Abstract

This document specifies the properties of the piping system and its components made from glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester (UP) resin. It is suited for all types of water supply, drainage and sewerage with or without pressure. Types of water supply include, but are not limited to, raw water, irrigation, cooling water, potable water, salt water, sea water, penstocks in power plants, processing plants and other water-based applications. This document is applicable to GRP-UP piping systems, with flexible joints, intended to be installed using jacking techniques. It specifies the characteristics of pipes made from GRP-UP, with or without aggregates or fillers. It also specifies the test parameters for the test methods referred to in this document. This document is applicable to circular pipes and joints with a size range from DN 100 to DN 4 000 at normal service conditions. This document covers requirements to demonstrate the adequacy of the design of the joint and specifies type test performance requirements for the joints as a function of the declared nominal pressure rating of the pipeline system and the required joint deflection capability of the system. The determination of longitudinal compressive properties of a pipe are given in Annex A and Annex B. The procedure for the calculation of the design jacking load on a GRP (UP) pipe is given in Annex C. Requirements for GRP-fittings, used between pipe systems covered by this document, are given in ISO 23856.

Status
Published
Publication Date
19-Nov-2026
Current Stage
6060 - International Standard published
Start Date
20-Nov-2026
Completion Date
20-Nov-2026

Buy Documents

Standard

ISO 25780:2026 - Plastics piping systems for pressure and non-pressure water supply, drainage or sewerage — Glass-reinforced thermosetting plastics (GRP) systems based on unsaturated polyester (UP) resin — Pipes with flexible joints intended to be installed using jacking techniques

Release Date:20-Nov-2026
English language (43 pages)
sale 15% off
Preview
sale 15% off
Preview

ISO 25780 is an International Standard published by ISO for glass-reinforced thermosetting plastics (GRP) piping systems based on unsaturated polyester (UP) resin. It specifies pipe and joint properties, test parameters, and joint performance requirements for pressure and non-pressure water supply, drainage, and sewerage systems that are installed using jacking techniques.

Engineers, buyers, manufacturers, and quality teams use ISO 25780 to define the pipe dimensions, materials, load ratings, testing, marking, and conformity checks for these trenchless pipeline systems.

What does ISO 25780 specify?

ISO 25780 specifies GRP-UP pipes with flexible joints for water supply, irrigation, drainage, and sewerage, with or without pressure. It covers circular pipes and joints from DN 100 to DN 4000 intended for conveyance of water or sewage at temperatures up to 50 °C under normal service conditions.

The document also gives the test parameters for the methods it cites, and it sets requirements for joint design and joint type test performance as a function of the declared nominal pressure rating and the required joint deflection capability.

It is organized into:

  • Clause 1 Scope
  • Clause 2 Normative references
  • Clause 3 Terms, definitions, symbols and abbreviated terms
  • Clause 4 Requirements
  • Clause 5 Pipes
  • Clause 6 Joints
  • Normative Annexes A to C
AnnexWhat it covers
Annex ALongitudinal compressive properties of a pipe using prism test pieces cut from a pipe ring
Annex BLongitudinal compressive properties of pipes using spool test pieces
Annex CCalculation procedure for the design jacking load on a GRP (UP) pipe

What are the key requirements of ISO 25780?

ISO 25780 focuses on the declared pipe ratings, the pipe and joint construction, and the loads a jacked pipeline must withstand. The most important practical point is that the manufacturer has to declare the design data used for installation and then verify it by testing.

Pipe design, dimensions and materials

  • ISO 25780 requires the manufacturer to declare the outside diameter and its tolerances, the maximum spigot inside diameter, and the design jacking load for a closed joint. In practice, these values define what can be ordered, marked, and checked on delivery.
  • ISO 25780 sets a minimum nominal stiffness of SN 20 000 for jacking applications, and SN 30 000 for curved installations, uncontrolled installations, or installation lengths above 50 m. This is meant to limit spigot failures caused by lateral forces during steering and jacking.
  • ISO 25780 allows nominal pressure values in the stated table, with PN 1 treated as non-pressure components. Where other pressure ratings are agreed, the marking changes to PNv.
  • ISO 25780 limits the pipe materials to the stated glass reinforcement types and unsaturated thermosetting polyester resin, with a thermoplastics liner or other thermosetting liner where used. The resin used in the structural layer must have a deflection temperature of at least 70 °C when tested as specified, and aggregates or fillers must not exceed 2.5 mm.

Test conditions and long-term performance

  • ISO 25780 sets reference test conditions at 23 °C ± 5 °C, with type tests at the service temperature for service temperatures above 35 °C up to 50 °C. This matters because long-term properties can change with temperature, so the test data must match the intended use.
  • ISO 25780 requires tap water with pH 7 ± 2 for the relevant tests, and it requires preconditioning in dispute cases. It also points to ISO 3126 for dimensional measurement.
  • ISO 25780 requires initial ring stiffness to be determined by ISO 7685 and to be at least the declared nominal stiffness, and it requires long-term creep stiffness to be determined or derived using ISO 10468 or an equivalent approved approach. For a buyer, this shows how the pipe is expected to behave under burial and deflection over time.
  • ISO 25780 requires resistance to initial failure in a deflected condition by ISO 10466, and resistance to strain corrosion for septic sewers or corrosive effluents by ISO 10952. These checks matter where the pipe may be bent, loaded, or exposed to aggressive fluids.

