General Information

Abstract

This European Standard specifies a room method for the measurement of the pollutant concentration parameter of a specified airborne hazardous substance from machines, located in a test room and operating the machines under defined conditions.
This method can only be used for machines with a local exhaust ventilation with an air flow rate ³ 500 m3/h and machines without recirculated air.
Measurement of the pollutant concentration parameter of a machine can serve for the:
a)   evaluation of the performance of a machine;
b)   evaluation of the improvement of the machine;
c)   comparison of machines within groups of machines with the same intended use (groups are defined by the function and materials processed);
d)   ranking of machines from the same group according to their pollutant concentration parameters;
e)   determination of the state of the art of machines with respect to their pollutant concentration parameter.

Status
Published
Publication Date
15-Jul-2008
Current Stage
9020 - Submission to 2 Year Review Enquiry - Review Enquiry
Start Date
15-Jul-2026
Completion Date
15-Jul-2026
 

Not Harmonized98/37/EC - Machinery

Buy Documents

Standard

EN 1093-9:2000+A1:2008

English language (9 pages)
Preview
Preview
e-Library read for
1 day

Overview

EN 1093-9:1998+A1:2008 - Safety of machinery: Evaluation of the emission of airborne hazardous substances - Part 9: Pollutant concentration parameter, room method - specifies a standardized room test to measure the pollutant concentration parameter (Pcr) produced by machines. The method applies to machines operated in a controlled test room, with local exhaust ventilation (LEV) ≥ 500 m3/h or machines without recirculated air. The measured Pcr helps quantify airborne emissions for performance evaluation, product comparison and state-of-the-art assessments.

Key topics and technical requirements

  • Test environment
    • Test room volume greater than 200 m3.
    • Machine at least 2 m from walls and ceiling; no other sources of the specified pollutant.
    • No recirculated air from LEV; supply air designed to avoid cross-draughts.
    • Verify airflow patterns (e.g., smoke cartridge) so measurement points’ air flows toward LEV.
  • Measurement points and sampling
    • Minimum of 4 measurement points positioned empirically in major emission zones; exact locations defined in relevant type C standards.
    • At least three measurements per point to capture variability.
  • Operation and measurement procedures
    • Machines operated according to intended use, manufacturer instructions and type C standards (e.g., feed rate, tooling, materials).
    • Measurement methods must conform to appropriate International/European standards; measuring time must represent normal operational cycles (including consideration of start-up emissions).
    • Instruments must be calibrated; environmental data (temperature, humidity, pressure) recorded.
  • Result expression
    • Compute mean and standard deviation per test and per point.
    • Pcr = mean value + one-sided 95% confidence interval (room pollutant concentration parameter).
  • Reporting
    • Test report must document machine details, test room layout, LEV description and airflow, measurement procedures and instruments, raw concentrations, Pcr and confidence interval, deviations, tester and dates.

Practical applications

EN 1093-9 supports:

  • Performance evaluation of emission control on machines.
  • Design improvements and verification after modifications.
  • Comparative testing and ranking of machines within the same application group (same function/materials processed).
  • Benchmarking and establishing state-of-the-art emission levels for product families.

Who uses this standard

  • Machine manufacturers and OEMs
  • Accredited test laboratories and independent certifiers
  • Health, Safety & Environment (HSE) engineers
  • Regulatory and conformity assessment bodies
  • R&D teams working on emission control and ventilation design

Related standards

  • EN 1093-1 (selection of test methods)
  • ENV 1070 (terminology)
  • EN 292-1 / EN 292-2 (safety fundamentals)
  • ISO 2602 (statistical interpretation of test results)
  • References to EU Directives: Annex ZA/ZB relate this standard to Directive 98/37/EC and 2006/42/EC (machinery).

Keywords: EN 1093-9:1998+A1:2008, pollutant concentration parameter, room method, safety of machinery, airborne hazardous substances, local exhaust ventilation, test room.

Relations

Effective Date
22-Dec-2008
Effective Date
18-Mar-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026
Effective Date
28-Jan-2026

Buy Documents

Standard

EN 1093-9:2000+A1:2008

English language (9 pages)
Preview
Preview
e-Library read for
1 day

Get Certified

Connect with accredited certification bodies for this standard

CIS Institut d.o.o.

Personal Protective Equipment (PPE) certification body. Notified Body NB-2890 for EU Regulation 2016/425 PPE.

