EN 50382-2:2008/A1:2013
(Amendment)Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C
Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C
2013-03-25 - Publication editing allocated to cpalagi@cencenelec.eu
2021: CLC legacy converted by DCLab NISOSTS
Bahnanwendungen - Hochtemperaturkabel und -leitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Teil 2: Einadrige silikonisolierte Leitungen für 120 °C oder 150 °C
Applications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des performances particulières de comportement au feu - Partie 2: Câbles monoconducteurs isolés au silicone pour 120 °C ou 150 °C
Železniške naprave - Visokotemperaturni močnostni kabli za železniška vozna sredstva, ki imajo posebne požarne lastnosti - 2. del: Enkrat oplaščeni kabli s silikonsko gumijasto izolacijo za 120 °C ali 150 °C
2. del standarda EN 50382 določa zahteve ter konstrukcije in dimenzije enojedrnih kablov naslednjih vrst in nazivnih napetosti: – 1,8/3 kV nezaslonjeni, neoklopljeni s tekstilnim opletom ali brez (1,5 mm² do 400 mm²); – 1,8/3 kV nezaslonjeni, oklopljeni (1,5 mm² do 400 mm²); – 3,6/6 kV nezaslonjeni, neoklopljeni s tekstilnim opletom ali brez (2,5 mm² do 400 mm²); – 3,6/6 kV nezaslonjeni, oklopljeni (2,5 mm² do 400 mm²). Vsi kabli imajo pokositrene ali navadne bakrene vodnike razreda 5 ali 6 za EN 60228, nehalogensko izolacijo in, kjer je ustrezno, nehalogenski oklop. Uporabljajo se pri železniških vozilih kot fiksno ožičenje ali ožičenje, kjer je upogibanje pri delovanju omejeno. Zahtevana je enakomerna temperatura vodnika, ki ne presega 120 °C ali 150 °C ter največja temperatura za kratkostične pogoje 250 °C ali 350 °C za trajanje 5 sekund. Ko se izolacijske spojine in oklop, določeni v tem standardu, ki so zmožni delovati pri 150 °C, uporabljajo s pokositrenimi vodniki, je največja obratovalna temperatura omejena na 120 °C in iz enakega tehničnega razloga je največja kratkostična temperatura omejena na 250 °C. Tudi izbira oklepa lahko omeji obratovalno temperaturo na 120 °C. V izolacijo je lahko vključen tekstilni oplet ali se uporabi na površini neoklopljenih kablov. Pri pogojih za razvoj požara imajo kabli posebne lastnosti, kar zadeva največje dovoljeno širjenje plamena ter največjo dovoljeno emisijo dima in strupenih plinov. Ta 2. del standarda EN 50382 se uporablja skupaj s 1. delom »Splošne zahteve«.
General Information
- Status
- Published
- Publication Date
- 06-Jun-2013
- Withdrawal Date
- 28-Apr-2016
- Technical Committee
- CLC/TC 20 - Electric cables
- Drafting Committee
- CLC/TC 20 - Electric cables
- Current Stage
- 6060 - Document made available - Publishing
- Start Date
- 07-Jun-2013
- Completion Date
- 07-Jun-2013
Relations
- Effective Date
- 28-Jan-2023
Overview
The EN 50382-2:2008/A1:2013 standard, published by CLC (European Committee for Electrotechnical Standardization), specifies requirements for railway rolling stock high temperature power cables with specialized fire performance. This Part 2 of the series focuses on single core silicone rubber insulated cables rated for continuous operation at temperatures of 120 °C or 150 °C. These cables are engineered for reliable performance in demanding railway environments where fire safety and high thermal resistance are critical.
This amendment (A1) updates the original 2008 standard to clarify temperature ratings and compliance details, effective for implementation from April 2014. The standard ensures consistent safety, quality, and interoperability of cables used in railway applications across European member states.
Key Topics
Scope of Application
Covers single core silicone rubber insulated power cables used in railway rolling stock that require enhanced fire resistance and high temperature operation (up to 120 °C by default, extendable to 150 °C by agreement).Temperature Ratings
Standard specifies cables designed for continuous operating temperatures of either 120 °C or 150 °C, with provisions for tinned conductors to reach higher temperature limits through purchaser-manufacturer agreement.Fire Performance
Emphasizes “special fire performance” to limit fire propagation, crucial for safety in railway vehicles.Material Specifications
Details use of silicone rubber for insulation to withstand elevated temperatures while maintaining electrical and mechanical integrity.Compliance and Implementation
Outlines national adoption deadlines and withdrawal of conflicting standards. Includes reference to patent considerations related to cable technologies.Multilingual and Multi-National Applicability
Documents are available in English, French, and German, with scope covering all CENELEC member countries for standardized use.
