Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C

Part 2 of EN 50382 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: – 1,8/3 kV unscreened, unsheathed with or without textile braid (1,5 mm² to 400 mm²); – 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²); – 3,6/6 kV unscreened, unsheathed with or without textile braid (2,5 mm² to 400 mm²); – 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²). All cables have class 5 or class 6 tinned or plain copper conductors to EN 60228, halogen-free insulation and where applicable halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 120 °C or 150 °C and a maximum temperature for short circuit conditions of either 250 °C or 350 °C based on a duration of 5 s. When the insulating compounds and sheath specified in this standard which are thermally capable of operating at 150 °C are used with tinned conductors, the maximum operating temperature is limited to 120 °C and, for the same technical reason, the maximum short circuit temperature is limited to 250 °C. The choice of sheath may also limit the maximum operating temperature to 120 °C. A textile braid may be included in the insulation or applied at its surface to unsheathed cables. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. This Part 2 of EN 50382 should be used in conjunction with Part 1 “General requirements”.

Bahnanwendungen - Hochtemperaturkabel und -leitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Teil 2: Einadrige silikonisolierte Leitungen für 120 °C oder 150 °C

Teil 2 von EN 50382 legt Anforderungen an und Aufbauten und Abmessungen von einadrigen Leitungen für folgende Bauarten und Nennspannungen fest: – 1,8/3 kV ohne Schirm, ohne Mantel, mit oder ohne Textilgeflecht (1,5 mm2 bis 400 mm2); – 1,8/3 kV ohne Schirm, mit Mantel (1,5 mm2 bis 400 mm2); – 3,6/6 kV ohne Schirm, ohne Mantel, mit oder ohne Textilgeflecht (2,5 mm2 bis 400 mm2); – 3,6/6 kV ohne Schirm, mit Mantel (2,5 mm2 bis 400 mm2). Alle Leitungen haben einen verzinnten oder blanken Kupferleiter Klasse 5 oder Klasse 6 nach EN 60228, eine halogenfreie Isolierung und gegebenenfalls einen halogenfreien Mantel. Sie sind für feste Verlegung im Schienenfahrzeug bestimmt oder für Verdrahtungen, bei denen im Betrieb begrenzt mit Bewegungen gerechnet werden muss. Die Anforderungen berücksichtigen eine dauernde Leitertemperatur von nicht mehr als 120 °C oder 150 °C und eine maximale Kurzschlusstemperatur von entweder 250 °C oder 350 °C bei einer Dauer von 5 s. Wenn die in dieser Norm festgelegten Isoliermischungen und der Mantel für eine Betriebstemperatur von 150 °C geeignet sind, mit verzinnten Leitern verwendet werden, beträgt die maximale Betriebstemperatur 120 °C und aus denselben technischen Gründen ist die maximale Kurzschlusstemperatur bei verzinnten Kupferleitern auf 250 °C begrenzt. Durch die Wahl des Mantels kann die Betriebstemperatur auch auf 120 °C begrenzt werden. Ein Textilgeflecht darf sich in der Isolierung befinden oder auf der Oberfläche von Leitungen ohne Mantel aufgebracht werden. Unter Brandbedingungen zeigen die Leitungen besondere Leistungsmerkmale hinsichtlich der maximal zulässigen Weiterleitung der Flammen (Ausbreitung der Flammen) und der höchsten zulässigen Emission von Rauch und giftigen Gasen. . Teil 2 von EN 50382 sollte in Verbindung mit Teil 1 „Allgemeine Anforderungen“ benutzt werden.

