Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)

ISO 5167-1:2003 defines terms and symbols and establishes the general principles for methods of measurement and computation of the flowrate of fluid flowing in a conduit by means of pressure differential devices (orifice plates, nozzles and Venturi tubes) when they are inserted into a circular cross-section conduit running full.
ISO 5167-1:2003 also specifies the general requirements for methods of measurement, installation and determination of the uncertainty of the measurement of flowrate. It also defines the general specified limits of pipe size and Reynolds number for which these pressure differential devices are to be used.
ISO 5167 (all parts) is applicable only to flow that remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. It is not applicable to the measurement of pulsating flow.

Durchflussmessung von Fluiden mit Drosselgeräten in voll durchströmten Leitungen mit Kreisquerschnitt - Teil 1: Allgemeine Grundlagen und Anforderungen (ISO 5167-1:2003)

Dieser Teil von ISO 5167 legt Begriffe und Symbole fest und gibt die allgemeinen Grundlagen für Mess- und Berechnungsverfahren für den Durchfluss von Fluiden in voll durchströmten Leitungen mit Kreisquerschnitt mittels Drosselgeräten (Blenden, Düsen und Venturirohre) an. Dieser Teil von ISO 5167 legt auch allgemeine Anforderungen an die Messverfahren, den Einbau von Drosselgeräten und die Ermittlung der Messunsicherheit der Durchflussmessung fest. Er legt ferner die Grenzen für Rohrdurchmesser und Reynolds-Zahlen fest, innerhalb derer die Drosselgeräte angewendet werden dürfen.
ISO 5167 (mit allen Teilen) gilt nur für Strömungen, die im ganzen Messquerschnitt im Unterschallbereich liegen und bei denen es sich um einphasige Fluide handelt. Er gilt nicht für Messungen bei pulsierenden Strömungen.

Mesure de débit des fluides au moyen d'appareils déprimogènes insérés dans des conduites en charge de section circulaire - Partie 1: Principes généraux et exigences générales (ISO 5167-1:2003)

L'ISO 5167-1:2003 définit des termes et symboles et établit les principes généraux pour le mesurage et le calcul du débit des fluides dans une conduite au moyen d'appareils déprimogènes (diaphragmes, tuyères et tubes de Venturi) insérés dans des conduites en charge de section circulaire.
L'ISO 5167-1:2003 spécifie aussi les exigences générales en ce qui concerne les méthodes de mesurage, l'installation des appareils et la détermination de l'incertitude de la mesure de débit. Elle définit en outre les limites générales spécifiées de diamètre de conduite et de nombre de Reynolds, à l'intérieur desquelles ces appareils déprimogènes sont destinés à être utilisés.
L'ISO 5167 (toutes les parties) est applicable uniquement à un écoulement qui reste subsonique dans tout le tronçon de mesurage et où le fluide peut être considéré comme monophasique. Elle n'est pas applicable au mesurage d'un écoulement pulsé.

Merjenje pretoka fluida na osnovi tlačne razlike, povzročene z napravo, vstavljeno v polno zapolnjen vod s krožnim prerezom – 1. del: Splošna načela in zahteve (ISO 5167-1:2003)

General Information

Status
Withdrawn
Publication Date
28-Feb-2003
Withdrawal Date
28-Jun-2022
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
29-Jun-2022

Relations

Buy Standard

Standard
EN ISO 5167-1:2004
English language
35 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-januar-2004
1DGRPHãþD
SIST EN ISO 5167-1:1997
SIST EN ISO 5167-1:1997/A1:2001
0HUMHQMHSUHWRNDIOXLGDQDRVQRYLWODþQHUD]OLNHSRY]URþHQH]QDSUDYRYVWDYOMHQR
YSROQR]DSROQMHQYRGVNURåQLPSUHUH]RP±GHO6SORãQDQDþHODLQ]DKWHYH ,62

Measurement of fluid flow by means of pressure differential devices inserted in circular
cross-section conduits running full - Part 1: General principles and requirements (ISO
5167-1:2003)
Durchflussmessung von Fluiden mit Drosselgeräten in voll durchströmten Leitungen mit
Kreisquerschnitt - Teil 1: Allgemeine Grundlagen und Anforderungen (ISO 5167-1:2003)
Mesure de débit des fluides au moyen d'appareils déprimogenes insérés dans des
conduites en charge de section circulaire - Partie 1: Principes généraux et exigences
générales (ISO 5167-1:2003)
Ta slovenski standard je istoveten z: EN ISO 5167-1:2003
ICS:
17.120.10 Pretok v zaprtih vodih Flow in closed conduits
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD
EN ISO 5167-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
March 2003
ICS 17.120.10 Together with EN ISO 5167-2:2003,
EN ISO 5167-3:2003 and EN ISO 5167-4:2003,
supersedes EN ISO 5167-1:1995
English version
Measurement of fluid flow by means of pressure differential
devices inserted in circular cross-section conduits running full -
Part 1: General principles and requirements (ISO 5167-1:2003)
Mesure de débit des fluides au moyen d'appareils Durchflussmessung von Fluiden mit Drosselgeräten in voll
déprimogènes insérés dans des conduites en charge de durchströmten Leitungen mit Kreisquerschnitt - Teil 1:
section circulaire - Partie 1: Principes généraux et Allgemeine Grundlagen und Anforderungen (ISO 5167-
exigences générales (ISO 5167-1:2003) 1:2003)
This European Standard was approved by CEN on 20 February 2003.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovak Republic, Spain, Sweden, Switzerland and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: rue de Stassart, 36  B-1050 Brussels
© 2003 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 5167-1:2003 E
worldwide for CEN national Members.

