INTERNATIONAL STANDARD 1502
~~ ~ ~
INTERNATIONAL ORGANIZATION FOR STANDARDIZATlON~MEXLlYHAPO4HAR OPrAHHJAUHR no CTAH4APTH3AUHH.ORGANlSATlON INTERNATIONALE DE NORMALISATION
-
IS0 general purpose metric screw threads - Gauging
Filetages métriques IS0 pour usages généraux - Vérification par calibres à limites
First edition - 1978-07-15
I
Lu
-
UDC 621.882.082 Ref. No. IS0 1502-1978 (E)
2
Descripton : screw threads, IS0 screw threads, gauges, thread gauges, plug gauges, inspection, dimensions, dimensional tolerances, cornpu-
(v
O In tation, formulae (mathematics).
-
z
Price based on 22 pages

---------------------- Page: 1 ----------------------
FOREWORD
IS0 (the International Organization for Standardization) is a worldwide federation
of national standards institutes (IS0 member bodies). The work of developing
is carried out through IS0 technical committees. Every
International Standards
member body interested in a subject for which a technical committee has been set
up has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the technical committees are circulated
to the member bodies for approval before their acceptance as International
Standards by the IS0 Council.
International Standard IS0 1502 was developed by Technical Committee ISO/TC 1,
Screw threads. It was submitted directly to the IS0 Council, in accordance with
clause 6.13.1 of the Directives for the technical work of ISO. It cancels and replaces
IS0 Recommendation R 1502-1970, which had been approved by the member
bodies of the following countries :
Austria
India Portugal
Belgium
Israel Romania
Chile
Italy South Africa, Rep. of
Czechoslovakia Japan Spain
Denmark
Korea, Rep. of Sweden
Egypt, Arab Rep. of
Netherlands Thailand
France
Norway Turkey
Germany
Peru United Kingdom
Hungary
Poland
The member bodies of the following countries had expressed disapproval of the
document on technical grounds :
Australia* Sw itzer I a nd *
Canada U.S.A.
New Zealand* U.S.S.R .*
* Subsequently these member bodies indicated their approval of International Standard
IS0 1502.
O International Organization for Standardization, 1978
Printed in Switzerland

---------------------- Page: 2 ----------------------
CONTENTS Page
1 Scope and field of application . 1
2 References . 1
3 Typesofgauges . 1
3.1 Gauges for workpiece external threads and their check plugs and setting
plugs . 1
3.2 Gauges for workpiece internal threads . 1
4 Gauging of workpieces . 2
4.1 Gauging of external threads . 2
4.2 Gauging of internal threads . 2
4.3 Inspection gauging . 2
5 Reference temperature . 3
6 Symbols and explanations . 3
7 Function, checking and use of gauges . 4
7.1 Gauges for workpiece external threads and their check plugs and setting
plugs . 4
7.2 Gauges for workpiece internal threads . 6
8 Tolerance zones for pitch diameter of screw gauges . 7
9 Tolerance zones for plain gauges . 10
10
Thread profiles for gauges . 11
10.1 Profiles with complete flanks . 11
10.2 Profiles with truncated flanks . 14
11 General features of screw gauges . 16
1 1 . 1 Gauges for workpiece external threads . 16
11.2 Gaugesforworkpiece internal threads . 17
11.3
Blunt start of thread . 17
12 Tolerances and permissible wear for gauges . 18
13
Formulae for calculation of gauge limits . 20
13.1 Screw gauges for external threads . 20
13.2 Plain gauges for the major diameter . 22
13.3 Screw gauges for internal threads . 22
13.4 Plain gauges for the minor diameter . 22
iii

---------------------- Page: 3 ----------------------
~
IS0 1502-1978 (E)
INTERNATIONAL STANDARD
IS0 general purpose metric screw threads - Gauging
3 TYPES OF GAUGES
1 SCOPE AND FIELD OF APPLICATION
This International Standard specifies the essential features
This International Standard gives the necessary instructions
of the types of gauges’) listed in 3.1 and 3.2 which are
for the manufacture and use of gauges for checking IS0
recommended for the checking of workpiece external and
general purpose metric screw threads complying with
internal screw threads and for the setting and checking
IS0 68 and IS0 261.
of certain of the screw gauges.
It is recognized that other methods of checking may be
used, for example measurement with indicating instru-
3.1 Gauges for workpiece external threads and their check
ments. Checking with gauges in accordance with this
International Standard is always decisive. plugs and setting plugs
- Solid GO screw ring gauge
The aim of this International Standard is to provide means
of distinguishing between workpiece threads that comply
- Adjustable GO screw ring gauge
with the limits of size and those that do not.
- Check plugs (GO and NOT GO) for new solid GO
In order to ensure the interchangeability of workpiece
screw ring gauge
threads and to avoid disputes between manufacturer and
:
purchaser, the following principles should be applied - Setting plug for adjustable GO screw ring gauge
a) the manufacturer shall not deliver any workpiece
- Wear check plug for solid or adjustable GO screw
thread the actual thread size (for example the pitch
ring gauge
diameter and the virtual pitch diameter) of which lies
- GO screw calliper gauge
outside the specified limits;
- Setting plug for GO screw calliper gauge
b) the purchaser shall not reject any workpiece thread
the actual thread size (for example the pitch diameter
- NOT GO screw calliper gauge
lies inside the
and the virtual pitch diameter) of which
specified limits. - Setting plug for NOT GO screw calliper gauge
L
In order to satisfy these two principles, this International - Solid NOT GO screw ring gauge
Standard establishes the requisite types and sizes of gauges
- Adjustable NOT GO screw ring gauge
for the checking of screw threads, the conditions under
which these gauges are to be used and rules for the
- Check plugs (GO and NOT GO) for new solid NOT
inspection of the workpiece threads.
GO screw ring gauge
- Setting plug for adjustable NOT GO screw ring gauge
2 REFERENCES
- Wear check plug for solid or adjustable NOT GO
IS0 1, Standard reference temperature for industrial length
screw ring gauge
measurements.
- Plain gauges for major diameter (ring or calliper
IS0 68, IS0 general purpose screw threads - Basic profile.
gauges)
IS0 261, IS0 general purpose screw threads - General
plan.
3.2 Gauges for workpiece internal threads
ISO965/1, IS0 general purpose metric screw threads -
- GO screw plug gauge
Tolerances - Principles and basic data.
- NOT GO screw plug gauge
ISO/R 1938, IS0 system of limits and fits - PartII:
- Plain gauges for minor diameter (plug gauges)
Inspection of plain workpieces.
1 i The GO and NOT GO gauges may be combined.
1

