EN 50122-2:1998
(Main)Railway applications - Fixed installations - Part 2: Protective provisions against the effects of stray currents caused by d.c. traction systems
Railway applications - Fixed installations - Part 2: Protective provisions against the effects of stray currents caused by d.c. traction systems
This standard specifies requirements for protective provisions against the effects of stray currents which result from the operation of d.c. traction systems. As experience for several decades has not shown evident corrosion effects from a.c. traction systems and actual investigations are not completed, this standard only deals with stray currents flowing from a d.c. traction system. This standard applies to all metallic fixed installations which form part of the traction system, and also to any other unrelated metallic components located in any position in the earth, which may carry stray currents resulting from the operation of the railway system. This standard applies to all new electrification of a d.c. railway system. The principles may also be applied to existing electrified systems where it is necessary to consider the effects of stray currents. 94
Bahnanwendungen - Ortsfeste Anlagen - Teil 2: Schutzmaßnahmen gegen die Auswirkungen von Streuströmen, verursacht durch Gleichstrombahnen
Applications ferroviaires - Installations fixes - Partie 2: Mesures de protection contre les effets des courants vagabonds issus de la traction électrique à courant continu
Železniške naprave – Stabilne naprave električne vleke – 2. del: Zaščitni ukrepi proti učinkom blodečih tokov, ki jih povzročajo enosmerni vlečni sistemi
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.VLVWHPLBahnanwendungen - Ortsfeste Anlagen -- Teil 2: Schutzmaßnahmen gegen die Auswirkungen von Streuströmen, verursacht durch GleichstrombahnenApplications ferroviaires - Installations fixes -- Partie 2: Mesures de protection contre les effets des courants vagabonds issus de la traction électrique à courant continuRailway applications - Fixed installations -- Part 2: Protective provisions against the effects of stray currents caused by d.c. traction systems29.280Electric traction equipment13.260Protection against electric shock. Live workingICS:Ta slovenski standard je istoveten z:EN 50122
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.