Explosive atmospheres - Part 17: Electrical installations inspection and maintenance

This part of IEC 60079 applies to users and covers factors directly related to the inspection and maintenance of electrical installations within hazardous areas only, where the hazard may be caused by flammable gases, vapours, mists, dusts, fibres or flyings. It does not apply to underground mining areas, areas where a risk can arise due to the presence of hybrid mixtures, dusts of explosives that do not require atmospheric oxygen for combustion, and pyrophoric substances. The significant technical changes with respect to the previous edition are as follows: Additional requirements for inspection and maintenance of electrical installations for combustible dusts and Equipment Protection Levels have been introduced and are explained in the new Annex C.

Explosionsfähige Atmosphäre - Teil 17: Prüfung und Instandhaltung elektrischer Anlagen

Atmosphères explosives - Partie 17: Inspection et entretien des installations électriques

La présente partie de la CEI 60079 s'applique aux utilisateurs et couvre les facteurs directement liés à l'inspection et à l'entretien des seules installations électriques situées à l'intérieur des emplacements dangereux, où le risque peut venir des gaz, des vapeurs, des brouillards, des poussières, des fibres ou des particules en suspension inflammables. Elle ne s'applique pas aux parties souterraines des mines, aux emplacements où il existe un danger dû à la présence de mélanges hybrides, aux poussières d'explosif qui n'exigent pas d'oxygène de l'air pour leur combustion, et aux substances pyrophoriques. Les modifications importantes par rapport à l'édition antérieure sont indiquées ci-dessous: Des exigences supplémentaires pour l'inspection et l'entretien d'installations électriques pour les poussières combustibles sont incluses, et Des ' niveaux de protection des équipements ' ont été introduits et sont expliqués dans la nouvelle Annexe C.

Eksplozivne atmosfere - 17. del: Pregledovanje in vzdrževanje električnih inštalacij (IEC 60079-17:2007)

General Information

Status
Withdrawn
Publication Date
13-Sep-2007
Withdrawal Date
31-Aug-2010
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
24-Dec-2016

Relations

Buy Standard

Standard
EN 60079-17:2008
English language
40 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60079-17:2008
01-januar-2008
1DGRPHãþD
SIST EN 60079-17:2003
SIST EN 61241-17:2005
(NVSOR]LYQHDWPRVIHUHGHO3UHJOHGRYDQMHLQY]GUåHYDQMHHOHNWULþQLKLQãWDODFLM
,(&
Explosive atmospheres -- Part 17: Electrical installations inspection and maintenance
Explosionsfähige Atmosphäre - Teil 17: Prüfung und Instandhaltung elektrischer Anlagen
Atmosphères explosives -- Partie 17: Inspection et entretien des installations électriques
Ta slovenski standard je istoveten z: EN 60079-17:2007
ICS:
29.260.20 (OHNWULþQLDSDUDWL]D Electrical apparatus for
HNVSOR]LYQDR]UDþMD explosive atmospheres
91.140.50 Sistemi za oskrbo z elektriko Electricity supply systems
SIST EN 60079-17:2008 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60079-17:2008

---------------------- Page: 2 ----------------------

SIST EN 60079-17:2008


EUROPEAN STANDARD
EN 60079-17
NORME EUROPÉENNE
September 2007
EUROPÄISCHE NORM

ICS 29.260.20 Supersedes EN 60079-17:2003 and EN 61241-17:2005
Incorporates corrigendum July 2008


English version


Explosive atmospheres -
Part 17: Electrical installations inspection and maintenance
(IEC 60079-17:2007)


Atmosphères explosives -  Explosionsfähige Atmosphäre -
Partie 17: Inspection et entretien Teil 17: Prüfung und Instandhaltung
des installations électriques elektrischer Anlagen
(CEI 60079-17:2007) (IEC 60079-17:2007)




This European Standard was approved by CENELEC on 2007-09-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia,
Slovenia, Spain, Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60079-17:2007 E

---------------------- Page: 3 ----------------------

SIST EN 60079-17:2008
EN 60079-17:2007 - 2 -
Foreword
The text of document 31J/145/FDIS, future edition 4 of IEC 60079-17, prepared by SC 31J, Classification
of hazardous areas and installation requirements, of IEC TC 31, Equipment for explosive atmospheres,
was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60079-17 on
2007-09-01.
This European Standard supersedes EN 60079-17:2003 and 61241-17:2005.
The significant technical changes with respect to EN 60079-17:2003 are as follows:
– additional requirements for inspection and maintenance of electrical installations for combustible dusts
are included;
– knowledge, skills and competencies of "responsible persons", "technical persons with executive
function" and "operatives" are explained in new Annex B;
– Equipment Protection Levels (EPLs) have been introduced and are explained in the new Annex C.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2008-06-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2010-09-01
Annex ZA has been added by CENELEC.
The contents of the corrigendum of July 2008 have been included in this copy.
__________
Endorsement notice
The text of the International Standard IEC 60079-17:2007 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60079-6 NOTE  Harmonized as EN 60079-6:2007 (not modified).
IEC 60079-7 NOTE  Harmonized as EN 60079-7:2007 (not modified).
IEC 60079-18 NOTE  Harmonized as EN 60079-18:2004 (not modified).
IEC 60079-26 NOTE  Harmonized as EN 60079-26:2007 (not modified).
IEC 60079-28
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.