HD 384.4.43 S1:1980
(Main)Electrical installations of buildings - Part 4: Protection for safety - Chapter 43: Protection against overcurrent
Electrical installations of buildings - Part 4: Protection for safety - Chapter 43: Protection against overcurrent
Sets out general rules for protection of live conductors against overload and short circuit. Specifies the features of various protective devices and necessary coordination between conductors and overload protective devices. Formula for calculation of time in which a given short-circuit current will raise a conductor from the highest admissible temperature in normal duty to its limit temperature. Enumerates requirements for coordination of overload and short-circuit protection. Note: For details of -low-voltage circuit breakers, see IEC 60947-2 -low-voltage fuses, see EN 60269 -for coordination of low volatge direct-online (full voltage) motor starters with short-circuit protective devices, see EN 60947-1 - for current-carrying capacities of conductors for electrical installations of buildings, see HD 384.5.523
Elektrische Anlagen von Gebäuden - Teil 4: Schutzmaßnahmen - Kapitel 43: Überstromschutz
Installations électriques des bâtiments - Partie 4: Protection pour assurer la sécurité - Chapitre 43: Protection contre les surintensités
Donne les règles générales pour la protection des conducteurs actifs contre les surcharges et les courts-circuits. Spécifie les caractéristiques de divers dispositifs de protection et la coordination nécessaire entre les conducteurs et les dispositifs de protection contre les surcharges. Formule le calcul de la durée pendant laquelle un courant de court-circuit donné élèvera la température d'un conducteur de sa valeur la plus élevée admissible en service normal à sa valeur limite. Enumère les règles de coordination de la protection contre les surcharges et contre les courts-circuits. Note: - Pour plus de détails, - sur les disjoncteurs à basse tension, voir la EN 60947-2 - sur les coupe-circuit à fusibles à basse tension, voir la EN 60269 - sur la coordination des démarreurs de moteurs à basse tension directs (sous pleine tension) avec dispositifs de protection contre les courts-circuits, voir la EN 60947-1 - sur les intensités admissibles des conducteurs pour les installations électriques des bâtiments, voir HD 384.5.523
Električne inštalacije v zgradbah – 4. del: Zaščitni ukrepi – 43. poglavje: Zaščita pred nadtoki (IEC 60364-4-43:1977, spremenjen)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST HD 384.4.43 S1:2000
01-februar-2000
(OHNWULþQHLQãWDODFLMHY]JUDGEDK±GHO=DãþLWQLXNUHSL±SRJODYMH=DãþLWD
SUHGQDGWRNL,(&VSUHPHQMHQ
Electrical installations of buildings -- Part 4: Protection for safety -- Chapter 43:
Protection against overcurrent (IEC 60364-4-43:1977, modified)
Elektrische Anlagen von Gebäuden -- Teil 4: Schutzmaßnahmen -- Kapitel 43:
Überstromschutz
Installations électriques des bâtiments -- Partie 4: Protection pour assurer la sécurité --
Chapitre 43: Protection contre les surintensités
Ta slovenski standard je istoveten z: HD 384.4.43 S1:1980
ICS:
29.120.50 9DURYDONHLQGUXJD Fuses and other overcurrent
PHGWRNRYQD]DãþLWD protection devices
91.140.50 Sistemi za oskrbo z elektriko Electricity supply systems
SIST HD 384.4.43 S1:2000 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST HD 384.4.43 S1:2000
---------------------- Page: 2 ----------------------
SIST HD 384.4.43 S1:2000
---------------------- Page: 3 ----------------------
SIST HD 384.4.43 S1:2000
---------------------- Page: 4 ----------------------
SIST HD 384.4.43 S1:2000
---------------------- Page: 5 ----------------------
SIST HD 384.4.43 S1:2000
---------------------- Page: 6
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.