EN 61557-7:1997
(Main)Electrical safety in low voltage distribution systems up to 1 kV a.c. and 1,5 kV d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence
Electrical safety in low voltage distribution systems up to 1 kV a.c. and 1,5 kV d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 7: Phase sequence
Specifies requirements for measuring equipment applied to testing th e phase sequence in three-phase distribution systems. Indication of the phase sequence may be mechanical, visual and/or audible.
Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 kV und DC 1,5 kV - Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen - Teil 7: Drehfeld
Sécurité électrique dans les réseaux de distribution basse tension de 1 kV c.a. et 1,5 kV c.c. - Dispositifs de contrôle, de mesure ou de surveillance de mesures de protection - Partie 7: Ordre de phases
Définit les prescriptions applicables aux appareils de mesure destinés à contrôler l'ordre des phases dans des réseaux triphasés. Le dispositif d'affichage de l'ordre des phases peut être mécanique, optique et/ou acoustique.
Električna varnost v nizkonapetostnih razdelilnih sistemih za izmenične napetosti do 1 kV in enosmerne napetosti do 1,5 kV – Oprema za preskušanje, merjenje ali nadzorovanje zaščitnih ukrepov – 7. del: Fazno zaporedje (IEC 61557-7:1997)
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2000
(OHNWULþQDYDUQRVWYQL]NRQDSHWRVWQLKUD]GHOLOQLKVLVWHPLK]DL]PHQLþQHQDSHWRVWL
GRN9LQHQRVPHUQHQDSHWRVWLGRN9±2SUHPD]DSUHVNXãDQMHPHUMHQMHDOL
QDG]RURYDQMH]DãþLWQLKXNUHSRY±GHO)D]QR]DSRUHGMH,(&
Electrical safety in low voltage distribution systems up to 1 kV a.c. and 1,5 kV d.c. -
Equipment for testing, measuring or monitoring of protective measures -- Part 7: Phase
sequence
Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 kV und DC 1,5 kV - Geräte
zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen -- Teil 7: Drehfeld
Sécurité électrique dans les réseaux de distribution basse ten
...
This May Also Interest You
IEC 61010-031:2022 specifies safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement, and their related accessories. These probe assemblies are for non-contact or direct electrical connection between a part and electrical test and measurement equipment. They can be fixed to the equipment or be detachable accessories for the equipment. It has the status of a group safety publication in accordance with IEC Guide 104. This third edition cancels and replaces the second edition published in 2015, and Amendment 1:2018. IEC 61010-031 is a stand-alone standard. This edition includes the following significant technical changes with respect to the previous edition:
the scope has been made succinct. General information from the scope of Edition 2 has been moved to a new Clause 4. Consequently, Clause 4 to Clause 8 of Edition 2 have been renumbered. Clause 9 of Edition 2 has been deleted;
in Clause 2, normative references have been dated and new normative references have been added;
in 3.1.4, the definition of probe tip has been modified;
in 4.1, there is no longer any differentiation between high voltage and low voltage probe assemblies. Type C probe assemblies have been merged with Type B probe assemblies;
in 4.1 d) "Kelvin" probes have been added to the list of probe assemblies as a new Type E and a new Figure 5;
in 4.1 e), probes for voltage measurement without electrical connection to conductors have been added to the list of probe assemblies as a new Type F and a new Figure 6;
in 4.2.1, spread of fire is no longer considered as a hazard;
Subclause 4.4.2.5 from Edition 2 has been deleted;
Subclause 4.4.4.3 from Edition 2 has been deleted;
in 5.4.4.1 consideration has been given to spacings and impedance;
in 6.1.1, removable parts of probe tips which bear markings are allowed;
in 6.1.5, the voltage to be marked for measurement categories is the AC line-to-neutral or DC voltage;
in 7.4.2, requirements for unmated connectors have been modified as follows:
Table 2 has been modified and expanded,
a calculation method for clearances of connectors above 20 kV has been defined,
creepage distances have been aligned with clearances;
in 7.4.3.1 and 7.4.3.5, requirements for IP2X probe tips with retractable sleeve have been added;
in 7.4.3.2, Probe tips are now applicable to non-contact probe assemblies;
in 7.5.2.3.2, the values of Table 5 have been modified;
- Standard103 pagesEnglish languagesale 10% offe-Library read for×1 day
- 25-May-2023
- 19.080
- 2014/35/EU
- M/511
- CLC/TC 66X
The scope of the Amendment is the same as EN 61010-2-101:2017. It applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-test IVD medical purposes.