Joints, loads and conformity

  • ISO 25780 requires flexible joints with elastomeric seals, and the manufacturer has to declare the maximum allowable draw, total draw, and angular deflection for each joint design. The joint must withstand the installation and service loads without visible damage or leakage.
  • ISO 25780 requires joint performance tests using ISO 8639, including pressure and deformation conditions matched to the declared PN. For jacking, the joint design also has to suit the declared jacking load and the angular deflection capability of the system.
  • ISO 25780 requires assessment of conformity according to CEN/TS 14632, which covers type tests (TT), audit tests (AT), batch release tests (BRT), and process verification tests (PVT). In practice, this connects the product standard to the manufacturer’s quality system.
  • ISO 25780 requires marking on the pipe, and on separately supplied couplings, with the standard reference, diameter, SN, PN, design jacking load, joint type, intended use, manufacturer identification, and date of manufacture. That marking is the main traceability link on site.

What terms does ISO 25780 define?

ISO 25780 defines the main design and test terms used in the standard so that manufacturers and users apply the same ratings and test results.

  • Jacking - a trenchless construction method that installs pipes one by one underground by hydraulic jacks while excavated ground is removed.
  • Design jacking load (Fj,d) - the longitudinal compressive load a pipe can withstand during jacking, allowing for installation partial factors and stress eccentricity.
  • Flexible joint - a joint that allows relative movement between connected components.
  • Nominal stiffness (SN) - the stiffness classification whose numerical value matches the minimum initial value required in N/m².
  • Nominal pressure (PN) - the pressure classification whose numeric value is tied to the component’s pressure rating in bars.
  • Controlled installation process - an installation process where steering and jacking forces are continuously monitored and recorded so that design limits are not exceeded.
  • Type test (TT) - a test carried out to assess whether a product or assembly is fit for its intended function under this document.

Who uses ISO 25780?

ISO 25780 is used by pipe manufacturers, jacking contractors, designers, utilities, and testing laboratories. It is relevant to water supply, irrigation, drainage, sewerage, sewage, and other water-based applications, including raw water, cooling water, potable water, salt water, sea water, and penstocks in power plants and processing plants.

In practice, designers use ISO 25780 to specify pipe stiffness, joint movement capability, and jacking loads. Buyers and quality managers use it to check product declarations, marking, and conformity evidence. Test laboratories use it for the longitudinal compressive tests, ring stiffness checks, joint tests, and the Annex C load calculation support.

What changed in ISO 25780 from the previous edition?

ISO 25780 is the second edition and cancels and replaces ISO 25780:2011. The foreword states that the standard was technically revised.

The changes listed in the document are:

  • Clause 3 was restructured to distinguish measured values and declared values
  • Symbols and abbreviated terms were added
  • The limit state concept with a partial factor method was introduced
  • The nominal pressure classes were reduced
  • Type R and type E-CR reinforcement were added
  • Thermoplastic liner requirements were introduced
  • Assessment of conformity requirements were introduced
  • The jacking diameter and laying length parameters were deleted
  • Longitudinal compressive strength and design load requirements were revised
  • Initial longitudinal compressive modulus by testing was introduced
  • Clause 6 on joints was restructured
  • Annexes A to C were completely updated

Which standards are used with ISO 25780?

ISO 25780 relies on several other standards for test methods, materials, and conformity assessment:

  • ISO 75-2 - gives the deflection temperature under load method used for the resin requirement
  • ISO 604 - provides the plastics compression test basis used in Annex A and Annex B
  • ISO 2602 - supports statistical interpretation of test results and confidence intervals
  • ISO 3126 - gives dimensional measurement methods for plastics piping components
  • ISO 4633 - specifies materials for rubber seals used in water and drainage pipelines
  • ISO 7685 - provides the ring stiffness test for GRP pipes
  • ISO 8639 - gives the leaktightness and structural design test methods for flexible joints
  • ISO 10466 - gives the test for resistance to initial ring deflection
  • ISO 10468 - gives the ring creep test method used for long-term stiffness
  • ISO 10952 - gives the chemical attack test for pipes and fittings in a deflected condition
  • ISO 23856 - provides related requirements for GRP-UP piping systems and GRP fittings between systems covered by this document
  • CEN/TS 14632 - provides conformity assessment procedures and test categories
  • EN 681-1 - gives elastomeric seal material requirements
  • ISO 2394 and EN 1990 - are named in the introduction as the reliability basis for the jacking load design approach

What does the ISO 25780 document contain?

ISO 25780 contains the pipe and joint definitions, the declared dimensions, the material requirements, the joint deflection limits, and the load calculation framework used for jacking design. It also contains tables for nominal pressure classes, pipe straightness, squareness, and joint deflection limits, plus the marking requirements for pipes and couplings.