---------------------- Page: 4 ----------------------
IS0 1502 -1 978 (E)
4 GAUGING OF WORKPIECES 4.3 Inspection gauging
It is not necessary to use all the gauges mentioned in
4.3.1 By the manufacturer
clause 3 in the workshop or inspection department. How-
Generally speaking, the inspection department that checks
ever, in gauging the limits (checking that the tolerances
the threads made in the workshop may use the same kind of
have been respected), it is essential that a GO and NOT
gauges as are used in the workshop.
GO gauging always be carried out with one of the GO
GO screw gauges referred
screw gauges and one of the NOT
Disagreement between manufacturing and inspection can
to above.
occur when products close to the limits of sizes are gauged.
When disputes do arise, it is recommended that the product
shall be accepted if it is shown to be satisfactory by any
4.1 Gauging of external threads
gauge of the type concerned known to be within the
A solid or adjustable GO screw ring gauge should preferably
requirements of this International Standard (taking into
be used for gauging an external thread.
consideration the admissible wear).
In cases of dispute, checking of the ring gauges by check
To save time, for convenience in checking, or in cases where
plugs is decisive, if there is no other agreement between
the GO screw ring gauge is not applicable, a GO screw
manufacturer and purchaser.
calliper gauge may be employed.
NOTE - The possibility of disputes can be reduced to a minimum
so that those used by manufacturers provide a
It is, however, recommended that a gauging with GO screw by grading the gauges
more stringent check than those used by inspection. Generally, this
calliper gauges should be supplemented by random
can be achieved by issuing to the workshops new or only slightly
sampling with the GO screw ring gauge, so that when a
worn GO gauges and slightly worn NOT GO gauges. Inspection
large number of parts is checked with a GO screw calliper
of
should use GO gauges which are approaching the condition
gauge, a certain percentage receives an additional check
maximum permissible wear and new NOT GO gauges.
with a GO screw ring gauge, thus giving greater assurance
of interchangeability between the workpiece threads.
4.3.2 By the purchaser
There are three possible procedures, as listed below, for
The GO screw calliper gauge should not be used if the
inspection of workpiece threads on behalf of the purchaser
manufacturing process is likely to cause deviations in the
by an inspector who does not belong to the manufacturing
workpiece thread, which this gauge is not certain to detect,
plant concerned.
for example local pitch errors in milled threads or burrs at
the start of the thread. Further, the GO screw calliper gauge
a) The inspector gauges the workpiece threads with the
is not suitable for checking non-rigid parts, for example
manufacturer's gauges.
thin-walled parts which would be deformed by this gauge.
In these cases, checking should be carried out with a GO In this case, he may check the accuracy of the gauges
screw ring gauge. employed by means of check plugs and setting plugs
which belong either to the manufacturing plant (manu-
facturer) or to the inspector (purchaser) or as far as
The NOT GO screw calliper gauge is used for checking the
,
screw plugs are concerned by direct measurement. .
simple pitch diameter of the external thread on the NOT
GO side.
b) The inspector uses his own gauges for gauging work.
piece th read s.
The solid or adjustable NOT GO screw ring gauge should
In cases of dispute it is recommended that the product
only be used for non-rigid workpieces, for example thin-
walled parts, which would be deformed by checking with a
shall be accepted if it is shown to be satisfactory by any
NOT GO screw calliper gauge. gauge of the type concerned known to be within the
requirements of this International Standard (taking into
consideration the admissible wear).
For gauging the major diameter of the workpiece external
GO gauges are used. Whether
thread the plain GO and NOT
c) The inspector uses his own inspection gauges for
a calliper or ring gauge will be used is determined by the
gauging the workpiece threads.
form and rigidity of the workpiece. Ring gauges should be
used for non-rigid parts.
The position of the tolerance zone for these gauges shall
be such as to ensure that the purchaser does not reject
threads the actual size of which lies within the limits
4.2 Gauging of internal threads
specified for the workpiece.
For the gauging of workpiece internal thread the GO screw
This International Standard does not specify which gauges
plug gauge and NOT GO screw plug gauge are used.
are to be used by the inspector; it only recommends that
the purchaser informs the manufacturer when ordering
For gauging the minor diameter of the workpiece internal what procedure will be employed for the inspection of the
thread the GO plain plug gauge and NOT GO plain plug workpiece threads. Worn gauges shall not be used for
gauge are used. sample inspection.
2

---------------------- Page: 5 ----------------------
IS0 1502-1978 (E)
5 REFERENCE TEMPERATURE linear expansion (for example steel workpieces and carbide
gauges or brass workpieces and gauges of steel or carbide),
In accordance with IS0 1, the dimensions of both the gauge
the temperature of both shall be 20 k 2 "C at the time of
and the workpiece are related to a temperature of 20 "C.
gauging. Otherwise the difference of the thermal expansion
of the workpiece and of the gauge shall be taken into
If the workpieces and the gauges have the same coefficient
consideration.
of linear expansion (for example steel workpieces and steel
gauges), the checking temperature may deviate from 20 "C
without detriment to the result, provided that the
temperatures of both gauges and workpieces are about the 6 SYMBOLS AND EXPLANATIONS
same.
In the list given below, the symbols mentioned in this
If the workpieces and gauges have different coefficients of International Standard are summarized and explained.
Symbols and explanations
Symbol
Symbol Explanation
Width of the clearance groove at the major diam-
b1
complete flanks
I eter of the thread profile with complete flanks
Tolerance for the flank angle of profiles with
Width of the clearance groove at the minor diam-
b2
truncated flanks
eter of the thread profile with complete flanks
I
Tolerance for the pitch diameter of GO and NOT
Width of the clearance groove at the major and
TCP
minor diameter respectively of the thread profile GO screw check plugs and wear check plugs and
b3 I with truncated flanks setting plugs
[ Basic major diameter of the workpiece thread Tolerance for the major diameter of the workpiece
d, D
'd
Basic minor diameter of the internal workpiece
thread Tolerance for the pitch diameter of the workpiece
'd 2
~~
external thread
TD27ûasic pitch diameter of the workpiece thread
Tolerance for the minor diameter of the workpiece
TDi
Fundamental deviation of the external thread (for
internal thread
I
tolerance position h the fundamental deviation es
es I is equal to zero) Tolerance for the pitch diameter of the workpiece
'D2
El Fundamental deviation of the internal thread (for
tolerance position H the fundamental deviation €I
TP
~
is equal to zero)
Tolerance for the pitch diameter of GO and NOT
TP L
GO screw plug gauges
For thread profiles with truncated flanks the radial
I
Fl
distance between the pitch diameter line and the
Tolerance for the pitch diameter of GO and NOT
end of the straight part of the flank in the direction TR
GO screw ring gauges
of the crest
Average amount available for the permissible wear
For thread profiles with truncated flanks the radial WGO
F2
of GO screw plug gauge and GO screw ring gauge
distance between the pitch diameter line and the I
end of the straight part of the flank in the direction
Average amount available for the permissible wear
WN G
of the root
of the NOT GO screw plug gauge and NOT GO
screw ring gauge
H I Height of the triangle of the thread profile
Distance between the middle of the tolerance zone
I Tolerance for plain plug gauges Zl
H,
H1 of the GO plug gauge and the lower limit of the
workpiece minor diameter
Tolerance for plain calliper gauges and plain ring
H2 I gauges
Distance between the middle of the tolerance zone
H2 of the GO calliper gauge or the GO ring gauge
Tolerance for reference gauges for plain calliper
Hp
and the upper limit of the workpiece major
gauges
diameter
m
Distance between the middle of the tolerance
T, of the screw ring gauge and TCp of the Distance between the middle of the tolerance zone
zones
ZP L
TPL of the GO screw plug gauge and the lower limit
GO check plug
of the workpiece thread
P Pitch
Distance between the middle of the tolerance zone
s Displacement of the clearance groove with truna T, of the GO screw ring gauge and the upper limit
ated flanks of the workpiece thread
I
3

