Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement

Superseded by EN 55011:2009

Industrielle, wissenschaftliche und medizinische Hochfrequenzgeräte (ISM-Geräte) - Funkstörungen - Grenzwerte und Messverfahren

Appareils industriels, scientifiques et médicaux (ISM) à fréquence radioélectrique - Caractéristiques de perturbations électromagnétiques - Limites et méthodes de mesure

Industrijska, znanstvena in medicinska (ISM) radiofrekvenčna oprema - Karakteristike občutljivosti za radijske motnje - Mejne vrednosti in merilne metode (CISPR 11:2003/A2:2006)

General Information

Status
Withdrawn
Publication Date
28-Mar-2007
Withdrawal Date
31-Oct-2009
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Sep-2012
Completion Date
01-Sep-2012

Relations

Buy Standard

Amendment
EN 55011:2007/A2:2007
English language
7 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 55011:2007/A2:2007
01-oktober-2007
,QGXVWULMVND]QDQVWYHQDLQPHGLFLQVND ,60 UDGLRIUHNYHQþQDRSUHPD
.DUDNWHULVWLNHREþXWOMLYRVWL]DUDGLMVNHPRWQMH0HMQHYUHGQRVWLLQPHULOQHPHWRGH
&,635$
Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic
disturbance characteristics - Limits and methods of measurement
Industrielle, wissenschaftliche und medizinische Hochfrequenzgeräte (ISM-Geräte) -
Funkstörungen - Grenzwerte und Messverfahren
Appareils industriels, scientifiques et médicaux (ISM) a fréquence radioélectrique -
Caractéristiques de perturbations électromagnétiques - Limites et méthodes de mesure
Ta slovenski standard je istoveten z: EN 55011:2007/A2:2007
ICS:
33.100.10 Emisija Emission
SIST EN 55011:2007/A2:2007 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD
EN 55011/A2

NORME EUROPÉENNE
March 2007
EUROPÄISCHE NORM

ICS 33.100.10


English version


Industrial, scientific and medical (ISM) radio-frequency equipment -
Electromagnetic disturbance characteristics -
Limits and methods of measurement
(CISPR 11:2003/A2:2006)


Appareils industriels,  Industrielle, wissenschaftliche
scientifiques et médicaux (ISM) und medizinische Hochfrequenzgeräte
à fréquence radioélectrique - (ISM-Geräte) -
Caractéristiques de perturbations Funkstörungen -
électromagnétiques - Grenzwerte und Messverfahren
Limites et méthodes de mesure (CISPR 11:2003/A2:2006)
(CISPR 11:2003/A2:2006)




This amendment A2 modifies the European Standard EN 55011:2007; it was approved by CENELEC on
2006-11-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 55011:2007/A2:2007 E

---------------------- Page: 2 ----------------------

EN 55011:2007/A2:2007 - 2 -
Foreword
The text of document CISPR/B/394/FDIS, future amendment 2 to CISPR 11:2003, prepared by
CISPR SC B, Interference relating to industrial, scientific and medical radio-frequency apparatus, to other
(heavy) industrial equipment, to overhead power lines, to high voltage equipment and to electric traction,
was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A2 to
EN 55011:2007 on 2006-11-01.
The following dates were fixed:
– latest date by which the amendment has to be
implemented at national level by publication of
an identical national standard or by endorsement (dop) 2007-11-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2009-11-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of amendment 2:2006 to the International Standard CISPR 11:2003 was approved by CENELEC
as an amendment to the European Standard without any modification.
__________

---------------------- Page: 3 ----------------------

- 3 - EN 55011:2007/A2:2007
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications


Addition to Annex ZA of EN 55011:2007:

Publication Year Title EN/HD Year

CISPR 16-4-2 2003 Specification for radio disturbance and EN 55016-4-2 2004
immunity measuring apparatus and methods -
Part 4-2: Uncertainties, statistics and limit
modelling - Uncertainty in EMC
measurements

---------------------- Page: 4 ----------------------

INTERNATIONAL


CISPR
ELECTROTECHNICAL


11
COMMISSION



2003



AMENDMENT 2
2006-06


INTERNATIONAL SPECIAL COMMITTEE ON RADIO
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.