ISO 21413:2005 develops procedures and prescribes the minimum accuracy required of water-level measurements made in wells using graduated steel tapes, electric tapes and air lines. Procedures and accuracy requirements for measuring water levels in a flowing well are also included, as are procedures required to establish a permanent measuring point. ISO 21413:2005 discusses the advantages and limitations of each method and requirements for recording the data. ISO 21413:2005 does not include methods that use automated electrical or mechanical means to measure and record water levels.

Méthodes manuelles pour le mesurage du niveau de l'eau souterraine dans un puits

General Information

Status
Published
Publication Date
16-Oct-2005
Current Stage
Ref Project

Buy Standard

Standard
ISO 21413:2005 - Manual methods for the measurement of a groundwater level in a well
English language
30 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 21413
First edition
2005-10-15

Manual methods for the measurement
of a groundwater level in a well
Méthodes manuelles pour le mesurage du niveau de l'eau souterraine
dans un puits




Reference number
ISO 21413:2005(E)
©
ISO 2005

---------------------- Page: 1 ----------------------
ISO 21413:2005(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but
shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In
the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.


©  ISO 2005
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland

ii © ISO 2005 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 21413:2005(E)
Contents Page
Foreword. iv
Introduction . v
1 Scope.1
2 Terms and definitions .1
3 Water-level measurement using a graduated steel tape .2
3.1 Purpose.2
3.2 Materials and instruments .2
3.3 Data accuracy and limitations.2
3.4 Advantages and disadvantages.3
3.5 Assumptions .3
3.6 Procedures.3
4 Water-level measurement using an electric tape .6
4.1 Purpose.6
4.2 Materials and instruments .6
4.3 Data accuracy and limitations.6
4.4 Advantages and disadvantages.7
4.5 Assumptions .7
4.6 Procedures.7
5 Water-level measurement using an air line.10
5.1 Purpose.10
5.2 Materials and instruments .10
5.3 Data accuracy and limitations.10
5.4 Advantages and disadvantages.11
5.5 Assumptions .11
5.6 Procedures.11
6 Water-level measurement in a flowing well .13
6.1 Purpose.13
6.2 Materials and instruments .13
6.3 Data accuracy and limitations.14
6.4 Advantages and disadvantages.15
6.5 Assumptions .15
6.6 Procedures.15
6.6.1 Low-pressure head measurement (direct measurement) .15
6.6.2 High-pressure head measurement (indirect measurement) .15
7 Establishing a permanent measuring point.16
7.1 Purpose.16
7.2 Materials and instruments .16
7.3 Data accuracy and limitations.17
7.4 Assumptions .17
7.5 Procedure.17
Annex A (informative) Corrections for water levels measured in deep wells by steel tapes subject
to temperature changes and tape stretch .26
Annex B (informative) Corrections for water levels measured in wells with the air-line method.28
Bibliography .30

© ISO 2005 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 21413:2005(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 21413 was prepared by Technical Committee ISO/TC 113, Hydrometry, Subcommittee SC 8, Ground
water.
iv © ISO 2005 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 21413:2005(E)
Introduction
The measurement of a water level in a well constitutes a data-collection process that provides fundamental
information about the status of a groundwater system. Accordingly, measured water levels should be
sufficiently accurate and reproducible to meet the needs of most data-collection and monitoring programs.
Several manual methods commonly used to collect water-level data in wells employ relatively simple
measuring devices such as graduated steel tapes, electric tapes, and air lines. In some cases, water-level
measurements are required in flowing wells. The procedures associated with each of these methods are
intrinsically different and subject to varying limitations and accuracies. Standardization of these methods
would ensure that the procedures and associated equipment used by the international community to collect
water-level data in a well are consistent, and that the results can be compared with minimal concern about the
relative accuracies and/or the procedures use in collecting the data.

© ISO 2005 – All rights reserved v

---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 21413:2005(E)

Manual methods for the measurement of a groundwater level in
a well
1 Scope
This International Standard develops procedures and prescribes the minimum accuracy required of water-
level measurements made in wells using graduated steel tapes, electric tapes and air lines. Procedures and
accuracy requirements for measuring water levels in a flowing well are also included, as are procedures
required to establish a permanent measuring point. This International Standard discusses the advantages and
limitations of each method and requirements for recording the data. This International Standard does not
include methods that use automated electrical or mechanical means to measure and record water levels.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply:
2.1
air line
water-level measuring device consisting of a small diameter open-ended tube fixed in position that is
accessible from the top of the casing and extends to below the water level in a well where pressurized air
measurements can be used to determine the depth to water
2.2
casing (well casing)
tubular retaining structure, which is installed in a drilled borehole or excavated well, to maintain the borehole
opening. Plain (unscreened) casing prevents the entry of water and fine material into the well, while open
(screened) casing allows water ingress but should exclude fines
2.3
electric tape
water-level measuring device that uses an electrical signal, sent through a cable with fixed distance marks, to
determine the water level relative to a fixed reference point. The electrical signal, which is induced when the
sensor makes contact with the water surface, activates an indicator (typically a light, buzzer or needle)
2.4
flowing well (or overflowing well)
well from which groundwater is discharged at the ground surface without the aid of pumping
NOTE A deprecated term for this definition is an artesian well.
2.5
graduated steel tape
water-level measuring device consisting of a flat measuring tape with permanently fixed distance marks that
can be wound on a reel
2.6
groundwater
water within the saturated zone
© ISO 2005 – All rights reserved 1