---------------------- Page: 6 ----------------------
IS0 1502-1978 (E)
7 FUNCTION, CHECKING AND USE OF GAUGES The NOT GO screw check plug screwed by hand,
without using excessive force, may enter into both ends
Throughout this clause, the designations of paragraphs
of the new solid GO screw ring gauge, but not more than
are as follows :
one turn of thread’ ).
a) = function; b) = control; c) = use.
7.1.3 Setting plug for adjustable GO screw ring gauge
7.1 Gauges for workpiece external threads and their
check plugs and setting plugs
a) The setting plug which contains two successive
portions, one with complete flanks and the other with
7.1 .I Solid or adjustable GO screw ring gauge
truncated flanks, is used to set the adjustable GO screw
ring gauge to the specified pitch diameter.
a) The GO screw ring gauge checks the virtual size of
the external thread on the GO side (gauging the virtual
It is not essential to use a double length setting plug if
pitch diameter), i.e. it checks the maximum material
the GO screw ring gauge is checked with a NOT GO
limit of the pitch diameter, taking into account
screw check plug (see 7.1.2) after it has been adjusted.
deviations of form (departures from roundness, lack of
b) The GO screw ring gauge is set on the portion of the
straightness of the thread axis over the gauge length) and
setting plug with complete flanks.
pitch errors, helix variations, errors in the flank angles,
4
which produce an apparent enlargement of the pitch
c) The portion with complete flanks screwed by hand,
diameter (virtual pitch diameter) of the workpiece. In
without using excessive force, shall pass through the GO
addition, this gauge checks whether the length of the
screw ring gauge.
straight flank is adequate, i.e. that the rounding at the
root of the profile does not encroach too far upon the
When the portion with truncated flanks of the setting
flank of the thread. The major diameter of the external
is screwed through the screw ring gauge, no per-
plug
thread is not checked by this gauge.
ceptible clearance is permissible between the plug and
the ring. If there is a clearance, the ring gauge shall be
Checking with the GO screw ring gauge is essentially in
lapped and adjusted to correct form and size.
accordance with the Taylor principle.
b) The solid GO screw ring gauge manufactured accord-
ing to the prescribed sizes is checked by the GO and 7.1.4 Wear check plug for solid adjustable GO screw ring
NOT GO screw check plugs and should regularly be
gauge
controlled with the wear check plug.
a) The wear check plug is used to ascertain that the
If the NOT GO check plug is not used, other provisions pitch diameter of the GO screw ring gauges has not
so as to ensure that the maximum size of exceeded the wear limit. It embodies the pitch diameter
must be made
the pitch diameter of the GO screw ring gauge is not of the GO screw ring gauge at the prescribed limit of
exceeded. wear.
c) The wear check plug screwed by hand, without
The adjustable GO screw ring gauge is set to its setting
excessive force, may enter into both ends of the GO
plug and shall regularly be controlled with the wear
screw ring gauge, but not more than one turn of
check plug.
thread’ ).
c) The GO screw ring gauge screwed by hand, without
If it can be screwed in more than one turn of thread,
using excessive force, shall pass over the whole length of
the GO screw ring gauge no longer meets the
the workpiece thread. It this is not possible, the work-
specifications.
piece thread does not comply with the specifications.
7.1.2 Screw check plugs for new solid GO screw ring gauge
7.1.5 GO screw calliper gauge
a) These screw check plugs (GO and NOT GO) are used
a) This gauge checks the maximum limit of the pitch
to check the limits of the pitch diameter of the new
diameter in an axial plane, as apparently increased by
solid GO screw ring gauge. The GO screw check plug
errors of pitch and flank angle in the workpiece. Further-
checks the GO limit of the total profile of the appro-
more it checks whether the length of the straight flank
priate new solid GO screw ring gauge.
is adequate, for example that the rounding of the root
of the profile does not encroach too far upon the flank
c) The GO screw check plug screwed by hand, without
using excessive force, shall pass through the new solid of the thread. The major diameter of the external
is not checked.
GO screw ring gauge. thread, however,
1) The one turn of thread is determined when withdrawing the check plug.
4

---------------------- Page: 7 ----------------------
IS0 1502-1978 (E)
With regard to the embodiment of the virtual pitch 7.1.8 Setting plug for NOT GO screw calliper gauge
diameter, the GO screw calliper gauge seriously violates
a) With this setting plug the anvils of the NOT GO
the Taylor principle (periodic errors of pitch and
calliper gauge are set.
deviations of form, such as departures from roundness
are not detected).
c) The NOT GO screw calliper gauge shall pass over the
setting plug under its own weight or under a fixed load.
b) The GO screw calliper gauge shall be set with the
If it is not possible or if there is a clearance, the NOT
setting plug specified.
GO screw calliper gauge anvils shall be adjusted.
c) Workpiece threads are generally checked by the GO
When put on the setting plug, the NOT GO screw
screw calliper gauge under its own weight or in accord-
calliper gauge may be moved slightly to and fro in a
ance with a fixed working load to correspond with the
circumferential direction.
method of adjustment of the gauge.
The GO screw calliper gauge shall accept the workpiece
7.1.9 Solid or adjustable NOT GO screw ring gauge
thread at least at three positions, evenly distributed over
a) The NOT GO screw ring gauge is intended to check
the whole circumference of the thread. If this is not
whether the actual pitch diameter exceeds the specified
possible, the workpiece thread does not comply with
minimum size. The checking with the NOT GO screw
the specification.
ring gauge does not correspond to the Taylor principle
When put on the workpiece the GO screw calliper gauge
when checking rigid workpieces. In cases of non-rigid
may be moved slightly to and fro in a circumferential
workpieces, the departure from the Taylor principle is
direction in order to minimise the effects of friction.
of less importance because of the flexibility of the
work pieces.
In cases of dispute, gauging with the GO screw ring
gauge, preferably of the solid type, is decisive.
b) The solid NOT GO screw ring gauge manufactured
according to the prescribed sizes shall be checked by
the GO and NOT GO screw check plugs and shall
7.1.6 Setting plug for GO screw calliper gauge
regularly be controlled with the wear check plug.
a) With this setting plug the anvils of the GO calliper
If the NOT GO check plug is not used, other provisions
gauge are set.
shall be made to ensure that the maximum limit of the
c) The GO screw calliper gauge shall pass over the
pitch diameter of the new NOT GO screw ring gauge is
setting plug under its own weight or under a fixed work-
not exceeded.
ing load. If this is not possible or if there is a clearance,
The adjustable NOT GO screw ring gauge shall be set
the anvils of the GO screw calliper shall be adjusted.
with the setting plug specified and regularly controlled
When put on the setting plug, the GO screw calliper with the wear check plug.
gauge may be moved slightly to and fro in a circum-
c) The NOT GO screw ring gauge, screwed by hand
ferential direction.
without using excessive force on the workpiece thread,
may enter on both sides but not more than two turns
L. 7.1.7 NO T GO screw calliper gauge
of thread’ ). If the gauge can be screwed on the work-
piece more than two turns of thread, the thread does
a) The NOT GO screw calliper gauge checks the
GO screw
not comply with the specifications. The NOT
minimum limit of the pitch diameter. It operates very
ring gauge shall not pass completely over a workpiece
largely in accordance with the Taylor principle.
having a length of thread of three threads or less.
b) The NOT GO screw calliper gauge shall be set with
the setting plug specified. 7.1.10 Screw check plugs for new solid NOT GO screw
ring gauge
c) The NOT GO screw calliper gauge shall not pass over
the workpiece, except for the first two threads of the
The check plugs (GO and NOT GO) are used to
a)
workpiece thread. The checking shall be carried out
check the pitch diameter limits of the new solid NOT
as the adjustment by means
under the same conditions
GO screw ring gauge. The GO screw check plug makes
of the setting plug; it shall take place in at least three
sure that the clearing diameter of the new NOT GO solid
positions, evenly distributed over the circumference.
is not too small.
screw ring gauge
a wear check plug for the NOT GO screw ring gauge
If the gauge corresponds to figure lob) each gauging If
is provided, the NOT GO check plug may be dispensed
shall be repeated by displacing the gauge from one pitch
with.
to the other.
~~
The two turns of thread are determined when withdrawing the gauge.
1)
5

