IEC 60730-2-3:2006
(Main)Automatic electrical controls for household and similar use - Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps
Automatic electrical controls for household and similar use - Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps
This part of IEC 60730 applies to the evaluation of thermal protectors for ballasts for tubular fluorescent lamps. This standard applies to thermal protectors using NTC or PTC thermistors, additional requirements for which are contained in Annex J. Requirements concerning the testing of the combination of ballasts and thermal protectors are given in IEC 61347-1.
Dispositifs de commande électrique automatiques à usage domestique et analogue - Partie 2-3: Règles particulières pour les protecteurs thermiques des ballasts pour lampes tubulaires à fluorescence
La présente partie de la CEI 60730 s'applique à l'évaluation des protecteurs thermiques des ballasts pour lampes tubulaires à fluorescence. La présente norme s'applique aux protecteurs thermiques utilisant des thermistances CTN ou CTP, dont les exigences complémentaires sont contenues à l'Annexe J. Les exigences concernant les essais de la combinaison de ballasts et de protecteurs thermiques sont données dans la CEI 61347-1.
General Information
Relations
Standards Content (Sample)
NORME CEI
INTERNATIONALE
IEC
60730-2-3
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
2006-10
Dispositifs de commande électrique
automatiques à usage domestique et analogue –
Partie 2-3:
Règles particulières pour les protecteurs
thermiques des ballasts pour lampes
tubulaires à fluorescence
Automatic electrical controls
for household and similar use –
Part 2-3:
Particular requirements for thermal protectors
for ballasts for tubular fluorescent lamps
Numéro de référence
Reference number
CEI/IEC 60730-2-3:2006
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE
IEC
60730-2-3
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
2006-10
Dispositifs de commande électrique
automatiques à usage domestique et analogue –
Partie 2-3:
Règles particulières pour les protecteurs
thermiques des ballasts pour lampes
tubulaires à fluorescence
Automatic electrical controls
for household and similar use –
Part 2-3:
Particular requirements for thermal protectors
for ballasts for tubular fluorescent lamps
© IEC 2006 Droits de reproduction réservés ⎯ Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
N
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 60730-2-3 © CEI:2006
SOMMAIRE
AVANT PROPOS .4
1 Domaine d'application et références normatives.10
2 Définitions .12
3 Exigences générales.12
4 Généralités sur les essais.12
5 Caractéristiques nominales .12
6 Classification .12
7 Informations .14
8 Protection contre les chocs électriques .16
9 Dispositions en vue de la mise à la terre de protection .16
10 Bornes et connexions .18
11 Exigences de construction .18
12 Résistance à l'humidité et à la poussière.18
13 Résistance d'isolement et rigidité diélectrique .18
14 Echauffements.18
15 Tolérances de fabrication et dérive .18
16 Contraintes climatiques.20
17 Surcharge, endurance et court-circuit limité .20
18 Résistance mécanique.24
19 Pièces filetées et connexions .24
20 Lignes de fuite, distances dans l'air et distances à travers l'isolation.24
21 Résistance à la chaleur, au feu et aux courants de cheminement .26
22 Résistance à la corrosion.26
23 Exigences de compatibilité électromagnétique (CEM) – émission .26
24 Eléments constituants.26
25 Fonctionnement normal .26
26 Exigences de compatibilité électromagnétique (CEM) – immunité.26
27 Fonctionnement anormal.26
28 Guide sur l'utilisation des coupures électroniques .26
Annexes.28
Annexe C (normative) Coton utilisé pour l'essai des interrupteurs au mercure (ne
s’applique pas dans les pays membres du CENELEC).28
Annexe E (normative) Circuit de mesure des courants de fuite .28
60730-2-3 © IEC:2006 – 3 –
CONTENTS
FOREWORD.5
1 Scope and normative references.11
2 Definitions .13
3 General requirements .13
4 General notes on tests.13
5 Rating.13
6 Classification .13
7 Information .15
8 Protection against electric shock.17
9 Provision for protective earthing.17
10 Terminals and terminations.19
11 Constructional requirements .19
12 Moisture and dust resistance .19
13 Electric strength and insulation resistance.19
14 Heating.19
15 Manufacturing deviation and drift .19
16 Environmental stress .21
17 Overload, endurance and limited short-circuit.21
18 Mechanical strength.25
19 Threaded parts and connections .25
20 Creepage distances, clearances and distances through solid insulation.25
21 Resistance to heat, fire and tracking .27
22 Resistance to corrosion .27
23 Electromagnetic compatibility (EMC) requirements – emission .27
24 Components .27
25 Normal operation .27
26 Electromagnetic compatibility (EMC) requirements – immunity .27
27 Abnormal operation.27
28 Guidance on the use of electronic disconnection .27
Annexes.29
Annex C (normative) Cotton used for mercury switch test .29
Annex E (normative) Circuit for measuring leakage current.29
– 4 – 60730-2-3 © CEI:2006
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
DISPOSITIFS DE COMMANDE ÉLECTRIQUE AUTOMATIQUES
À USAGE DOMESTIQUE ET ANALOGUE –
Partie 2-3: Règles particulières pour les protecteurs thermiques
des ballasts pour lampes tubulaires à fluorescence
AVANT PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation composée
de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes internationales,
des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des
Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des comités d'études,
aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations
internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent également aux
travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO), selon des
conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable de
l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 60730-2-3 a été préparée par le comité d'études 72 de la CEI:
Commandes automatiques pour appareils domestiques.
