Low pressure sodium vapour lamps - Performance specifications

States the methods of test to be used for determining the characteristics of low pressure sodium vapour lamps of the integral type, both U-shaped and linear, operating on a.c. mains, 50 Hz or 60 Hz.

Natriumdampf-Niederdrucklampen - Anforderungen an die Arbeitsweise

Lampes à vapeur de sodium à basse pression - Prescriptions de performance

States the methods of test to be used for determining the characteristics of low pressure sodium vapour lamps of the integral type, both U-shaped and linear, operating on a.c. mains, 50 Hz or 60 Hz.

Low pressure sodium vapour lamps – Performance specification (IEC 60192:2001)

General Information

Status
Published
Publication Date
29-Jul-2001
Withdrawal Date
30-Jun-2004
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available - Publishing
Start Date
30-Jul-2001
Completion Date
30-Jul-2001

Relations

Buy Standard

Standard
EN 60192:2002
English language
30 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST EN 60192:2002

STANDARD
december 2002
Low pressure sodium vapour lamps – Performance specification (IEC 60192:2001)
ICS 29.140.30 Referenčna številka
SIST EN 60192:2002(en)
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD EN 60192
NORME EUROPÉENNE
EUROPÄISCHE NORM July 2001
ICS 29.140.30 Supersedes EN 60192:1993 + A4:1995 + A5:1995
English version
Low pressure sodium vapour lamps –
Performance specifications
(IEC 60192:2001)
Lampes à vapeur de sodium à basse Natriumdampf-Niederdrucklampen -
pression – Anforderungen an die Arbeitsweise
Prescriptions de performance (IEC 60192:2001)
(CEI 60192:2001)
This European Standard was approved by CENELEC on 2001-07-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway,
Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60192:2001 E

---------------------- Page: 2 ----------------------

EN 60192:2001 - 2 -
Foreword
The text of document 34A/953/FDIS, future edition 3 of IEC 60192, prepared by SC 34A, Lamps, of
IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was
approved by CENELEC as EN 60192 on 2001-07-01.
This European Standard supersedes EN 60192:1993 + A4:1995 + A5:1995.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2002-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2004-07-01
Annexes designated "normative" are part of the body of the standard.
Annexes designated "informative" are given for information only.
In this standard, annexes A, B and ZA are normative and annex C is informative.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 60192:2001 was approved by CENELEC as a European
Standard without any modification.
__________

---------------------- Page: 3 ----------------------

- 3 - EN 60192:2001
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited at the appropriate places in the text and the
publications are listed hereafter. For dated references, subsequent amendments to or revisions of any
of these publications apply to this European Standard only when incorporated in it by amendment or
revision. For undated references the latest edition of the publication referred to applies (including
amendments).
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year
1)
IEC 60050-845 - International Electrotechnical --
Vocabulary (IEV)
Chapter 845: Lighting
1) 2)
IEC 60061-1 - Lamp caps and holders together with EN 60061-1 1993
(mod) gauges for the control of
interchangeability and safety
Part 1: Lamp caps
1) 2)
IEC 60923 - Auxiliaries for lamps - Ballasts for EN 60923 1996
discharge lamps (excluding tubular
fluorescent lamps) - Performance
requirements
1) 2)
IEC 62035 (mod) - Discharge lamps (excluding fluorescent EN 62035 2000
lamps) - Safety specifications

1)
undated reference.
2)
valid edition at date of issue.

---------------------- Page: 4 ----------------------

NORME CEI
INTERNATIONALE IEC
60192
INTERNATIONAL
Troisième édition
STANDARD
Third edition
2001-05
Lampes à vapeur de sodium à basse pression –
Prescriptions de performance
Low-pressure sodium vapour lamps –
Performance
...

Questions, Comments and Discussion