Annex A gives the prism test piece method for longitudinal compressive stress and modulus, including specimen geometry, conditioning, loading speed, calculations, and test report content. Annex B gives the spool test method with similar procedural detail for initial type testing. Annex C gives the jacking load calculation method, including the partial factors, closed-joint and open-joint cases, and the method for determining the stress eccentricity dependence factor with diagrams and formulas.

Relations

Effective Date
16-Jul-2022

Buy Documents

Standard

ISO 25780:2026 - Plastics piping systems for pressure and non-pressure water supply, drainage or sewerage — Glass-reinforced thermosetting plastics (GRP) systems based on unsaturated polyester (UP) resin — Pipes with flexible joints intended to be installed using jacking techniques

Release Date:20-Nov-2026
English language (43 pages)
sale 15% off
Preview
sale 15% off
Preview

Get Certified

Connect with accredited certification bodies for this standard

DIBt (Deutsches Institut für Bautechnik)

German Institute for Building Technology.

DAKKS Germany Verified

DIN CERTCO

DIN Group product certification.

DAKKS Germany Verified

Zavod za gradbeništvo Slovenije (ZAG) - Inšpekcija

ZAG inspection body for construction products, structures, and materials.

SA Slovenia Verified

Sponsored listings

Frequently Asked Questions

ISO 25780:2026 is a standard published by the International Organization for Standardization (ISO). Its full title is "Plastics piping systems for pressure and non-pressure water supply, drainage or sewerage — Glass-reinforced thermosetting plastics (GRP) systems based on unsaturated polyester (UP) resin — Pipes with flexible joints intended to be installed using jacking techniques". This standard covers: This document specifies the properties of the piping system and its components made from glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester (UP) resin. It is suited for all types of water supply, drainage and sewerage with or without pressure. Types of water supply include, but are not limited to, raw water, irrigation, cooling water, potable water, salt water, sea water, penstocks in power plants, processing plants and other water-based applications. This document is applicable to GRP-UP piping systems, with flexible joints, intended to be installed using jacking techniques. It specifies the characteristics of pipes made from GRP-UP, with or without aggregates or fillers. It also specifies the test parameters for the test methods referred to in this document. This document is applicable to circular pipes and joints with a size range from DN 100 to DN 4 000 at normal service conditions. This document covers requirements to demonstrate the adequacy of the design of the joint and specifies type test performance requirements for the joints as a function of the declared nominal pressure rating of the pipeline system and the required joint deflection capability of the system. The determination of longitudinal compressive properties of a pipe are given in Annex A and Annex B. The procedure for the calculation of the design jacking load on a GRP (UP) pipe is given in Annex C. Requirements for GRP-fittings, used between pipe systems covered by this document, are given in ISO 23856.

This document specifies the properties of the piping system and its components made from glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester (UP) resin. It is suited for all types of water supply, drainage and sewerage with or without pressure. Types of water supply include, but are not limited to, raw water, irrigation, cooling water, potable water, salt water, sea water, penstocks in power plants, processing plants and other water-based applications. This document is applicable to GRP-UP piping systems, with flexible joints, intended to be installed using jacking techniques. It specifies the characteristics of pipes made from GRP-UP, with or without aggregates or fillers. It also specifies the test parameters for the test methods referred to in this document. This document is applicable to circular pipes and joints with a size range from DN 100 to DN 4 000 at normal service conditions. This document covers requirements to demonstrate the adequacy of the design of the joint and specifies type test performance requirements for the joints as a function of the declared nominal pressure rating of the pipeline system and the required joint deflection capability of the system. The determination of longitudinal compressive properties of a pipe are given in Annex A and Annex B. The procedure for the calculation of the design jacking load on a GRP (UP) pipe is given in Annex C. Requirements for GRP-fittings, used between pipe systems covered by this document, are given in ISO 23856.

ISO 25780:2026 is classified under the following ICS (International Classification for Standards) categories: 23.040.20 - Plastics pipes; 91.140.60 - Water supply systems; 91.140.80 - Drainage systems; 93.030 - External sewage systems. The ICS classification helps identify the subject area and facilitates finding related standards.

ISO 25780:2026 has the following relationships with other standards: It is inter standard links to ISO 25780:2011. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