- Amendment17 pagesEnglish languagesale 10% offe-Library read for×1 day
NEW!IEC 61010-2-101:2018 is available as IEC 61010-2-101:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61010-2-101:2018 applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-test IVD medical purposes. It has the status of a group safety publication, as specified in IEC Guide 104. This document has been prepared in close collaboration with Working Group CENELEC BTTF 88.1. This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - adaptation of changes introduced by Amendment 1 of IEC 61010-1; - added tolerance for stability of AC voltage test equipment to Clause 6. This Part 2-101 is intended to be used in conjunction with IEC 61010-1. It was established on the basis of the third edition (2010) and its Amendment 1 (2016).
- Standard19 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC 61010-2-012:2019 is available as IEC 61010-2-012:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61010-2-012:2019 specifies safety requirements for electrical equipment and its accessories within the categories a) through c), wherever it is intended to be used, whenever that equipment incorporates one or more of the following characteristics: – A refrigerating system that is acted on or impacted by an integral heating function such that the combined heating and refrigerating system generates additional and/or more severe hazards than those for the two systems if treated separately. – The materials being treated in the intended application introduce significant heat into the refrigerating system, so that the refrigerating system in the application yields additional and/or more severe hazards than those for the refrigerating system if operated at the maximum rated ambient temperature alone. – An irradiation function for the materials being treated presenting additional hazards. – A function to expose the materials being treated to excessive humidity, carbon dioxide, salt mist, or other substances which can result in additional hazards. – A function of mechanical movement presenting additional hazards. – Provision for an operator to walk in to the operating area to load or unload the materials being treated. It has the status of a group safety publication in accordance with IEC Guide 104. This second edition cancels and replaces the first edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alignment with changes introduced by Amendment 1 of IEC 61010-1:2010; b) changes related to the use of small capitals for defined terms only; c) clarifications for cooling tests in 4.4.2.10; d) requirements for overtemperature protection in 10.101, including deletion of the second part of the sentence in item b), and the deletion of item c); e) changes pertaining to the accurate employment of terms "temperature", "operating temperature", "working temperature", "application temperature", "room temperature" and "ambient temperature" in 3.5.104, 3.5.105, 4.3.1, 4.3.2, 5.4.2, 8.2.1, 8.2.2, 11.7.2.101.2, 11.7.2.101.3, 13.2.102, 14.102, 15.101, 15.102, 15.103, Introduction and many other locations. For the purpose of clarification, the definition of 3.5.114, controlled temperature, is added.
- Standard89 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Apr-2022
- 19.080
- 2014/35/EU
- M/511
- CLC/TC 66X
1 Scope and object This clause of Part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the first paragraph by the following: This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of their publications for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. This Part 2 of IEC 61010 specifies safety requirements for electrical equipment and their accessories within the categories a) through c), wherever they are intended to be used, whenever that equipment incorporates one or more of the following characteristics: – A REFRIGERATING SYSTEM that is acted on or impacted by an integral heating function such that the combined heating and cooling system generates additional and/or more severe HAZARDS than those for the two systems if treated separately. – The materials being treated in the intended application introduce significant heat into the REFRIGERATING SYSTEM that the cooling system in the application yield additional and/or more severe HAZARDS than those for the cooling system if operated at the maximum RATED ambient alone. – An irradiation function for the materials being treated presenting additional HAZARDS. – A function to expose the materials being treated to excessive humidity, carbon dioxide, salt mist, or other substances which may result in additional HAZARDS. – A function of MECHANICAL MOVEMENT presenting additional HAZARDS. – Provision for an OPERATOR to walk-in to the operating area to load or unload the materials being treated.