---------------------- Page: 8 ----------------------
IS0 1502-1978 (E)
7.1 .I3 Gauges for the major diameter
c) The GO screw check plug screwed by hand, without
using excessive force, shall pass through the correspond-
a) The major diameter of the workpiece thread is
ing new solid NOT GO screw ring gauge.
gauged by means of plain GO and NOT GO calliper
The NOT GO check plug gauge screwed by hand, gauges or ring gauges. For checking the GO limit of
without using excessive force, may enter the new solid non-rigid workpieces preference should be given to the
NOT GO screw ring gauge at both ends but not more use of a ring gauge (Taylor principle); the calliper gauges
than one turn of thread’). are recommended only if the workpieces have been
manufactured by methods which do not involve the
risk of errors of circularity.
7.1.11 Setting plug for adjustable NOT GO screw ring
gauge
c) The GO plain calliper gauge shall pass over the work-
piece thread under its own weight or under an agreed
a) The setting plug which contains two successive
load; the NOT GO plain calliper gauge shall not pass over
portions, one with complete flanks and the other with
the thread. Otherwise the workpiece thread does not
truncated flanks, is used to set the adjustable NOT GO
comply with the specifications.
screw ring gauge to the specified pitch diameter.
It is not essential to use a double length setting plug if
7.2 Gauges for workpiece internal threads
the NOT GO screw ring gauge is checked with a NOT
J
GO screw check plug described in 7.1.10 after it has
7.2.1 GO screw plug gauge
been adjusted.
a) The GO screw plug gauge checks the virtual size of
b) The NOT GO screw ring gauge is set on the portion
the internal thread on the GO side (gauging the virtual
of the setting plug with complete flanks.
pitch diameter). This is effected by checking the mini-
c) The portion with complete flanks screwed by hand
mum limit of the pitch diameter, taking into account
without using excessive force, shall pass through the
pitch errors, errors in the flank angles, helix variations
screw ring gauge.
and deviations of form (departures from roundness and
lack of straightness of the thread axis over the gauge
When the portion with truncated flanks of the setting
length) which produce an apparent reduction of the
plug is screwed through the ring gauge, no perceptible
pitch diameter of the workpiece (virtual pitch diameter).
clearance is permissible between the plug and the ring.
it checks the minimum limit of the major
In addition
If there is a clearance the ring gauge shall be lapped and
diameter and also whether the length of straight flank is
adjusted to correct form and size.
sufficient, i.e. that the rounding at the root of the
profile does not encroach too far upon the flank of the
7.1 .I2 Wear check plug for solid or adjustable NOT GO
thread. It does not check the minor diameter of the
screw ring gauge
internal thread.
a) The wear check plug checks whether the pitch
Checking with the GO screw plug gauges is essentially
diameter of the NOT GO screw ring gauge has exceeded
in accordance with the Taylor principle.
the wear limit. It embodies the pitch diameter of the
NOT GO screw ring gauge at the prescribed limit of
b) It is recommended that the GO screw plug gauge
wear.
be checked regularly for wear.
If a NOT GO check plug for the NOT GO screw ring
The admissible wear of the GO screw plug gauge is found
gauge is provided, the wear check plug may be dispensed
by measuring.
with.
Instead of measuring, a wear check gauge (calliper gauge)
c) The wear check plug screwed by hand, without using with its setting plug may be used. However
...

NORME INTERNATIONALE 1502
~~ ~~ ~~
INTERNATIONAL ORGANIZATION FOR STANDARDlZATION*ME)KAYHAPOAHAR OPrAHW3AUMR no CTAHAAPTH3AUHH«)RGANlSATlON INTERNATIONALE DE NORMALISATION
-'
Filetages métriques IS0 pour usages généraux - Vérification
à limites
par calibres
IS0 general purpose metric screw threads - Gauging
Première édition - 1978-07-15
LL
-
CDU 621.882.082 Réf. no : IS0 1502-1978 (F)
R
!2
Doscriptourn : filetage, filetage ISO, calibre, calibre fileté, calibre tampon, contrôle, dimension, tolérance de dimension, calcul, formule.
N
-
Prix basé sur 22 pages

---------------------- Page: 1 ----------------------
AVANT-PROPOS
L'ISO (Organisation internationale de normalisation) est une fédération mondiale
d'organismes nationaux de normalisation (comités membres de I'ISO). L'élaboration
des Normes internationales est confiée aux comités techniques de I'ISO. Chaque
comité membre intéressé par une étude a le droit de faire partie du comité technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I'ISO, participent également aux travaux.
Les projets de Normes internationales adoptés par les comités techniques sont
soumis aux comités membres pour approbation, avant leur acceptation comme
Normes internationales par le Conseil de I'ISO.
La Norme internationale IS0 1502 a été élaborée par le comité technique lSO/TC 1,
Filetages. Elle fut soumise directement au Conseil de I'ISO, conformément au
paragraphe 6.13.1 des Directives pour les travaux techniques de I'ISO. Elle annule
et remplace la Recommandation ISO/R 1502-1970 qui avait été approuvée par les
comités membres des pays suivants :
Afrique du Sud, Rép. d' France Pologne
Allemagne Hongrie Portugal
Autriche Inde Roumanie
Belgique Israël Royaume-Uni
Chili Italie Suède
Corée, Rép. de Japon Tchécoslovaquie
Danemark Norvège Thaïlande
Egypte, Rép. arabe d' Pays-Bas Turquie
Espagne Pérou
Les comités membres des pays suivants l'avaient désapprouvée pour des raisons
techniques :
Australie* Suisse"
U.R.S.S.*
Canada
Nouvelle-Zélande* U.S.A.
* Par la suite, ces comités membres ont fait savoir qu'ils approuvaient la Norme internationaie
IS0 1502.
Q organisation internationale de normalisation, 1978 0
Imprimé en Suisse
II

