SIST EN 61196-2:2004
(Main)Radio-frequency cables -- Part 2: Sectional specification for semi-rigid radio-frequency and coaxial cables with polytetrafluoroethylene (PTFE) insulation
Radio-frequency cables -- Part 2: Sectional specification for semi-rigid radio-frequency and coaxial cables with polytetrafluoroethylene (PTFE) insulation
Prescribes recommended ratings and characteristics. Selects from the generic specification the appropriate quality assessment procedures, test and measuring methods. Gives general performance requirements for semi-rigid coaxial cables plus complementry test methods.
Hochfrequenzkabel -- Teil 2: Rahmenspezifikation für halb-starre Hochfrequenz- und Koaxialkabel mit Polytetrafluorethylen (PTFE) Isolation
Câbles pour fréquences radioélectriques -- Partie 2: Spécification intermédiaire pour câbles coaxiaux et semi-rigides pour fréquences radioélectriques à isolation polytétrafluoroéthylène
Définit les exigences relatives aux câbles semi-rigides coaxiaux pour fréquences radioélectriques, avec isolation polytétrafluoroéthylène (PTFE). Prescrit les performances et les caractéristiques recommandées. Sélectionne, dans la spécification générique, les procédures d'assurance de qualité, les méthodes d'essai et de mesure appropriées, et donne les exigences générales de perfomance pour les câbles coaxiaux semi-rigides, ainsi que des méthodes d'essais complémentaires.
Radio-frequency cables - Part 2: Sectional specification for semi-rigid radio-frequency and coaxial cables with polytetrafluoroethylene (PTFE) insulation (IEC 61196-2:1995)
General Information
Relations
Standards Content (Sample)
SLOVENSKI SIST EN 61196-2:2004
STANDARD
april 2004
Radio-frequency cables - Part 2: Sectional specification for semi-rigid radio-
frequency and coaxial cables with polytetrafluoroethylene (PTFE) insulation (IEC
61196-2:1995)
ICS 33.120.10 Referenčna številka
SIST EN 61196-2:2004(en)
© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD EN 61196-2
NORME EUROPÉENNE
EUROPÄISCHE NORM October 2003
ICS 33.120.10
English version
Radio-frequency cables
Part 2: Sectional specification for semi-rigid radio-frequency
and coaxial cables with polytetrafluoroethylene (PTFE) insulation
(IEC 61196-2:1995)
Câbles pour fréquences radioélectriques Hochfrequenzkabel
Partie 2: Spécification intermédiaire Teil 2: Rahmenspezifikation für halb-starre
pour câbles coaxiaux et semi-rigides Hochfrequenz- und Koaxialkabel mit
pour fréquences radioélectriques Polytetrafluorethylen (PTFE) Isolation
à isolation polytétrafluoroéthylène (IEC 61196-2:1995)
(CEI 61196-2:1995)
This European Standard was approved by CENELEC on 2003-10-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61196-2:2003 E
---------------------- Page: 2 ----------------------
EN 61196-2:2003 – 2 –
Foreword
The text of the International Standard IEC 61196-2:1995, prepared by SC 46A, Coaxial cables, of
IEC TC 46, Cables, wires, waveguides, r.f. connectors, r.f. and microwave passive components and
accessories, was submitted to the formal vote and was approved by CENELEC as EN 61196-2 on
2003-10-01.
This European Standard supersedes EN 61196-2:1995.
The following dates were fixed:
- latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2004-10-01
- latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2006-10-01
Annexes designated "normative" are part of the body of the standard.
Annexes designated "informative" are given for information only.
In this standard, annex ZA is normative and annex A is informative.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61196-2:1995 was approved by CENELEC as a European
Standard without any modification.
__________
---------------------- Page: 3 ----------------------
– 3 – EN 61196-2:2003
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
This European Standard incorporates by dated or undated reference, provisions from other publications.
These normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications
apply to this European Standard only when incorporated in it by amendment or revision. For undated
references, the latest edition of the publication referred to applies (including amendments).
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.
Publication Year Title EN/HD Year
IEC 60028 1925 International standard of resistance for - -
copper
1)
IEC 60068-2-20 1979 Basic environmental testing procedures HD 323.2.20 S3 1988
Part 2: Tests - Test T: Soldering
IEC 61196-1 1995 Radio-frequency cables - -
Part 1: Generic specification - General,
definitions, requirements and test
methods
1)
HD 323.2.20 S3:1988 is based on IEC 60068-2-20:1979 + A2:1987.
