607:2019, Safety of machinery — Instruction handbook — General drafting principles For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at https:// www .electropedia .org/
3.1 associated equipment
all equipment associated with a machine, not defined as machinery (3.13), that is essential to the functioning of the machine for it to hygienically process a product (e.g. fittings, piping, tubing)
3.2 bond
joining of materials with an adhesive
oSIST prEN ISO 14159:2026 ISO/DIS 14159:2026(en)
3.3 cleaning in place
cleaning (3.4) of a machine or an equipment of a machine without dismantling parts Note 1 to entry: for example, providing circulation of flowing chemical solutions, cleaning liquid and water rinses onto and over surfaces.
3.4 cleaning
removal of soil (see 3.33)
3.5 cleanable
designed and constructed so that soil can be removed
3.6 consumer
end user of the product (including domestic animals)
3.7 corrosion resistant material
material having the property to maintain its original surface characteristics for its intended life time when exposed to the conditions encountered in the environment of intended use, including exposed contact with product, cleaning, disinfection, pasteurization or sterilization conditions
3.8 crevice
sharp, cleft-like, irregular opening of small depth which adversely affects cleanability
3.9 dead space
space wherein a product, cleaning or disinfecting agents, or soils can be trapped, retained, or not completely removed during the operation of cleaning
3.10 disinfection
inactivation of pathogens and a wide range of other unwanted micro-organisms to an tolerable level
3.11 hygiene
taking of all measures during product handling, preparation and processing to ensure its suitability for use by humans or domestic animals
3.12 joint
junction of two or more pieces of material
3.13 machinery
assembly, fitted with or intended to be fitted with a drive system consisting of linked parts or components, at least one of which moves, and which are joined together for a specific application Note 1 to entry: The term “machinery” also covers an assembly of machines which, in order to achieve the same end, are arranged and controlled so that they function as an integral whole. [SOURCE: ISO 12100:2010, 3.1]
3.14 manual cleaning
cleaning by manual means when the machinery is open, or partially or totally disassembled
oSIST prEN ISO 14159:2026 ISO/DIS 14159:2026(en)
3.15 micro-organism (relevant)
bacteria, fungi, yeasts, molds, spores and viruses that are able to contaminate, multiply or survive in the product and are able to be harmful or adversely affect product quality
3.16 non-toxic materials
materials which, under the intended conditions of their use, will not cause the product to be harmful to humans or domestic animals
3.17 non-absorbent materials
materials which, under the intended conditions of their use, do not retain substances with which they come into contact, so as to have no adverse effect on the hygiene of the product
3.18 pasteurization
process that inactivates all relevant micro-organisms except some microbial spores
3.19 pasteurizable
〈equipment〉 designed to be capable of being pasteurized
3.20 pest
mammals, birds, reptiles, vermin and insects which can adversely influence the product
3.21 practical test
set of procedures and parameters used to determine an evaluation
3.22 product
any substance intended to be applied or taken into humans or domestic animals (e.g.by ingestion, injection, topical application, insertion)
3.23 product area
machine and machine components surface which are exposed to the product or from which product or other materials can drain, drip, diffuse or be drawn into the product or product container
3.24 splash area
area composed of surfaces on which part of the product can splash or flow along under intended conditions of use and does not return into the product Note 1 to entry: Once product comes into contact with the splash area, it is no longer a product within the meaning of 3.22. It is then no longer used as a product and is therefore considered as soil.
3.25 non-product area
any area other than product area or splash area Note 1 to entry: Soil that comes into contact with the non-product area during the cleaning phase (rinsing) has no influence on the classification of this area
oSIST prEN ISO 14159:2026 ISO/DIS 14159:2026(en)
3.26 easily cleanable
designed and constructed to be cleanable by a simple cleaning method, where necessary after removing easily dismountable parts Note 1 to entry: Simple cleaning methods could be, e.g. vacuum cleaning, cleaning in place (CIP) or cleaning after dismantling parts without the need of tools (e.g. spanner) for dismantling. [SOURCE: EN 1672-2:2020, 3.6.2]
3.27 readily accessible
location which can be reached by an operator from the floor, a platform or other permanent work area
3.28 readily removable
designed to be separated from the machine without tools or with the use of simple hand tools Note 1 to entry: Simple hand tools are for example a screwdriver, wrench, mallet, or readily available dedicated tool(s) normally used by operating and cleaning personnel.
