Heat pumps with electrically driven compressors - Testing and requirements for marking of domestic hot water units

This European Standard specifies methods for testing and reporting of the rating and it specifies requirements for marking of air/water, brine/water, water/water and direct exchange/water heat pumps with electrically driven compressors connected to or including a domestic hot water storage tank. When these units are used for space heating, then EN 14511 (all parts) applies.
In case of air-to-water heat pumps, this European Standard comprises only factory-made units which can be ducted on the airside.
This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system.
NOTE   Testing procedures for simultaneous operation for domestic hot water production and space heating are not treated in this standard. Simultaneous means that domestic hot water production and space heating generation occur at the same time and may interact.
In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package.
This European Standard does not include any requirement about the quality of water.

Wärmepumpen mit elektrisch angetriebenen Verdichtern - Prüfungen und Anforderungen an die Kennzeichnung von Geräten zum Erwärmen von Brauchwarmwasser

Diese Europäische Norm legt Verfahren zur Prüfung und Angabe der Leistung fest und enthält Anforderungen an die Kennzeichnung von Luft/Wasser , Sole/Wasser , Wasser/Wasser  und Direktaustausch/
Wasser Wärmepumpen mit elektrisch angetriebenen Verdichtern zum Erwärmen von Brauchwarmwasser. Werden diese Geräte für die Raumheizung eingesetzt, dann gilt EN 14511 alle Teile.
Im Falle von Luft-/Wasser Wärmepumpen umfasst diese Europäische Norm nur fabrikgefertigte Geräte, die an der Luftseite mit Luftkanälen versehen sein können.
Diese Europäische Norm umfasst nur das Prüfverfahren für die Brauchwarmwasserbereitung der Wärme-pumpensysteme.
ANMERKUNG   Prüfverfahren für gleichzeitige Brauchwarmwasserbereitung und Raumheizung sind in dieser Norm nicht behandelt. Gleichzeitig bedeutet, dass die Brauchwarmwasserbereitung und die Wärmeerzeugung für die Raumheizung zur gleichen Zeit erfolgen und in Wechselwirkung treten können.
Bei Geräten, die aus mehreren Anlagenteilen bestehen, gilt die Norm nur für die Geräte, die als vollständige Einheit konstruiert und geliefert werden.
Diese Europäische Norm enthält keine Anforderungen an die Qualität des Wassers.

Pompes à chaleur avec compresseur entrainé par moteur électrique - Essais et exigences pour le marquage des appareils pour eau chaude sanitaire

La présente Norme européenne spécifie les méthodes d’essai, le mode d'expression des résultats, ainsi que les exigences de marquage des pompes à chaleur air-eau, eau glycolée-eau, eau-eau et détente directe-eau, équipées d’un compresseur entraîné par un moteur électrique, raccordées ou incluant un réservoir de stockage d'eau chaude domestique. Lorsque ces appareils sont utilisés pour le chauffage de locaux, alors les parties 1 à 4 de l’EN 14511 s'appliquent.
La présente Norme européenne ne comprend que les appareils fabriqués en usine pouvant être raccordés côté air.
La présente Norme européenne ne comprend que les méthodes d’essai destinées au système de pompe à chaleur pour la production d'eau chaude domestique.
NOTE   Les méthodes d’essai applicables simultanément à la production d’eau chaude domestique et au chauffage des locaux ne sont pas traitées dans la présente norme. Le terme « simultané » signifie que la production d'eau chaude domestique et la génération du chauffage des locaux s'effectuent en même temps et peuvent interagir.
Dans le cas d'appareils composés d’éléments séparés, la présente norme ne s'applique qu'aux appareils conçus et fournis comme un ensemble.
La présente Norme européenne ne présente pas d'exigences relatives à la qualité de l'eau.

Toplotne črpalke z električnimi kompresorji - Preskušanje in zahteve za označevanje naprav/enot za gretje (gospodinjske) vode

Ta evropski standard določa metode za preskušanje in poročanje ocenjevanja in določa zahteve za označevanje toplotnih črpalk zrak/voda in voda/voda z električno gnanimi kompresorji, kadar se uporabljajo za gretje (gospodinjske) vode. Kadar so te enote uporabljene za gretje prostora, velja EN 14511, 1–4. del. Ta evropski standard velja za tovarniško izdelane enote, ki se lahko uporabijo v ceveh. Ta evropski standard velja samo za preskusne postopke za sisteme toplotnih črpalk za gretje (gospodinjske) vode.
OPOMBA: Preskusni postopki za istočasno delovanje za gretje (gospodinjske) vode in ogrevanje prostora, niso zajeti v tem standardu. Pri enotah, sestavljenih iz več kosov, standard velja samo za tiste, ki so načrtovani in dostavljeni kot celoten paket.
Ta evropski standard ne vključuje nobenih zahtev po kakovosti vode.