CORRECTED  2003-09-03
Foreword
This document (EN ISO 5167-1:2003) has been prepared by Technical Committee ISO/TC 30
"Measurement of fluid flow in closed conduits" in collaboration with CMC.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by September 2003, and conflicting national
standards shall be withdrawn at the latest by September 2003.
This document, together with EN ISO 5167-2:2003, EN ISO 5167-3:2003 and EN ISO 5167-4:2003,
supersedes EN ISO 5167-1:1995.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Czech
Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Luxembourg, Malta, Netherlands, Norway, Portugal, Slovak Republic, Spain, Sweden, Switzerland
and the United Kingdom.
NOTE FROM CMC  The foreword is susceptible to be amended on reception of the German
language version. The confirmed or amended foreword, and when appropriate, the normative
annex ZA for the references to international publications with their relevant European publications
will be circulated with the German version.
Endorsement notice
The text of ISO 5167-1:2003 has been approved by CEN as EN ISO 5167-1:2003 without any
modifications.
INTERNATIONAL ISO
STANDARD 5167-1
Second edition
2003-03-01
Measurement of fluid flow by means of
pressure differential devices inserted in
circular cross-section conduits running
full —
Part 1:
General principles and requirements
Mesure de débit des fluides au moyen d'appareils déprimogènes
insérés dans des conduites en charge de section circulaire —
Partie 1: Principes généraux et exigences générales

Reference number
ISO 5167-1:2003(E)
©
ISO 2003
ISO 5167-1:2003(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.

©  ISO 2003
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2003 — All rights reserved

ISO 5167-1:2003(E)
Contents Page
Foreword. iv
Introduction . v
1 Scope. 1
2 Normative references . 1
3 Terms and definitions. 1
4 Symbols and subscripts. 6
4.1 Symbols . 6
4.2 Subscripts. 7
5 Principle of the method of measurement and computation. 7
5.1 Principle of the method of measurement . 7
5.2 Method of determination of the diameter ratio of the selected standard primary device . 8
5.3 Computation of flowrate. 8
5.4 Determination of density, pressure and temperature . 8
6 General requirements for the measurements . 10
6.1 Primary device. 10
6.2 Nature of the fluid . 11
6.3 Flow conditions. 11
7 Installation requirements . 11
7.1 General. 11
7.2 Minimum upstream and downstream straight lengths . 13
7.3 General requirement for flow conditions at the primary device . 13
7.4 Flow conditioners (see also Annex C). 13
8 Uncertainties on the measurement of flowrate. 16
8.1 Definition of uncertainty. 16
8.2 Practical computation of the uncertainty . 17
Annex A (informative) Iterative computations. 19
Annex B (informative) Examples of values of the pipe wall uniform equivalent roughness, k . 21
Annex C (informative) Flow conditioners and flow straighteners. 22
Bibliography . 33

ISO 5167-1:2003(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 5167-1 was prepared by Technical Committee ISO/TC 30, Measurement of fluid flow in closed conduits,
Subcommittee SC 2, Pressure differential devices.
This second edition of ISO 5167-1, together with the first editions of ISO 5167-2, ISO 5167-3 and ISO 5167-4,
cancels and replaces the first edition (ISO 5167-1:1991), which has been technically revised, and
ISO 5167-1:1991/Amd.1:1998.
ISO 5167 consists of the following parts, under the general title Measurement of fluid flow by means of
pressure differential devices inserted in circular cross-section conduits running full:
— Part 1: General principles and requirements
— Part 2: Orifice plates
— Part 3: Nozzles and Venturi nozzles
— Part 4: Venturi tubes
iv © ISO 2003 — All rights reserved

ISO 5167-1:2003(E)
Introduction
ISO 5167, consisting of four parts, covers the geometry and method of use (installation and operating
conditions) of orifice plates, nozzles and Venturi tubes when they are inserted in a conduit running full to
determine the flowrate of the fluid flowing in the conduit. It also gives necessary information for calculating the
flowrate and its associated uncertainty.
ISO 5167 is applicable only to pressure differential devices in which the flow remains subsonic throughout the
measuring section and where the fluid can be considered as single-phase, but is not applicable to the
measurement of pulsating flow. Furthermore, each of these devices can only be used within specified limits of
pipe size and Reynolds number.
ISO 5167 deals with devices for which direct calibration experiments have been made, sufficient in number,
spread and quality to enable coherent systems of application to be based on their results and coefficients to
be given with certain predictable limits of uncertainty.
The devices introduced into the pipe are called “primary devices”. The term primary device also includes the
pressure tappings. All other instruments or devices required for the measurement are known as “secondary
1)
devices”. ISO 5167 covers primary devices; secondary devices will be mentioned only occasionally.
ISO 5167 consists of the following four parts.
a) This part of ISO 5167 gives general terms and definitions, sym
...

Questions, Comments and Discussion