ISO 25780:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


International
Standard
ISO 25780
Second edition
Plastics piping systems for
2026-11
pressure and non-pressure water
supply, drainage or sewerage —
Glass-reinforced thermosetting
plastics (GRP) systems based on
unsaturated polyester (UP) resin —
Pipes with flexible joints intended
to be installed using jacking
techniques
Systèmes de canalisations en matières plastiques pour
l'alimentation en eau, les branchements ou les collecteurs
d'assainissement avec ou sans pression — Systèmes en matières
plastiques thermodurcissables renforcés de verre (PRV) à base de
résine de polyester non saturé (UP) — Tubes avec assemblages
flexibles destinés à être installés par les techniques de poussée
Reference number
© ISO 2026
All rights reserved.
This ISO publication is protected by copyright and is owned by ISO and/or its licensors.
The content of this ISO publication is provided under licence, not sold. Use is subject to the applicable licence terms issued by ISO,
an ISO member body, or an authorized third-party distributor.
Except as required for implementation or expressly permitted by a separate licence, no part of this ISO publication may be
reproduced, distributed, modified, used, or made available in any form or by any means – electronic or mechanical, including
photocopying, scanning, recording, or posting on internal or external digital platforms.
Any use beyond the scope of the granted rights is prohibited and may result in legal action.
ISO copyright office
CP 401 • CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents Page
Foreword .v
Introduction .vii
1 Scope . 1
2 Normative references . 1
3 Terms, definitions, symbols and abbreviated terms . 2
3.1 Terms related to design values declared by the manufacturer .2
3.2 Terms related to measured values .4
3.3 General terms .5
3.4 Symbols and abbreviated terms .11
4 Requirements .13
4.1 Pipe properties . 13
4.1.1 Manufacturer's declared diameters . 13
4.1.2 Design jacking load for closed joint . 13
4.1.3 Nominal stiffness . 13
4.1.4 Nominal pressure . 13
4.1.5 Appearance . 13
4.2 Materials .14
4.2.1 General .14
4.2.2 Reinforcement .14
4.2.3 Resin .14
4.2.4 Aggregates and fillers .14
4.2.5 Thermoplastics liners .14
4.2.6 Elastomers .14
4.2.7 Metals . 15
4.3 Pipe wall construction . 15
4.3.1 Inner layer . 15
4.3.2 Structural layer . 15
4.3.3 Outer layer . 15
4.4 Reference conditions for testing . 15
4.4.1 Temperature . 15
4.4.2 Properties of water for testing . 15
4.4.3 Loading conditions .16
4.4.4 Preconditioning .16
4.4.5 Measurement of dimensions .16
4.5 Elapsed time, x, for determination of long-term properties .16
4.6 Joint properties .16
4.6.1 Types of joint .16
4.6.2 Flexibility of the jointing system .17
4.6.3 Sealing ring . . .18
4.6.4 Effect on water quality .18
4.7 Assessment of conformity .18
5 Pipes . 19
5.1 Geometrical characteristics .19
5.1.1 Wall thickness .19
5.1.2 Nominal length, L .19
5.1.3 Straightness .19
5.1.4 Squareness of end faces.19
5.2 Mechanical characteristics .21
5.2.1 Initial ring stiffness .21
5.2.2 Long-term creep stiffness .21
5.2.3 Initial resistance to failure in a deflected condition .21
5.3 Resistance to strain corrosion .21
5.4 Longitudinal compressive strength .21

iii
5.4.1 General .21
5.4.2 Initial longitudinal compressive stress at break (prism test pieces) . 22
5.4.3 Initial longitudinal compressive stress at break (spool test pieces) . 22
5.4.4 Requirements . 22
5.5 Design loads . 22
5.5.1 Design longitudinal load . . 22
5.5.2 Design jacking load . . 22
5.6 Longitudinal compressive modulus . 22
5.6.1 Initial longitudinal compressive modulus (prism test pieces). 22
5.6.2 Initial longitudinal compressive modulus (spool test pieces) . 22
5.6.3 Declared value . 23
5.7 Resistance of pressure pipes to internal pressure . 23
5.8 Marking . 23
6 Joints .23
6.1 General requirements . 23
6.2 Performance requirements .24
6.3 Geometrical characteristics .24
6.4 Interchangeability . 25
6.5 Marking . 25
Annex A (normative) Determination of the longitudinal compressive properties of a pipe, using
a sample of prism test pieces cut from a ring from the pipe .26
Annex B (normative) Determination of the longitudinal compressive properties of pipes, using
spool test pieces .32
Annex C (normative) Procedure for the calculation of the design jacking load on a GRP (UP)
pipe, F .38
j,d
Bibliography .43

iv
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 138, Plastics pipes, fittings and valves for the
transport of fluids, Subcommittee SC 6, Reinforced plastics pipes and fittings for all applications.
This second edition cancels and replaces the first edition (ISO 25780:2011), which has been technically
revised.
The main changes are as follows:
— Clause 3 has been restructured to distinguish measured values and declared values (see 3.1 and 3.2).
— An overview of symbols and abbreviated terms has been introduced (see 3.4).
— The limit state concept used in conjunction with a partial factor method has been introduced.
— The nominal pressure classes have been reduced (see Table 1).
— Type “R” and type “E-CR” have been added as additional reinforcement types (see 4.2.2).
— Requirements for thermoplastic liners have been introduced (see 4.2.5).
— Requirements for the assessment of conformity have been introduced (see 4.7).
— The parameters “jacking diameter” and “laying length” have been deleted.
— The requirements on longitudinal compressive strength as well as design loads have been completely
revised (see 5.4 and 5.5).
— The determination of the initial longitudinal compressive modulus by testing has been introduced.
— Clause 6 on joints has been restructured.
— Annexes A to C have been completely updated.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.

