Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)

This part of IEC 62209 series is applicable to any wireless communication device capable of transmitting electromagnetic fields (EMF) intended to be used at a position near the human body, in the manner described by the manufacturer, with the radiating part(s) of the device at distances up to and including 200 mm from a human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in garments. For transmitters used in close proximity to the human ear, the procedures of IEC 62209-1:2005 are applicable. This standard is applicable for radio frequency exposure in the frequency range of 30 MHz to 6 GHz, and may be used to measure simultaneous exposures from multiple radio sources used in close proximity to human body. Definitions and evaluation procedures are provided for the following general categories of device types: body-mounted, body-supported, desktop, front-of-face, hand-held, laptop, limb-mounted, multi-band, push-to-talk, clothing-integrated. The types of devices considered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers. This International Standard gives guidelines for a reproducible and conservative measurement methodology for determining the compliance of wireless devices with the SAR limits. Because studies suggest that exclusion of features to represent a hand in human models constitutes a conservative case scenario for SAR in the trunk and the head, a representation of a hand is not included if the device is intended to be used next to the head or supported on or near the torso [73], [80]. This standard does not apply for exposures from transmitting or non-transmitting implanted medical devices. This standard does not apply for exposure from devices at distances greater than 200 mm away from the human body. IEC 62209-2 makes cross-reference to IEC 62209-1:2005 where complete clauses or subclauses apply, along with any changes specified.

Sicherheit von Personen in hochfrequenten Feldern von handgehaltenen und am Körper getragenen schnurlosen Kommunikationsgeräten – Körpermodelle, Messgeräte und Verfahren – Teil 2: Verfahren zur Bestimmung der spezifischen Absorptionsrate (SAR) von schnurlosen Kommunikationsgeräten, die in enger Nachbarschaft zum menschlichen Körper verwendet werden (Frequenzbereich von 30 MHz bis 6 GHz)

Exposition humaine aux champs radiofréquence produits par les dispositifs de communications sans fils tenus à la main ou portés près du corps - Modèles de corps humain, instrumentation et procédures - Partie 2: Procédure de détermination du débit d'absorption spécifique produit par les appareils de communications sans fil utilisés très près du corps humain (gamme de fréquences de 30 MHz à 6 GHz)

Izpostavljenost ljudi elektromagnetnim sevanjem brezžičnih komunikacijskih naprav, ki se držijo v roki ali pritrdijo na telo - Modeli človeka, instrumenti in postopki - 2. del: Postopki za določanje stopnje specifične absorpcije (SAR) za brezžične komunikacijske naprave, ki se uporabljajo v bližini telesa (frekvenčno območje od 30 MHz do 6 GHz)

General Information

Status
Withdrawn
Publication Date
27-Jun-2019
Withdrawal Date
20-Jun-2022
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
19-Nov-2024
Completion Date
19-Nov-2024

Relations

Buy Standard

Amendment
EN 62209-2:2010/A1:2019
English language
6 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2019
Izpostavljenost ljudi elektromagnetnim sevanjem brezžičnih komunikacijskih
naprav, ki se držijo v roki ali pritrdijo na telo - Modeli človeka, instrumenti in
postopki - 2. del: Postopki za določanje stopnje specifične absorpcije (SAR) za
brezžične komunikacijske naprave, ki se uporabljajo v bližini telesa (frekvenčno
območje od 30 MHz do 6 GHz)
Human exposure to radio frequency fields from hand-held and body-mounted wireless
communication devices - Human models, instrumentation, and procedures - Part 2:
Procedure to determine the specific absorption rate (SAR) for wireless communication
devices used in close proximity to the human body (frequency range of 30 MHz to 6
GHz)
Sicherheit von Personen in hochfrequenten Feldern von handgehaltenen und am Körper
getragenen schnurlosen Kommunikationsgeräten – Körpermodelle, Messgeräte und
Verfahren – Teil 2: Verfahren zur Bestimmung der spezifischen Absorptionsrate (SAR)
von schnurlosen Kommunikationsgeräten, die in enger Nachbarschaft zum
menschlichen Körper verwendet werden (Frequenzbereich von 30 MHz bis 6 GHz)
Exposition humaine aux champs radiofréquence produits par les dispositifs de
communications sans fils tenus à la main ou portés près du corps - Modèles de corps
humain, instrumentation et procédures - Partie 2: Procédure de détermination du débit
d'absorption spécifique produit par les appareils de communications sans fil utilisés très
près du corps humain (gamme de fréquences de 30 MHz à 6 GHz)
Ta slovenski standard je istoveten z: EN 62209-2:2010/A1:2019
ICS:
13.280 Varstvo pred sevanjem Radiation protection
33.050.10 Telefonska oprema Telephone equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 62209-2:2010/A1

NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2019
ICS 33.050.10
English Version
Human exposure to radio frequency fields from hand-held and
body-mounted wireless communication devices - Human
models, instrumentation, and procedures - Part 2: Procedure to
determine the specific absorption rate (SAR) for wireless
communication devices used in close proximity to the human
body (frequency range of 30 MHz to 6 GHz)
(IEC 62209-2:2010/A1:2019)
Exposition humaine aux champs radiofréquence produits Sicherheit von Personen in hochfrequenten Feldern von
par les dispositifs de communications sans fils tenus à la handgehaltenen und am Körper getragenen schnurlosen
main ou portés près du corps - Modèles de corps humain, Kommunikationsgeräten - Körpermodelle, Messgeräte und
instrumentation et procédures - Partie 2: Procédure de Verfahren - Teil 2: Verfahren zur Bestimmung der
détermination du débit d'absorption spécifique produit par spezifischen Absorptionsrate (SAR) von schnurlosen
les appareils de communications sans fil utilisés très près Kommunikationsgeräten, die in enger Nachbarschaft zum
du corps humain (gamme de fréquences de 30 MHz à 6 menschlichen Körper verwendet werden (Frequenzbereich
GHz) von 30 MHz bis 6 GHz)
(IEC 62209-2:2010/A1:2019) (IEC 62209-2:2010/A1:2019)
This amendment A1 modifies the European Standard EN 62209-2:2010; it was approved by CENELEC on 2019-06-21. CENELEC
members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the
status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 62209-2:2010/A1:2019 E

European foreword
The text of document 106/484/FDIS, future IEC 62209-2/A1, prepared by IEC/TC 106 "Methods for the
assessment of electric, magnetic and electromagnetic fields associated with human exposure" was submitted to
the IEC-CENELEC parallel vote and approved by CENELEC as EN 62209-2:2010/A1:2019.
The following dates are fixed:
• latest date by which the document has to be implemented at national level by (dop) 2020-03-21
publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2022-06-21
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CENELEC shall not be held responsible for identifying any or all such patent rights.

Endorsement notice
The text of the International Standard IEC 62209-2:2010/A1:2019 was approved by CENELEC as a European
Standard without any modification.
IEC 62209-2 ®
Edition 1.0 2019-05
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
A MENDMENT 1
AM ENDEMENT 1
Human exposure to radio frequency fields from hand-held and body-mounted

wireless communication devices –

Human models, instrumentation, and procedures –

Part 2: Procedure to determine the specific absorption rate (SAR) for wireless

communication devices used in close proximity to the human body (frequency

range of 30 MHz to 6 GHz)
Exposition humaine aux champs radiofréquence produits par les dispositifs

de communications sans fils tenus à la main ou portés près du corps –

Modèles de corps humain, instrumentation et procédures –

Partie 2: Procédure de détermination du débit d'absorption spécifique produit

par les appareils de communications sans fil utilisés très près du corps humain

(gamme de fréquences de 30 MHz à 6 GHz)

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.050.10 ISBN 978-2-8322-6923-7

SIST EN 62209-2:2010/A1:
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.