Detail Specification: Rectangular connectors - Flat contacts, 0,8 mm thickness, locking screw not detachable

This standard covers a range of rectangular connectors with flat contacts, 0,8 mm thickness, locking screw not detachable, intended for use in industrial installations for connection or termination of sub-assemblies or components in electrical equipment in measuring, regulating and control circuits, in equipment for power supply, in fluid and air power system and components and other electronic devices employing similar techniques.

Bauartspezifikation: Rechteckige Steckverbinder - Flachkontakte mit 0,8 mm Dicke, unverlierbare Verriegelungsschraube

Diese Norm beschreibt eine Reihe von rechteckigen Steckverbindern mit Flachkontakten 0,8 mm dick und unverlierbarer Verriegelungsschraube für die Anwendung in betriebstechnischen Anlagen zur Verbindung oder zum Anschluss von Baugruppen oder Bauelementen in elektrischen Einrichtungen, in Mess-, Regel- oder Steuerkreisen, in Einrichtungen für die Stromversorgung, in System der Luft- und Fluidtechnik sowie Bauteilen und anderen elektronischen Bauelementen, die bei ähnlichen Techniken eingesetzt werden.

Spécification particulière: Connecteurs rectangulaires - Contacts plats, épaisseur de 0,8 mm, vis d'arrêt non détachable

La présente norme couvre une gamme de connecteurs rectangulaires avec des contacts plats, d'une épaisseur de 0,8 mm, et une vis de verrouillage imperdable, destinés à être utilisés dans les installations industrielles pour la connexion ou pour équiper les sorties des sous-ensembles ou des composants des équipements électriques des circuits de mesure, de régulation et de commande, des équipements pour l'alimentation électrique, des systèmes hydrauliques et à air comprimé et des composants et autres dispositifs électroniques utilisant des techniques similaires.

Podrobna specifikacija: Tektakotni konektorji - Ploščati kontakti, debeli 0,8 mm, neodstranljivi zaskočni vijak

General Information

Status
Published
Publication Date
28-Aug-2006
Withdrawal Date
30-Sep-2008
Technical Committee
CLC/SR 48B - Connectors
Drafting Committee
IEC/SC 48B - IEC_SC_48B
Parallel Committee
IEC/SC 48B - IEC_SC_48B
Current Stage
9093 - Decision to confirm - Review Enquiry
Start Date
12-Jun-2024
Completion Date
23-Sep-2025

Relations

Effective Date
28-Jan-2023

Overview

EN 175301-803:2006 is a CLC (CENELEC) detail specification for rectangular connectors with flat contacts (0.8 mm thickness) and a non‑detachable locking screw. It standardizes a family of 2‑ or 3‑pole connectors plus a protective earth (PE) contact intended for industrial installations and electrical equipment used in measuring, regulating and control circuits, power supply equipment, fluid/air power systems and similar electronic devices.

Key topics and technical requirements

  • Contact construction: flat contacts, thickness 0.8 mm; contact finish options referenced in style designation.
  • Contact arrangements: 2 + PE and 3 + PE variants; mating dimensions and insert positions defined for styles A, B and C.
  • Termination methods: screw and solder terminations (style‑dependent). Maximum conductor cross sections specified (style A/B up to 1.5 mm²; style C up to 0.75 mm²).
  • Mechanical styles & mounting: multiple variants for fixed (K, L, M, S, P) and free connectors (H, R) with detailed mounting dimensions and fixing hole configurations.
  • Environmental & electrical performance:
    • Climatic category: specified per EN 60068‑1 (e.g. -25 °C to +125 °C; damp heat conditions noted).
    • Degree of protection: IP65 in mated and locked condition (EN 60529).
    • Clearance & creepage: minimum 3 mm clearance and 3.2 mm creepage; rated impulse withstand voltage 4 kV (pollution degree 3).
    • Voltage proof: 2 kV r.m.s. (contact/contact and contact/test panel) per EN 60512.
    • Current carrying: derating curves and test requirements included (EN 60512 references).
  • Marking & materials: manufacturer ID, EN type designation, contact position marking, and polymer identification per EN ISO 1043.
  • Quality & testing: defined test schedule, sample sizes and qualification/inspection procedures; assessment levels B and G referenced.

