EN 60630:1998/A3:1999
(Amendment)Maximum lamp outlines for incandescent lamps
Maximum lamp outlines for incandescent lamps
EN following parallel vote
Maximale Lampen-Hüllkurven für Glühlampen
Encombrement maximal des lampes à incandescence
Maximum lamp outlines for incandescent lamps
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-marec-2001
Maximum lamp outlines for incandescent lamps
Maximum lamp outlines for incandescent lamps
Maximale Lampen-Hüllkurven für Glühlampen
Encombrement maximal des lampes à incandescence
Ta slovenski standard je istoveten z: EN 60630:1998/A3:1999
ICS:
29.140.20 Žarnice z žarilno nitko Incandescent lamps
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
NORME CEI
INTERNATIONALE
IEC
INTERNATIONAL
STANDARD
AMENDEMENT 3
AMENDMENT 3
1999-07
Amendement 3
Encombrement maximal des lampes
à incandescence
Amendment 3
Maximum lamp outlines for
incandescent lamps
Les feuilles de cet amendement sont à insérer
dans la Publication 60630 (1994)
The sheets contained in this amendment are to be
inserted in Publication 60630 (1994)
IEC 1999 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
C
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
INSTRUCTIONS POUR L'INSERTION DES INSTRUCTIONS FOR THE INSERTION
NOUVELLES PAGES ET FEUILLES DE OF NEW PAGES AND SHEETS
NORMES DANS LA PUBLICATION 60630 IN PUBLICATION 60630
1. Retirer les pages existantes 11, 12, 13, 14 et 1. Remove the existing pages 11, 12, 13, 14
insérer les nouvelles pages 11, 12, 13 et 14. and insert in their place new pages 11, 12,
13 and 14.
2. Retirer les feuilles existantes 2. Remove existing sheets
60630-IEC-1510-1, 60630-IEC-1540-2 60630-IEC-1510-1, 60630-IEC-1540-2
et les remplacer par les nouvelles feuilles and insert in their place new sheets
60630-IEC-1510-2 60630-IEC-1510-2
60630-IEC-1540-3 60630-IEC-1540-3
AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 34A: Lampes, du comité d'études 34
de la CEI: Lampes et équipements associés.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
34A/861/FDIS 34A/875/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
___________
FOREWORD
This amendment has been prepared by subcommittee 34A: Lamps, of IEC technical committee 34:
Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34A/861/FDIS 34A/875/RVD
Full information on the voting for the approval of this amendment can be found in the report on
voting indicated in the above table.
___________
NORME
CEI
INTERNATIONALE
IEC
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
1994-08
Modifiée selon les amendements 1 (1997), 2 (1998) et 3 (1999)
Amended in accordance with Amendments 1 (1997), 2 (1998) and 3 (1999)
Encombrement maximal des lampes
à incandescence
Maximum lamp outlines for
incandescent lamps
Commission Electrotechnique Internationale
International Electrotechnical Commission
60630 Amend. 2 IEC:1998 – 11 –
SECTION 2 – LAMP OUTLINE DATA SHEETS
2.1 Introduction
The numbering system for data sheets is made up of four parts as follows:
– the first number represents the number of this standard (IEC 60630);
– the second part is the letter grouping "IEC";
– the third part is the basic data sheet number from the series in the following table;
– the fourth part is a number indicating the edition of the sheet.
NOTE – When amendments are made to data sheets, the affected pages are issued with an updated edition number.
For example, data sheet 60630-IEC-1010-1 has been amended and its new issue number is 60630-IEC-1010-2.
The sequence of the data sheets is by "wattage" within the following subdivisions:
Category Data sheet numbers
Lamps with caps B15, B22, E14, E27 and E39/E40* 1000 - 1499
Reflector lamps with caps B22, E14 and E27 1500 - 1999
Lamps with caps E26/24** 2000 - 2499
2500 - 2999
Reflector lamps with caps E26/24** and E26/53×39
Lamps with caps E26/25** 3000 - 3499
Reflector lamps with caps E17 and E26/25** 3500 - 3999
Tungsten halogen lamps 4000 - 4499
* The combined sheets for E39 and E40 capped lamps will be split up (under consideration).
