HD 60364-5-559:2012
(Main)Low-voltage electrical installations - Part 5-559: Selection and erection of electrical equipment - Luminaires and lighting installations
Low-voltage electrical installations - Part 5-559: Selection and erection of electrical equipment - Luminaires and lighting installations
IEC 60364-5-55:2011 covers requirements for the selection and erection of low-voltage generating sets and for the selection and erection of luminaires and lighting installations intended to be part of the fixed installation. This second edition cancels and replaces the first edition, published in 2001, its Amendment 1 (2001) and its Amendment 2 (2008). The major technical changes with respect to the previous edition are: - additional requirements for connection of luminaires to the fixed wiring; - modification of requirements regarding the fixing of luminaires; - inclusion of alternative solutions for connecting devices used for through wiring and for connection of luminaires to the supply; - withdrawal of Clause 556, as IEC 60364-5-56 now covers this matter.
Errichten von Niederspannungsanlagen - Teil 5-559: Auswahl und Errichtung elektrischer Betriebsmittel - Leuchten und Beleuchtungsanlagen
Installations électriques à basse tension - Partie 5-559: Choix et mise en œuvre des matériels électriques - Luminaires et installations d'éclairage
La CEI 60364-5-55:2011 couvre les exigences pour le choix et la mise en oeuvre des groupes générateurs basse tension et est applicable au choix et à la mise en oeuvre des luminaires et des installations d'éclairage destinés à faire partie de l'installation fixe. Cette seconde édition annule et remplace la première édition, publiée en 2001, son Amendement 1 (2001) et son Amendement 2 (2008). Les modifications principales par rapport à l'édition précédente sont: - des exigences supplémentaires pour la connexion des luminaires à l'installation fixe; - des modifications d'exigences concernant la fixation des luminaires; - l'ajout de solutions alternatives pour les dispositifs de connexion utilisés pour le câblage passant et pour la connexion de luminaires au réseau d'alimentation; - la suppression de l'Article 556, maintenant couvert par CEI 60364-5-56.
Nizkonapetostne električne inštalacije - 5-559. del: Izbira in namestitev električne opreme - Svetilke in inštalacije razsvetljave (IEC 60364-5-55:2011- spremenjen)
Uporablja se za izbiro in namestitev svetilk in inštalacije razsvetljave, namenjene za del stalne inštalacije.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-julij-2012
1DGRPHãþD
SIST HD 60364-5-559:2005
1L]NRQDSHWRVWQHHOHNWULþQHLQãWDODFLMHGHO,]ELUDLQQDPHVWLWHYHOHNWULþQH
RSUHPH6YHWLONHLQLQãWDODFLMHUD]VYHWOMDYH,(&VSUHPHQMHQ
Low-voltage electrical installations - Part 5-559: Selection and erection of electrical
equipment - Luminaires and lighting installations
Errichten von Niederspannungsanlagen - Teil 5-559: Auswahl und Errichtung elektrischer
Betriebsmittel - Leuchten und Beleuchtungsanlagen
Installations électriques à basse tension - Partie 5-559: Choix et mise en œuvre des
matériels électriques - Luminaires et installations d'éclairage
Ta slovenski standard je istoveten z: HD 60364-5-559:2012
ICS:
29.140.50 Instalacijski sistemi za Lighting installation systems
razsvetljavo
91.140.50 Sistemi za oskrbo z elektriko Electricity supply systems
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
HARMONIZATION DOCUMENT
HD 60364-5-559
DOCUMENT D'HARMONISATION
May 2012
HARMONISIERUNGSDOKUMENT
ICS 91.140 Supersedes HD 60364-5-559:2005 + corr. Oct.2007
English version
Low-voltage electrical installations -
Part 5-559: Selection and erection of electrical equipment -
Luminaires and lighting installations
(IEC 60364-5-55:2011, modified)
Installations électriques à basse tension - Errichten von Niederspannungsanlagen -
Partie 5-559: Choix et mise en œuvre des Teil 5-559: Auswahl und Errichtung
matériels électriques - elektrischer Betriebsmittel -
Luminaires et installations d'éclairage Leuchten und Beleuchtungsanlagen
(CEI 60364-5-55:2011, modifiée) (IEC 60364-5-55:2011, modifiziert)
This Harmonization Document was approved by CENELEC on 2012-03-14. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for implementation of this
Harmonization Document at national level.
Up-to-date lists and bibliographical references concerning such national implementations may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.
This Harmonization Document exists in three official versions (English, French, German).
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland, Turkey and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. HD 60364-5-559:2012 E
Foreword
The text of document (64/1805/FDIS (CLAUSE 559)), future edition 2 of IEC 60364-5-55, prepared by
IEC TC 64, "Electrical installations and protection against electric shock", was submitted to the
IEC-CENELEC parallel vote and approved by CENELEC as HD 60364-5-559:2012.
