Amendment 1 - Classification of environmental conditions - Part 4-4: Guidance for the correlation and transformation of the environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Stationary use at non-weatherprotected locations

Amendement 1 - Classification des conditions d'environnement - Partie 4-4: Guide pour la corrélation et la transformation des classes de conditions d'environnement de la CEI 60721-3 en essais d'environnement de la CEI 60068 - Utilisation à poste fixe, non protégé contre les intempéries

General Information

Status
Withdrawn
Publication Date
20-May-2003
Withdrawal Date
15-Jun-2023
Current Stage
WPUB - Publication withdrawn
Completion Date
16-Jun-2023
Ref Project

Relations

Buy Standard

Technical report
IEC TR 60721-4-4:2001/AMD1:2003 - Amendment 1 - Classification of environmental conditions - Part 4-4: Guidance for the correlation and transformation of the environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Stationary use at non-weatherprotected locations
English and French language
59 pages
sale 15% off
Preview
sale 15% off
Preview
Technical report
IEC TR 60721-4-4:2001/AMD1:2003 - Amendment 1 - Classification of environmental conditions - Part 4-4: Guidance for the correlation and transformation of the environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Stationary use at non-weatherprotected locations Released:5/21/2003 Isbn:2831869684
English and French language
59 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


RAPPORT CEI
TECHNIQUE
IEC
TR 60721-4-4
TECHNICAL
REPORT
AMENDEMENT 1
AMENDMENT 1
2003-05
PUBLICATION FONDAMENTALE DE SÉCURITÉ
BASIC SAFETY PUBLICATION
Amendement 1
Classification des conditions d’environnement –
Partie 4-4:
Guide pour la corrélation et la transformation
des classes de conditions d’environnement
de la CEI 60721-3 en essais d’environnement
de la CEI 60068 –
Utilisation à poste fixe, non protégé contre
les intempéries
Amendment 1
Classification of environmental conditions –
Part 4-4:
Guidance for the correlation and transformation
of environmental condition classes of IEC 60721-3
to the environmental tests of IEC 60068 –
Stationary use at non-weatherprotected locations
CODE PRIX
U
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
Pour prix, voir catalogue en vigueur

– 2 – TR 60721-4-4 Amend. 1  CEI:2003
AVANT-PROPOS
Le présent amendement a été établi par le comité d'études 104 de la CEI: Conditions,
classification et essais d'environnement.
Le texte de cet amendement est issu des documents suivants:
Projet d’enquête Rapport de vote
104/197/DTR 104/258A/RVC
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant 2006. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
_____________
Page 2
Ajouter le titre des nouvelles annexes suivantes:
Annexe A Utilisation à poste fixe non protégé contre les intempéries – Conditions climatiques
Annexe B Utilisation à poste fixe non protégé contre les intempéries – Conditions dynamiques
Remplacer la liste des tableaux existante par la nouvelle liste suivante:
Tableau 1 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K2
Tableau 2 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K3
Tableau 3 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K4
Tableau 4 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M1
Tableau 5 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M2
Tableau 6 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M3
Tableau 7 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M4
Tableau 8 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M6
Tableau A.1 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K1
Tableau A.2 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K4H
Tableau A.3 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K4L
Tableau A.4 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K5
Tableau A.5 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K6
Tableau B.1 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M5
Tableau B.2 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M7
Tableau B.3 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M8

– 3 – TR 60721-4-4 Amend. 1  IEC:2003
FOREWORD
This amendment has been prepared by IEC technical committee 104: Environmental
conditions, classification and methods of test.
The text of this amendment is based on the following documents:
Enquiry draft Report on voting
104/197/DTR 104/258A/RVC
Full information on the voting for the approval of this amendment can be found in the
report on voting indicated in the above table.
The committee has decided that the contents of the base publication and its amendments
will remain unchanged until 2006. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
_____________
Page 3
CONTENTS
Add the title of the following new annexes:
Annex A Stationary use at non-weatherprotected locations – Climatic conditions
Annex B Stationary use at non-weatherprotected locations – Dynamic conditions
Replace the existing list of tables by the following new list:
Table 1 – Recommended tests for IEC 60721-3-4 – Class 4K2
Table 2 – Recommended tests for IEC 60721-3-4 – Class 4K3
Table 3 – Recommended tests for IEC 60721-3-4 – Class 4K4
Table 4 – Recommended tests for IEC 60721-3-4 – Class 4M1
Table 5 – Recommended tests for IEC 60721-3-4 – Class 4M2
Table 6 – Recommended tests for IEC 60721-3-4 – Class 4M3
Table 7 – Recommended tests for IEC 60721-3-4 – Class 4M4
Table 8 – Recommended tests for IEC 60721-3-4 – Class 4M6
Table A.1 – Recommended tests for IEC 60721-3-4 – Class 4K1
Table A.2 – Recommended tests for IEC 60721-3-4 – Class 4K4H
Table A.3 – Recommended tests for IEC 60721-3-3 – Class 4K4L
Table A.4 – Recommended tests for IEC 60721-3-4 – Class 4K5
Table A.5 – Recommended tests for IEC 60721-3-4 – Class 4K6
Table B.1 – Recommended tests for IEC 60721-3-4 – Class 4M5
Table B.2 – Recommended tests for IEC 60721-3-4 – Class 4M7
Table B.3 – Recommended tests for IEC 60721-3-4 – Class 4M8