Applications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des performances particulières de comportement au feu - Partie 2: Câbles monoconducteurs isolés au silicone pour 120 °C ou 150 °C

La présente Partie 2 de la EN 50382 spécifie les prescriptions, la construction et les dimensions, des câbles monoconducteurs de type et de tension assignée suivantes: – 1,8/3 kV non écrantés, non gainés, avec ou sans tresse textile (1,5 mm² à 400 mm²); – 1,8/3 kV non écrantés, gainés (1,5 mm² à 400 mm²); – 3,6/6 kV non écrantés, non gainés avec ou sans tresse textile (2,5 mm² à 400 mm²); – 3,6/6 kV non écrantés, gainés (2,5 mm² à 400 mm²). Tous les câbles possèdent une âme en cuivre étamé ou non, de classe 5 ou 6 selon la EN 60228, une enveloppe isolante sans halogènes et lorsqu’applicable, une gaine sans halogènes. Ils sont destinés aux installations fixes ou soumis à de faibles flexions en service des matériels roulants ferroviaires. Les prescriptions sont basées pour une température permanente de l’âme ne dépassant pas 120 °C ou 150 °C et à une température maximale de 250 °C ou 350 °C pour une durée de 5 s en cas de court-circuit. Bien que les matériaux d’isolation et de gainage spécifiés dans la présente norme soient thermiquement capables de fonctionner à 150 °C, la température de fonctionnement est limitée à 120 °C lorsque les âmes sont étamées et pour les mêmes raisons techniques, la température maximale de court-circuit est limitée à 250 °C pour les âmes étamées. Le choix de la gaine peut aussi limiter la température de fonctionnement à 120 °C. Une tresse textile peut être incluse dans l’enveloppe isolante ou appliquée en surface pour les câbles non gainés. Les câbles présentent, en cas d’incendie, des performances particulières de propagation maximale admissible de la flamme (longueur brûlée) et d’émission de fumées et de gaz toxiques. Il est recommandé d’utiliser la Partie 2 de la EN 50382 conjointement avec la Partie 1 “Prescriptions générales”.

Železniške naprave - Visokotemperaturni močnostni kabli za železniška vozna sredstva, ki imajo posebne požarne lastnosti - 2. del: Enkrat oplaščeni kabli s silikonsko gumijasto izolacijo za 120 °C ali 150 °C

General Information

Status
Published
Publication Date
19-Mar-2008
Technical Committee
CLC/TC 20 - Electric cables
Drafting Committee
IEC/TC 20 - IEC_TC_20
Parallel Committee
IEC/TC 20 - IEC_TC_20
Current Stage
9093 - Decision to confirm - Review Enquiry
Start Date
29-Sep-2021
Completion Date
23-Sep-2025

Relations

Effective Date
28-Jan-2023

Overview

EN 50382-2:2008 is a CLC (CENELEC) standard specifying requirements for single‑core silicone rubber insulated high‑temperature power cables used in railway rolling stock. It covers unsheathed and sheathed single‑core cables for rated voltages 1.8/3 kV and 3.6/6 kV, designed for continuous conductor temperatures of 120 °C or 150 °C and with defined short‑circuit temperature limits (5 s duration). The standard focuses on cables with halogen‑free insulation (and where applicable halogen‑free sheaths) that provide special fire performance in terms of flame propagation, smoke density and toxic gas emission.

Key topics and technical requirements

  • Cable types & ratings: 1.8/3 kV and 3.6/6 kV single‑core constructions; conductor cross‑sections from small signal sizes up to 400 mm² depending on type.
  • Conductors: Class 5 or class 6 copper conductors per EN 60228 - plain copper for 150 °C ratings, tinned copper typically used for 120 °C rated cables (special limitations apply when mixing materials).
  • Insulation & sheath compounds: Silicone rubber insulation compounds defined for extra/low temperature and oil resistance (compound types EI111/EI112); sheath compound choices (EM105/EM106/EM107) which may limit maximum operating temperature.
  • Thermal limits: Continuous conductor temperature 120 °C or 150 °C; short‑circuit peak temperatures of 250 °C or 350 °C for 5 s depending on construction and materials. Note: using certain insulating/sheath compounds with tinned conductors restricts the maximum operating temperature to 120 °C.
  • Fire performance: Limits on flame spread, smoke emission and toxic gas generation under fire conditions; defined test methods (referenced in EN 50305, EN 60332, EN 61034).
  • Constructional options: Permitted textile braid (internal or external), optional conductor screening, separator tapes and sheathed/unsheathed variants.
  • Marking & identification: Requirements for cable marking (EN reference, voltage, conductor size, code designation, conductor temperature) and color rules for insulation/sheath.
  • Testing: Comprehensive mechanical, electrical, ageing and fire tests (e.g., voltage, insulation resistance, hot‑set, ozone, mineral oil, low‑temperature and reaction‑to‑fire tests).