---------------------- Page: 4 ----------------------
CEI
NORME
IEC
INTERNATIONALE
1196-2
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
1995-06
Câbles pour fréquences radioélectriques -
Partie 2:
Spécification intermédiaire pour câbles coaxiaux
et semi-rigides pour fréquences radioélectriques
à isolation polytétrafluoroéthylène
Radio-frequency cables -
Part 2:
Sectional specification for semi-rigid
radio-frequency and coaxial cables
with polytetrafluoroethylene (PTFE) insulation
CEI 1995 Droits — Copyright — all rights reserved
© de reproduction réservés
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun pro- any form or by any means, electronic or mechanical,
cédé, électronique ou mécanique, y compris la photocopie et including photocopying and microfilm, without permission
les microfilms, sans l'accord écrit de l'éditeur. in writing from the publisher.
Bureau Central de la Commission Electrotechnique Internationale 3, rue de Varembé Genève, Suisse
Commission Electrotechnique Internationale CODE PRIX
International Electrotechnical Commission PRICE CODE
IEC Menutynaponuan 3neurporexHH4ecuaa HOMHCCHA
• Pour prix, voir catalogue en vigueur
For price, see current cata logue
---------------------- Page: 5 ----------------------
1196-2©IEC:1995 - 3 -
CONTENTS
Page
FOREWORD 5
Clause
SECTION 1: GENERAL
1.1 Scope and object 7
1.2 Normative references 7
1.3 Definitions 7
1.4 Information to be given in a detail specification 9
1.4.1 Outline drawing and dimensions 9
1.4.2 Materials 9
1.4.3 Ratings and characteristics 9
1.4.4 Marking of package 9
SECTION 2: RATINGS AND CHARACTERISTICS
2.1 Climatic category 9
2.2 Recommended ratings 11
2.2.1 Characteristic impedance 11
2.2.2 Tolerance on characteristic impedance 11
2.2.3 Rated temperature 11
SECTION 3: ADDITIONAL REQUIREMENTS
3.1 Design and construction of outer conductor 11
3.2 Tests and measurements 13
3.2.1 Dimensions 13
3.2.2 Electrical tests 13
3.2.3 Mechanical and climatic tests 17
SECTION 4: QUALITY ASSESSMENT PROCEDURES
4.1 Primary stage of manufacture 21
4.2 Structurally similar cables 21
4.3 Qualification approval 23
Annex A - Examples of detail specifications 25
---------------------- Page: 6 ----------------------
1196-2 ©IEC:1995 - 5 -
INTERNATIONAL ELECTROTECHNICAL COMMISSION
RADIO-FREQUENCY CABLES -
Part 2: Sectional specification for semi-rigid
radio-frequency and coaxial cables
with polytetrafluoroethylene (PTFE) insulation
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization
comprising all national electrotechnical committees (IEC National Committees). The object of the IEC is to
promote international cooperation on all questions concerning standardization in the electrical and
electronic fields. To this end and in addition to other activities, the IEC publishes International Standards.
Their preparation is entrusted to technical committees; any IEC National Committee interested in
the subject dealt with may participate in this preparatory work. International, governmental and
non-governmental organizations liaising with the IEC also participate in this preparation. The IEC
collaborates closely with the International Organization for Standardization (ISO) in accordance with
conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of the IEC on technical matters, prepared by technical committees on
which all the National Committees having a special interest therein are represented, express, as nearly as
possible, an international consensus of opinion on the subjects dealt with.
3) They have
the form of recommendations for international use published in the form of standards, technical
reports or guides and they are accepted by the National Committees in that sense.
4)
In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5)
The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
International Standard IEC 1196-2 has been prepared by sub-committee 46A: Coaxial
cables, of IEC technical committee 46: Cables, wires, waveguides, r.f. connectors and
accessories for communication and signalling.
This second edition cancels and replaces the first edition published in 1993 of which it
constitutes a minor revision.
IEC 1196-2 constitutes pa rt 2 of a series of publications under the general title: Radio-
frequency cables.
Annex A is for information only.
---------------------- Page: 7 ----------------------
1196-2 ©IEC:1995 - 7 -
RADIO-FREQUENCY CABLES -
Part 2: Sectional specification for semi-rigid
radio-frequency and coaxial cables
with polytetrafluoroethylene (PTFE) insulation
Section 1: General
1.1 Scope and object
This sectional specification specifies requirements for semi-rigid radio frequency and
coaxial cables with polytetrafluoroethylene (PTFE) insulation.
It is intended to be used with the generic specification (IEC 1196-1).
The object of this sectional specification is to prescribe recommended ratings and
characteristics and to select from the generic specification the appropriate quality
rformance
assessment procedures, test and measuring methods, and to give general pe
requirements for semi-rigid coaxial cables plus complementary test methods. Test
severities and requirements prescribed in detail specifications referring to this sectional
specification should be of equal or higher performance levels.