Applications
The EN 50382-2:2008/A1:2013 standard is essential for manufacturers, designers, and operators in the railway sector requiring:
- High temperature power cables for onboard electrical systems capable of continuous operation in hot or fire-prone environments.
- Fire-safe cable solutions to minimize risks of ignition and limit fire propagation within rolling stock interiors.
- Single core silicone rubber insulated cables for power distribution, control circuits, or instrumentation wiring on trains, trams, and metro cars.
- Compliance with European railway safety and interoperability regulations to ensure network-wide acceptance.
Industries and stakeholders benefiting from this standard include:
- Railway vehicle manufacturers
- Electrical cable producers
- Safety certification bodies
- Maintenance and retrofit service providers
Related Standards
EN 50382-2:2008/A1:2013 is part of a larger portfolio of railway cable standards and is related to:
- EN 50382-1: Covers multi-core cables with similar fire performance and temperature ratings.
- IEC 61375 Series: General standards for onboard electrical systems in railway vehicles.
- EN 45545: Railway applications - fire protection on railway vehicles (fire hazard testing).
- Other CENELEC standards on electrical cables and railway vehicle components.
For holistic fire safety and electrical performance compliance, coordination with these standards is recommended.
Keywords: railway rolling stock cables, high temperature power cables, silicone rubber insulation, fire performance cables, single core railway cables, EN 50382-2:2008/A1:2013, railway cable standards, CLC railway standards, fire-resistant railway cables, railway electrical safety.
Frequently Asked Questions
EN 50382-2:2008/A1:2013 is a amendment published by CLC. Its full title is "Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C". This standard covers: 2013-03-25 - Publication editing allocated to cpalagi@cencenelec.eu 2021: CLC legacy converted by DCLab NISOSTS
2013-03-25 - Publication editing allocated to cpalagi@cencenelec.eu 2021: CLC legacy converted by DCLab NISOSTS
EN 50382-2:2008/A1:2013 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 29.060.20 - Cables; 45.060.01 - Railway rolling stock in general. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 50382-2:2008/A1:2013 has the following relationships with other standards: It is inter standard links to EN 50382-2:2008. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase EN 50382-2:2008/A1:2013 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2013
äHOH]QLãNHQDSUDYH9LVRNRWHPSHUDWXUQLPRþQRVWQLNDEOL]DåHOH]QLãNDYR]QD
VUHGVWYDNLLPDMRSRVHEQHSRåDUQHODVWQRVWLGHO(QNUDWRSODãþHQLNDEOLV
VLOLNRQVNRJXPLMDVWRL]RODFLMR]Dƒ&DOLƒ&
Railway applications - Railway rolling stock high temperature power cables having
special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C
or 150 °C
Bahnanwendungen - Hochtemperaturkabel und -leitungen für Schienenfahrzeuge mit
verbessertem Verhalten im Brandfall - Teil 2: Einadrige silikonisolierte Leitungen für 120
°C oder 150 °C
Applications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des
performances particulières de comportement au feu - Partie 2: Câbles monoconducteurs
isolés au silicone pour 120 °C ou 150 °C
Ta slovenski standard je istoveten z: EN 50382-2:2008/A1:2013
ICS:
13.220.40 Sposobnost vžiga in Ignitability and burning
obnašanje materialov in behaviour of materials and
proizvodov pri gorenju products
29.060.20 Kabli Cables
45.060.01 Železniška vozila na splošno Railway rolling stock in
general
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50382-2/A1
NORME EUROPÉENNE
June 2013
EUROPÄISCHE NORM
ICS 13.220.40; 29.060.20; 45.060.01
English version
Railway applications -
Railway rolling stock high temperature power cables having special fire
performance -
Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C
Applications ferroviaires - Bahnanwendungen -
Câbles pour matériel roulant ferroviaire Hochtemperaturkabel und -leitungen für
ayant des performances particulières de Schienenfahrzeuge mit verbessertem
comportement au feu - Verhalten im Brandfall -
Partie 2: Câbles monoconducteurs isolés Teil 2: Einadrige silikonisolierte Leitungen
au silicone pour 120 °C ou 150 °C für 120 °C oder 150 °C
This amendment A1 modifies the European Standard EN 50382-2:2008; it was approved by CENELEC on 2013-
04-29. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate
the conditions for giving this amendment the status o
...