Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 1: General requirements

Superseded by EN 50264-1:2008

Bahnanwendungen - Kabel und Leitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Standard Isolierwanddicken - Teil 1: Allgemeine Anforderungen

Applications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des performances particulières de comportement au feu - Câbles à isolation d'épaisseur normale - Partie 1: Prescriptions générales

Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 1: General requirements

General Information

Status
Withdrawn
Publication Date
22-Aug-2002
Withdrawal Date
30-Jun-2008
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Mar-2011
Completion Date
01-Mar-2011

Relations

Buy Standard

Standard
EN 50264-1:2003
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Railway applications - Railway rolling stock cables having special fire performance - Standard wall - Part 1: General requirementsBahnanwendungen - Kabel und Leitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Standard Isolierwanddicken -- Teil 1: Allgemeine AnforderungenApplications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des performances particulières de comportement au feu - Câbles à isolation d'épaisseur normale -- Partie 1: Prescriptions généralesRailway applications - Railway rolling stock cables having special fire performance - Standard wall -- Part 1: General requirements45.060.01Železniška vozila na splošnoRailway rolling stock in general29.060.20KabliCables13.220.20Fire protectionICS:Ta slovenski standard je istoveten z:EN 50264-1:2002SIST EN 50264-1:2003en01-februar-2003SIST EN 50264-1:2003SLOVENSKI
STANDARD
EUROPEAN STANDARDEN 50264-1NORME EUROPÉENNEEUROPÄISCHE NORMAugust 2002CENELECEuropean Committee for Electrotechnical StandardizationComité Européen de Normalisation ElectrotechniqueEuropäisches Komitee für Elektrotechnische NormungCentral Secretariat: rue de Stassart 35, B - 1050 Brussels© 2002 CENELEC -All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Ref. No. EN 50264-1:2002 EICS 13.220.20; 29.060.20; 45.060.01English versionRailway applications -Railway rolling stock cables having special fire performance -Standard wallPart 1: General requirementsApplications ferroviaires -Câbles pour matériel roulant ferroviaireayant des performances particulièresde comportement au feu -Câbles à isolation d'épaisseur normalePartie 1: Prescriptions généralesBahnanwendungen -Kabel und Leitungen für Schienen-fahrzeuge mit verbessertem Verhaltenim Brandfall -Standard IsolierwanddickenTeil 1: Allgemeine AnforderungenThis European Standard was approved by CENELEC on 2002-03-01. CENELEC members are bound tocomply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving thisEuropean Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained onapplication to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in anyother language made by translation under the responsibility of a CENELEC member into its ownlanguage and notified to the Central Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta,Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.SIST EN 50264-1:2003

- 3 -EN 50264-1:2002ContentsPageIntroduction.41
Scope.52
Normative references.53
Definitions.64
Rated voltage.75
Marking.86
General requirements for the construction of cables.97
Electrical
performance.138
Reaction to fire - Cables.139
Reaction to fire - Components.14Bibliography.21Figure 1 - Example of marking.9Table 1 - Rated voltages.8Table 2 - Requirements for the tests for non halogenated insulating compounds.16Table 3 - Requirements for test for fillers, tapes and binders.18Table 4 - Requirements for the tests for non halogenated sheathing compounds.19SIST EN 50264-1:2003

and reliable when properly used,-to state the characteristics, performance, and construction requirements directly orindirectly bearing on safety,-to specify methods for checking conformity with these requirements.EN 50264, which covers a range of cables rated at up to 3,6/6 kV with conductor sizes1,0 mm2 up to 400 mm2, is divided into 3 parts:Part 1: General requirements;Part 2: Single core cables;Part 3: Multicore cables.These cables are intended for a limited number of applications. Further information onthese applications is given in the guide to use (EN 50355 – under development).Special test methods referred to in EN 50264 are given in EN 50305.A separate European Standard, EN 50306 covers cables for similar applications but withthin wall insulation, restricted to 300 V rating and a maximum conductor size of 2,5 mm2.SIST EN 50264-1:2003