Applications and users

  • Intended for fixed wiring or limited‑flex wiring in railway rolling stock (locomotives, passenger trains, trams, metro).
  • Primary users: cable manufacturers, rolling stock OEMs, system integrators, procurement/specification engineers, testing laboratories and certification bodies, and installers seeking compliant high‑temperature, low‑smoke halogen‑free power cables.

Related standards

  • EN 50382-1 (General requirements)
  • EN 50305 (Test methods)
  • EN 50355 / EN 50343 (selection, installation, current ratings)
  • EN 60228 (conductors), EN 60332, EN 61034 (fire/smoke test methods)

EN 50382-2 is essential when specifying or certifying high‑temperature, fire‑resistant silicone insulated power cables for modern railway applications.

Frequently Asked Questions

EN 50382-2:2008 is a standard published by CLC. Its full title is "Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C". This standard covers: Part 2 of EN 50382 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: – 1,8/3 kV unscreened, unsheathed with or without textile braid (1,5 mm² to 400 mm²); – 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²); – 3,6/6 kV unscreened, unsheathed with or without textile braid (2,5 mm² to 400 mm²); – 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²). All cables have class 5 or class 6 tinned or plain copper conductors to EN 60228, halogen-free insulation and where applicable halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 120 °C or 150 °C and a maximum temperature for short circuit conditions of either 250 °C or 350 °C based on a duration of 5 s. When the insulating compounds and sheath specified in this standard which are thermally capable of operating at 150 °C are used with tinned conductors, the maximum operating temperature is limited to 120 °C and, for the same technical reason, the maximum short circuit temperature is limited to 250 °C. The choice of sheath may also limit the maximum operating temperature to 120 °C. A textile braid may be included in the insulation or applied at its surface to unsheathed cables. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. This Part 2 of EN 50382 should be used in conjunction with Part 1 “General requirements”.

Part 2 of EN 50382 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: – 1,8/3 kV unscreened, unsheathed with or without textile braid (1,5 mm² to 400 mm²); – 1,8/3 kV unscreened, sheathed (1,5 mm² to 400 mm²); – 3,6/6 kV unscreened, unsheathed with or without textile braid (2,5 mm² to 400 mm²); – 3,6/6 kV unscreened, sheathed (2,5 mm² to 400 mm²). All cables have class 5 or class 6 tinned or plain copper conductors to EN 60228, halogen-free insulation and where applicable halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 120 °C or 150 °C and a maximum temperature for short circuit conditions of either 250 °C or 350 °C based on a duration of 5 s. When the insulating compounds and sheath specified in this standard which are thermally capable of operating at 150 °C are used with tinned conductors, the maximum operating temperature is limited to 120 °C and, for the same technical reason, the maximum short circuit temperature is limited to 250 °C. The choice of sheath may also limit the maximum operating temperature to 120 °C. A textile braid may be included in the insulation or applied at its surface to unsheathed cables. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. This Part 2 of EN 50382 should be used in conjunction with Part 1 “General requirements”.

EN 50382-2:2008 is classified under the following ICS (International Classification for Standards) categories: 13.220.40 - Ignitability and burning behaviour of materials and products; 29.060.20 - Cables; 45.060.01 - Railway rolling stock in general. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 50382-2:2008 has the following relationships with other standards: It is inter standard links to EN 50382-2:2008/A1:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