v
vi
Introduction
A jacking technique is a trenchless construction method which installs a pipeline by inserting pipes one
by one under the ground by pressing with one or more hydraulic jacks, while the excavated ground is
simultaneously evacuated.
In this document, the requirements for design jacking load on glass-reinforced thermosetting plastics (GRP)
pipes are based on the general principle for the reliability of structures detailed in ISO 2394 and in EN 1990.
These reference documents provide procedures for the harmonization of design practices and address the
probability of failure, as well as possible consequences of failures. The design practices are based on a partial
safety factor concept, as well as on risk management engineering.

vii
International Standard ISO 25780:2026(en)
Plastics piping systems for pressure and non-pressure
water supply, drainage or sewerage — Glass-reinforced
thermosetting plastics (GRP) systems based on unsaturated
polyester (UP) resin — Pipes with flexible joints intended to
be installed using jacking techniques
1 Scope
This document specifies the properties of the piping system and its components made from glass-reinforced
thermosetting plastics (GRP) based on unsaturated polyester (UP) resin. It is suited for all types of water
supply, drainage and sewerage with or without pressure. Types of water supply include, but are not limited
to, raw water, irrigation, cooling water, potable water, salt water, sea water, penstocks in power plants,
processing plants and other water-based applications.
This document is applicable to GRP-UP piping systems, with flexible joints, intended to be installed using
jacking techniques. It specifies the characteristics of pipes made from GRP-UP, with or without aggregates
or fillers. It also specifies the test parameters for the test methods referred to in this document.
This document is applicable to circular pipes and joints with a size range from DN 100 to DN 4 000 at normal
service conditions.
This document covers requirements to demonstrate the adequacy of the design of the joint and specifies
type test performance requirements for the joints as a function of the declared nominal pressure rating of
the pipeline system and the required joint deflection capability of the system.
The determination of longitudinal compressive properties of a pipe are given in Annex A and Annex B.
The procedure for the calculation of the design jacking load on a GRP (UP) pipe is given in Annex C.
Requirements for GRP-fittings, used between pipe systems covered by this document, are given in ISO 23856.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes
requirements of this document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 75-2, Plastics — Determination of temperature of deflection under load — Part 2: Plastics and ebonite
ISO 604:2002, Plastics — Determination of compressive properties
ISO 3126, Plastics piping systems — Plastics components — Determination of dimensions
ISO 4633, Rubber seals — Joint rings for water supply, drainage and sewerage pipelines — Specification for
materials
ISO 7685, Glass-reinforced thermosetting plastics (GRP) pipes — Determination of initial ring stiffness
ISO 8639, Glass-reinforced thermosetting plastics (GRP) pipes and fittings — Test methods for leaktightness and
proof of structural design of flexible joints
ISO 10466, Glass-reinforced thermosetting plastics (GRP) pipes — Test method to prove the resistance to initial
ring deflection
ISO 10468, Glass-reinforced thermosetting plastics (GRP) pipes — Determination of the ring creep properties
under wet or dry conditions
ISO 10952, Glass-reinforced thermosetting plastics (GRP) pipes and fittings — Determination of the resistance
to chemical attack for the inside of a section in a deflected condition
ISO 23856, Plastics piping systems for pressure and non-pressure water supply, drainage or sewerage — Glass-
reinforced thermosetting plastics (GRP) systems based on unsaturated polyester (UP) resin
CEN/TS 14632, Plastics piping systems for drainage, sewerage and water supply, pressure and non-pressure —
Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP) — Guidance for the
assessment of conformity
3 Terms, definitions, symbols and abbreviated terms
For the purposes of this document, the following terms and definitions, symbols and abbreviated terms
apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1 Terms related to design values declared by the manufacturer
3.1.1
pipe outside diameter
jacking diameter
d
OD
manufacturer's declared value for the maximum external diameter of the pipe barrel
Note 1 to entry: The pipe outside diameter is expressed in millimetres (mm).
Note 2 to entry: See Figure 1.
3.1.2
maximum spigot inside diameter
d
i,max
manufacturer's declared value for the maximum internal diameter of the pipe spigot, at the groove location
where applicable
Note 1 to entry: See Figure 1.
3.1.3
minimum spigot or groove diameter
d
g,min
manufacturer's declared value for the minimum external diameter of the spigot (see Figure 1 a) diameter),
or in the groove of the spigot (see Figure 1 b) diameter, if applicable)
Note 1 to entry: Spigot or groove diameter is expressed in millimetres (mm).
Note 2 to entry: See Figure 1.
3.1.4
minimum wall thickness
e
min
manufacturer's declared value for the minimum wall thickness of the pipe barrel
Note 1 to entry: The minimum wall thickness is expressed in millimetres (mm).
Note 2 to entry: See Figure 1.