A draft amendment, which covers common modifications to IEC 60364-5-55 (64/1805/FDIS (CLAUSE 559)),
was prepared by CLC/TC 64 "Electrical installations and protection against electric shock" and approved by
CENELEC.
The following dates are fixed:
(dop) 2013-03-14
• latest date by which the document has
to be implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2015-03-14
• latest date by which the national
standards conflicting with the
document have to be withdrawn
This document supersedes HD 60364-5-559:2005 + corr. Oct.2007.
HD 60364-5-559:2005 + corr. Oct.2007:
– additional requirements for connection of luminaires to the fixed wiring;
– modification of requirements regarding the fixing of luminaires;
– inclusion of alternative solutions for connecting devices used for through wiring and for connection of
luminaires to the supply;
– withdrawal of Clause 556, as HD 60364-5-56 now covers this matter.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights.
Endorsement notice
The text of the International Standard IEC 60364-5-55:2011 was approved by CENELEC as a European
Standard with agreed common modifications.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60079 series NOTE Harmonized in EN 60079 series.
IEC 60155:1993 NOTE Harmonized as EN 60155:1995 (not modified).
IEC 60309 series NOTE Harmonized as EN 60309 series.
IEC 60332-1-1:2004 NOTE Harmonized as EN 60332-1-1:2004 (not modified).
IEC 60332-1-2:2004 NOTE Harmonized as EN 60332-1-2:2004 (not modified).
IEC 60364-1:2005 NOTE Harmonized as HD 60364-1:2008 (modified)
IEC 60364-5-52:2009 NOTE Harmonized as HD 60364-5-52:2011 (modified)
IEC 60598-1:2008 NOTE Harmonized as EN 60598-1:2008 (modified)
IEC 60598-2-14 NOTE Harmonized as EN 60598-2-14.
IEC 61140 NOTE Harmonized as EN 61140.
IEC 61241 series NOTE Harmonized in EN 61241 series.
– 3 – HD 60364-5-559:2012
IEC 61347-1:2007 NOTE Harmonized as EN 61347-1:2008 (modified)
IEC 61557-12 NOTE Harmonized as EN 61557-12.
IEC 61558-2-6:2009 NOTE Harmonized as EN 61558-2-6:2009 (not modified).
IEC 61995 series NOTE Harmonized in EN 61995 series
COMMON MODIFICATIONS
559.3 General requirements for installations
Replace note 2 by:
NOTE 2 Concerning the correct selection of the protection and control devices, information about the currents (starting current,
harmonics, leakage current, primary ignition current, etc.) generated by the lamps should be provided.
Add Annexes ZA and ZB as follows:
– 5 – HD 60364-5-559:2012
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60050-195 - International Electrotechnical Vocabulary (IEV) - -
-
Chapter 195: Earthing and protection against
electric shock
IEC 60050-826 - International Electrotechnical Vocabulary - Part - -
826: Electrical installations
IEC 60079 Series Explosive atmospheres EN 60079 Series
IEC 60245-3 - Rubber insulated cables - Rated voltages up to - -
and including 450/750 V -
Part 3: Heat resistant silicone insulated cables
IEC 60331-11 - Tests for electric cables under fire conditions - - -
Circuit integrity -
Part 11: Apparatus - Fire alone at a flame
temperature of at least 750 °C
IEC 60331-21 - Tests for electric cables under fire conditions - - -
Circuit integrity -
Part 21: Procedures and requirements - Cables
of rated voltage up to an dincluding 0,6/1,0 kV
IEC 60364-1 (mod) 2005 Low-voltage electrical installations - HD 60364-1 2008
+ corr. August 2009 Part 1: Fundamental principles, assessment of
general characteristics, definitions
IEC 60364-4-41 2005 Low-voltage electrical installations - HD 60364-4-41 2007
(mod) Part 4-41: Protection for safety - Protection + corr. July 2007
against electric shock
IEC 60364-4-42 - Low voltage electrical installations - HD 60364-4-42 -
Part 4-42: Protection for safety - Protection
against thermal effects
IEC 60364-4-43 - Low voltage electrical installations - HD 60364-4-43 -
Part 4-43: Protection for safety - Protection
against overcurrent
IEC 60364-5-53 2001 Electrical installations of buildings - - -
Part 5-53: Selection and erection of electrical
equipment - Isolation, switching and control
IEC 60364-7-712 - Electrical installations of buildings - HD 60364-7-712 -
Part 7-712: Requirements for special
installations or locations - Solar photovoltaic
(PV) power supply systems
IEC 60364-7-717 - Low-voltage electrical installations - HD 60364-7-717 -
Part 7-717: Requirements for special
installations or locations - Mobile or
transportable units
IEC 60570 - Electrical supply track systems for luminaires EN 60570 -
Publication Year Title EN/HD Year
IEC 60598 Series Luminaires EN 60598 Series
IEC 60598-2-13 2006 Luminaires - EN 60598-2-13 2006