Cette deuxième édition annule et remplace la première édition publiée en 1990, son
amendement 1 (1995) et son amendement 2 (2001). Cette deuxième édition constitue une
révision technique. Cette nouvelle édition actualise la norme par rapport à la CEI 60730-1,
édition 3 (1999) et son amendement 1 (2003).
60730-2-3 © IEC:2006 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
AUTOMATIC ELECTRICAL CONTROLS
FOR HOUSEHOLD AND SIMILAR USE –
Part 2-3: Particular requirements for thermal protectors
for ballasts for tubular fluorescent lamps
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60730-2-3 has been prepared by IEC technical committee 72:
Automatic controls for household use.
This second edition cancels and replaces the first edition published in 1990, Amendment 1
(1995) and Amendment 2 (2001). This second edition constitutes a technical revision. This
new edition updates the standard to IEC 60730-1, Edition 3 (1999) and its Amendment 1
(2003).
– 6 – 60730-2-3 © CEI:2006
Le texte de la présente norme est issu des documents suivants:
FDIS Rapport de vote
72/709/FDIS 72/722/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été établie en accord avec les Directives ISO/IEC, Partie 2.
La présente Partie 2-3 doit être utilisée conjointement avec la CEI 60730-1. Elle a été établie
sur la base de la troisième édition de cette norme (1999) et de son amendement 1 (2003). Les
éditions futures de la CEI 60730-1, ou ses amendements, pourront être pris en considération.
La présente Partie 2-3 complète ou modifie les articles correspondants de la CEI 60730-1 de
façon à la transformer en norme CEI: Règles particulières pour les protecteurs thermiques des
ballasts pour lampes tubulaires à fluorescence.
Lorsque cette Partie 2-3 spécifie "addition", "modification" or "remplacement", l'exigence, la
modalité d'essai ou le commentaire correspondant de la Partie 1 doivent être adaptés en
conséquence.
Lorsque aucune modification n'est nécessaire, la présente Partie 2-3 indique que l'article ou le
paragraphe approprié est applicable.
Afin d'obtenir une norme complètement internationale, il a été nécessaire d'examiner des
exigences différentes résultant de l'expérience acquise dans diverses parties du monde et de
reconnaître les différences nationales dans les réseaux d'alimentation électrique et les règles
d'installation.
Les notes "dans certains pays" relatives aux pratiques nationales différentes sont contenues dans les articles et les
paragraphes suivants:
– Tableau 7.2, point 101
– 12.2
– 17.4
– Annexe C
– Annexe D
Dans la présente norme, les caractères d'imprimerie suivants sont employés:
– Exigences proprement dites: caractères romains.
– Modalités d'essais: caractères italiques.
– Commentaires: petits caractères romains.
Les paragraphes, notes, tableaux ou figures complémentaires à ceux de la Partie 1 sont
numérotés à partir de 101, les annexes complémentaires sont dénommées AA, BB, etc.
Une liste de toutes les parties de la CEI 60730, sous le titre général: Dispositifs de commande
électrique automatiques à usage domestique et analogue, est disponible sur le site web de la
CEI.
60730-2-3 © IEC:2006 – 7 –
The text of this standard is based upon the following documents:
FDIS Report on voting
72/709/FDIS 72/722/RVD
Full information on the voting for the approval of this part can be found in the report on voting
indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
This Part 2-3 is intended to be used in conjunction with IEC 60730-1. It was established on the
basis of the third edition of that standard (1999) and its amendment 1 (2003). Consideration
may be given to future editions of, or amendments to, IEC 60730-1.
This Part 2-3 supplements or modifies the corresponding clauses in IEC 60730-1 so as to
convert that publication into the IEC standard: Particular requirements for thermal protectors
for ballasts for tubular fluorescent lamps.
Where this Part 2-3 states "addition", "modification" or "replacement", the relevant requirement,
test specification or explanatory matter in Part 1 shall be adapted accordingly.
Where no change is necessary, this Part 2-3 indicates that the relevant clause or subclause
applies.
In the development of a fully international standard, it has been necessary to take into
consideration the differing requirements resulting from practical experience in various parts of
the world and to recognize the variation in national electrical systems and wiring rules.
The ‘in some countries’ notes regarding differing national practice are contained in the following subclauses:
– Table 7.2, item 101
– 12.2
– 17.4
– Annex C
– Annex D
In this publication, the following print types are used:
– Requirements proper: in roman type.
– Test specifications: in italic type.
– Explanatory matter: in smaller roman type.
Subclauses, notes, items or figures which are additional to those in Part 1 are numbered
starting from 101, additional annexes are lettered AA, BB, etc.
A list of all parts of the IEC 60730 series, under the general title Automatic electrical controls for
household and similar use, can be found on the IEC website.