---------------------- Page: 2 ----------------------
SOMMAI RE Page
1 Objet et domaine d'application . 1
2 Références . 1
3 Typesdecalibres . 1
3.1 Calibres pour filetages extérieurs de pièces et leurs tampons rapporteurs et
tampons de référence . 1
3.2 Calibres pour filetages intérieurs de pièces . 1
4 Vérification de pièces . 2
4.1 Vérification de filetages extérieurs . 2
4.2 Vérification de filetages intérieurs . 2
4.3 Réception par calibrage . 2
5 Température de référence . 3
6 Symboles et explications . 3
7 Fonction, vérification et emploi des calibres . 4
7.1
Calibres pour filetages extérieurs de pièces et leurs tampons rapporteurs et
tampons de référence . 4
7.2 Calibres pour filetages intérieurs de pièces . 6
8
Zones de tolérances pour le diamètre sur flancs des calibres filetés . 7
9 Zones de tolérances pour calibres lisses . 10
10
Profils des filetages de calibres . 11
10.1 Profils avec flancs complets . 11
10.2 Profils avec flancs raccourcis . 14
11 Caractéristiques générales des calibres filetés . 16
11.1 Calibres pour filetages extérieurs de pièces . 16
11.2 Calibres pour filetages intérieurs de pièces . 17
11.3
Entrée du filetage . 17
12 Tolérances et usure admissible pour les calibres . 18
13 Formules pour le calcul des limites de calibres . 20
13.1 Calibres filetés pour filetages extérieurs . 20
13.2 Calibres lisses pour le diamètre extérieur . 22
13.3 Calibres filetés pour filetages intérieurs . 22
13.4
Calibres lisses pour le diamètre intérieur . 22
...
Ill

---------------------- Page: 3 ----------------------
IS0 1502-1978 (F)
NORME INTERNATIONALE
Filetages métriques IS0 pour usages généraux - Vérification
par calibres à limites
1 OBJET ET DOMAINE D'APPLICATION 3 TYPES DE CALIBRES
La présente Norme internationale spécifie les caractéris
La présente Norme internationale fournit les indications
tiques essentielles des types de calibres' ) mentionnés en 3.1
nécessaires à la fabrication et à l'emploi de calibres pour le
et 3.2, qui sont recommandés pour contrôler les filetages
contrôle des filetages métriques IS0 pour usages généraux
à I'ISO 68 et à I'ISO 261. extérieurs et intérieurs de pièces et pour l'ajustage et le
conformes
contrôle de certains calibres filetés.
D'autres méthodes de vérification peuvent naturellement
I être adoptées, par exemple le mesurage au moyen d'appa-
3.1 Calibres pour filetages extérieurs de pièces et leurs
reils de mesure à lecture. La vérification au moyen des
tampons rapporteurs et tampons de référence
calibres recommandés dans la présente Norme internationale
est cependant toujours déterminante. - Bague filetée ENTRE fixe
La présente Norme internationale fournit les moyens - Baclue filetée ENTRE réglable
-
propres à différencier les filetages restant dans les limites
- Tampons rapporteurs ENTRE et N'ENTRE PAS
de tolérances de ceux qui se situent hors de ces limites.
pour baque filetée ENTRE fixe, neuve
-
Dans le but d'assurer l'interchangeabilité des filetages de
- Tampon de référence pour bague filetée ENTRE
oièces et Dour éviter tout litiae entre le fabricant et I'ache-
réglable
teur, il convient d'observer les principes suivants :
- Témoin d'usure pour bague filetée ENTRE fixe OL
a) le fabricant ne doit fournir aucune pièce dont les
réglable
dimensions effectives de filetage (par exemple le dia-
mètre sur flancs et le diamètre virtuel sur flancs) se
- Calibre-mâchoires fileté ENTRE
trouvent hors des limites fixées;
- Tampon de référence pour calibre-mâchoires filet4
b) l'acheteur ne doit refuser aucune pièce dont les
ENTRE
dimensions effectives de filetage (par exemple le dia-
- Calibre-mâchoires fileté N'ENTRE PAS
sur flancs et le diamètre virtuel sur flancs) se
mètre
trouvent à l'intérieur des limites fixées.
- Tampon de référence pour calibre-mâchoires filet(
N'ENTRE PAS
En vue de respecter ces deux principes, la présente Norme
'-2
internationale spécifie les types et les dimensions de calibres
- Bague filetée N'ENTRE PAS fixe
nécessaires à la vérification des filetages, les conditions
d'utilisation de ces calibres et les règles applicables à
- Bague filetée N'ENTRE PAS réglable
l'inspection des filetages de pièces.
- Tampons rapporteurs ENTRE et N'ENTRE PA:
pour bague filetée N'ENTRE PAS fixe, neuve
- Tampon de référence pour bague filetée N'ENTRE
2 RÉFÉRENCES
PAS réglable
IS0 1, Température normale de référence des mesures
industrielles de longueur. - Témoin d'usure pour bague filetée N'ENTRE
PAS fixe ou réglable
IS0 68, Filetages IS0 pour usages généraux - Profil de
base. - Calibres lisses pour diamètre extérieur (bague OL
cal ibre-mâchoires)
IS0 261, Filetages métriques IS0 pour usages généraux -
Vue d'ensemble.
3.2 Calibres pour filetages intérieurs de pièces
IS0 96511, Filetages métriques IS0 pour usages généraux -
- Tampon fileté ENTRE
Tolérances - Principes et données fondamentales.
- Tampon fileté N'ENTRE PAS
ISO/R 1938, Systèmes IS0 de tolérances et d'ajuste-
- Calibres lisses pour diamètre intérieur (tampons)
ments - Deuxième partie : Vérification des pièces lisses.
Les calibres ENTRE et N'ENTRE PAS peuvent être combinés.
1)
1