You can purchase EN 50382-2:2008 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of CLC standards.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Railway applications - High temperature power cables for railway rolling stock and having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 C or 150 CApplications ferroviaires - Câbles pour matériel roulant ferroviaire ayant des performances particulières de comportement au feu - Partie 2: Câbles monoconducteurs isolés au silicone pour 120 °C ou 150 °CBahnanwendungen - Hochtemperaturkabel und -leitungen für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Teil 2: Einadrige silikonisolierte Leitungen für 120 °C oder 150 °C45.060.01Železniška vozila na splošnoRailway rolling stock in general29.060.20KabliCables13.220.40Sposobnost vžiga in obnašanje materialov in proizvodov pri gorenjuIgnitability and burning behaviour of materials and productsICS:SIST EN 50382-2:2008en,fr,deTa slovenski standard je istoveten z:EN 50382-2:200801-julij-2008SIST EN 50382-2:2008SLOVENSKI
STANDARD
EUROPEAN STANDARD EN 50382-2 NORME EUROPÉENNE
EUROPÄISCHE NORM March 2008
CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC -
All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 50382-2:2008 E
ICS 13.220.40; 29.060.20; 45.060.01
English version
Railway applications -
Railway rolling stock high temperature power cables
having special fire performance -
Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C
Applications ferroviaires -
Câbles pour matériel roulant ferroviaire ayant des performances particulières
de comportement au feu -
Partie 2: Câbles monoconducteurs isolés au silicone pour 120 °C ou 150 °C
Bahnanwendungen -
Hochtemperaturkabel und -leitungen
für Schienenfahrzeuge mit verbessertem Verhalten im Brandfall -
Teil 2: Einadrige silikonisolierte Leitungen für 120 °C oder 150 °C
This European Standard was approved by CENELEC on 2008-02-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom.

The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50382-2 on 2008-02-01. The following dates were fixed: – latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement
(dop)
2009-02-01 – latest date by which the national standards conflicting with the EN have to be withdrawn
(dow)
2011-02-01
–––––––––––––––––––
– 3 –
Code designation . 24 Bibliography . 25 Tables Table 1 – General data – Cable type 1,8/3 kV unsheathed (120 °C or 150 °C) . 10 Table 2 – General data – Cable type 1,8/3 kV sheathed (120 °C or 150 °C) . 11 Table 3 – General data – Cable type 3,6/6 kV unsheathed (120 °C or 150 °C) . 12 Table 4 – General data – Cable type 3,6/6 kV unsheathed with class 6 conductor
(120 °C or 150 °C) . 13 Table 5 – General data - Cable type 3,6/6 kV sheathed (120 °C or 150 °C) . 14 Table 6 – Minimum load of dynamic cut through . 20 Table 7 – Schedule of tests for cables . 21

– 5 –
This Part 2 of EN 50382 should be used in conjunction with Part 1 “General requirements”. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 10002-1 Metallic materials – Tensile testing – Part 1: Method of test (at ambient temperature) EN 50266-2-4 Common test methods for cables under fire conditions – Test for vertical flame spread of vertically-mounted bunched wires or cables – Part 2-4: Procedures – Category C EN 50266-2-5 Common test methods for cables under fire conditions – Test for vertical flame spread of vertically-mounted bunched wires or cables – Part 2-5: Procedures – Small cables - Category D EN 50305:2002 Railway applications – Railway rolling stock cables having special fire performance – Test methods
EN 50382-1 Railway applications – Railway rolling stock high temperature power cables having special fire performance – Part 1: General requirements EN 50395:2005 Electrical test methods for low voltage energy cables
EN 60228 Conductors of insulated cables (IEC 60228) EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions – Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame (IEC 60332-1-2)

test methods – Part 1–2: General application – Thermal ageing methods
(IEC 60811-1-2:1985 + A1:1989 + corr. May 1986) EN 60811-1-3:1995 Insulating and sheathing materials of electric and optical cables – Common test methods – Part 1-3: General application – Methods for determining the density – Water absorption tests – Shrinkage test (IEC 60811-1-3:1993) EN 60811-1-4:1995 Insulating and sheathing materials of electric and optical cables – Common test methods – Part 1–4: General application – Tests at low temperature (IEC 60811-1-4:1985 + A1:1993 + corr. May 1986) EN 60811-2-1:1998 Insulating and sheathing materials of electric and optical cables – Common test methods – Part 2–1: Methods specific to elastomeric compounds – Ozone resistance, hot set and mineral oil immersion tests
(IEC 60811-2-1:1998) EN 61034-2 Measurement of smoke density of cables burning under defined conditions – Part 2: Procedure and requirements (IEC 61034-2) HD 308 Identification of cores in cables and flexible cords 3 Definitions For the purposes of this document, the terms and definitions given in EN 50382-1 apply. 4 Rated voltage The rated voltage for single core silicone insulated cables shall be as follows: a) unsheathed: 1,8/3 kV; 3,6/6 kV; b) sheathed: 1,8/3 kV; 3,6/6 kV. 5 Marking and identification 5.1 Marking of cable Cables shall be marked with the following: – indication of origin; – EN reference; – voltage rating (Uo); – number of conductors and their size; – a code designation according to Annex A; – conductor temperature. An example of a complete mark for a sheathed cable is: *** EN50382-2 3600V 1x400 OF 150°C The marking shall conform to the requirements of EN 50382-1, Clause 5.