- Amendment15 pagesEnglish languagesale 10% offe-Library read for×1 day
- 28-Apr-2022
- 19.080
- 2014/35/EU
- M/511
- CLC/TC 66X
IEC 61010-2-040:2020 is available as IEC 61010-2-040:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61010-2-040:2020 specifies safety requirements for electrical equipment intended for sterilization, washing, and disinfection of medical materials in the medical, veterinary, pharmaceutical and laboratory fields, when used under the environmental conditions of 1.4. Examples of such equipment include the following: - sterilizers and disinfectors using steam and/or hot water as the sterilant; - sterilizers and disinfectors using toxic gas, toxic aerosol or toxic vapour as the sterilant; - sterilizers and disinfectors using hot air or hot inert gas as the sterilant; and - washer-disinfectors. This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - it is established on the basis of the third edition (2010) of IEC 61010‑1 and its Amendment 1 (2016); - added tolerance for stability of a.c. voltage test equipment to 6.8.3.1; - the status of a Group Safety Publication has been removed (this does not change the technical requirements in the document).
- Standard42 pagesEnglish languagesale 10% offe-Library read for×1 day
- 25-Nov-2021
- 19.080
- 71.040.10
- 2014/35/EU
- M/511
- CLC/TC 66X
1 Scope and object This clause of Part 1 is applicable, except as follows: 1.1.1 Equipment included in scope Replacement: Replace the second paragraph by the following: This Part 2 of IEC 61010 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, whenever that equipment incorporates REFRIGERATING SYSTEMS as an integral part of, or separate from, the equipment and the equipment is in direct control of the REFRIGERATING SYSTEM. This document details all the requirements when up to 150 g of FLAMMABLE REFRIGERANT are used per stage of a REFRIGERATING SYSTEM. Additional requirements beyond the current scope of this document apply if a REFRIGERANT charge of FLAMMABLE REFRIGERANT exceeds this amount. Addition: Add the following text after the last paragraph: NOTE 101 Examples for REFRIGERATING EQUIPMENT include, but are not limited to, laboratory equipment such as laboratory refrigerators, freezers, refrigerated display cabinets. It is possible that all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard. In that case, the requirements of those other Part 2 standards will also apply. In particular, if equipment is intended to be used as a centrifuge, the requirements of IEC 61010-2-020 apply. However, when the equipment incorporates a refrigerating system and a heating function where the combination of the two introduces additional or more severe HAZARDS than if treated separately, then it is possible that IEC 61010-2-012 is applicable instead of this Part 2-011. See further information in the flow chart (Figure 102) for the selection process and guidance in the Introduction. 1.1.2 Equipment excluded from scope Addition: Add the following new item after item j): or equipment incorporating: aa) a transcritical REFRIGERANT SYSTEM (system that uses CO2) or a system that uses ammonia (NH3) as the REFRIGERANT. 1.2 Object 1.2.1 Aspects included in scope Replacement: Replace the first paragraph by the following: The object of this document is to ensure that the design and methods of construction of REFRIGERATING EQUIPMENT provide adequate protection for OPERATORS, bystanders, trained service personnel, and the surrounding area against the specific HAZARDS that relate to REFRIGERATING SYSTEMS. Addition: Add the following note after the existing note: NOTE 101 A list of HAZARDS typically associated with REFRIGERATING SYSTEMS and REFRIGERANTS is included in Annex BB.
