Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Uncertainty in EMC measurements

This part of CISPR 16 is designated a basic standard, which specifies the manner in which measurement uncertainty is to be taken in to account in determining compliance with CISPR limits. The material is also relevant to any EMC test when interpretation of the results and conclusions reached will be impacted by the uncertainty of the instrumentation used during the testing. Annex A contains the background material used in providing the amount of measurement uncertainty found in generating the CISPR values shown in Clause 4 and hence provides valuable background material for those needing both initial and further information on measurement uncertainty and how to take into account individual uncertainties in the measurement chain. The annex however is not intended to be a tutorial of user manual or to be copied when making uncertainty calculations. CISPR 16-1, CISPR 16-2, CISPR 16-3 and CISPR 16-4 have been reorganised into 14 parts, to accommodate growth and easier maintenance. This first edition of CISPR 16-4-2 cancels and replaces the first edition of CISPR 16-4 published in 2002. It contains the clauses of CISPR 16-4 without technical changes.

Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Teil 4-2: Unsicherheiten, Statistik und Modelle zur Ableitung von Grenzwerten (Störmodell) - Unsicherheit bei EMV-Messungen

Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques - Partie 4-2: Incertitudes, statistiques et modélisation des limites - Incertitudes de mesure CEM

La présente partie de la CISPR 16 est une norme fondamentale qui spécifie la manière dont il faut prendre en compte les incertitudes de mesure lors de la détermination de la conformité aux limites du CISPR. Cela s'applique également à tous les essais CEM lorsque les interprétations des résultats et les conclusions peuvent être influencées par l'incertitude de l'instrumentation utilisée pendant les essais. L'annexe A contient les informations utilisées pour fournir la valeur de l'incertitude de mesure CISPR donnée à l'article 4 et, en conséquence, fournit des informations importantes pour ceux qui ont besoin à la fois de l'information initiale et de l'information complémentaire sur les incertitudes de mesure et sur la façon de prendre en compte les incertitudes individuelles dans la chaîne de mesure. Toutefois, l'annexe A n'est pas destinée à être un modèle de manuel d'utilisateur ou à être recopiée lors des calculs d'incertitude. Les publications CISPR 16-1, CISPR 16-2, CISPR 16-3 and CISPR 16-4 ont été réorganisées en 14 parties, dans le but de pouvoir gérer plus facilement leur évolution et maintenance. Cette première édition de la CISPR 16-4-2 annule et remplace la CISPR 16-4 publiée en 2002. Elle contient les articles de la CISPR 16-4 sans modifications de leur contenu technique.

Specifikacija za merilne naprave in metode za merjenje radijskih motenj in odpornosti – 4-2. del: Modeliranje negotovosti, statistike in mejnih vrednosti – Negotovost pri meritvah EMC (CISPR 16-4-2:2003)

General Information

Status
Withdrawn
Publication Date
21-Oct-2004
Withdrawal Date
31-Aug-2007
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
13-Jul-2014
Completion Date
13-Jul-2014

Relations

Buy Standard

Standard
EN 55016-4-2:2005
English language
25 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-julij-2005
Specifikacija za merilne naprave in metode za merjenje radijskih motenj in
odpornosti – 4-2. del: Modeliranje negotovosti, statistike in mejnih vrednosti –
Negotovost pri meritvah EMC (CISPR 16-4-2:2003)
Specification for radio disturbance and immunity measuring apparatus and methods --
Part 4-2: Uncertainties, statistics and limit modelling - Uncertainty in EMC measurements
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur
Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit -- Teil
4-2: Unsicherheiten, Statistik und Modelle zur Ableitung von Grenzwerten (Störmodell) -
Unsicherheit bei EMV-Messungen
Spécifications des méthodes et des appareils de mesure des perturbations
radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 4-2:
Incertitudes, statistiques et modélisation des limites - Incertitudes de mesure CEM
Ta slovenski standard je istoveten z: EN 55016-4-2:2004
ICS:
17.220.20 0HUMHQMHHOHNWULþQLKLQ Measurement of electrical
PDJQHWQLKYHOLþLQ and magnetic quantities
33.100.01 Elektromagnetna združljivost Electromagnetic compatibility
na splošno in general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 55016-4-2
NORME EUROPÉENNE
EUROPÄISCHE NORM October 2004