– 7 –
Other markings (e.g. batch number, year of manufacture) may be added upon agreement between manufacturer and user. 5.2 Colour identification 5.2.1 Insulation The insulation of unsheathed cables shall be black and that of sheathed cables white or neutral unless otherwise agreed between the manufacturer and purchaser. If a colour other than white or neutral is specified it shall be a colour in accordance with HD 308. The colour shall be clearly identifiable and durable. Durability shall be checked by the test given in EN 50305, 10.1. Conformity with these requirements shall be verified by visual examination. 5.2.2 Sheath The sheath shall be black unless otherwise agreed between the manufacturer and purchaser. 6 Construction of cables 6.1 General The cable shall conform to the applicable general requirements given in EN 50382-1, and to the specific requirements of this part. Conformity with the requirements shall be checked by inspection and by the tests given in Table 7. The cable dimensions shall be as given in Tables 1 to 5 as appropriate to the cable type. 6.2 Conductor For cables rated at 120 °C conductors shall be tinned annealed copper, class 5 or class 6, according to EN 60228. For cables rated at 150 °C conductors shall be plain annealed copper, class 5 or class 6, according to EN 60228. When tested in accordance with EN 10002-1 the minimum average elongation of wires from the conductor shall be 15 %, with a minimum value of 10 % for an individual wire. NOTE It is not necessary to test all individual wires. 5 % of wires or 10 wires, whichever is the fewer, should be selected at random. 6.3 Conductor screening For cables in Tables 3 to 5 it is permitted to use a conductor screen. When used it shall be as given in EN 50382-1, 6.1.6. 6.4 Separator It is permitted to place a non-hygroscopic separator tape of coloured material between the conductor and insulation if the cable construction does not include a conductor screen. If used, the separator tape shall be easily removable from the conductor. A separator may be included between the insulation and sheath.

6.7 Textile braid It is permitted to include a textile braid, either within the insulation or at its surface. When a textile braid is included in the construction of a cable, it shall consist of material compatible with the operating temperature (for example braid made of glass filaments shall be treated with a suitable substance in order to avoid fraying). When a braid is applied to the surface of the insulation a separator may be included between the insulation and braid. NOTE A braid may be included in the construction at the request of a customer.