- 5 -EN 50264-1:20021ScopePart 1 of EN 50264 specifies the general requirements applicable to the cables given inpart 2 and part 3 of EN 50264. It includes the detailed requirements for the insulating andsheathing materials and other components called up in the separate parts.
In particularEN 50264-1 specifies those requirements relating to fire safety which enable the cables tosatisfy Hazard Levels 2, 3 and 4 of EN 45545-1.NOTE 1
Requirements for the emission of smoke and gases are not specified for Hazard Level 1 ofEN 45545-1.NOTE 2
EN 45545-1 is still under development and should be consulted.Based on proven experience and reliability over many years these cables are rated foroccasional thermal stresses causing ageing equivalent to continuous operational life at atemperature of 90 oC. The maximum temperature for short circuit conditions is 200 oC basedon a duration of 5 seconds.This part 1 should be used in conjunction with the other parts of EN 50264.2Normative referencesThis European Standard incorporates by dated or undated reference, provisions from otherpublications. These normative references are cited at the appropriate places in the text andthe publications are listed hereafter. For dated references, subsequent amendments to orrevisions of these references apply to this European Standard only when incorporated in itby amendment or revision. For undated references the latest edition of the publicationreferred to applies.EN 10002-1Tensile testing of metallic materials - Method of test at ambienttemperatureEN 45545-11)Railway applications - Fire protection of railway vehicles -Part 1: GeneralEN 50264-2Railway applications - Railway rolling stock cables having special fireperformance - Standard wall - Part 2: Single core cablesEN 50264-3Railway rolling stock cables having special fire performance - Standardwall - Part 3: Multicore cablesEN 50265-2-1Common test methods for cables under fire conditions - Test forresistance to vertical flame propagation for a single insulated conductoror cable - Part 2-1: Procedures - 1 kW pre-mixed flameEN 50266-2-4Common test methods for cables under fire conditions - Test for verticalflame spread of vertically-mounted bunched wires or cables -Part 2-4: Procedures - Category CEN 50267-2-1Common test methods for cables under fire conditions - Tests ongasses evolved during combustion of materials from cables -Part 2-1: Procedures - Determination of the amount of halogen acid gas
1) At draft stage.SIST EN 50264-1:2003

- 7 -EN 50264-1:20023.3type of compoundcategory, designated by one or several characteristics, in which a compound is placedaccording to its properties, as determined by specific testsNOTE
The type designation is not directly related to the composition of the compound. See also 6.2.1 and6.6.1.3.4halogen-free materialcombustible material which, when tested in accordance with the designated method,conforms to the following:maximum evolution of HCl-0,5 % to EN 50267-2-1minimum pH-4,3 to EN 50267-2-2maximum conductivity-10,0 S/mm to EN 50267-2-2NOTE
This value of maximum conductivity is subject to further consideration and review.maximum fluorine content-0,1 % to EN 60684-23.5type tests (Symbol T)tests required to be made before supplying a type of cable covered by this standard on ageneral commercial basis in order to demonstrate satisfactory performance characteristicsto meet the intended application. These tests are of such a nature that, after they havebeen made, they need not be repeated unless changes are made in the cable materials,design or type of manufacturing process which might change the performancecharacteristics3.6sample tests (Symbol S)tests made on samples of completed cable, or components taken from a completed cableadequate to verify that the finished product meets the design specification3.7routine tests (Symbol R)tests made on all complete cable lengths to demonstrate their integrity4Rated voltageThe rated voltage of a cable is the reference voltage for which the cable is designed, andwhich serves to define the electrical tests.The rated voltage V is expressed by the combination of the following values (in volts):Uo/U(Um)Uo is the r.m.s. value between any insulated conductor and earth, i.e. metalcovering of the cable or the surrounding medium, e.g.Uo = 600 V;Uis the r.m.s. value between any two phase-conductors of a multicore cableor of a system of single-core cables, e.g. U = 1 000 V;Umis the maximum r.m.s. value of the "highest system voltage" for which theequipment may be used, e.g.Um = 1 200 V.SIST EN 50264-1:2003
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.