IEC 61000-4-18:2019/COR1:2019
(Corrigendum)Corrigendum 1 - Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test
Corrigendum 1 - Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test
Corrigendum 1 - Compatibilité électromagnétique (CEM) - Partie 4-18: Techniques d'essai et de mesure - Essai d'immunité à l'onde oscillatoire amortie
General Information
Relations
Standards Content (Sample)
IEC 2019
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 61000-4-18 IEC 61000-4-18
Edition 2.0 2019-05 Édition 2.0 2019-05
ELECTROMAGNETIC COMPATIBILITY (EMC) – COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (CEM) –
Part 4-18: Testing and measurement techniques Partie 4-18: Techniques d'essai et de mesure –
– Damped oscillatory wave Essai d'immunité à l'onde
immunity test oscillatoire amortie
CO RRI G E NDUM 1
B.4.5 Rise time of the step response and B.4.5 Temps de montée d
...
This May Also Interest You
IEC 61000-4-6: 2023 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz.
NOTE 1 Product committees might decide to use the methods described in this document also for frequencies up to 230 MHz (see Annex B) although the methods and test instrumentation are intended to be used in the frequency range up to 80 MHz.
Equipment not having at least one conducting wire or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this document.
NOTE 2 Test methods are specified in this part of IEC 61000 to assess the effect that conducted disturbing signals, induced by electromagnetic radiation, have on the equipment concerned. The simulation and measurement of these conducted disturbances are not adequately exact for the quantitative determination of effects. The test methods specified are structured for the primary objective of establishing adequate repeatability of results at various facilities for quantitative analysis of effects.
The object of this document is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method in this document describes a consistent method to assess the immunity of an equipment or system against a specified phenomenon.
NOTE 3 As described in IEC Guide 107, this document is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria.
This fifth edition cancels and replaces the fourth edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) selection of injection devices revised;
b) need of AE impedance check for clamp injection removed and Annex H deleted;
c) saturation check revised;
d) new Annex H on testing with multiple signals;
e) level-setting only with feedback loop.
- Standard83 pagesEnglish languagesale 15% off
- Standard189 pagesEnglish languagesale 15% off
- Standard184 pagesEnglish and French languagesale 15% off
IEC 61000-4-20:2022 focuses on emission and immunity test methods for electrical and electronic equipment using various types of transverse electromagnetic (TEM) waveguides. These types include open structures (for example striplines and electromagnetic pulse simulators) and closed structures (for example TEM cells). These structures can be further classified as one-port, two-port, or multi-port TEM waveguides. The frequency range depends on the specific testing requirements and the specific TEM waveguide type. The object of this document is to describe
TEM waveguide characteristics, including typical frequency ranges and equipment-under-test (EUT) size limitations;
TEM waveguide validation methods for electromagnetic compatibility (EMC) tests;
the EUT (i.e. EUT cabinet and cabling) definition;
test set-ups, procedures, and requirements for radiated emission measurements in TEM waveguides; and
test set-ups, procedures, and requirements for radiated immunity testing in TEM waveguides. NOTE Test methods are defined in this document to measure the effects of electromagnetic radiation on equipment and the electromagnetic emissions from the equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for the quantitative determination of effects for all end-use installations. The test methods defined are structured for a primary objective of establishing adequate reproducibility of results at various test facilities for qualitative analysis of effects.
This document does not intend to specify the tests to be applied to any particular apparatus or system(s). The main intention of this document is to provide a general basic reference for all interested product committees of the IEC. For radiated emission measurements, product committees select emission limits and measurement methods in consultation with CISPR standards. For radiated immunity testing, product committees remain responsible for the appropriate choice of immunity tests and immunity test limits to be applied to equipment within their scope. This document describes test methods that are separate from those of IEC 61000‑4‑3.
This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
provide information on the testing of large EUTs (including cables);
apply the work on measurement uncertainties by adapting the work completed in CISPR and TC 77 (for emissions and immunity);
update the validation procedure for the test volume regarding field uniformity and TEM mode verification;
provide information concerning two-port and four-port TEM waveguides;
add a new informative annex (Annex I) dealing with transient TEM waveguide characterization; and
add information dealing with dielectric test stands for EUTs.
- Standard229 pagesEnglish and French languagesale 15% off
IEC 61000-4-3:2020 is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against RF electromagnetic fields from RF sources not in close proximity to the EUT. The test environment is specified in Clause 6. NOTE 1 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. NOTE 2 Immunity testing against RF sources in close proximity to the EUT is defined in IEC 61000-4-39. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. NOTE 3 Test methods are defined in this part for evaluating the effect that electromagnetic radiation has on the equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for quantitative determination of effects. The test methods defined in this basic document have the primary objective of establishing an adequate reproducibility of testing configuration and repeatability of test results at various test facilities. This document is an independent test method. It is not possible to use other test methods as substitutes for claiming compliance with this document. This fourth edition cancels and replaces the third edition published in 2006, Amendment 1:2007 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- testing using multiple test signals has been described;
- additional information on EUT and cable layout has been added;
- the upper frequency limitation has been removed to take account of new services;
- the characterization of the field as well as the checking of power amplifier linearity of the immunity chain are specified.