– 9 –
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

기사 제목: EN 50382-2:2008 - 철도 차량에 사용되는 특수 화재 성능을 갖는 높은 온도 전력 케이블 - 파트 2: 120 °C 또는 150 °C용 단일 코어 실리콘 고무 절연 케이블 기사 내용: EN 50382-2의 제 2파트는 다음 유형과 전압 등급의 단일 코어 케이블에 대한 요구 사항, 구성 및 크기를 명시합니다. - 1,8 / 3 kV 비 스크린, 비 감싸움 텍스타일 브레이드와 함께 (1.5 mm² ~ 400 mm²); - 1,8 / 3 kV 비 스크린, 감싸움 (1.5 mm² ~ 400 mm²); - 3,6 / 6 kV 비 스크린, 비 감싸움 텍스타일 브레이드와 함께 (2.5 mm² ~ 400 mm²); - 3,6 / 6 kV 비 스크린, 감싸움 (2.5 mm² ~ 400 mm²). 모든 케이블은 EN 60228의 5급 또는 6급 틴 도금 또는 일반 구리 도체, 할로겐 없는 절연 및 해당 경우 할로겐 없는 외피를 갖습니다. 이들은 철도 차량의 고정 배선 또는 운영 중 제한된 굴곡이 발생하는 배선에 사용됩니다. 요구 사항은 연속 도체 온도가 120 °C 또는 150 °C 이하이며 최대 단락 조건의 온도는 5초 동안의 기간을 기준으로 250 °C 또는 350 °C입니다. 이 표준에서 명시한 절연 화합물과 외피가 틴 도체와 함께 사용되는 경우 최대 작동 온도는 120 °C로 제한되며, 동일한 기술적 이유로 최대 단락 온도는 250 °C로 제한됩니다. 외피의 선택도 최대 작동 온도를 120 °C로 제한할 수 있습니다. 텍스타일 브레이드는 절연에 포함되거나 비감싸움 케이블의 표면에 적용될 수 있습니다. 화재 조건에서 케이블은 최대 허용 화염 전파 (불길 퍼짐) 및 연기 및 유독 가스 배출에 대한 특수 성능 특성을 나타냅니다. 이 EN 50382의 제 2파트는 "일반 요구 사항"을 제공하는 제 1파트와 함께 사용되어야 합니다.

EN 50382-2:2008 is a standard that specifies the requirements, constructions, and dimensions of single core silicone rubber insulated cables for high temperature power applications in railway rolling stock. The standard covers various types and voltage ratings of cables, including those with or without textile braid and those that are unscreened or sheathed. The cables have tinned or plain copper conductors, halogen-free insulation, and halogen-free sheath where applicable. They are suitable for fixed wiring or wiring with limited flexing in railway rolling stock. The standard sets the maximum continuous conductor temperature at either 120 °C or 150 °C and the maximum temperature for short circuit conditions at either 250 °C or 350 °C. If the specified insulating compounds and sheath capable of operating at 150 °C are used with tinned conductors, the maximum operating temperature is limited to 120 °C. The choice of sheath may also limit the maximum operating temperature to 120 °C. The cables also exhibit special performance characteristics during fire conditions in terms of flame propagation and emission of smoke and toxic gases. This Part 2 of EN 50382 should be used in conjunction with Part 1, which provides the general requirements.

記事タイトル: EN 50382-2:2008 - 鉄道用 - 特別な防火性能を持つ高温電力ケーブル(部分2):120 ° Cまたは150 ° C用のシリコーンゴム1芯絶縁ケーブル 記事内容:EN 50382-2の第2部は、次のタイプと電圧定格の単心ケーブルに関する要件、構造、寸法を規定しています。- 1,8 / 3 kV非スクリーン、非覆われたテクスタイルブレード付き(1.5 mm²〜400 mm²); - 1,8 / 3 kV非スクリーン、覆われた(1.5 mm²〜400 mm²); - 3,6 / 6 kV非スクリーン、非覆われたテクスタイルブレード付き(2.5 mm²〜400 mm²); - 3,6 / 6 kV非スクリーン、覆われた(2.5 mm²〜400 mm²)。すべてのケーブルは、EN 60228のクラス5またはクラス6のチンメッキまたは無酸素銅導体、ハロゲンフリーの絶縁材料、該当する場合はハロゲンフリーの外被を持ちます。これらは、鉄道車両内の固定配線または運用中に限定的な曲げに遭遇する配線に使用されます。要件は、連続導体温度が120 ° Cまたは150 ° C以下であること、および最大短絡条件の温度が5秒間の期間を基準に250 ° Cまたは350 ° Cであることを想定しています。この規格で指定された絶縁体材料および外被は、ティンメッキ導体と使用される場合、最大動作温度は120 ° Cに制限され、同じ技術的理由で最大短絡温度は250 ° Cに制限されます。外被の選択は最大動作温度を120 ° Cに制限する場合もあります。非覆われたケーブルには、絶縁体にテキスタイルブレードを含めるか、表面に適用することができます。火災条件下では、ケーブルは炎の伝播(炎の広がり)の最大許容性と煙や有毒ガスの最大許容排出に特殊な性能を示します。このEN 50382の第2部は、一般要件を提供する第1部と併用する必要があります。