Applications and practical use

  • Selection and design of panel‑mount and cable‑outlet rectangular connectors for industrial control cabinets, sensors, actuators, power supplies and pneumatics/hydraulics control equipment.
  • Definition of mating dimensions, panel cutouts and mounting details for mechanical and electrical integration.
  • Specification for procurement and supplier qualification where connector interchangeability, IP65 sealing, electrical safety (clearance/creepage) and test verification are required.
  • Basis for product testing, type approval and conformity assessment under assessed‑quality connector programs.

Who uses this standard

  • Electrical and mechanical design engineers, product managers, procurement specialists, connector manufacturers and test laboratories working on industrial control systems and equipment requiring standardized rectangular connectors.

Related standards

  • EN 61076‑1, EN 61076‑3 (connector family and sectional specs)
  • EN 60512 (connector tests), EN 60529 (IP code), EN 60664‑1 (insulation coordination), EN 60999‑1 (screw clamping)

Keywords: EN 175301-803:2006, rectangular connectors, flat contacts 0.8 mm, locking screw not detachable, IP65, clearance and creepage, industrial connectors, connector mating dimensions.

Frequently Asked Questions

EN 175301-803:2006 is a standard published by CLC. Its full title is "Detail Specification: Rectangular connectors - Flat contacts, 0,8 mm thickness, locking screw not detachable". This standard covers: This standard covers a range of rectangular connectors with flat contacts, 0,8 mm thickness, locking screw not detachable, intended for use in industrial installations for connection or termination of sub-assemblies or components in electrical equipment in measuring, regulating and control circuits, in equipment for power supply, in fluid and air power system and components and other electronic devices employing similar techniques.

This standard covers a range of rectangular connectors with flat contacts, 0,8 mm thickness, locking screw not detachable, intended for use in industrial installations for connection or termination of sub-assemblies or components in electrical equipment in measuring, regulating and control circuits, in equipment for power supply, in fluid and air power system and components and other electronic devices employing similar techniques.

EN 175301-803:2006 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 175301-803:2006 has the following relationships with other standards: It is inter standard links to EN 175301-803:1999. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase EN 175301-803:2006 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.

Standards Content (Sample)


6,67(16/29(16.,MDQXDU67$1'$5'LVWRYHWHQ(13RGUREQDVSHFLILNDFLMD7HNWDNRWQLNRQHNWRUML3ORãþDWLNRQWDNWLGHEHOLPPQHRGVWUDQOMLYL]DVNRþQLYLMDN'HWDLO6SHFLILFDWLRQ7HFWDQJXODUFRQQHFWRUV)ODWFRQWDFWVPPWKLFNQHVVORFNLQJVFUHZQRWGHWDFKDEOH !"#$%&'( )&!*- . 5HIHUHQþQDãWHYLOND6,67(1HQ,&6

EUROPEAN STANDARD EN 175301-803 NORME EUROPÉENNE
EUROPÄISCHE NORM August 2006
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2006 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 175301-803:2006 E
ICS 31.220.10 Supersedes EN 175301-803:1999
English version
Detail Specification: Rectangular connectors -
Flat contacts, 0,8 mm thickness, locking screw not detachable
Spécification particulière:
Connecteurs rectangulaires -
Contacts plats, épaisseur de 0,8 mm, vis d'arrêt non détachable
Bauartspezifikation:
Rechteckige Steckverbinder - Flachkontakte mit 0,8 mm Dicke, unverlierbare Verriegelungsschraube
This European Standard was approved by CENELEC on 2005-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.