General Information

Status
Withdrawn
Public Enquiry End Date
04-Jan-2009
Publication Date
12-Apr-2011
Withdrawal Date
19-Jan-2017
Technical Committee
I13 - Imaginarni 13
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
20-Jan-2017
Due Date
12-Feb-2017
Completion Date
20-Jan-2017

Relations

Effective Date
01-May-2011
Effective Date
01-May-2011
Effective Date
01-Mar-2017
Effective Date
30-Jul-2011
Effective Date
01-Dec-2008
Standard

SIST EN 16147:2011 - BARVE

English language
35 pages
Preview
Preview
e-Library read for
1 day

Frequently Asked Questions

SIST EN 16147:2011 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Heat pumps with electrically driven compressors - Testing and requirements for marking of domestic hot water units". This standard covers: This European Standard specifies methods for testing and reporting of the rating and it specifies requirements for marking of air/water, brine/water, water/water and direct exchange/water heat pumps with electrically driven compressors connected to or including a domestic hot water storage tank. When these units are used for space heating, then EN 14511 (all parts) applies. In case of air-to-water heat pumps, this European Standard comprises only factory-made units which can be ducted on the airside. This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system. NOTE Testing procedures for simultaneous operation for domestic hot water production and space heating are not treated in this standard. Simultaneous means that domestic hot water production and space heating generation occur at the same time and may interact. In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package. This European Standard does not include any requirement about the quality of water.

This European Standard specifies methods for testing and reporting of the rating and it specifies requirements for marking of air/water, brine/water, water/water and direct exchange/water heat pumps with electrically driven compressors connected to or including a domestic hot water storage tank. When these units are used for space heating, then EN 14511 (all parts) applies. In case of air-to-water heat pumps, this European Standard comprises only factory-made units which can be ducted on the airside. This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system. NOTE Testing procedures for simultaneous operation for domestic hot water production and space heating are not treated in this standard. Simultaneous means that domestic hot water production and space heating generation occur at the same time and may interact. In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package. This European Standard does not include any requirement about the quality of water.

SIST EN 16147:2011 is classified under the following ICS (International Classification for Standards) categories: 23.140 - Compressors and pneumatic machines; 27.080 - Heat pumps; 91.140.65 - Water heating equipment. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 16147:2011 has the following relationships with other standards: It is inter standard links to SIST EN 255-3:2001, SIST EN 255-3:2001/AC:2001, SIST EN 16147:2017, SIST EN 16147:2011/AC:2012, SIST EN 255-3:2001. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.

SIST EN 16147:2011 is associated with the following European legislation: EU Directives/Regulations: 92/75/EEC; Standardization Mandates: M/324. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

You can purchase SIST EN 16147:2011 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of SIST standards.

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Wärmepumpen mit elektrisch angetriebenen Verdichtern - Prüfungen und Anforderungen an die Kennzeichnung von Geräten zum Erwärmen von BrauchwarmwasserPompes à chaleur avec compresseur entrainé par moteur électrique - Essais et exigences pour le marquage des appareils pour eau chaude sanitaireHeat pumps with electrically driven compressors - Testing and requirements for marking of domestic hot water units91.140.65Oprema za ogrevanje vodeWater heating equipment27.080Heat pumps23.140VWURMLCompressors and pneumatic machinesICS:Ta slovenski standard je istoveten z:EN 16147:2011SIST EN 16147:2011en,fr,de01-maj-2011SIST EN 16147:2011SLOVENSKI
STANDARDSIST EN 255-3:2001/AC:2001SIST EN 255-3:20011DGRPHãþD

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 16147
January 2011 ICS 27.080; 27.200 Supersedes EN 255-3:1997English Version
Heat pumps with electrically driven compressors - Testing and requirements for marking of domestic hot water units
Pompes à chaleur avec compresseur entrainé par moteur électrique - Essais et exigences pour le marquage des appareils pour eau chaude sanitaire
Wärmepumpen mit elektrisch angetriebenen Verdichtern - Prüfungen und Anforderungen an die Kennzeichnung von Geräten zum Erwärmen von Brauchwarmwasser This European Standard was approved by CEN on 3 December 2010.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16147:2011: ESIST EN 16147:2011