---------------------- Page: 4 ----------------------
IS0 1502-1978 (F)
4 VÉRIFICATION DE PIÈCES 4.3 Réception par calibrage
II n'est pas nécessaire d'utiliser, à l'atelier ou au départe-
4.3.1 Par le fabricant
ment de contrôle, tous les calibres mentionnés au chapitre 3.
Le département de contrôle qui vérifie les filetages usinés
Toutefois, pour la vérification des limites (contrôle du res-
dans l'atelier peut, en principe, utiliser des calibres de même
pect des tolérances), il est nécessaire d'effectuer une vérifi-
type que ceux de l'atelier.
cation ENTRE avec l'un des calibres ENTRE et une vérifi-
cation N'ENTRE PAS avec l'un des calibres N'ENTRE
Des litiges entre la fabrication et le contrôle peuvent
PAS, mentionnés ci-dessus.
s'élever lors de la vérification, au moyen de calibres, de
pièces situées aux limites de tolérances.
4.1 Vérification de filetages extérieurs
En cas de litige, il est recommandé d'accepter la pièce si
Une bague filetée ENTRE, fixe ou réglable, doit, de préfé-
elle est trouvée satisfaisante par un calibre quelconque du
rence, être utilisée pour vérifier un filetage extérieur.
type adéquat, reconnu conforme aux spécifications de la
présente Norme internationale (compte tenu de l'usure
En vue de réduire le temps consacré au contrôle ou lorsque
adm issi ble) .
la bague filetée ENTRE ne peut être utilisée, il est possible
de se servir d'un calibre-mâchoires fileté ENTRE.
En cas de litige, la vérification des bagues filetées au moyen
des tampons rapporteurs est déterminante, à défaut
il est recommandé de compléter une vérification
Toutefois,
4
y relatif entre le fabricant et l'acheteur.
d'accord
effectuée au moyen de calibres-mâchoires filetés ENTRE
NOTE - Les possibilités de litiges peuvent être réduites au
par un prélèvement d'échantillons au hasard au moyen de la
minimum par une répartition des calibres telle que ceux de la fabri-
bague filetée ENTRE, afin que, lorsqu'un grand nombre de
cation permettent une vérification plus serrée que ceux utilisés au
pièces sont contrôlées au moyen d'un calibre-mâchoires
contrôle. Généralement, ce but peut être atteint en délivrant à la
fileté ENTRE, un certain pourcentage soit soumis à un
fabrication des calibres ENTRE neufs ou seulement légèrement
contrôle additionel au moyen d'une bague filetée ENTRE; usés et des calibres N'ENTRE PAS peu usés. Le contrôle doit utiliser
ENTRE s'approchant de la condition du maximum
des calibres
cette précaution permettra de mieux assurer I'interchan-
d'usure admissible et des calibres N'ENTRE PAS à l'état neuf.
geabilité des filetages de pièces.
4.3.2 Par l'acheteur
Le calibre-mâchoires fileté ENTRE ne doit pas être utilisé
si le procédé de fabrication entraîne, dans le filetage de la
II existe trois possibilitésd'inspection des filetages de pièces,
pièce, des imperfections que ce calibre ne peut déceler avec
pour le compte de l'acheteur, par un inspecteur n'apparte-
certitude, par exemple : irrégularités locales de pas pour les
nant pas à l'établissement de fabrication :
filetages fraisés ou bavures à l'entrée du filetage. De plus, le
calibre-mâchoires fileté ENTRE ne convient pas à la vérifi-
a) Pour la vérification des filetages de pièces, I'inspec-
cation de pièces non rigides, par exemple a paroi mince, teur utilise les calibres du fabricant.
susceptibles d'être déformées par ce calibre. Dans de tels
Dans ce cas, l'inspecteur peut vérifier l'exactitude des
cas, la vérification doit s'effectuer au moyen d'une bague
calibres employés au moyen de tampons rapporteurs
filetée ENTRE.
et de tampons de référence appartenant soit à l'établis-
Le calibre-mâchoires fileté N'ENTRE PAS est utilisé
sement de fabrication (fabricant), soit à l'inspecteur
pour vérifier le diamètre mesuré sur flancs du filetage
(acheteur) ou, en ce qui concerne les tampons filetés,
extérieur sur le côté N'ENTRE PAS.
par mesurage direct.
b) L'inspecteur utilise ses propres calibres pour la
La bague filetée N'ENTRE PAS, fixe ou réglable, ne doit
vérification des filetages de pièces.
être utilisée que pour des pièces non rigides, par exemple à
paroi mince, susceptibles d'être déformées lors de la vérifi-
En cas de litige, il est recommandé d'accepter la pièce
cation au moyen d'un calibre-mâchoires fileté N'ENTRE
si elle est trouvée satisfaisante par un calibre quelconque
PAS.
du type adéquat, reconnu conforme aux spécifications
de la présente Norme internationale (compte tenu de
Pour la vérification du diamètre extérieur du filetage
l'usure admissible).
extérieur de la pièce, il convient d'utiliser des calibres
lisses ENTRE et N'ENTRE PAS. La forme et la rigidité
c) L'inspecteur utilise ses propres calibres d'inspection
de la pièce déterminent le choix entre le calibre-mâchoires
pour la vérification des filetages de pièces.
ou la bague. Des bagues doivent être utilisées pour les pièces
La position de la zone de tolérances pour ces calibres
non rigides.
doit donner toute assurance que le client ne refuse
aucune pièce dont les dimensions effectives de filetage
4.2 Vérification de filetages intérieurs
se trouvent dans les limites spécifiées pour la pièce.
Pour la vérification du filetage intérieur de la pièce, les
La présente Norme internationale ne spécifie pas les calibres
tampons filetés ENTRE et N'ENTRE PAS doivent être
devant être utilisés par l'inspecteur; elle recommande seule-
utilisés.
ment que l'acheteur communique au fabricant lors de la
Pour la vérification du diamètre intérieur du filetage inté- commande, quel procédé sera adopté pour l'inspection des
rieur de la pièce, les tampons lisses ENTRE et N'ENTRE filetages de pièces. Des calibres usés ne doivent pas être
PAS doivent être utilisés. utilisés pour le contrôle par échantillon.
2

---------------------- Page: 5 ----------------------
IS0 1502-1978 (F)
ou pièces en laiton et calibres en acier ou en carbure), la
5 TEMPERATURE DE R ÉFÉRENCE
température des pièces et des calibres doit être très proche
Les dimensions des calibres et des pièces doivent se référer
de 20 f 2 OC lors du contrôle. si tel n'est pas le cas, il est
à une température de 20 OC, conformément à I'ISO 1.
alors nécessaire de tenir compte de la différence de dilata-
thermique de la pièce et du calibre.
Si les pièces et les calibres ont le même coefficient de dila-
tation (par exemple, pièces en acier et calibres en acier),
la température de vérification peut sans danger s'écarter
de 20 OC, à condition que les pièces et les calibres utilisés
6 SYMBOLES ET EXPLICATIONS
aient à peu près la même température.
Les symboles mentionnés dans la présente Norme inter-
Si les pièces et les calibres ont un coefficient de dilatation
nationale sont énumérés dans la liste ci-dessous.
différent (par exemple, pièces en acier et calibres en carbure
Symboles et explications
Symbole Explication
Tolérance sur l'inclinaison de flanc des profils
Largeur de la piqûre au diamètre extérieur du
6,
avec flancs complets
profil
Largeur de la piqûre au diamètre intérieur du
62
avec flancs raccourcis
profil avec flancs complets
~
Tolérance pour le diamètre sur flancs de tampons
Largeur de la piqûre au diamètre extérieur et
rapporteurs ENTRE et N'ENTRE PAS, et de
intérieur, respectivement du profil avec flancs
témoins d'usure et tampons de référence
I
raccourcis
Tolérance pour le diamètre extérieur du filetage
'd
Diamètre extérieur de base du filetage de la pièce
Diamètre intérieur de base du filetage intérieur
'd2
de la pièce
extérieur de la pièce
Diamètre sur flancs de base du filetage de la pièce
Tolérance pour le diamètre intérieur du filetage
intérieur de la pièce
es Écart fondamental du filetage extérieur (pour la
position de tolérance h, l'écart fondamental es est
Tolérance pour le diamètre sur flancs du filetage
~ '02 I
égal à zéro) intérieur de la pièce
EI Écart fondamental du filetage intérieur (pour la Tolérance pour le pas du filetage de calibre
Tp
position de tolérance H, l'écart fondamental .€I
Tolérance pour le diamètre sur flancs de tampons
est égal à zéro)
TpL
filetés ENTRE et N'ENTRE PAS
Fl
Pour les profils avec flancs raccourcis, distance
Tolérance pour le diamètre sur flancs de bagues
T,
radiale entre la ligne primitive et la fin de la
filetées ENTRE et N'ENTRE PAS
partie droite du flanc en direction du sommet
Valeur moyenne représentant l'usure admissible du
W,,
tampon fileté ENTRE et de la bague filetée ENTRl
Pour les profils avec flancs raccourcis, distance
F2
radiale entre la ligne primitive et la fin de la
Valeur moyenne représentant l'usure admissible du
WNG
partie droite du flanc en direction du fond
tampon fileté N'ENTRE PAS et de la bague filetée
N'ENTRE PAS
H Hauteur du triangle du profil du filetage
Distance du centre de la zone de tolérance Hi du
=1
Tolérance pour tampons lisses
tampon ENTRE à la limite inférieure du diamètre
Hl
intérieur de la pièce
Tolérance pour calibres-mâchoires lisses et bagues
H2
lisses
Distance du centre de la zone de tolérance H2 du
z2
calibre-mâchoires ENTRE, ou de la bague ENTRE,
Tolérance pour calibres de référence pour calibres-
à la limite supérieure du diamètre extérieur de la
mâchoires lisses pièce
Distance entre le centre des zones de tolérance T, Distance du centre de la zone de tolérance TpL du
tampon fileté ENTRE à la cots limite inférieure du
de la bague filetée et TCP du tampon rapporteur
-zpL I filetage de la pièce
ENTRE
Distance du centre de la zone de tolérance T, de
z,
la bague filetée ENTRE à la cote limite supérieure
du filetage de la pièce
Déport de la piqûre avec flancs raccourcis
3