3.29 seal
closure of an aperture so as to effectively prevent the entry or passage of unwanted matter
3.30 self-draining
combination of design, construction, installation and surface finish so as to prevent the retention of liquid except for normal surface wetting
3.31 sensors
devices or instrumentation attached to machinery for process monitoring/control
3.32 smooth
condition of a surface which satisfies hygienic requirements and is without surface defects (e.g. crevices) capable or retaining soil
3.33 soil
any unwanted matter
3.34 sterilization
a process aimed at removing or killing all forms of micro-organisms, including bacterial spores
3.35 sterilizability
〈equipment〉 designed to be capable of being sterilized
3.36 wet cleaning
cleaning with the liquid solvent
3.37 dry cleaning
solvent free cleaning
oSIST prEN ISO 14159:2026 ISO/DIS 14159:2026(en)
3.38 verification
application of methods, procedures, test and other evaluations, in addition to monitoring to determine compliance
3.39 hygienic integrity
probability of a hygiene-related system satisfactorily performing the required hygiene functions under all the specified conditions within a specified period of time.
4 List of significant hazards
The significant hazards can arise from:
a) microbiological causes, e.g.:
1) pathogens (from e.g. opportunistic pathogens like salmonella, Enterobacter, coliform bacteria) 2) microbiological toxins (from e.g. Bacillus cereus, Staphylococcus aureus) and biogenic amines of pathogens 3) microorganism 4) other biological causes, e.g.:
- mono- and multicellular vermin (e.g. toxoplasma, tapeworm); - unconventional transmissible agents b) Chemical causes, e.g.:
- cleaning and disinfection agents - lubricants - veterinary drugs - agricultural pesticides - contaminants, e.g. allergens, dioxins, polychlorinated biphenyl (PCB), mycotoxins, heavy metals - substances released by materials c) Physical causes, e.g.:
- foreign bodies (e.g. bone fragments, metal parts and broken glass)
- contaminants and radiation arising from raw material, machinery or other sources Malfunction of machinery or malfunction of equipment e.g.:
- Interruption of the flow of modifying or protective gases
- Malfunction of filters
- Interruption of the flow of sterilized air
- Malfunction of pasteurizing or sterilizing system
- Malfunction of the cleaning system can have an impact on hygiene causing hazardous situations.
Note 1 to entry further information of significant hazards is available in Annex B
oSIST prEN ISO 14159:2026 ISO/DIS 14159:2026(en)
5 Hygiene requirements and hygiene measures
5.1 General
Either hygiene requirements or risk reduction measures or both shall be implemented
5.2 Risk assessment strategy
The risk assessment strategy for selecting hygiene measures is applicable to the product area, splash area and non-product areas.
NOTE For more information see EN 1672-2:2020 or ISO TR 14121-2:2013 / ANSI document ANSI B11.0 2023
5.2.1 Basic strategy for selecting hygiene measures
The basic strategy for selecting hygiene measures for the design of machinery and equipment shall be consistent with ISO 12100:2010. This includes the following:
- identification of the process for which the machine is intended
- hazards associated with the product(s) produced (see clause 4)
- hygiene risk assessment associated with each hazard identified (see clause 5.2.3)
- hygiene risk reduction which can eliminate hazards or reduce risks associated with these hazards (see clause 6)
- identification of any other hazards (either safety or hygienic) which can be introduced by methods used to reduce the risk associated with the hazard under analysis
- means of verification of the effectiveness of the hazard elimination or the risk reduction method (see clause 7)
- description of residual risks and any additional precautions necessary in the information for use where applicable (see clauses 7 and 8) Applying measures to reduce hygiene risks, such as improving visibility, can sometimes raise safety risks. The iterative hygiene risk reduction procedure is schematically represented in Figure 1.
5.2.2 Elements of risk assessment
When undertaking the elements of the risk assessment, the following parameters are presented as guidance to the range and type of factors that shall be considered for the machine and its associated equipment. The intended use of the machine: Will the machine be used for one specific purpose only, for which the hazards are readily identifiable, or could the machine be used for a wide range of products in various industrial sectors (e.g. a pump)?
The product type to be processed by the machine: Will the product be already contaminated (e.g. a raw material) or will it be “preserved” or aseptic?
The degree of further processing: Will the product processed by the machinery subsequently undergo a further process which functions as a hazard elimination step (e.g. a heat treatment) or is the process for which the machine is intended the final process?