– 4 – TR 60721-4-4 Amend. 1  CEI:2003
Cette page est volontairement laissée vierge.

– 5 – TR 60721-4-4 Amend. 1  IEC:2003
This page is intentionally blank.

– 6 – TR 60721-4-4 Amend. 1  CEI:2003
Page 48
Ajouter, après le Tableau 8, les nouvellse Annexes A et B suivantes:

– 7 – TR 60721-4-4 Amend. 1  IEC:2003
Page 49
Add, after Table 8, the following new Annex A and Annex B:

– 8 –        TR 60721-4-4 Amend. 1  CEI:2003
Annexe A
Utilisation à poste fixe non protégé contre les intempéries – Conditions climatiques
Tableau A.1 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K1
(emplacements non protégés contre les intempéries: groupe restreint de climats à l'air libre – chaud tempéré uniquement)
CEI 60721-3-4 – Conditions climatiques CEI 60068-2 – Essais climatiques
Essai de la CEI 60068-2 le plus approchant Essai recommandé Notes
Catégorie
Agent d'environnement
4K1
Méthode d'essai Sévérité Méthode d'essai Sévérité n°
x) Chaleur sèche +40 °C, 16 h x) Chaleur sèche +35 °C, 16 h
1), 2)
Chaleur sèche
CEI 60068-2-2: CEI 60068-2-2:
Chaleur humide
Bb/Bd Bb/Bd
1), 3)
y) Froid –25 °C, 16 h y) Froid –20 °C, 16 h
CEI 60068-2-1: CEI 60068-2-1:
Température Ab/Ad Ab/Ad 1), 4)
Humidité
°C
z) Chaleur humide Selon l'essai recommandé z) Chaleur humide +30 °C, 93 % HR, 96 h
absolue
CEI 60068-2-56:
g/m
Cb
-10
-20
0,9
Froid
0 20 40 60 80
Humidité relative  % HR
Figure A.1 – Catégorie 4K1 – Climatogramme
a) Basse température de l’air –20 °C Voir ci-dessus Voir ci-dessus
b) Haute température de l’air +35 °C Voir ci-dessus Voir ci-dessus
c) Faible humidité relative 20 % Selon l'essai recommandé Voir ci-dessus
d) Forte humidité relative 100 % Selon l'essai recommandé Voir ci-dessus
e) Faible humidité absolue 0,9 g/m Selon l'essai recommandé Voir ci-dessus
f) Forte humidité absolue 22 g/m Selon l'essai recommandé Voir ci-dessus
g) Intensité de la pluie 6 mm/min 60068-2-18:Ra Intensité: 400 mm/h CEI 60068-2-18; Rb Exposition: 1min/m 5)
méthode 1 durée: 10 min minimum méthode 2.2 Durée: 5 min minimum
h) Taux de variation de la température 0,5 °C/min CEI 60068-2-14: –25 °C jusqu'à température CEI 60068-2-14: –20 °C jusqu'à température 6)
Nb ambiante, deux cycles Nb ambiante, deux cycles
1 °C/min t =3 h 0,5 °C/min t = 3 h
1 1
i) Basse pression atmosphérique 70 kPa CEI 60068-2-13: M 70 kPa, 30 min Essai normalement non requis – voir note 7) 7)
j) Haute pression atmosphérique 106 kPa Pas d’essai de la CEI 60068-2 Essai normalement non requis – voir note 8) 8)
k) Rayonnement solaire 1 120 W/m² CEI 60068-2-5: Sa 1 120 W/m², 72 h, 40 °C Ajouter 15 °C à l’essai de chaleur sèche et 9)
Procédure C évaluer les matériaux par rapport aux réactions
photochimiques
l) Rayonnement de chaleur Pas d’essai de la CEI 60068-2 Essai normalement non requis – voir note 10) 10)
Choix de l'utilisateur entre 4Z1 ou 4Z2
suite
TR 60721-4-4 Amend. 1  CEI.2003         – 9 –
Notes explicatives pour le Tableau A.1 – Catégorie 4K1
1) Pour essayer des matériels par rapport aux conditions du climatogramme, vitesse de variation est de 0,5 °C/min, cependant la valeur préférentielle la
seuls trois essais sont normalement utilisés; plus basse dans l’essai N de la CEI 60068-2-14 est de 1 °C/min. Il est
recommandé que la valeur d’essai de 0,5 °C soit utilisée, en particulier pour
– l’essai de chaleur sèche pour lequel l’humidité relative ne doit pas
les matériels de grandes dimensions dissipateurs d’énergie.
dépasser 50 % mais n’est pas particulièrement contrôlée;
7) Pour les matériels hermétiquement fermés ou pour les matériels contenant ou
– l’essai de froid pour lequel l’humidité n’est pas contrôlée;
traitant des liquides, l’essai M de la CEI 60068-2-13 est recommandé. Pour
des applications normales dans lesquelles l’effet de la pression
– l’essai continu de chaleur humide pour lequel à la fois la température et
l’humidité sont contrôlées. atmosphérique est évalué au niveau du composant, il n'est pas recommandé
d'essai.
Ces essais sont les essais x, y et z du climatogramme. Les autres
8) Il n'est pas recommandé d'essai. Il n’y a pas de méthode d’essai dans la CEI
conditions limites du climatogramme ne sont pas à essayer et il n’existe pas
60068-2 pour cette condition qui est considérée comme peu contraignante
d’essai adapté dans la CEI 60068-2.
pour la plupart des matériels.
2) La température d’essai est la valeur préférentielle la plus proche. Il est
9) La méthode d’essai C de la CEI 60068-2-5 destinée à simuler les effets du