---------------------- Page: 6 ----------------------
IS0 1502-1978 (F)
7 FONCTION, VERIFICATION ET EMPLOI DES c) Le rapporteur ENTRE doit pouvoir, sans forcer
CALIBRES particulièrement, se visser à la main à travers la bague
filetée ENTRE fixe, neuve.
Dans ce chapitre, les désignations des paragraphes ont les
Le rapporteur N'ENTRE PAS ne doit pas pouvoir, sans
significations suivantes :
forcer particulièrement, se visser à la main ni d'un côté
a) = fonction; b) = vérification; c) =emploi.
la bague filetée ENTRE fixe, neuve,
ni de l'autre de
mais pas de plus d'un seul filet').
7.1.3 Tampon de référence pour bague filetée ENTRE
7.1 Calibres pour filetages extérieurs de pieces et leurs
réglable
tampons rapporteurs et tampons de référence
a) Le tampon de référence contient deux parties SUC-
7.1 .I Bague filetée ENTRE fixe ou réglable
cessives, l'une avec flancs complets et l'autre avec flancs
raccourcis; il est utilisé pour l'ajustage de la bague filetée
a) La bague filetée ENTRE vérifie la dimension
ENTRE réglable au diamètre sur flancs prescrit.
virtuelle du filetage extérieur du côté ENTRE (vérifi-
cation du diamètre virtuel sur flancs), c'est-àdire
II n'est pas essentiel d'utiliser un tampon de référence
qu'elle contrôle la dimension maximale de matière du
avec une longueur double si la bague filetée ENTRE est
diamètre sur flancs, y compris les écarts de forme
vérifiée avec un tampon rapporteur N'ENTRE PAS (voir
W
(défauts de circularité et de rectitude de l'axe de filetage
7.1.2) après avoir été ajustée.
sur la longueur du calibre) et les erreurs de pas, d'hélice
et d'inclinaison de flanc. Ces erreurs provoquent un agran- b) Le réglage de la bague filetée ENTRE se fait sur la
partie du tampon de référence ayant des flancs complets.
dissement apparent du diamètre sur flancs (diamètre
virtuel sur flancs) de la pièce. Cette bague vérifie, de
c) La partie avec flancs complets doit pouvoir, sans
plus, si la partie droite de flanc est assez longue,
forcer particulièrement, se visser à la main à travers la
c'est-à dire si l'arrondi à fond de filet ne pénètre pas trop
bague filetée ENTRE.
avant sur le flanc du profil. Cette bague ne vérifie pas le
diamètre extérieur du filetage extérieur.
Lorsque la partie du tampon de référence présentant des
flancs raccourcis est vissée dans la bague filetée, aucun
La bague filetée ENTRE vérifie essentiellement selon le
jeu perceptible ne doit exister entre le tampon de réfé-
principe de Taylor.
rence et la bague filetée. En cas de jeu, la bague filetée
b) La bague filetée ENTRE fixe, fabriquée selon les doit être rodée et ajustée à une forme et une dimension
dimensions prescrites, doit être vérifiée par les tampons correctes.
et N'ENTRE PAS et
rapporteurs filetés ENTRE
contrôlée régulièrement par le témoin d'usure.
7.1.4 Témoin d'usure pour bague filetée ENTRE fixe
ou réglable
Si le tampon rapporteur N'ENTRE PAS n'est pas utilisé,
d'autres mesures doivent être prises pour s'assurer que la
a) Ce témoin d'usure sert à vérifier si le diamètre sur
dimension maximale du diamètre sur flancs de la bague
la -
flancs des bagues filetées ENTRE n'a pas dépassé
filetée ENTRE n'est pas dépassée.
limite d'usure. II représente donc le diamètre sur flancs
de la bague filetée ENTRE à la limite d'usure prescrite.
La bague filetée ENTRE réglable doit être ajustée au
moyen du tampon de référence et doit être contrôlée
c) Le témoin d'usure ne doit pas pouvoir, sans forcer
régulièrement par le témoin d'usure.
particulièrement, se visser à la main ni d'un côté ni de
l'autre de la bague filetée ENTRE, de plus d'un seul
c) La bague filetée ENTRE doit pouvoir, sans forcer
filet').
particulièrement, se visser à la main sur toute la longueur
du filetage de la pièce. Si tel n'est pas le cas, le filetage Si elle se laisse visser de plus d'un seul filet, la bague
de la pièce ne répond pas aux prescriptions. filetée ENTRE ne répond plus aux prescriptions.
7.1.5 Calibre-mâchoires fileté ENTRE
7.1.2 Tampons rapporteurs pour bague filetée ENTRE
a) Ce calibre vérifie la dimension maximale du diamètre
fixe, neuve
sur flancs dans un plan axial, où des erreurs de pas et
a) Ces tampons rapporteurs (ENTRE et N'ENTRE PAS)
d'inclinaison de flancs de la pièce provoquent un agran-
sont utilisés pour la vérification des dimensions limites
dissement apparent de son diamètre sur flancs. De plus,
du diamètre sur flancs de la bague filetée ENTRE fixe,
il vérifie si la partie droite du flanc est assez longue,
neuve. En outre, le tampon rapporteur ENTRE vérifie
c'est-à-dire si l'arrondi à fond de filet ne pénètre pas trop
la limite ENTRE du profil total de la bague filetée
avant dans le flanc du profil. Le diamètre extérieur du
ENTRE fixe, neuve, appropriée.
filetage extérieur n'est cependant pas vérifié.
1) Le nombre de filets est déterminé lors du dévissage du tampon.
4