– 8 – 60730-2-3 © CEI:2006
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
maintenance indiquée sur le site web de la CEI sous «http://webstore.iec.ch» dans les données
relatives à la publication recherchée. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
60730-2-3 © IEC:2006 – 9 –
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 10 – 60730-2-3 © CEI:2006
DISPOSITIFS DE COMMANDE ÉLECTRIQUE AUTOMATIQUES
À USAGE DOMESTIQUE ET ANALOGUE –
Partie 2-3: Règles particulières pour les protecteurs thermiques
des ballasts pour lampes tubulaires à fluorescence
1 Domaine d'application et références normatives
L'article de la Partie 1 s'applique avec les exceptions suivantes:
1.1 Remplacement:
La présente partie de la CEI 60730 s'applique à l'évaluation des protecteurs thermiques des
ballasts pour lampes tubulaires à fluorescence.
La présente norme s'applique aux protecteurs thermiques utilisant des thermistances CTN
ou CTP, dont les exigences complémentaires sont contenues à l'Annexe J.
Les exigences concernant les essais de la combinaison de ballasts et de protecteurs
thermiques sont données dans la CEI 61347-1.
1.1.1 La présente norme s'applique à la sécurité intrinsèque, aux valeurs de fonctionnement,
aux temps de fonctionnement et aux séquences de fonctionnement dans la mesure où ils
interviennent dans la sécurité du matériel, ainsi qu'aux essais des protecteurs thermiques
utilisés pour protéger de la surchauffe les ballasts pour lampes tubulaires.
La présente norme s'applique aux protecteurs thermiques pour ballasts entrant dans le
domaine d'application de la CEI 61347-2-8.
Les protecteurs thermiques couverts par la présente norme peuvent être utilisables avec les
ballasts d'autres lampes à décharge tel que les ballasts couverts par le domaine d'application
de la CEI 61347-2-9.
Partout où il est utilisé dans la présente norme, le terme “protecteur” signifie “dispositif thermique de protection de
ballast à réarmement automatique”.
1.1.2 La présente norme ne s'applique pas à d'autres dispositifs utilisés pour la protection
des ballasts.
1.1.3 La présente norme ne s'applique pas aux dispositifs manuels d'ouverture de circuit.
1.2 Remplacement:
La présente norme s'applique aux protecteurs pour ballasts fonctionnant à partir d'une
alimentation courant alternatif jusqu'à 690 V à 50 Hz ou 60 Hz.
1.3 Remplacement:
La présente norme ne prend pas en considération la valeur de réponse d'une action
automatique d'un dispositif de commande lorsqu'elle est influencée par la méthode de montage
du dispositif de commande dans l'équipement. Dans le cas où une telle valeur de réponse est
importante du point de vue de la protection de l'utilisateur ou de l'environnement, la valeur
spécifiée dans la norme particulière de l'équipement domestique approprié ou prescrite par le
fabricant s'applique.
60730-2-3 © IEC:2006 – 11 –
AUTOMATIC ELECTRICAL CONTROLS
FOR HOUSEHOLD AND SIMILAR USE –
Part 2-3: Particular requirements for thermal protectors
for ballasts for tubular fluorescent lamps
1 Scope and normative references
This clause of Part 1 is applicable except as follows:
1.1 Replacement:
This part of IEC 60730 applies to the evaluation of thermal protectors for ballasts for tubular
fluorescent lamps.
This standard applies to thermal protectors using NTC or PTC thermistors, additional
requirements for which are contained in Annex J.
Requirements concerning the testing of the combination of ballasts and thermal protectors are
given in IEC 61347-1.
1.1.1 This standard applies to the inherent safety, to the operating values, operating times,
and operating sequences where such are associated with equipment safety, and to the testing
of thermal protectors used to protect ballasts for tubular lamps from overheating.
This standard applies to thermal protectors for ballasts within the scope of IEC 61347-2-8.
Thermal protectors covered by this standard may be suitable for ballasts for other discharge
lamps such as ballasts under the scope of IEC 61347-2-9.
Throughout this standard, the word "protector" means "self-resetting thermal ballast protector".
1.1.2 This standard is not applicable to other means used to protect ballasts.
1.1.3 This standard does not apply to a manual device for opening the circuit.
1.2 Replacement:
This standard applies to protectors for use with ballasts for use on a.c. supplies up to 690 V at
50 Hz or 60 Hz.
1.3 Replacement:
This standard does not take into account the response value of an automatic action of a
control, if such a response value is dependent upon the method of mounting the control in the
equipment. Where a response value is of significant purpose for the protection of the user or
surroundings, the value defined in the appropriate household equipment standard or as
determined by the manufacturer applies.
– 12 – 60730-2-3 © CEI:2006
1.5 Références normatives
Addition:
CEI 61347-1, Appareillages de lampes – Partie 1: Prescriptions générales et prescriptions de
sécurité
CEI 61347-2-8, Appareillages de lampes – Partie 2-8: Prescriptions particulières pour les ballasts
pour lampes fluor
...








Questions, Comments and Discussion