---------------------- Page: 6 ----------------------
ISO 21413:2005(E)
2.7
land surface datum
average altitude of land surface at a referenced well
2.8
measuring point
permanent reference marked on well casing
2.9
static water level (or static head)
height, relative to an arbitrary reference level, of a column of water that can be supported by the static
pressure at a given point
2.10
well
hole sunk into the ground for abstraction of water or for observation purposes
3 Water-level measurement using a graduated steel tape
3.1 Purpose
The purpose of this method is to measure the depth to the water surface (level) below a measuring point using
the graduated steel tape (wetted-tape) method.
3.2 Materials and instruments
The following materials and instruments are required.
3.2.1 Steel tape graduated in metres and centimetres.
A black tape is preferred to a chromium-plated tape because the wetted chalk mark is easier to read against a
black tape. A break-away weight should be attached to the ring on the end of the tape with wire strong enough
to hold the weight, but not as strong as the tape, so that if the weight becomes lodged in the well, the tape can
still be pulled free. The weight should be made of brass, stainless steel or iron.
3.2.2 Coloured chalk.
3.2.3 Clean cloth.
3.2.4 Pencil and eraser.
3.2.5 Steel tape calibration and maintenance equipment log book.
3.2.6 Water-level measurement field form (see the example in Figure 6).
3.2.7 Equipment to gain access to the well (wrenches, crow bars, manhole keys, etc.).
3.2.8 Common household chlorine bleach or other suitable disinfectant.
3.3 Data accuracy and limitations
The following data accuracy and limitations apply.
a) Independent graduated steel tape measurements of static water levels should agree within ± 1,0 cm for
depths of less than 60 m;
2 © ISO 2005 – All rights reserved

---------------------- Page: 7 ----------------------
ISO 21413:2005(E)
b) For depths between 60 m and 150 m, independent measurements using the same tape should agree
within ± 2,0 cm. When measuring deep water levels (i.e. greater than 300 m), errors due to the effects of
thermal expansion and of stretch produced by the suspended weight of the tape and plumbing weight
warrant consideration (see Reference [2], p. 3). An example of correcting a deep water level for thermal
expansion and stretch of a steel tape is given in Annex A. However, because the equipment required to
measure temperatures at land surface and down the well may not always be readily available, the
corrections described in Annex A are not required for the purposes of this International Standard, though
the practitioner shall note on the water-level field form (see the example in Figure 6) whether or not any
such corrections were applied.
c) At least once every twelve months, the steel tape should be calibrated against another steel tape that is
dedicated as a calibration tape and is not used in the field. If the steel tape does not meet test criteria,
then it must be removed from service. Records of these tests shall be kept.
d) If the well casing is angled, instead of vertical, the depth to water will have to be corrected. If the casing
angle is unknown and a correction is not feasible, this should be noted in water-level measurement field
form (see the example in Figure 6).
3.4 Advantages and disadvantages
The graduated steel tape method is easy to use and is considered to be the most accurate method for
measuring the water level in nonflowing wells of moderate depth. However, it may be impossible to get
reliable results if water is dripping into the well or condensing on the well casing. Also, the method is not
recommended for measuring pumping levels in wells.
3.5 Assumptions
The following assumptions apply in the use of the graduated steel tape method.
a) An established measuring point (MP) exists and the distance from the MP to land-surface datum (LSD) is
known (see the example in Figure 6). See the technical procedure described in Clause 7 for establishing
a permanent MP.
b) The MP is clearly marked and described so that all measurements will be taken from the same point.
c) The results from previous water-level measurements made at the well are available for estimating the
length of the required tape.
d) The steel tape will retain the chalk.
e) The well is free of obstructions. Well obstructions, if present, could cause errors in the measurement if the
obstructions affect the plumbness of the steel tape.
3.6 Procedures
The following procedures for measuring water levels in a well with a graduated steel tape shall be observed.
a) Apply the coloured chalk to the lower metre of the tape by pulling the tape across the chalk. The wetted
chalk mark will identify that part of the tape that was submerged.
b) Lower the weight and tape into the well until the lower end of the tape is submerged below the water
(more than one attempted measurement may be needed to determine the length of tape required to
submerge the weight). Once the end of the tape is submerged, continue to lower the tape into the well
until the next whole metre graduation mark is opposite the MP. This whole number shall be recorded in
the “MP HOLD” (Figure 1) column of the water-level measurements field form (see the example in
Figure 6).
© ISO 2005 – All rights reserved 3