recommandé que la valeur d'essai de +35 °C soit utilisée, conformément à
rayonnement solaire au niveau du sol a été choisie car elle produit un
l’agent d’environnement de la CEI 60721-3-4 pour cette catégorie. Le choix de
rayonnement continu permettant l’évaluation des effets de la
la durée de 16 h est considéré comme suffisant pour la plupart des
spécimens dissipateurs d’énergie pour démontrer que leur conception entre photodégradation. La sévérité de cette catégorie est de 1 120 W/m , ce qui
correspond à la condition d’essai contenue dans la CEI 60068-2-5: Sa.
correctement dans les tolérances pour fonctionner à cette température.
Les essais d’exposition solaire ne sont pas considérés comme satisfaisants
3) La température d’essai est la valeur préférentielle la plus proche de la CEI
car il est difficile de reproduire le rayonnement réel constaté dans la
60068-2. Il est recommandé que la valeur d'essai de −20 °C soit utilisée,
pratique. Il est recommandé que cette condition soit évaluée en augmentant
conformément à l'agent d'environnement de la CEI 60721-3-4 pour cette
la température de l’essai de chaleur sèche de 15 °C, et en évaluant les
catégorie, cependant il convient de prendre également en compte les effets
matériaux et les composants par rapport aux réactions photochimiques. Pour
du rayonnement calorifique (voir note 9). Le choix de 16 h pour la durée est
plus d’informations, voir la CEI 60741-4-0.
considéré comme suffisant pour la plupart des spécimens dissipateurs
d’énergie pour démontrer que leur conception entre correctement dans les
Avec ce niveau de rayonnement solaire, les températures de surface
tolérances pour fonctionner à cette température.
peuvent être supérieures de 25 °C par rapport à la température ambiante. La
température de surface peut également chuter pendant la nuit en raison du
4) Ces sévérités sont les valeurs préférentielles les plus proches de la CEI
rayonnement calorifique (voir la CEI 60721-2-4). Il convient de prendre ces
60068-2 et les légères différences, à la fois de température et d’humidité,
effets en compte quand on choisit les matériaux et il convient de tenir
sont considérées comme insignifiantes et comprises dans les tolérances
compte d’un essai réduit de température pour l’essai à basse température
normales de mesure. La durée de 96 h est considérée comme suffisante pour
(essai Ab/Ad).
la plupart des spécimens dissipateurs d’énergie afin de démontrer que la
conception du matériel entre correctement dans les tolérances pour supporter
Les matériels peuvent être protégés contre les effets du rayonnement
cette humidité.
solaire, par exemple en adaptant des écrans thermiques efficaces, auquel
cas l’essai à température élevée de chaleur sèche peut être omis ou réduit
5) La CEI 60068-2-18 recommande l’essai Ra 1 pour les matériels exposés à la
en sévérité selon l’efficacité des précautions prises. Il serait de bonne
pluie. Cependant cet essai ne correspond pas à l’intensité de pluie de cette
pratique de modéliser de telles précautions pour donner confiance en
catégorie de la CEI 60721 et cette intensité n’est pas réalisable pour des
l’aptitude du matériel à résister aux effets du rayonnement solaire.
articles de grandes dimensions. L’essai Rb 2.2 est par conséquent
recommandé car c’est un essai simple, reproductible, qui peut être réalisé sur
10) Il n’existe pas de valeur dans la CEI 60721-3-4 pour le rayonnement
des matériels de toutes dimensions.
calorifique, et par conséquent il n’est pas recommandé d’essai
supplémentaire car les effets sont normalement compris dans l’essai de
6) L’essai de variation en température est normalement utilisé pour vérifier les
chaleur sèche. Pour les matériels installés à proximité de sources de forts
tolérances de la conception et que la gamme de températures n’est pas
rayonnements thermiques, des précautions particulières comme des écrans
importante. Cependant pour cette catégorie, de la condensation peut se
thermiques ou une isolation peuvent être nécessaires, ou un essai
former, c’est pourquoi une gamme dont la limite est au-delà de 0 °C, est
supplémentaire à température élevée peut être requis, le degré
proposée pour permettre la formation de la condensation sur un matériel à
d’augmentation étant fonction de la sévérité de la source de chaleur.
faible dissipation d’énergie. La valeur spécifiée dans la CEI 60721-3-4 pour la