- Standard81 pagesEnglish languagesale 15% off
- Standard164 pagesEnglish and French languagesale 15% off
IEC 61000-4-18: 2019 focuses on the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, with regard to:
a) repetitive slow damped oscillatory waves occurring mainly in power, control and signal cables installed in high voltage and medium voltage (HV/MV) substations;
b) repetitive fast damped oscillatory waves occurring mainly in power, control and signal cables installed in gas insulated substations (GIS) and in some cases also air insulated substations (AIS) or in any installation due to high-altitude electromagnetic pulse (HEMP) phenomena.
The object of this document is to establish a common and reproducible reference for evaluating the immunity of electrical and electronic equipment when subjected to damped oscillatory waves on supply, signal, control and earth ports. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. NOTE As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard is applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. The document defines:
test voltage and current waveforms;
ranges of test levels;
test equipment;
calibration and verification procedures of test equipment;
test setups;
test procedure.
This second edition cancels and replaces the first edition published in 2006 and its Amendment 1:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) addition of a mathematical modelling of damped oscillatory wave waveform;
b) new Annex B on measurement uncertainty;
c) addition high speed CDN;
d) addition of calibration procedures for CDNs;
e) addition of the use of the capacitive coupling clamp on interconnection lines for fast damped oscillatory waves;
f) addition of a test procedure for DC/DC converters in case the CDN does not work;
g) new Annex C on issues relating to powering EUTs having DC/DC converters at the input.
Keywords: immunity requirements and test methods for electrical and electronic equipment
The contents of the corrigendum of August 2019 have been included in this copy.
- Standard115 pagesEnglish and French languagesale 15% off
IEC 61000-4-5:2014 relates to the immunity requirements, test methods, and range of recommended test levels for equipment with regard to unidirectional surges caused by over-voltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to surges. The test method documented describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This standard defines a range of:
- test levels;
- test equipment;
- test setups; and
- test procedures. The task of the described laboratory test is to find the reaction of the equipment under test (EUT) under specified operational conditions to surge voltages caused by switching and lightning effects. It is not intended to test the capability of the EUT's insulation to withstand high-voltage stress. Direct injections of lightning currents, i.e. direct lightning strikes, are not considered in this standard. This third edition cancels and replaces the second edition published in 2005, and constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- a new Annex E on mathematical modelling of surge waveforms;
- a new Annex F on measurement uncertainty;
- a new Annex G on method of calibration of impulse measuring systems; and
- a new Annex H on coupling/decoupling surges to lines rated above 200 A. Moreover while surge test for ports connected to outside telecommunication lines was addressed in 6.2 of the second edition (IEC 61000-4-5:2005), in this third edition (IEC 61000-4-5:2014) the normative Annex A is fully dedicated to this topic. In particular it gives the specifications of the 10/700 µs combined wave generator. Keywords: electromagnetic compatibility, EMC, TC77, SC77B
- Standard155 pagesEnglish and French languagesale 15% off
- Standard334 pagesEnglish and French languagesale 15% off
Applies to electronic direct a.c. converter systems with electrical energy storage means in the d.c. link. Ensures continuity of an alternating power source. Also includes the method of specifying all power switches that form integral parts of a UPS and are associated with its output. Included are interrupters, bypass switches, isolating switches, load transfer switches and tie switches. does not refer to cnventional mains distirbution boards, rectifier input switches or d.c. switches or UPS based on rotating machines. Defines a complete uninterruptible power system in terms of its performance and not individual UPS functional units.[
]The contents of the corrigendum of July 2003 have been included in this copy.
- Standard10 pagesEnglish and French languagesale 15% off
IEC 61000-4-12:2017 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to ring waves occurring in low-voltage power, control and signal lines supplied by public and non-public networks.
The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to ring waves. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon.
It has the status of a basic EMC publication in accordance with IEC Guide 107.
This edition includes the following significant technical changes with respect to the previous edition:
a) addition of a mathematical modelling of ring wave waveform;
b) new Annex B on selection of generators and test levels;
c) new Annex C on explanatory notes;
d) new Annex D on measurement uncertainty;
e) addition of high speed CDN;
f) addition of a calibration procedure for CDN.
- Standard158 pagesEnglish languagesale 15% off
- Standard95 pagesEnglish and French languagesale 15% off
IEC 61000-4-39:2017 specifies immunity requirements for electrical and electronic equipment when it is exposed to radiated electromagnetic energy from RF transmitters used in close proximity. It establishes test levels and the required test procedures. The applicable frequency range is 9 kHz to 6 GHz. It has the status of a basic EMC publication in accordance with IEC Guide 107.
- Standard82 pagesEnglish and French languagesale 15% off
IEC 61000-4-31:2016 relates to the conducted immunity of electrical and electronic equipment to electromagnetic disturbances coming from intended and/or unintended broadband signal sources in the frequency range 150 kHz up to 80 MHz. It has the status of a basic EMC publication in accordance with IEC Guide 107.
- Standard86 pagesEnglish and French languagesale 15% off
IEC 61000-4-9:2016 specifies the immunity requirements, test methods, and range of recommended test levels for equipment subjected to impulse magnetic disturbances mainly encountered in industrial installations, power plants, railway installations, and medium voltage and high voltage sub-stations. This second edition cancels and replaces the first edition published in 1993 and Amendment 1:2000. This edition constitutes a technical revision.
- Standard181 pagesEnglish languagesale 15% off
- Standard109 pagesEnglish and French languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.