---------------------- Page: 8 ----------------------
ISO 21413:2005(E)
c) Pull the tape back to the surface before the wetted chalk mark dries and becomes difficult to read. Record
the number of the wetted chalk mark (sometimes referred to as the cut) in the “WETTED CHALK MARK”
(Figure 1) column of the water-level measurements field form (see the example in Figure 6).
d) Subtract the wetted chalk mark number from the number held to the MP, and record this number in the
“DEPTH TO WATER FROM MP” (Figure 1) column of the water-level measurements field form (see the
example in Figure 6). The difference between these two readings is the depth to water below the MP.
e) Apply the MP correction to get the depth to water below or above land-surface datum (LSD). If the MP is
above land surface (see the example in Figure 6), the distance between the MP and land surface datum
is subtracted from the depth to water from the MP (see the example in Figure 6) to obtain the depth to
water below land surface. If the MP is below land surface, precede the MP correction value with a minus
(−) sign and subtract the distance between the MP and land surface datum from the depth to water from
the MP to obtain the depth to water below land surface. Record this number in the “DEPTH TO WATER
FROM LSD” (Figure 1) column of the water-level measurements field form (see the example in Figure 6).
If the water level is above LSD, record the depth to water above land surface as a negative number.
f) Make a check measurement by repeating steps a) through e). The check measurement shall be made
using a different MP hold value (see the example in Figure 6) than that used for the original measurement.
If the check measurement does not agree with the original measurement to the nearest centimetre,
continue to make check measurements until the reason for the lack of agreement is determined or until
the results are shown to be reliable. If more than two readings are taken, the observer shall select the
reading considered the most reliable. This reading shall be recorded to the nearest centimetre.
g) After completing the well measurements, disinfect the steel tape and weight by pouring a small amount of
common household chlorine bleach or other suitable disinfectant on a clean cloth and wiping down the
part of the tape that was submerged below the water surface. This will avoid possible contamination of
other wells.
h) The tape shall be maintained in good working condition by periodically checking the tape for rust, breaks,
kinks and possible stretch due to the suspended weight of the tape and the tape weight.
All calibration and maintenance data associated with the steel tape being used shall be recorded in its
calibration and maintenance equipment log book. All water-level data shall be recorded on the water-level
measurements field form (see the example in Figure 6) to the nearest centimetre.
In some contaminated or pumped wells, a layer of oil may be floating on the surface of the water. In such
cases, if the thickness of the oil layer is several centimetres or less, the tape reading made at the top of the oil
mark can be used as the water-level measurement. The associated error in this case should be relatively
small because the level of the oil surface would differ only slightly from the level of the water surface that
would be measured if no oil were present. If a meter of more of oil is present, however, or if it is deemed
necessary to ascertain the thickness of the oil layer, a commercially-available water-detection paste, originally
developed to detect water in gasoline storage tanks, is available to do so. The paste can be applied to the end
of the measuring tape that is lowered into the well. The top of the oil layer will be reflected as a wet line on the
tape, while the top of the water will be shown by a distinct colour change. In either event, whether the oil layer
is greater than or less than a few millimetres in thickness, its presence should be noted on the water-level
measurements field form (see the example in Figure 6). A specialized interface probe is also commercially
available for measuring the interface.
In the event no water is encountered in the well, this shall be duly noted under “REMARKS” on the field form,
along with the distance between the MP and the bottom of the well.
4 © ISO 2005 – All rights reserved

---------------------- Page: 9 ----------------------
ISO 21413:2005(E)
Dimensions in metres

Key
1 measuring point (MP)
2 MP hold
3 land surface datum (LSD)
4 water level
5 depth to water from LSD = 12,86
6 depth to water from MP = 13,71
7 wetted chalk mark
Figure 1 — Water-level measurements using a graduated steel tape
© ISO 2005 – All rights reserved 5