(dop)
2007-03-01 – latest date by which the national standards conflicting with the EN have to be withdrawn
(dow)
2008-10-01 __________
- 3 - EN 175301-803:2006 Contents Page 1 General information.4 2 Normative references.4 3 Style designation.6 4 Common features.7 4.1 Isometric view.7 4.2 Mating information.7 4.3 Survey of styles.8 5 Dimensions.9 5.1 General.9 5.2 Fixed connector.10 5.3 Free connector.15 5.4 Marking.18 5.5 Contacts termination.19 5.6 Mounting dimensions.20 6 Characteristics.22 6.1 Climatic category.22 6.2 Electrical characteristics.22 6.3 Mechanical characteristics.23 7 Test schedule.23 7.1 General.23 7.2 Group P (preliminary).24 7.3 Groups AP, BP and CP.25 8 Quality assessment procedures.26 8.1 Qualification approval testing.26 8.2 Quality conformance inspection.27 8.3 Delayed delivery, re-inspection.28 9 Ordering information.28

ELECTRONIC COMPONENTS OF ASSESSED QUALITY – DETAIL SPECIFICATION IN
ACCORDANCE WITH
EN 61076-1:1995 EN 175301-803 issue 2
___________________________________________ Page 4 of 28 pages see Clause 5 for dimensions
Detail specification for rectangular connectors, flat con-tacts, 0,8 mm thickness, locking screw not detachable. 2 or 3 contacts + protective earth (PE) contact Termination: Screw, solder
Assessment levels: B and G (*) Climatic category:
see 6.1 Electrical characteristics:
see 6.2
Mechanical characteristics: see 6.3 Ordering information:
see clause 9 (*) see clauses 7 and 8 Information about manufacturer who have components qualified to this detail specification is available in the current CECC 00 200: (Register of Firms, Products and Services Approved under the CECC System).1 General information This standard covers a range of rectangular connectors with flat contacts, 0,8 mm thickness, locking screw not detachable, intended for use in industrial installations for connection or termination of sub-assemblies or components in electrical equipment in measuring, regulating and control circuits, in equipment for power supply, in fluid and air power system and components and other electronic devices employing similar techniques. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2591 1992 Aerospace series – Elements of electrical and optical connection – Test methods – General EN 60068-1 1994 Environmental testing – Part 1: General and guidance
(IEC 60068-1:1988 + corrigendum October 1988 + A1:1992) EN 60512 Series Connectors for electronic equipment – Test and measurements
(IEC 60512 series)
- 5 - EN 175301-803:2006 EN 60529 1991 Degrees of protection provided by enclosures (IP Code)
(IEC 60529:1989) EN 60664-1 2003 Insulation co-ordination for equipment within low-voltage systems – Part 1: Principles, requirements and tests (IEC 60664-1:1992 + A1:2000 + A2:2002) EN 60999-1 2000 Connecting devices - Electrical copper conductors – Safety requirements for screw-type and screwless-type clamping units – Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) (IEC 60999-1:1999) EN 61076-1 1995 Connectors with assessed quality, for use in d.c., low frequency analogue and in digital high-speed data applications – Part 1: Generic specification - Capability approval (IEC 61076-1:1995) EN 61076-3 2000 Connectors for use in d.c., low-frequency analogue and digital high-speed data applications – Part 3: Rectangular connectors with assessed quality - Sectional specification (IEC 61076-3:1999) EN 175300 1996 Sectional Specification: Rectangular connectors for frequencies below 3 MHzEN ISO 1043-1 2001 Plastics – Symbols and abbreviated terms – Part 1: Basic polymers and their special characteristics (ISO 1043-1:2001) EN ISO 1043-2 2001 Plastics – Symbols and abbreviated terms – Part 2: Fillers and reinforcing materials (ISO 1043-2:2000) EN ISO 6743-4 2001 Lubricants, industrial oils and related products (class L) – Classification – Part 4: Family H (Hydraulic systems) (ISO 6743-4:1999) IEC 60410 1973 Sampling plans and procedures for inspections by attributes IEC 60417 Database Graphical symbols for use on equipment IEC 60760 A1 1989 1993 Flat, quick-connect terminations

