EN 55014-2:1997/IS1:2007
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
Deals with the electromagnetic immunity of appliances and similar apparatus for household and similar purposes that use electricity, as well as electric toys and electric tools, the rated voltage of the apparatus being not more than 250 V for single-phase apparatus to be connected to phase and neutral, and 480 V for other apparatus. It specifies the immunity requirements in relation to continuous and transient, conducted and radiated electromagnetic disturbances, including electrostatic discharges, for the above-mentioned apparatus. Apparatus may incorporate motors, heating elements or their combination, may contain electric or electronic circuitry, and may be powered by the mains, by batteries, or by any other electrical power source. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered.
Elektromagnetische Verträglichkeit - Anforderungen an Haushaltgeräte, Elektrowerkzeuge und ähnliche Elektrogeräte - Teil 2: Störfestigkeit - Produktfamiliennorm
Compatibilité électromagnétique - Exigences pour les appareils électrodomestiques, outillages électriques et appareils analogues - Partie 2: Immunité - Norme de famille de produits
Elektromagnetna združljivost - Zahteve za (električne) gospodinjske aparate, električna ročna orodja in podobne aparate - 1. del: Oddajanje - Razlaga točke 8.4 standarda EN SIST 55014-2:1997 z A1:2001
Razlaga točke 8.4 standarda EN SIST 55014-2:1997 z A1:2001
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2007
(OHNWURPDJQHWQD]GUXåOMLYRVW=DKWHYH]DHOHNWULþQHJRVSRGLQMVNHDSDUDWH
HOHNWULþQDURþQDRURGMDLQSRGREQHDSDUDWHGHO2GGDMDQMH5D]ODJDWRþNH
VWDQGDUGD(16,67]$
Interpretation of Subclause 8.4 of EN 55014-2:1997 + A1:2001
Interpretation von 8.4 der EN 55014-2:1997 + A1:2001
Ta slovenski standard je istoveten z: EN 55014-2:1997/IS1:2007
ICS:
33.100.20 Imunost Immunity
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN 55014-2/IS1
Interpretation Sheet 1
EN 55014-2:1997
English version
___________
Foreword
This Interpretation Sheet to the European Standard EN 55014-2:1997 was prepared by the Interpretation
Panel of the Technical Committee CENELEC TC 210, Electromagnetic compatibility (EMC). The text of the
draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC on 2005-07-16.
Clause 8 Conditions during testing
Subclause 8.4: “The tests concerning e.m. fields and current injection are carried out during the scan time
while, at random, the selected modes of the EUT are set into operation. In addition, tests are performed at
five selected spot frequencies, each for up to 3 min at the selected modes of op
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.