– 10 –        TR 60721-4-4 Amend. 1  IEC:2003
Annex A
Stationary use at non-weatherprotected locations – Climatic conditions
Table A.1 – Recommended tests for IEC 60721-3-4 – Class 4K1
(non-weatherprotected locations: restricted group of open-air climates – warm temperate only)
IEC 60721-3-4 – Climatic conditions IEC 60068-2 – Climatic tests
Nearest IEC 60068-2 Recommended test Note
Class
Environmental parameter no.
4K1
Test method Severity Test method Severity
x) Dry heat +40 °C, 16 h x) Dry heat +35 °C, 16 h
1), 2)
D ry heat
40 IEC 60068-2-2: IEC 60068-2-2:
D a m p heat
Bb/Bd Bb/Bd
22 1)
...


RAPPORT CEI
TECHNIQUE
IEC
TR 60721-4-4
TECHNICAL
REPORT
AMENDEMENT 1
AMENDMENT 1
2003-05
PUBLICATION FONDAMENTALE DE SÉCURITÉ
BASIC SAFETY PUBLICATION
Amendement 1
Classification des conditions d’environnement –
Partie 4-4:
Guide pour la corrélation et la transformation
des classes de conditions d’environnement
de la CEI 60721-3 en essais d’environnement
de la CEI 60068 –
Utilisation à poste fixe, non protégé contre
les intempéries
Amendment 1
Classification of environmental conditions –
Part 4-4:
Guidance for the correlation and transformation
of environmental condition classes of IEC 60721-3

to the environmental tests of IEC 60068 –
Stationary use at non-weatherprotected locations
CODE PRIX
U
Commission Electrotechnique Internationale
PRICE CODE
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
Pour prix, voir catalogue en vigueur

– 2 – TR 60721-4-4 Amend. 1  CEI:2003

AVANT-PROPOS
Le présent amendement a été établi par le comité d'études 104 de la CEI: Conditions,
classification et essais d'environnement.