Part 2-13: Particular requirements - Ground + corr. December 2006
recessed luminaires
IEC 60598-2-22 1997 Luminaires - EN 60598-2-22 1998
(mod) Part 2-22: Particular requirements - Luminaires + corr. October 2007
for emergency lighting
IEC 60670 Series Boxes and enclosures for electrical accessories EN 60670 Series
for household and similar fixed electrical
installations
IEC 60670-21 - Boxes and enclosures for electrical accessories EN 60670-21 -
for household and similar fixed electrical
installations -
Part 21: Particular requirements for boxes and
enclosures with provision for suspension
means
IEC 60702-1 - Mineral insulated cables and their terminations EN 60702-1 -
with a rated voltage not exceeding 750 V -
Part 1: Cables
IEC 60702-2 - Mineral insulated cables and their terminations EN 60702-2 -
with a rated voltage not exceeding 750 V -
Part 2: Terminations
IEC 60998 Series Connecting devices for low-voltage circuits for EN 60998 Series
household and similar purposes
IEC 61048 2006 Auxiliaries for lamps - Capacitors for use in EN 61048 2006
tubular fluorescent and other discharge lamp
circuits - General and safety requirements
IEC 61535 - Installation couplers intended for permanent EN 61535 -
connection in fixed installation
IEC 61995 Series Devices for the connection of luminaires for EN 61995 Series
household and similar purposes
IEC 60417 Data Graphical symbols for use on equipment - -
base
ISO 8528-12 - Reciprocating internal combustion engine - -
driven alternating current generating sets - Part
12: Emergency power supply to safety services
– 7 – HD 60364-5-559:2012
Annex ZB
(normative)
Special national conditions
Special national condition: National characteristic or practice that cannot be changed even over a long
period, e.g. climatic conditions, electrical earthing conditions.
NOTE If it affects harmonization, it forms part of the Harmonization Document.
For the countries in which the relevant special national conditions apply these provisions are normative, for
other countries they are informative.
Clause Special national condition
559.5.1 United Kingdom
In the UK one of the following is also acceptable.
a) A ceiling rose to BS67
b) A luminaire supporting coupler to BS6972 or BS7001
c) A batten lamp holder or a pendant set to BS EN 60598
d) A luminaire to BS EN 60598
e) A suitable socket-outlet to BS 1363-2, BS546 or BS EN 60309-2
f) A plug-in lighting distribution unit to BS5733
g) A connection unit to BS 1363-4
h) Appropriate terminals enclosed in a box complying with BS 4662
Denmark
559.5.1
In Denmark, a luminaire supporting plug and socket-outlet system in accordance with
Information sheet, Electrical equipment no. 16/09 (Meddelelse el-materiel nr. 16/09) is
used.
Denmark
559.5.2
In Denmark the luminaire supporting means and its fixation to the structure of the building
shall ensure the minimal suspension of a load of 25 kg.
Denmark
559.5.3
In Denmark if no information is given in the luminaire manufacturer’s information sheet
regarding the current carrying value of the through wiring in the luminaire depending of
the installation method, the biggest fuse allowed up-stream in the installation is 10A,
which on the safe side corresponds to the current carrying capacity for a 1,5 mm Cu
conductor
In Denmark the third paragraph is replaced by the following requirement:
559.5.3
Cables for through wiring in luminaires prepared for through wiring but not delivered by
the manufacturer, shall be selected in accordance with the manufacturer’s instruction
sheet.
NOTE In accordance to EN 60598-1 if special cables or sleeves, e.g. due to high temperatures,
are necessary, the through wiring shall always be factory assembled.
Germany
559.5.5
In Germany, groups of luminaires divided between the three line conductors of a three-
phase circuit with only one common neutral conductor shall be provided with at least one
device isolating simultaneously all line conductors.
559.10
Austria and Germany
In Austria and Germany, Table A.1 of EN 60598-2-13:2006 is included for information.
Austria and Germany
Annex B
In Austria and Germany, Table B.1 apply.
Table B.1 – Selection of luminaires and lamp controlgear according to the location and
surface of installation [ for Annex B; Germany; Clause 559.4 ; There is a use of the
following selection]
Annex B
Austria and Germany
In Austria and Germany, Table B.2 applies.
Table B.2 – Explanation of additional symbols used for luminaires and controlgear for
lamps
– 9 – HD 60364-5-559:2012
Luminaires with fluorescent lamps suitable for installation in and on
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.