- Amendment16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-Nov-2021
- 19.080
- 2014/35/EU
- M/511
- CLC/TC 66X
IEC 61010-2-011:2019 is available as IEC 61010-2-011:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61010-2-011:2019 specifies particular safety requirements for the following types a) to c) of electrical equipment and their accessories, wherever they are intended to be used, whenever that equipment incorporates refrigerating systems as an integral part of, or separate from, the equipment and the equipment is in direct control of the refrigerating system. This document details all the requirements when up to 150 g of flammable refrigerant are used per stage of a refrigerating system. Additional requirements beyond the current scope of this document apply if a refrigerant charge of flammable refrigerant exceeds this amount. a) Electrical test and measurement equipment This is equipment which by electromagnetic means tests, measures, indicates or records one or more electrical or physical quantities, also non-measuring equipment such as signal generators, measurement standards, power supplies for laboratory use, transducers, transmitters, etc. b) Electrical industrial process-control equipment This is equipment which controls one or more output quantities to specific values, with each value determined by manual setting, by local or remote programming, or by one or more input variables. c) Electrical laboratory equipment This is equipment which measures, indicates, monitors, inspects or analyses materials, or is used to prepare materials, and includes in vitro diagnostic (IVD) equipment. This second edition cancels and replaces the first edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) alignment with changes introduced by Amendment 1 of IEC 61010-1:2010; b) introduction of new defined terms or modified terms to align with Part 2-012 and other source documents. Editorial changes to use small capitals only for defined terms. Note the difference of defined term in 4.3.2.101 and abnormal operation in 11.7.104.3 and 11.7.104.5; c) clarifications for cooling tests in 4.4.2.10; d) changes pertaining to the accurate employment of the following terms: temperature, operating temperature, application temperature, controlled temperature, room ambient and ambient temperature; e) use of defined term to replace cooling system; f) move text of 4.4.2.101 to 4.3.2.101, since the purpose of as defined, is to simulate failure of the ambient conditions of 1.4.1 but not of the of the equipment; g) use of the term equipment to replace unit, apparatus, appliance, where applicable; h) in 5.1.2 dd) for high and low sides for each stage are required only under ; i) use of defined term to replace normal operation; j) use of defined term to replace user. It has the status of a group safety publication in accordance with IEC Guide 104.
- Standard53 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-Nov-2021
- 19.080
- 2014/35/EU
- M/511
- CLC/TC 66X
NEXT ACTION: TB ACTION BY 2021-09-14: common mods, currently at ENQ
2019-10-03 JF: NWI for A11 (PR=70187) was approved by the BTthrough decision D163/098. The work on the amendment is under way
2019-03-11 TC is addressing the negative assessment and is invited to provide the information whether the changes will be needed in the main body of the amendment or only in Annex ZZ.
Negative assessment. IEC standard is published.
- Amendment18 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Nov-2021
- 19.080
- 2014/35/EU
- 2014/53/EU
- M/511
- CLC/TC 66X
1.1.1 Probe assemblies included in scope This part of IEC 61010 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. a) Type A: low-voltage and high-voltage, non-attenuating probe assemblies. Non-attenuating probe assemblies that are RATED for direct connection to voltages exceeding 30 V r.m.s., 42,4 V peak, or 60 V d.c., but not exceeding 63 kV. They do not incorporate components which are intended to provide a voltage divider function or a signal conditioning function, but they may contain non-attenuating components such as fuses (see Figure 1). b) Type B: high-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies that are RATED for direct connection to secondary voltages exceeding 1 kV r.m.s or 1,5 kV d.c. but not exceeding 63 kV r.m.s or d.c. The divider function may be carried out wholly within the probe assembely, or partly within the test or measurement equipment to be used with the probe assembly (see Figure 2). c) Type C: low-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies for direct connection to voltages not exceeding 1 kV r.m.s. or 1,5 kV d.c. The signal conditioning function may be carried out wholly within the probe assembly, or partly within the test or measurement equipment intended to be used with the probe assembly (see Figure 3). d) Type D: low-voltage attenuating, non-attenuating or other signal conditioning probe assemblies, that are RATED for direct connection only to voltages not exceeding 30 V r.m.s., or 42,4 V peak, or 60 V d.c., and are suitable for currents exceeding 8 A (see Figure 4). 1.1.2 Probe assemblies excluded from scope This standard does not apply to current sensors within the scope of IEC 61010-2-032 (hand-held and hand-manipulated current sensors), but may apply to their input measuring circuit leads and accessories.
- Amendment8 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Nov-2021
- 19.080
- 2014/35/EU
- M/511
- CLC/TC 66X
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.