---------------------- Page: 7 ----------------------
IS0 1502-1978 (F)
7.1.8 Tampon de référence pour calibre-mâchoires fileté
En ce qui concerne le diamètre virtuel sur flancs, le
N'ENTRE PAS
calibre-mâchoires fileté ENTRE s'éloigne considérable-
ment du principe de Taylor (les erreurs de pas
a) Ce tampon de référence sert à l'ajustage des touches
périodiques et les erreurs de forme telles que l'écart de
du calibre-mâchoires N'ENTRE PAS.
circularité ne sont pas décelées).
c) Le calibre-mâchoires fileté N'ENTRE PAS doit
b) Le calibre-mâchoires fileté ENTRE doit être ajusté
passer sur le tampon de référence sous l'action de son
à l'aide du tampon de référence spécifié.
propre poids ou d'une charge déterminée. Si tel n'est
c) En général, les filetages de pièces sont vérifiés par pas le cas, ou s'il y a du jeu, les touches du calibre-
calibre-mâchoires fileté ENTRE, sous son propre poids mâchoires fileté N'ENTRE PAS doivent être réajustées.
ou sous une charge d'emploi indiquée, pour corres-
Une fois placé sur le tampon de référence, le calibre-
pondre à la méthode d'ajustement du calibre.
mâchoires fileté N'ENTRE PAS peut recevoir un léger
mouvement d'oscillation circulaire.
Le calibre-mâchoires fileté ENTRE doit accepter le file-
tage de pièce au moins en trois endroits également
répartis sur la circonférence du filetage. Si tel n'est pas le
7.1.9 Bague filetée N'ENTRE PAS fixe ou réglable
le filetage de pièce ne répond pas aux prescriptions.
cas,
a) La bague filetée N'ENTRE PAS est prévue pour
Une fois posé sur la pièce, le calibre-mâchoires fileté
vérifier si le diamètre sur flancs effectif dépasse la
k
ENTRE peut recevoir un léger mouvement d'oscillation
dimension minimale spécifiée. La vérification avec la
circulaire en vue de réduire les effets de frottement.
bague filetée N'ENTRE PAS ne correspond pas au prin-
cipe de Taylor lors de la vérification de pièces rigides.
En cas de litige, la vérification avec la bague filetée
En cas de pièces non rigides, l'abandon du principe de
ENTRE, de préférence du type fixe, doit être déter-
Taylor revêt moins d'importance en raison de la flexi-
minante.
bilité des pièces.
b) La bague filetée N'ENTRE PAS fixe, fabriquée selon
7.1.6 Tampon de référence pour calibre-mâchoires fileté
les dimensions prescriptes, doit être vérifiée par les
ENTRE
tampons rapporteurs ENTRE et N'ENTRE PAS et
contrôlée régulièrement par le témoin d'usure.
a) Ce tampon de référence sert à l'ajustage des touches
du calibre-mâchoires ENTRE.
Si le tampon rapporteur N'ENTRE PAS n'est pas utilisé,
c) Le calibre-mâchoires fileté ENTRE doit passer sur d'autres mesures doivent être prises pour s'assurer que la
le tampon de référence sous l'action de son propre limite maximale du diamètre sur flancs de la bague
poids ou d'une charge d'emploi déterminée. Si tel n'est filetée neuve N'ENTRE PAS n'est pas dépassée.
y a du jeu, les touches du calibre-
pas le cas, ou s'il
La bague filetée N'ENTRE PAS réglable doit être ajustée
mâchoires fileté ENTRE doivent être réajustées.
à l'aide du tampon de référence et contrôlée régulière-
Le calibre-mâchoires fileté ENTRE peut recevoir un ment par le témoin d'usure.
léger mouvement d'oscillation une fois placé sur le
c) La bague filetée N'ENTRE PAS ne doit pas pouvoir,
tampon de référence.
sans forcer particulièrement, se visser à la main sur le
filetage de la pièce ni d'un côté ni de l'autre de plus de
7.1.7 Calibre-mâchoires fileté N'ENTRE PAS
deux filets'). Si elle peut être vissée sur la pièce de plus
de deux filets, le filetage ne répond pas aux pres-
a) Ce calibre vérifie la dimension minimale du diamètre
criptions. La bague filetée N'ENTRE PAS ne doit pas
sur flancs. II agit essentiellement suivant le principe de
passer complètement sur une pièce ayant une longueur
Tay I or.
de filetage de trois filets ou moins.
b) Le calibre-mâchoires fileté N'ENTRE PAS doit être
ajusté à l'aide du tampon de référence spécifié.
7.1.10 Tampons rapporteurs pour bague filetée N'ENTRE
PAS fixe, neuve
c) Le calibre-mâchoires fileté N'ENTRE PAS ne doit
pas passer sur la pièce, exception faite des deux premiers
a) Les tampons rapporteurs (ENTRE et N'ENTRE PAS)
la pièce. Lors de la vérification, il faut respecter
filets de
sont utilisés pour la vérification des dimensions limites
les mêmes conditions que pour l'ajustage au moyen du
du diamètre sur flancs de la bague filetée N'ENTRE PAS
tampon de référence. Elle doit être effectuée au moins
fixe, neuve. Le rapporteur ENTRE vérifie que le dia-
en trois endroits, également répartis sur la circonfé-
mètre de dégagement de la bague filetée N'ENTRE PAS
rence.
fixe, neuve, n'est pas trop faible.
Si le calibre correspond à la figure lob), chaque vérifica- Si le témoin d'usure est prévu pour la bague filetée
le calibre d'un pas à PAS, le tampon rapporteur N'ENTRE PAS
tion doit être répétée en déplaçant N'ENTRE
l'autre. peut être supprimé.
1) Le nombre de filets est déterminé lors du dévissage de la bague filetée.
5

---------------------- Page: 8 ----------------------
IS0 1502-1978 (F)
c) Le rapporteur ENTRE doit pouvoir, sans forcer
7.1 .13 Calibres lisses pour le diamètre extérieur
particulièrement, se visser à la main à travers la bague
a) Le diamètre extérieur du filetage de la pièce est
filetée N'ENTRE PAS fixe, neuve, correspondante.
vérifié par des calibres-mâchoires lisses ENTRE et
Le tampon rapporteur N'ENTRE PAS ne doit pas N'ENTRE PAS, ou par des bagues lisses ENTRE et
pouvoir, sans forcer particulièrement, se visser à la main
N'ENTRE PAS. Pour vérifier la limite ENTRE de pièces
ni d'un côté ni de l'autre de la bague filetée N'ENTRE
non rigides, la préférence doit être accordée .à la bague
PAS fixe, neuve, de plus d'un seul filet').
lisse (principe de Taylor); les calibres-mâchoires ne
sont recommandés que si les pièces ont été fabriquées
selon des procédés n'entraînant aucun risque d'erreur
7.1.11 Tampon de référence pour bague filetée N'ENTRE
de circularité.
PAS réglable
c) Le calibre-mâchoires lisse ENTRE doit pouvoir
a) Le tampon de référence contient deux parties suc-
passer sur le filetage de la pièce SOUS l'effet de son propre
cessives, l'une avec flancs complets et l'autre avec flancs
poids ou d'une charge convenue; le calibre-mâchoires
raccourcis; il est utilisé pour l'ajustage de la bague filetée
lisse N'ENTRE PAS ne doit pas passer sur le filetage.
N'ENTRE PAS réglable au diamètre sur flancs prescrit.
Sinon, le filetage de la pièce ne répond pas aux prescrip-
II n'est pas essentiel d'utiliser un tampon de référence tions.
avec une longueur double si la bague filetée N'ENTRE
W
PAS est vérifiée avec un tampon rapporteur N'ENTRE
PAS décrit en 7.1.10, après avoir été ajustée.
7.2 Calibres pour filetages intérieurs de pieces
b) Le réglage de la bague filetée N'ENTRE PAS se fait
7.2.1 Tampon fileté ENTRE
sur la partie du tampon de référence ayant des flancs
complets.
a) Le t
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.