Le texte de cet amendement est issu des documents suivants:

Projet d’enquête Rapport de vote

104/197/DTR 104/258A/RVC
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant 2006. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
_____________
Page 2
Ajouter le titre des nouvelles annexes suivantes:
Annexe A Utilisation à poste fixe non protégé contre les intempéries – Conditions climatiques
Annexe B Utilisation à poste fixe non protégé contre les intempéries – Conditions dynamiques
Remplacer la liste des tableaux existante par la nouvelle liste suivante:
Tableau 1 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K2
Tableau 2 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K3
Tableau 3 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K4
Tableau 4 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M1
Tableau 5 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M2

Tableau 6 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M3
Tableau 7 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M4
Tableau 8 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M6
Tableau A.1 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K1
Tableau A.2 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K4H
Tableau A.3 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K4L
Tableau A.4 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K5
Tableau A.5 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K6
Tableau B.1 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M5
Tableau B.2 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M7
Tableau B.3 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4M8

– 3 – TR 60721-4-4 Amend. 1  IEC:2003

FOREWORD
This amendment has been prepared by IEC technical committee 104: Environmental
conditions, classification and methods of test.

The text of this amendment is based on the following documents:

Enquiry draft Report on voting

104/197/DTR 104/258A/RVC
Full information on the voting for the approval of this amendment can be found in the
report on voting indicated in the above table.
The committee has decided that the contents of the base publication and its amendments
will remain unchanged until 2006. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
_____________
Page 3
CONTENTS
Add the title of the following new annexes:
Annex A Stationary use at non-weatherprotected locations – Climatic conditions
Annex B Stationary use at non-weatherprotected locations – Dynamic conditions
Replace the existing list of tables by the following new list:
Table 1 – Recommended tests for IEC 60721-3-4 – Class 4K2
Table 2 – Recommended tests for IEC 60721-3-4 – Class 4K3
Table 3 – Recommended tests for IEC 60721-3-4 – Class 4K4
Table 4 – Recommended tests for IEC 60721-3-4 – Class 4M1
Table 5 – Recommended tests for IEC 60721-3-4 – Class 4M2

Table 6 – Recommended tests for IEC 60721-3-4 – Class 4M3
Table 7 – Recommended tests for IEC 60721-3-4 – Class 4M4
Table 8 – Recommended tests for IEC 60721-3-4 – Class 4M6
Table A.1 – Recommended tests for IEC 60721-3-4 – Class 4K1
Table A.2 – Recommended tests for IEC 60721-3-4 – Class 4K4H
Table A.3 – Recommended tests for IEC 60721-3-3 – Class 4K4L
Table A.4 – Recommended tests for IEC 60721-3-4 – Class 4K5
Table A.5 – Recommended tests for IEC 60721-3-4 – Class 4K6
Table B.1 – Recommended tests for IEC 60721-3-4 – Class 4M5
Table B.2 – Recommended tests for IEC 60721-3-4 – Class 4M7
Table B.3 – Recommended tests for IEC 60721-3-4 – Class 4M8

– 4 – TR 60721-4-4 Amend. 1  CEI:2003

Cette page est volontairement laissée vierge.

– 5 – TR 60721-4-4 Amend. 1  IEC:2003

This page is intentionally blank.

– 6 – TR 60721-4-4 Amend. 1  CEI:2003

Page 48
Ajouter, après le Tableau 8, les nouvellse Annexes A et B suivantes:

– 7 – TR 60721-4-4 Amend. 1  IEC:2003

Page 49
Add, after Table 8, the following new Annex A and Annex B:

– 8 –        TR 60721-4-4 Amend. 1  CEI:2003

Annexe A
Utilisation à poste fixe non protégé contre les intempéries – Conditions climatiques
Tableau A.1 – Essais recommandés pour la CEI 60721-3-4 – Catégorie 4K1
(emplacements non protégés contre les intempéries: groupe restreint de climats à l'air libre – chaud tempéré uniquement)
CEI 60721-3-4 – Conditions climatiques CEI 60068-2 – Essais climatiques
Essai de la CEI 60068-2 le plus approchant Essai recommandé Notes
Catégorie
Agent d'environnement
4K1
Méthode d'essai Sévérité Méthode d'essai Sévérité n°
x) Chaleur sèche +40 °C, 16 h x) Chaleur sèche +35 °C, 16 h
1), 2)
Chaleur sèche
CEI 60068-2-2: CEI 60068-2-2:
Chaleur humide
Bb/Bd Bb/Bd
1), 3)
y) Froid –25 °C, 16 h y) Froid –20 °C, 16 h
CEI 60068-2-1: CEI 60068-2-1:
Température Ab/Ad Ab/Ad 1), 4)
Humidité
°C
z) Chaleur humide Selon l'essai recommandé z) Chaleur humide +30 °C, 93 % HR, 96 h
absolue
CEI 60068-2-56:
g/m
Cb
-10
-20
0,9
Froid
0 20 40 60 80
Humidité relative  % HR
Figure A.1 – Catégorie 4K1 – Climatogramme
a) Basse température de l’air –20 °C Voir ci-dessus Voir ci-dessus
b) Haute température de l’air +35 °C Voir ci-dessus Voir ci-dessus
c) Faible humidité relative 20 % Selon l'essai recommandé Voir ci-dessus
d) Forte humidité relative 100 % Selon l'essai recommandé Voir ci-dessus
e) Faible humidité absolue 0,9 g/m Selon l'essai recommandé Voir ci-dessus
f) Forte humidité absolue 22 g/m Selon l'essai recommandé Voir ci-dessus
g) Intensité de la pluie 6 mm/min 60068-2-18:Ra Intensité: 400 mm/h CEI 60068-2-18; Rb Exposition: 1min/m 5)
méthode 1 durée: 10 min minimum méthode 2.2 Durée: 5 min minimum
h) Taux de variation de la température 0,5 °C/min CEI 60068-2-14: –25 °C jusqu'à température CEI 60068-2-14: –20 °C jusqu'à température 6)
Nb ambiante, deux cycles Nb ambiante, deux cycles
1 °C/min t =3 h 0,5 °C/min t = 3 h
1 1
i) Basse pression atmosphérique 70 kPa CEI 60068-2-13: M 70 kPa, 30 min Essai normalement non requis – voir note 7) 7)
j) Haute pression atmosphérique 106 kPa Pas d’essai de la CEI 60068-2 Essai normalement non requis – voir note 8) 8)
k) Rayonnement solaire 1 120 W/m² CEI 60068-2-5: Sa 1 120 W/m², 72 h, 40 °C Ajouter 15 °C à l’essai de chaleur sèche et 9)
Procédure C évaluer les matériaux par rapport aux réactions
photochimiques
l) Rayonnement de chaleur Pas d’essai de la CEI 60068-2 Essai normalement non requis – voir note 10) 10)
Choix de l'utilisateur entre 4Z1 ou 4Z2
suite
TR 60721-4-4 Amend. 1  CEI.2003         – 9 –