NOTE
“L” stands for letter
”N” stands for number EXAMPLES Fixed connector style A, having 3 male contacts with tin-alloy contact finish with solder
terminations.
Variant M assessment level G: EN 175301-803-A003MS-M3-G Free connector style , having 2 female contacts with silver-alloy contact finish with screw terminations. Variant H cable outlet on contact 3 (D) and cable outlet dia 6,5 and assessment level B: EN 175301-803-A002FA-H2D08-B

- 7 - EN 175301-803:2006 4 Common features 4.1 Isometric view
Figure 1 – Isometric view 4.2 Mating information
Arrow indicate mating direction
Figure 2 – Mating information
Variant L, square, 4 fixing holes, front mounting
Variant M, square, 1 fixing screw, front mounting
Variant S, round, for potting, rear mounting (tube)
Variant P, rectangular, 1 fixing screw

- 9 - EN 175301-803:2006 4.3.1.2 Free connectors (female contacts) Variant H, free connector
Variant R, free connector, non-rewirable
5 Dimensions 5.1 General Dimensions in mm are original. Drawings are shown in the first angle projection. The shape of the connectors may deviate from those given in the following drawings as long as the specified dimensions are not influenced. Missing dimensions shall be chosen according to common characteristics and the intended use.

1) Version 2 contacts + protective earth without contact Nr. 3 2) Boundary step, optional Figure 3 – Mating dimensions, 2 and 3 contacts + protective earth; Variants K, L, M and S

- 11 - EN 175301-803:2006 5.2.1.1 Variant K, square, 2 fixing holes, front mounting
1) Upon agreement between manufacturer and user Figure 4 – Connector style A, variant K, square, 2 fixing holes
5.2.1.2 Variant L, square, 4 fixing holes, front mounting
1) Upon agreement between manufacturer and user Figure 5 – Connector style A, variant L, square, 4 fixing holes

1) Upon agreement between manufacturer and user Figure 6 – Connector style A, variant M, square, 1 fixing hole
5.2.1.4 Variant S, round for potting, rear mounting (tube) solder termination
Figure 7 – Connector style A, variant S

- 13 - EN 175301-803:2006 5.2.2 Conn
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

記事のタイトル:EN 175301-803:2006 - 詳細仕様:矩形コネクター - フラットコンタクト、厚さ0.8 mm、取り外し不可能なロックネジ 記事の内容:この規格は、厚さ0.8 mmのフラットコンタクトを持つ矩形コネクターの範囲をカバーしており、取り外し不可能なロックネジを持つ工業用設置のために、電気機器の部品やサブアセンブリの接続や終端、測定、制御回路、電源装置、流体および空気動力システム、および同様の技術を使用する他の電子機器に使用することを目的としています。

The article discusses the EN 175301-803:2006 standard, which outlines specifications for rectangular connectors with flat contacts that have a thickness of 0.8 mm. These connectors have a non-detachable locking screw and are designed for use in various industrial applications. They are used to connect or terminate sub-assemblies or components in electrical equipment, measuring and control circuits, power supply equipment, fluid and air power systems, and other electronic devices.

제목: EN 175301-803:2006 - 상세 사양: 직사각형 커넥터 - 평판 접점, 0.8mm 두께, 잠금 나사 비탈착 내용: 이 표준은 평판 접점으로 구성된 0.8mm 두께의 직사각형 커넥터에 대한 사양을 다루고 있다. 이 커넥터는 잠금 나사가 비탈착인 산업용 설치를 위해 만들어졌으며, 전기 장비의 부분 또는 구성요소 연결 또는 종료, 측정, 조절 회로, 전력 공급 장치, 유체 및 공기 동력 시스템 및 유사한 기술을 사용하는 다른 전자기기에 사용된다.