SA Slovenia Verified

Kiwa BDA Testing

Building and construction product certification.

RVA Netherlands Verified

Kmetijski inštitut Slovenije

Agricultural Institute of Slovenia. Soil testing, plant health, agricultural product analysis.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

EN 1093-9:1998+A1:2008 is a standard published by the European Committee for Standardization (CEN). Its full title is "Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 9: Pollutant concentration parameter, room method". This standard covers: This European Standard specifies a room method for the measurement of the pollutant concentration parameter of a specified airborne hazardous substance from machines, located in a test room and operating the machines under defined conditions. This method can only be used for machines with a local exhaust ventilation with an air flow rate ³ 500 m3/h and machines without recirculated air. Measurement of the pollutant concentration parameter of a machine can serve for the: a) evaluation of the performance of a machine; b) evaluation of the improvement of the machine; c) comparison of machines within groups of machines with the same intended use (groups are defined by the function and materials processed); d) ranking of machines from the same group according to their pollutant concentration parameters; e) determination of the state of the art of machines with respect to their pollutant concentration parameter.

This European Standard specifies a room method for the measurement of the pollutant concentration parameter of a specified airborne hazardous substance from machines, located in a test room and operating the machines under defined conditions. This method can only be used for machines with a local exhaust ventilation with an air flow rate ³ 500 m3/h and machines without recirculated air. Measurement of the pollutant concentration parameter of a machine can serve for the: a) evaluation of the performance of a machine; b) evaluation of the improvement of the machine; c) comparison of machines within groups of machines with the same intended use (groups are defined by the function and materials processed); d) ranking of machines from the same group according to their pollutant concentration parameters; e) determination of the state of the art of machines with respect to their pollutant concentration parameter.

EN 1093-9:1998+A1:2008 is classified under the following ICS (International Classification for Standards) categories: 13.040.40 - Stationary source emissions. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1093-9:1998+A1:2008 has the following relationships with other standards: It is inter standard links to EN 1093-9:1998, ISO 2602:1980, EN 292-2:1991/A1:1995, EN 1093-1:2008, EN 292-1:1991, EN ISO 8321-1:2002, EN 292-2:1991, EN 12629-7:2004+A1:2010. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

EN 1093-9:1998+A1:2008 is associated with the following European legislation: EU Directives/Regulations: 2006/42/EC, 98/37/EC; Standardization Mandates: M/079, M/396. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 1093-9:1998+A1:2008 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Varnost strojev - Vrednotenje emisije nevarnih snovi, ki jih prenaša zrak - 9. del: Parameter koncentracije onesnaževalnih snovi, metoda preskusa v preskusnem prostoruSicherheit von Maschinen - Bewertung der Emission von luftgetragenen Gefahrstoffen - Teil 9: Konzentrationsparameter des luftverunreinigenden Stoffes, PrüfraumverfahrenSécurité des machines - Evaluation de l'émission de substances dangereuses véhiculées par l'air - Partie 9: Paramètre de concentration en polluant, méthode en salle d'essaiSafety of machinery - Evaluation of the emission of airborne hazardous substances - Part 9: Pollutant concentration parameter, room method13.110Varnost strojevSafety of machinery13.040.40Stationary source emissionsICS:Ta slovenski standard je istoveten z:EN 1093-9:1998+A1:2008SIST EN 1093-9:2000+A1:2008en,fr,de01-december-2008SIST EN 1093-9:2000+A1:2008SLOVENSKI
STANDARD
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1093-9:1998+A1
July 2008 ICS 13.040.40 Supersedes EN 1093-9:1998English Version
Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 9: Pollutant concentration parameter, room method
Sécurité des machines - Evaluation de l'émission de substances dangereuses véhiculées par l'air - Partie 9: Paramètre de concentration en polluant, méthode en salle d'essai
Sicherheit von Maschinen - Bewertung der Emission von luftgetragenen Gefahrstoffen - Teil 9: Konzentrationsparameter des luftverunreinigenden Stoffes, Prüfraumverfahren This European Standard was approved by CEN on 4 September 1998 and includes Amendment 1 approved by CEN on 8 June 2008.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36
B-1050 Brussels © 2008 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1093-9:1998+A1:2008: ESIST EN 1093-9:2000+A1:2008

!Relationship between this European Standard and the Essential Requirements of EU Directive 98/37/EC".8 Annex ZB (informative)
!Relationship between this European Standard and the Essential Requirements of EU Directive 2006/42/EC".9
...