---------------------- Page: 10 ----------------------
ISO 21413:2005(E)
4 Water-level measurement using an electric tape
4.1 Purpose
The purpose of this method is to measure the depth to the water surface below a measuring point using the
electric tape method.
Electric tapes fall into two categories:
⎯ Type 1 those that have fixed graduations lacking a suitable frequency (e.g. 1 m graduation) that would
enable readings to be made at a sufficient accuracy without the use of additional graduated measures
(e.g. tapes calibrated in centimetres). Type 1 tapes are referred to as “partially graduated” tapes in the
rest of this clause; and
⎯ Type 2 those with fixed graduations which are spaced at lengths equal to or smaller than the accuracy
required for the readings. Type 2 tapes are referred to as “fully graduated” tapes in the rest of this clause.
4.2 Materials and instruments
The following materials and instruments are required.
4.2.1 Electric tape of various wiring arrangements or configurations, that would include flat parallel or
co-axial conductive wires, graduated in metres and/or centimetres. Electric tapes are commonly mounted on a
hand-cranked supply reel that contains space for the batteries and some device for signalling when the circuit
is closed (Figure 2).
4.2.2 Electric tape calibration and maintenance equipment log book.
4.2.3 Pencil and eraser.
4.2.4 Water-level measurement field form (Tables 2 and 3).
4.2.5 Equipment to gain access to the well (wrenches, crow bars, manhole keys, etc.).
4.2.6 Common household chlorine bleach, and, for measurements made with Type 1, electric tapes.
4.2.7 Steel tape graduated in metres and centimetres.
4.2.8 Spare batteries.
4.3 Data accuracy and limitations
The following data accuracy and limitations apply.
a) Independent electric tape measurements of static water levels using the same tape should agree within
± 1,0 cm for depths of less than 60 m.
b) For depths of about 150 m, the maximum difference of independent measurements using the same tape
should agree within ± 3,0 cm.
c) For depths in the 500 m range, the repeatability of measurements using the same tape should agree
within ± 15 cm (see Reference [2], p. 11).
6 © ISO 2005 – All rights reserved

---------------------- Page: 11 ----------------------
ISO 21413:2005(E)
4.4 Advantages and disadvantages
The electric tape method is superior to the graduated steel tape method when
a) water is dripping into the well or condensing on the inside of casing walls which may make it very difficult
to get a good water mark on the chalked tape,
b) wells are being pumped and the splashing of the water surface makes chalked measurements virtually
impossible, and
c) a series of measurements are needed in quick succession, such as in aquifer tests, because the electric
tape does not have to be removed from the well for each reading.
Also, the electric tape method is safer to use in pumping wells because the water is sensed as soon as the
probe reaches the water surface and there is less danger of lowering the tape into the pump impellers.
Electric tape measurements are generally less accurate than are measurements made with graduated steel
tapes. Electric tapes are also harder to keep calibrated than are steel tapes and electric connections need to
be maintained in good order. Also, the insulation around the conductor cables may be severed when being
drawn across sharp edges of metal pipes at the top of a borehole. In addition, the presence of hydrocarbons
on the water surface that may result from oil leaks during drilling operations may coat the sonde, resulting in a
failure to complete the electrical circuit. Finally, a stilling pipe may be required to avoid inaccurate readings
where water is cascading down the borehole during pumping (aquifer) tests.
In general, fully graduated tapes are preferred to partially graduated tapes. Fully graduated tapes are easier to
use and there are fewer opportunities for errors in measurement, particularly when the time intervals between
measurements are small such as during pumping tests.
4.5 Assumptions
Application of the electric tape method assumes
a) that an established measuring point (MP) exists; and
b) if the water level is to be referenced to land surface, that the distance between the MP and land-surface
datum (LSD) is known (see the example in Figure 7).
See the technical procedure described in Clause 7 for establishing a permanent MP.
Also, the MP should be clearly marked and described so that all measurements will be taken from the same
point.
If the MP of record cannot be located, the use of data for assessing long-term trends may be compromised. In
such cases, a new MP should be established and the date of change should be indicated on the record sheet.
4.6 Procedures
The following procedures for measuring water levels in a well with an electric tape shall be observed.
a) Prior to using an electric tape in the field, calibrate it by comparing the total length of the electric tape
against the length of an acceptable steel tape. An acceptable steel tape is one that has a fixed graduation
of a centimetre (or less) and that is maintained in the office for the sole purpose of calibrating electric
tapes. Also, check the accuracy of the position of each 1 m interval metal band to make sure that the
bands have not moved. This is especially important if the electric tape has been used for a long time or
after it has been pulled hard in attempting to free the line. If the field tape fails to meet test criteria, then it
must be removed from service. Records of these tests shall be kept.
© ISO 2005 – All rights reserved 7

---------------------- Page: 12 ----------------------
ISO 21413:2005(E)
b) Before lowering the probe into the well, check the circuitry of the electric tape by dipping the probe into
water and observe if the indicator (needle, light, or buzzer) is operating correctly as the circuit closes.
Note the position the indicator needle deflects during the circuitry check.
c) Lower the electrode probe slowly into the well until contact with the water surface causes the circuit to
close, activating the indicator (Figure 2). Slightly raise and then lower the electrode again to identify just
where the electrode first comes into contact with the surface of the water. Once
...