Notes explicatives pour le Tableau A.1 – Catégorie 4K1
1) Pour essayer des matériels par rapport aux conditions du climatogramme, vitesse de variation est de 0,5 °C/min, cependant la valeur préférentielle la
seuls trois essais sont normalement utilisés; plus basse dans l’essai N de la CEI 60068-2-14 est de 1 °C/min. Il est
recommandé que la valeur d’essai de 0,5 °C soit utilisée, en particulier pour
– l’essai de chaleur sèche pour lequel l’humidité relative ne doit pas
les matériels de grandes dimensions dissipateurs d’énergie.
dépasser 50 % mais n’est pas particulièrement contrôlée;
7) Pour les matériels hermétiquement fermés ou pour les matériels contenant ou
– l’essai de froid pour lequel l’humidité n’est pas contrôlée;
traitant des liquides, l’essai M de la CEI 60068-2-13 est recommandé. Pour
des applications normales dans lesquelles l’effet de la pression
– l’essai continu de chaleur humide pour lequel à la fois la température et
l’humidité sont contrôlées. atmosphérique est évalué au niveau du composant, il n'est pas recommandé
d'essai.
Ces essais sont les essais x, y et z du climatogramme. Les autres
8) Il n'est pas recommandé d'essai. Il n’y a pas de méthode d’essai dans la CEI
conditions limites du climatogramme ne sont pas à essayer et il n’existe pas
60068-2 pour cette condition qui est considérée comme peu contraignante
d’essai adapté dans la CEI 60068-2.
pour la plupart des matériels.
2) La température d’essai est la valeur préférentielle la plus proche. Il est
9) La méthode d’essai C de la CEI 60068-2-5 destinée à simuler les effets du
recommandé que la valeur d'essai de +35 °C soit utilisée, conformément à
rayonnement solaire au niveau du sol a été choisie car elle produit un
l’agent d’environnement de la CEI 60721-3-4 pour cette catégorie. Le choix de
rayonnement continu permettant l’évaluation des effets de la
la durée de 16 h est considéré comme suffisant pour la plupart des
spécimens dissipateurs d’énergie pour démontrer que leur conception entre photodégradation. La sévérité de cette catégorie est de 1 120 W/m , ce qui
correspond à la condition d’essai contenue dans la CEI 60068-2-5: Sa.
correctement dans les tolérances pour fonctionner à cette température.
Les essais d’exposition solaire ne sont pas considérés comme satisfaisants
3) La température d’essai est la valeur préférentielle la plus proche de la CEI
car il est difficile de reproduire le rayonnement réel constaté dans la
60068-2. Il est recommandé que la valeur d'essai de −20 °C soit utilisée,
pratique. Il est recommandé que cette condition soit évaluée en augmentant
conformément à l'agent d'environnement de la CEI 60721-3-4 pour cette
la température de l’essai de chaleur sèche de 15 °C, et en évaluant les
catégorie, cependant il convient de prendre également en compte les effets
matériaux et les composants par rapport aux réactions photochimiques. Pour
du rayonnement calorifique (voir note 9). Le choix de 16 h pour la durée est
plus d’informations, voir la CEI 60741-4-0.
considéré comme suffisant pour la plupart des spécimens dissipateurs
d’énergie pour démontrer que leur conception entre correctement dans les
Avec ce niveau de rayonnement solaire, les températures de surface
tolérances pour fonctionner à cette température.
peuvent être supérieures de 25 °C par rapport à la température ambiante. La
température de surface peut également chuter pendant la nuit en raison du
4) Ces sévérités sont les valeurs préférentielles les plus proches de la CEI
rayonnement calorifique (voir la CEI 60721-2-4). Il convient de prendre ces
60068-2 et les légères différences, à la fois de température et d’humidité,
effets en compte quand on choisit les matériaux et il convient de tenir
sont considérées comme insignifiantes et comprises dans les tolérances
compte d’un essai réduit de température pour l’essai à basse température
normales de mesure. La durée de 96 h est considérée comme suffisante pour
(essai Ab/Ad).
la plupart des spécimens dissipateurs d’énergie afin de démontrer que la
conception du matériel entre correctement dans les tolérances pour supporter
Les matériels peuvent être protégés contre les effets du rayonnement
cette humidité.
solaire, par exemple en adaptant des écrans thermiques efficaces, auquel
cas l’essai à température élevée de chaleur sèche peut être omis ou réduit
5) La CEI 60068-2-18 recommande l’essai Ra 1 pour les matériels exposés à la
en sévérité selon l’efficacité des précautions prises. Il serait de bonne
pluie. Cependant cet essai ne correspond pas à l’intensité de pluie de cette
pratique de modéliser de telles précautions pour donner confiance en
catégorie de la CEI 60721 et cette intensité n’est pas réalisable pour des
l’aptitude du matériel à résister aux effets du rayonnement solaire.
articles de grandes dimensions. L’essai Rb 2.2 est par conséquent
recommandé car c’est un essai simple, reproductible, qui peut être réalisé sur
10) Il n’existe pas de valeur dans la CEI 60721-3-4 pour le rayonnement
des matériels de toutes dimensions.
calorifique, et par conséquent il n’est pas recommandé d’essai
supplémentaire car les effets sont normalement compris dans l’essai de
6) L’essai de variation en température est normalement utilisé pour vérifier les
chaleur sèche. Pour les matériels installés à proximité de sources de forts
tolérances de la conception et que la gamme de températures n’est pas
rayonnements thermiques, des précautions particulières comme des écrans
importante. Cependant pour cette catégorie, de la condensation peut se
thermiques ou une isolation peuvent être nécessaires, ou un essai
former, c’est pourquoi une gamme dont la limite est au-delà de 0 °C, est
supplémentaire à température élevée peut être requis, le degré
proposée pour permettre la formation de la condensation sur un matériel à
d’augmentation étant fonction de la sévérité de la source de chaleur.
faible dissipation d’énergie. La valeur spécifiée dans la CEI 60721-3-4 pour la

– 10 –        TR 60721-4-4 Amend. 1  IEC:2003

Annex A
Stationary use at non-weatherprotected locations – Climatic conditions
Table A.1 – Recommended tests for IEC 60721-3-4 – Class 4K1
(non-weatherprotected locations: restricted group of open-air climates – warm temperate only)
IEC 60721-3-4 – Climatic conditions IEC 60068-2 – Climatic tests
Nearest IEC 60068-2 Recommended test Note
Class
...

Questions, Comments and Discussion