** There are two variations of E26 caps which are not fully compatible. In this standard, separate references are
made to E26/24 caps used in North America and E26/25 caps used in Japan.
– 12 – 60630 amend. 3 CEI:1999
2.2 Liste de types particuliers de lampes inclus dans la présente norme
Feuille n° Description Puissance(s) typique(s) Culot
60630-IEC-1010 Forme poire/A60-PS60 25 W, 40 W, 60 W, 100 W B22d/25x26
60630-IEC-1020 Forme poire/A60-PS60 25 W, 40 W, 60 W, 100 W E27/27
60630-IEC-1030 Forme poire/A80-PS80 150 W B22d/25x26
60630-IEC-1040 Forme poire/A80-PS80 150 W, 200 W E27/27
60630-IEC-1050 Forme poire/A90-PS90 300 W E27/27
60630-IEC-1060 Forme poire/A90-PS90 300 W E39/41, E40/41
60630-IEC-1070 Forme poire/A110-PS110 300 W, 500 W E39/41, E40/45
60630-IEC-1080 Forme poire/A130-PS130 1 000 W E39/41, E40/45
60630-IEC-1090 Forme poire/A150-PS150 1 000 W E39/41, E40/45
60630-IEC-1100 Forme poire/A170-PS170 1 500 W E39/41, E40/45
60630-IEC-1110 Forme champignon/M60 40 W, 60 W, 100 W B22d/25x26
60630-IEC-1115 Forme champignon/M50 40 W, 60 W B22d/25x26
60630-IEC-1120 Forme champignon/M60 40 W, 60 W, 100 W E27/27
60630-IEC-1125 Forme champignon/M50 40 W, 60 W E27/27
60630-IEC-1130 Forme champignon/M75 150 W B22d/25x26
60630-IEC-1140 Forme champignon/M75 150 W E27/27
60630-IEC-1150 Forme sphérique/P45 – B22d/22, B22d/25x26
60630-IEC-1160 Forme sphérique/P45 – E27/27
60630-IEC-1170 Forme sphérique/P45 – B15d/24x17
60630-IEC-1180 Forme sphérique/P45 – E14/25x17
60630-IEC-1190 Forme flamme/B35 – B22d/22, B22d/25x26
60630-IEC-1200 Forme flamme/B35 – E27/27
60630-IEC-1210 Forme flamme/B35 – B15d/24x17
60630-IEC-1220 Forme flamme/B35 – E14/25x17
60630-IEC-1250 Lampe poirette/S26 15 W, 25 W E14/25x17
60630-IEC-1260 Lampe poirette/S28 10 W, 15 W, 25 W E14/25x17
60630-IEC-1270 Lampe poirette/S28 10 W, 15 W, 25 W B15d/24x17, B15d/27x22
60630-IEC-1280 Lampe poirette/S28 10 W, 15 W, 25 W B22d/22
60630-IEC-1310 Lampe tubulaire/T17 10 W, 15 W, 25 W E14/20
60630-IEC-1320 Lampe tubulaire/T17 10 W, 15 W, 25 W B15d/19
60630-IEC-1330 Lampe tubulaire/T20 15 W, 25 W E14/23x15
60630-IEC-1340 Lampe tubulaire/T22 15 W, 20 W, 25 W E14/25x17
60630-IEC-1350 Lampe tubulaire/T22 15 W, 20 W, 25 W B15d/19
60630-IEC-1360 Lampe tubulaire/T25 15 W, 25 W E14/25x17
60630-IEC-1370 Lampe tubulaire/T25 15 W, 25 W B22d/22
60630-IEC-1380 Lampe tubulaire/T25 15 W, 25 W, 40 W E14/25x17
60630-IEC-1390 Lampe tubulaire/T25 15 W, 25 W, 40 W B15d/24x17
60630-IEC-1400 Lampe tubulaire/T25 15 W, 25 W, 40 W B22
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.