ICS 33.100.10; 33.100.20
English version
Specification for radio disturbance and immunity measuring
apparatus and methods
Part 4-2: Uncertainties, statistics and limit modelling –
Uncertainty in EMC measurements
(CISPR 16-4-2:2003)
Spécifications des méthodes  Anforderungen an Geräte und
et des appareils de mesure Einrichtungen sowie Festlegung der
des perturbations radioélectriques Verfahren zur Messung der
et de l'immunité aux perturbations hochfrequenten Störaussendung
radioélectriques (Funkstörungen) und Störfestigkeit
Partie 4-2: Incertitudes, statistiques Teil 4-2: Unsicherheiten, Statistik
et modélisation des limites – und Modelle zur Ableitung von
Incertitudes de mesure CEM Grenzwerten (Störmodell) –
(CISPR 16-4-2:2003) Unsicherheit bei EMV-Messungen
(CISPR 16-4-2:2003)
This European Standard was approved by CENELEC on 2004-09-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 55016-4-2:2004 E
Foreword
The text of the International Standard CISPR 16-4-2:2003, prepared by CISPR SC A, Radio-
interference measurements and statistical methods, was submitted to the formal vote and was
approved by CENELEC as EN 55016-4-2 on 2004-09-01 without any modification.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2005-09-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2007-09-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard CISPR 16-4-2:2003 was approved by CENELEC as a European
Standard without any modification.
__________
- 3 - EN 55016-4-2:2004
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
Publication Year Title EN/HD Year
CISPR 16-1 Series Specification for radio disturbance and EN 55016-1 Series
immunity measuring apparatus and
methods
Part 1: Radio disturbance and immunity
measuring apparatus
CISPR 16-2 Series Part 2: Methods of measurement of EN 55016-2 Series
disturbances and immunity
1)
CISPR/TR 16-3 - Part 3: CISPR technical reports - -

1)
CISPR/TR 16-4-1 - Part 4-1: Uncertainties, statistics and - -
limit modeling - Uncertainties in
standardized EMC tests
1)
CISPR/TR 16-4-3 - Part 4-3: Uncertainties, statistics and - -
limit modelling - Statistical
considerations in the determination of
EMC compliance of mass-produced
products
1)
CISPR/TR 16-4-4 - Part 4-4: Uncertainties, statistics and - -
limit modeling - Statistics of complaints
and a model for the calculation of limits

1)
Undated reference.
COMMISSION
CISPR
ELECTROTECHNIQUE
16-4-2
INTERNATIONALE
INTERNATIONAL
Première édition
ELECTROTECHNICAL
First edition
2003-11
COMMISSION
COMITÉ INTERNATIONAL SPÉCIAL DES PERTURBATIONS RADIOÉLECTRIQUES
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
Spécifications des méthodes et des appareils
de mesure des perturbations radioélectriques et
de l'immunité aux perturbations radioélectriques –
Partie 4-2:
Incertitudes, statistiques et modélisation des
limites – Incertitudes de mesure CEM
Specification for radio disturbance and immunity
measuring apparatus and methods –
Part 4-2:
Uncertainties, statistics and limit modelling –
Uncertainty in EMC measurements
” IEC 2003 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale S
PRICE CODE
International Electrotechnical Commission
ɆɟɠɞɭɧɚɪɨɞɧɚɹɗɥɟɤɬɪɨɬɟɯɧɢɱɟɫɤɚɹɄɨɦɢɫɫɢɹ
Pour prix, voir catalogue en vigueur
For price, see current catalogue

CISPR 16-4-2 ” IEC:2003 – 3 –
CONTENTS
FOREWORD.5
INTRODUCTION.7
TABLE RECAPITULATING CROSS-REFERENCES .9
1 Scope.11
2 Normative references .11
3 Definitions and symbols.13
3.1 General symbols .13
3.2 Measurands .13
3.3 Input quantities.13
4 Measurement instrumentation uncertainty .15
4.1 Overview .15
4.2 Quantities to be considered for conducted disturbance measurements at a
mains port .17
4.3 Quantities to be considered for disturbance power measurements.17
4.4 Quantities to be considered for radiated disturbance measurements of
electric field strength on an open area test site or alternative test site .17
Annex A (informative) Basis for U values in Table 1.21
cispr
Bibliography.43

CISPR 16-4-2 ” IEC:2003 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
____________
SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY
MEASURING APPARATUS AND METHODS –
Part 4-2: Uncertainties, statistics and limit modelling –
Uncertainty in EMC measurements
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard CISPR 16-4-2 has been prepared by CISPR subcommittee A: Radio
interference measurements and statistical methods.
This first edition of CISPR 16-4-2 cancels and replaces the first edition of CISPR 16-4
published in 2002. It contains the clauses of CISPR 16-4 without technical changes.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until
2006. At this date, the publication will be
x reconfirmed;
x withdrawn;
x replaced by a revised edition, or
x amended.
CISPR 16-4-2 ” IEC:2003 – 7 –
INTRODUCTION
CISPR 16-1, CISPR 16-2, CISPR 16-3 and CISPR 16-4 have been reorganised into 14 parts,
to accommodate growth and easier maintenance. The new parts have also been renumbered.
See the list given below.
Old CISPR 16 publications New CISPR 16 publications
Measuring apparatus
CISPR 16-1-1
CISPR 16-1-2 Ancillary equipment – Conducted disturbances
Radio disturbance
and immunity
Ancillary equipment – Disturbance power
CISPR 16-1-3
CISPR 16-1
measuring
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.