3.1.5
cross-sectional area at the spigot
A
s
minimum area of the cross-section of the pipe at the spigot, or in the groove of the spigot, if applicable
Note 1 to entry: Minimum cross-sectional area at the spigot is derived using the following formula and is expressed in
square millimetres (mm ):
2 2
 
Ad  05,, 05d .
 
sg ,min i,max 
 
Note 2 to entry: See Figure 1.
3.1.6
cross-sectional area at the barrel
A
b
area of the cross-section of the pipe barrel
Note 1 to entry: The cross-sectional area at the pipe barrel is derived using the following formula and is expressed in
square millimetres (mm ):
 
Ad  05,, 05d .
 
bO Di,max 
 
Note 2 to entry: See Figure 1.
a) Section through a rebated un-grooved spigot b) Section through a rebated grooved spigot
Key
d pipe outside diameter, in mm
OD
d maximum spigot inside diameter, in mm
i,max
d minimum spigot or groove diameter, in mm
g,min
e minimum wall thickness of pipe, in mm
min
Figure 1 — Diameters declared by the manufacturer
3.1.7
declared initial longitudinal compressive stress at break
σ
b
manufacturer's declared minimum value, derived from tests, for the initial longitudinal compressive stress
at break of the pipe
Note 1 to entry: When tested in accordance with Annex B, the minimum initial longitudinal compressive stress at
break is expressed in megapascals (MPa).

3.1.8
declared initial longitudinal compressive modulus
E
c
manufacturer's declared value, derived from tests, for the initial longitudinal compressive modulus
Note 1 to entry: When tested in accordance with Annex A or Annex B, the declared initial longitudinal compressive
modulus is expressed in megapascals (MPa).
3.2 Terms related to measured values
3.2.1
mean diameter
d
m
diameter of the circle corresponding to the middle of the pipe wall cross-section and given by the following
formula:
dde
me
where
d is the measured external diameter, in mm;
e
e is the measured wall thickness of the pipe, in mm
Note 1 to entry: The mean diameter is expressed in millimetres (mm).
Note 2 to entry: If measured values are not available (e.g. for design purposes) declared values may be used.
Note 3 to entry: See Figure 2.
a) Section through a rebated un-grooved spigot b) Section through a rebated grooved spigot
Key
d measured external diameter, in mm
e
d measured spigot inside diameter, in mm
i
d measured spigot or groove diameter, in mm
g
d mean diameter, in mm
m
e measured wall thickness of pipe, in mm
Figure 2 — Measured diameters
[SOURCE: ISO 23856:2021, 3.3, modified — the first formula has been removed and Notes 2 and 3 to entry
have been added.]
3.3 General terms
3.3.1
jacking
trenchless construction method which installs a pipeline by inserting pipes one by one under the ground by
pressing with one or more hydraulic jacks, while the excavated ground is simultaneously evacuated from
the cutting head
3.3.2
nominal length
pipe length without tolerance
Note 1 to entry: The nominal length is expressed in metres (m).
3.3.3
initial longitudinal compressive modulus (prism test piece)
E
c,p
ratio of the applied stress to the resulting strain below the elastic limit, both measured concurrently during
a short-term compression test with prism
Note 1 to entry: When tested in accordance with Annex A, the initial longitudinal compressive modulus is expressed
in megapascals (MPa).
3.3.4
initial longitudinal compressive modulus (spool test piece)
E
c,s
ratio of the applied stress to the resulting strain below the elastic limit, both measured concurrently during
a short-term compression test with spool
Note 1 to entry: When tested in accordance with Annex B, the initial longitudinal compressive modulus is expressed
in megapascals (MPa).
3.3.5
design longitudinal load
F
d
design value of the concentric longitudinal load that the pipe withstands, taking into account the material
partial factor
Note 1 to entry: The ultimate longitudinal load is determined using the following formula and is expressed in
kilonewtons (kN):
1 1
FA 
db s
1000 
M
where
σ is the declared minimum initial compressive stress at break, in MPa;
b
A is the pipe cross-sectional area at the spigot, in mm ;
s
γ is the material partial factor, γ = 1,37; see also Table C.1.
M M
3.3.6
design jacking load
F
j,d
longitudinal compressive load that a pipe can withstand during a jacking operation, taking into account the
installation partial factor and the stress eccentricity dependence factor
Note 1 to entry: The design jacking load is determined using the following formula and is expressed in kilonewtons
(kN):
F
d
F 
jd,
S 
 i
where
F is the design longitudinal load, in kN;
d
S is the stress eccentricity dependence factor, with S ≥ 2;
σ σ
γ is the installation partial factor, see Table C.1.
i
Note 2 to entry: For the design jacking load for closed joint (considering full contact between the spigots) the stress
eccentricity dependence factor S = 2.
σ
Note 3 to entry: For the design jacking load for open joint (considering incomplete contact between the spigots) the
stress eccentricity dependence factor S > 2. For the determination of S , see C.2.5.1.
σ σ
3.3.7
nominal stiffness
SN
alphanumerical designation for stiffness classification purposes, which has the same numerical value as the
minimum initial value required, when expressed in newtons per square metre (N/m )
Note 1 to entry: The designation for reference or marking purposes consists of the letters SN plus a number.
[SOURCE: ISO 23856:2021, 3.8, modified — Note 1 to entry has been removed.]
3.3.8
ring stiffness
S
physical characteristic of the pipe which is a measure of the resistance to ring deflection per metre length
under external load
Note 1 to entry: Ring stiffness is determined using the following formula and is expressed in newtons per square
metre (N/m ):
EI
S 
d
m
where
E is the apparent modulus of elasticity, which can be derived from the result of the ring stiffness
test, i.e. ISO 7685, in N/m ;
d is the mean diameter, in m;
m
I is the second moment of area in the longitudinal direction per metre length, in m /m;
e
I=
where e is the measured wall thickness of pipe, in m.
3.3.9
initial ring stiffness
S
value of ring stiffness, S, obtained when tested according to ISO 7685
Note 1 to entry: The initial stiffness is computed by:

  
 y 
5
1860 2500 10
 
 
 
d
 
  
m
S 
Ly kd
R mm
0,3927
F Ge
R
where
y is the measured deflection, in m;
d is the mean diameter, in m;
m
L is the length of the specimen, in m;
R
F is the measured load, in N;
R
k is a shape factor for the wall cross-section, which can be assumed to be equal to 1,2,
dimensionless;
G is the shear modulus, in N/m .
Note 2 to entry: The shear modulus to be used in the calculation can be determined through calibration between
measured and computed values on various products, or other suitable means.
Note 3 to entry: Initial ring stiffness is expressed in newtons per square metre (N/m ).
Note 4 to entry: The test shall be performed at relative deflection, y/d calculated by:
m
y
% 

d 3
m
SN
3.3.10
calculated long-term ring creep stiffness
S
x
calculated value of ring creep stiffness, S, at x years
Note 1 to entry: Long-term ring creep stiffness is obtained using the following formula:
SS
xx01,,creep
where
x is the elapsed time as specified in this document (see 4.5), in years;
α is the creep factor at x years, determined according to ISO 10468 under wet conditions;
x,creep
S is the ring stiffness at position 1 at 0,1 h.
0,1
3.3.11
pressure pipe
pipe having a nominal pressure (3.3.13) (PN) classification greater than 1 bar and which is intended to be
used with the internal pressure equal to or less than its nominal pressure when expressed in bars
5 2
Note 1 to entry: 1 bar = 0,1 MPa = 10 Pa; 1 MPa = 1 N/mm .
3.3.12
non-pressure pipe
pipe subjected to an internal pressure not greater than 1 bar
5 2
Note 1 to entry: 1 bar = 0,1 MPa = 10 Pa; 1 MPa = 1 N/mm .

3.3.13
nominal pressure
PN
alphanumeric designation for pressure classification purposes, which has a numerical value equal to the
resistance of a component of a piping system to internal pressure
Note 1 to entry: Nominal pressure is a designation for reference or marking purposes that consists of the letters PN
plus a number which is related to a component's pressure rating in bars.
5 2
Note 2 to entry: 1 bar = 0,1 MPa = 10 Pa; 1 MPa = 1 N/mm .
3.3.14
normal service conditions
conveyance of water or sewage, in the temperature range of 2 °C to 50 °C, with or without pressure, for
50 years
3.3.15
service temperature
maximum sustained temperature at which the system is expected to operate continuously
Note 1 to entry: Service temperature is expressed in degrees Celsius (°C).
3.3.16
rerating factor
R
RF
multiplication factor that quantifies the relation between a mechanical, physical or chemical property at the
service condition compared to the respective value at 23 °C and 50 % relative humidity (RH)
3.3.17
relative ring deflection
y/d
m
ratio of the change in diameter of a pipe, y, in metres, to its mean diameter, d , in metres
m
Note 1 to entry: Relative ring deflection is derived as a percentage, %, i.e.:
 
y
100 .
 