Specific application of the product:
1. Is the product to be used by the consumer immediately after processing or is there a product shelf-life in which the severity of the hazard could increase (e.g. relevant microbial growth)?
oSIST prEN ISO 14159:2026 ISO/DIS 14159:2026(en) 2. Will the product be used by a specific consumer group to whom the hazard may present a more serious risk (e.g.: a baby, elderly or infirm person)?
The degree of cleaning, disinfection, pasteurization, sterilization and/or inspection: Is the machine to be cleaned, disinfected, pasteurized, sterilized and/or inspected after every use, routinely during the day, every day, or every week, etc.?
The use of the machine: Is the machine likely to be well maintained or used infrequently. Is it designed for high or continuous use or is misuse foreseeable?
Figure 1 — Schematic iterative hygiene risk reduction procedure
5.2.3 Hygiene risk assessment (see Figure 1, Item 27)
Hygiene risk assessment comprises
oSIST prEN ISO 14159:2026 ISO/DIS 14159:2026(en) - A Hygiene risk analysis - B Hygiene risk estimation - C Hygiene risk evaluation (A) Hygiene risk analysis (see Figure 1, Item 26) Hygiene risk analysis, comprising:
(1) determination of the limits of the machinery (2) product safety hazard identification Hygiene risk analysis provides information required for the hygiene risk evaluation which in turn allows judgments to be made about whether or not risk reduction is required. The risk assessment shall start with the determination of the limits of the machinery, considering all the phases of the machinery life After determination of the limits of the product processing machine, the most important step in the hygiene risk assessment is the identification of each hazards that can lead to unsafe product. The identification of the product safety hazard by the manufacturer shall take into account the significant hazards defined in Clause 4.
The objective of the product hazard identification is to create a list of all the hazards to hygiene that arise from contact with product processing machines and/or their processing steps. Unidentified hazards can lead to unsafe products which can cause health harm of its consumers. Only when a hazard (incl. hazardous situations and/or hazardous events) has been identified, it is possible to take action to eliminate them or to reduce resulting associated risks. For the identification of product safety hazards the following factors described in “Product safety hazard identification” shall be considered.
After product safety hazard identification, hygiene risk estimation shall be carried out for each hazard and/ or hazardous situation.
The elements of risk given in: Severity of health harm, Probability of occurrence of health harm, Existing possibilities to avoid or limit health harm as well as aspects to be considered given in: Consumers Combination of hazards, Human factors, Tools for hygiene risk estimation shall be taken into account. Product safety hazards can lead to unsafe product, and its consumption can lead to health harm. The hygiene risk associated with a particular hazard depends on the following elements:
- the severity of health harm - the probability of occurrence of health harm, which is a function of - the occurrence of a hazardous event - the technical and human possibilities to avoid or limit the health harm. NOTE 1 The exposure of an operator to the "hygienic" hazard is not considered according to the scope of this standard.
NOTE 2 Possibilities to avoid or limit health harm are measures such as washing, peeling, cooking, baking, before consuming (this is not applicable to ready-to-eat product) considered in Hygiene risk estimation. (1) Determination of the limits of the machine (see Figure 1, Item 2) a) Use limits Use limits shall include the intended use and the reasonably foreseeable misuse, failure or malfunction.
oSIST prEN ISO 14159:2026 ISO/DIS 14159:2026(en) One machine can be used for one specific purpose only (single product type), for which hazards are readily identifiable. Another machine can be used for a wide range of product products (more than one product type) under various conditions.
In connection with hygienic aspects, the following issues shall be considered:
- the different operating modes (e.g. product processing, cleaning, maintenance) - the type of operators - professional and/or non-professional - the anticipated foreseeable users’ level of training, experience or ability (e.g. operators, cleaning personnel, maintenance personnel) b) Space limits The following aspects of space limits shall be considered:
- the range of movements of the machine and of all its parts (e.g. access to maintenance openings)
- space requirements for operators interacting with the machine during operation, cleaning and maintenance.
NOTE 1 Space requirements can include necessary space for e.g. cleaning, removing parts. c) Time limits The following aspects of time limits shall be considered:
- the life limit of the machinery and/or of some of its components (parts that can wear, seals etc.), taking into account its intended use and reasonably foreseeable misuse - recommended maintenance intervals - recommended cleaning intervals d) Other limits Examples of other limits:
...