1.2 Normative references
The following normative documents contain provisions which, through reference in this
text, constitute provisions of this sectional specification. At the time of publication, the
editions indicated were valid. All normative documents are subject to revision, and parties
to agreements based on this sectional specification are encouraged to investigate the
possibility of applying the most recent editions of the normative documents indicated
below. Members of IEC and ISO maintain registers of currently valid International
Standards.
IEC 28: 1925, International Standard of resistance for copper
IEC 68-2-20: 1979, Environmental testing - Part 2: Tests - Test T: Soldering
IEC 1196-1: 1995, Radio-frequency cables - Part 1: Generic specification: General,
definitions, requirements and test methods
1.3 Definitions
For the definitions of general terms used in this specification, reference should be made to
the generic specification.
---------------------- Page: 8 ----------------------
1196-2 ©IEC:1995 - 9 -
1.4 Information to be given in a detail specification
Detail specifications shall not specify requirements inferior to those in the generic or
sectional specification. When more severe requirements are included, they shall be listed
in the detail specification and indicated in the test schedules.
Information covered in 1.4.1 to 1.4.4 shall be included in the detail specification and the
value quoted shall be selected from the preferred values given in this sectional
specification. Examples of detail specifications are given in annex A.
1.4.1 Outline drawing and dimensions
There shall be an illustration of the cable as an aid to easy recognition and for comparison
of the cable to others. As a minimum requirement, the diameter of the dielectric and the
outer diameter of the cable shall be specified. All dimensions and their tolerances which
affect interchangeability and termination shall be given in millimetres and tabulated below
the drawing.
1.4.2 Materials
The detail specification shall specify the materials of both the inner and outer conductors.
The insulation shall be of solid polytetrafluoroethylene having a thickness as specified in
the detail specification.
1.4.3 Ratings and characteristics
The ratings and characteristics shall be in accordance with the relevant clauses of this
specification.
1.4.4 Marking of package
The package containing the cable shall be clearly marked with the manufacturer's name
and the cable IEC type designation.
Section 2: Ratings and characteristics
The values given in the detail specification shall be selected from the following
recommended requirements.
2.1 Climatic category
Due to the particular structure of semi-rigid coaxial cables and the associated differential
thermal expansion coefficients of materials, rated temperatures are specific for each cable
and shall be given in the detail specification.
---------------------- Page: 9 ----------------------
1196-2 ©IEC:1995 - 11 -
The operating temperature range is between the limits within which a cable may be
operated continuously without any reduction in the basic properties of the cable. This
includes the ambient temperature plus the increased temperature due to cable operation.
The temperature range is given as a guideline, since the mechanical, environmental and
electrical requirements of the application can affect the operating temperature range. In no
case shall the testing temperatures be considered as giving the operating temperature
range. Testing is usually carried out under accelerated conditions in an attempt to reveal
any faults in the materials used in the construction of the cable assembly.
The maximum power-handling capability, in watts, is the amount of power that a coaxial
cable can safely transmit without overheating or developing a dielectric breakdown
throughout the usable frequency range. The safe power-handling capabilities are shown
on the associated curves. These curves have been derated with an assumption of a
VSWR of 2 and an ambient temperature of 25 °C. The curves have also taken into account
the effects of a typical system installation, for example bends, clamps and thermally insu-
lated sections.
2.2 Recommended ratings
2.2.1 Characteristic impedance
Preferred values are 50 S2 or 75 S2.
2.2.2 Tolerance on characteristic impedance
Tolerances on rated characteristic impedances shall be selected from the following values:
±0,5 S2, ±1 S2, ±1,5 S2, ±2 S2
2.2.3 Rated temperature
The standard value of rated temperature is 20 °C.
Section 3: Additional requirements
3.1 Design and construction of outer conductor
The outer conductor shall be a smooth and continuous metallic tube, either of copper or
light metal alloy.
Copper
The type used shall be annealed, electrolytically refined with a copper content of at least
99,9 % and an electrical conductivity of at least 100 % according to IEC 28.
---------------------- Page: 10 ----------------------
1196-2 ©IEC:1995 - 13 -
The mechanical characteristics of the copper tube shall comply with a flattening and
bending test which is carried out on a section of tube. The tube shall be completely
flattened and then folded back on itself. After this test the tube shall not exhibit splits,
cracks, fissures or tears.
Light metal alloy
Under consideration.
3.2 Tests and measurements
3.2.1 Dimensions
3.2.1.1 Eccentricity of dielectric
The eccentricity of the dielectric shall be measured in accordance with the method
specified in 9.2 of the generic specification.
3.2.1.1.1 Requirements
The lowest measured value of the dielectric core thickness shall be at least 85 % of the
highest measured value in the same cross-section.
3.2.2 Electrical tests
3.2.2.1 Structural ret
...
Questions, Comments and Discussion