 
d
 
m
3.3.18
type test
TT
test carried out in order to assess the fitness for purpose of a product or assembly of components to fulfil its
or their function(s) according to this document
3.3.19
flexible joint
joint which allows relative movement between components being joined
3.3.20
flush coupling
joint component with either an external diameter equal to the pipe's outside diameter or an inside diameter
equal to the pipe's inside diameter
Note 1 to entry: The term "equal" in this case means including tolerances.
3.3.21
closed joint
joint condition where the pipe ends, with or without a transfer ring, are in full contact around the whole
circumference
3.3.22
open joint
joint condition where the pipe ends, with or without a transfer ring, are in incomplete contact with each
other thereby forming a gap
3.3.23
angular deflection
δ
angle between the axes of two adjacent pipes
Note 1 to entry: Angular deflection (see Figure 3 b)) is expressed in degrees (°).
3.3.24
draw
D
longitudinal movement of a joint
Note 1 to entry: Draw (see Figure 3 a)) is expressed in millimetres (mm).
3.3.25
total draw
T
sum of the draw, D, and the additional longitudinal movement, J, due to the presence of angular deflection
Note 1 to entry: Total draw (see Figure 3 c)) is expressed in millimetres (mm).
3.3.26
deformation
M
pipe deformation in the coupling as a result of a vertical force of 20 N/mm of the maximum spigot inside
diameter d , on the pipe and a supported coupling causing a step between the two pipe spigots at the
i,max
loading position
Note 1 to entry: Deformation (see Figure 3 d)) is expressed in millimetres (mm).
a) Draw
b) Angular deflection
c) Total draw
d) Deformation
Key
D draw
J longitudinal movement arising from angular deflection of the joint
δ angular deflection of the joint
T total draw
M deformation
NOTE The joint in this figure is an example of a typical joint but is not intended to fix design. Other joints are
available.
Figure 3 — Joint movements
3.3.27
break
condition where the test piece can no longer carry the load to which it is being subjected
3.3.28
thickness to diameter ratio
e /d
min OD
ratio between the minimum wall thickness of pipe, e , and the pipe outside diameter, d , expressed in per
min OD
thousand, ‰
3.3.29
controlled installation process
installation process during which the steering and jacking forces are continuously monitored and recorded
to ensure that design limits on angular deflection and jacking load are not exceeded
3.3.30
uncontrolled installation process
installation process during which the steering and jacking forces are not continuously monitored and
recorded
3.4 Symbols and abbreviated terms
A initial mean cross-sectional area
A cross-sectional area at the barrel
b
A cross-sectional area at the spigot
s
A calculated minimum area of the cross-section of the pipe at the spigot, or in the groove
spool
of the spigot
a deflection offset
D draw
d measured external diameter of the flush coupling
c
d measured external diameter
e
d measured spigot or groove diameter
g
d minimum spigot or groove diameter
g,min
d measured spigot inside diameter
i
d maximum spigot inside diameter
i,max
d mean diameter
m
d pipe outside diameter
OD
d deviation from squareness across a joint's external diameter
sq,d
d deviation from squareness across a joint's wall thickness
sq,e
E apparent modulus of elasticity
E declared initial longitudinal compressive modulus
C
E initial longitudinal compressive modulus (prism test piece)
c,p
E initial longitudinal compressive modulus (spool test piece)
c,s
e measured wall thickness of pipe
e/d thickness to diameter ratio
OD
e minimum wall thickness of pipe
min
F compressive load
F measured load
R
F maximum compressive force at failure
c
F design longitudinal load
d
F design jacking load
j,d
F load at fracture
fr
f test piece de-rating factor
s
G shear modulus
h measured height of test piece
I second moment of area in the longitudinal direction
J longitudinal movement arising from angular deflection of the joint
k shape factor for the wall cross-section
L nominal length
L actual length of the pipe
p
L length of the specimen
R
L length of the test spool
S
L measured length of coupling
c
M deformation
p probability of failure
f
R rerating factor
RF
R slenderness ratio
SL
r radius of gyration for a rectangle
G
S ring stiffness
S initial ring stiffness
S ring stiffness at position 1 at 0,1 h
0,1
S calculated long-term ring creep stiffness
x
S minimum long-term creep stiffness
x, creep, min
S stress eccentricity dependence factor
σ
T total draw
T measured spigot thickness
g
T minimum spigot thickness
g,min
w measured width of test piece
X coefficient
x elapsed time
x measured rebated length
x measured distance from the groove to spigot end
y measured deflection
y/d relative ring deflection
m
(y /d ) initial relative ring deflection at 2 min
2, bore m min
Z diametrical extent of compression in the joint segments
α creep factor at x years
x,creep
δ angular deflection
ε strain
x
ε strain at failure
b
γ total safety factor
γ installation partial factor
i
γ material partial factor
M
η coefficient
λ coefficient
φ angular deflection, in accordance with the design jacking load
v number equal to the component's nominal pressure
σ declared initial longitudinal compressive stress at break
b
σ initial longitudinal compressive stress at break (spool test piece)
b,s
σ individual value of the initial longitudinal compressive stress at break (prism test piec-
b,p;QC,i
es) for quality control
σ stress at the value of the strain ε = 0,000 5
1 1
σ stress at the value of the strain ε = 0,002 5
2 2
ξ coefficient
subscript referring to individual test piece
i
subscript referring to individual gauge
j
AT audit test
BRT batch release test
CC consequence class
GRP glass reinforced thermosetting plastics

DN nominal size
ITT initial type test
PN nominal pressure
PVT process verification tests
TT type test
SN nominal stiffness
UP unsaturated polyester
4 Requirements
4.1 Pipe properties
4.1.1 Manufacturer's declared diameters
The outside diameter d and its tolerances shall be designated by the manufacturer. The manufacturer
OD
shall also declare the maximum spigot inside diameter, d .
i,max
4.1.2 Design jacking load for closed joint
The manufacturer shall declare the design jacking load for closed joint that can be applied to the pipe during
the jacking operation, in kilonewtons.
4.1.3 Nominal stiffness
For jacking applications, the pipe shall have a nominal stiffness of at least SN 20 000. The nominal stiffness
shall be at least SN 30 000 for the following conditions: curved installations, uncontrolled installations, or
installation lengths of more than 50 m.
NOTE This requirement for SN 30 000 as a minimum is to prevent failures of the spigot due to lateral forces
resulting from the curvature and/or steering of the tunnel boring machine.
4.1.4 Nominal pressure
The nominal pressure (PN) shall conform to one of those given in Table 1.
Where pressure ratings other than the nominal values in Table 1 are to be supplied, by agreement betw
...