This document has been prepared by the working group CEN/TC 113/WG 10 "Heat pumps and air conditioners". This standard was submitted to enquiry under the reference prEN 255-3 which has been changed before Formal Vote to FprEN 16147. This European Standard references the document TREN D1 D(2002) M/324 for information on “Water-Heaters, Hot Water Storage Appliances and Water Heating Systems”.
Testing procedures for simultaneous operation for domestic hot water production and space heating are not treated in this standard. In this standard the basis of the measurements are the daily EU-Reference-Tapping-Cycles defined in the mandate M/324. Presently there is no standard fixed for daily cycles for the space heating mode. The following technical and general modifications have been introduced during the revision: − The new COPDHW is smaller than the former COPt of EN 255-3, since heat losses of the hot water storage tank are not considered in the calculation of the COPDHW, whereas the former standard EN 255-3 accounted these losses. − In EN 16147, five different daily tapping profiles (S, M, L, XL, and XXL) for different storage tank sizes can be selected in order to determine the coefficient of performance. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. SIST EN 16147:2011

(IEC 60204-1:2005, modified) EN 60335-2-40, Household and similar electrical appliances — Safety — Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers (IEC 60335-2-40:2002, modified) EN 61000-3-11, Electromagnetic compatibility (EMC) — Part 3-11: Limits — Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems — Equipment with rated current ≤ 75 A and subject to conditional connection (IEC 61000-3-11:2000) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 14511-1:2007 and the following apply. 3.1 heat pump for heating domestic water heat pump as defined in EN 14511-1 connected to or including a domestic hot water storage tank SIST EN 16147:2011

NOTE See Foreword, 10th paragraph, 1st indent. 3.6 reference hot water temperature (θθθθ’WH) temperature determined as the mean value of the average temperatures during one tapping which ends when the hot water temperature is below 40 °C 3.7 maximum volume of usable hot water (Vmax) total volume of hot water with a temperature of 40 °C produced from water at a temperature of not less than 40 °C and cold water at temperature of 10 °C NOTE See 6.6. 3.8 off-peak product product that is designed to fulfill the requirements of the tapping pattern between 7:00 and 22:00 without external energy supply, e.g. to enable operation at off-peak / low-tariff periods 3.9 operating range working range for the heat pump as specified by the manufacturer and covered by full manufacturer warranty 4 Symbols and abbreviations Symbol Description
Units cp Specific heat capacity of water
kJ/(kg*K) nTAP Number of tappings during a tapping cycle
- Pes Standby power input
kW QEL-Tap Calculated heat energy produced by electricity (resistance heater) to reach the required tapping temperature
kWh QEL-TC Calculated heat energy produced by electricity (resistance heater) during the whole tapping cycle
kWh SIST EN 16147:2011
kWh QHP-TC Useful heat energy produced by heat pump during the whole tapping cycle
kWh QTap Total useful heat energy during one tapping
kWh QTC Total useful heat energy during the whole tapping cycle
kWh T Temperature
K t Time
s th Heating up time
s tes Duration of one on-off-cycle (period between the last and second-last switch-off of compressor) of the heat pump to determine the standby power input
s tTAP Time length of one tapping
s tTTC Time period of test cycle in hours
h AirV& Nominal air volume flow rate
m3/s FluidV& Measured liquid volume flow rate
m3/s TapV& Volume flow rate of hot water during tapping
m3/s Vmax Maximum volume of usable hot water
m3 Weh Heating up energy input
kWh WEL-Corr Electrical energy consumption of fans or liquid pumps
kWh WEL-HP-TC Total electrical energy consumption of the heat pump during the whole tapping cycle
kWh WEL-M-TC Measured electrical energy consumption during the whole tapping cycle
kWh WEL-TC Total electrical energy consumption during a tapping cycle
kWh Wes Energy input during the last on-off-cycle (period between the last and second-last switch-off of compressor) to determine the standby power input
kWh ûpext Difference of external static pressure
Pa ûpint Difference of internal static pressure
Pa ûTdesired Set temperature difference between hot water temperature and cold water temperature
K Q, Boundary Temperature at operating range limit
°C WC Cold water temperature
°C WH Hot water temperature
°C SIST EN 16147:2011
°C ρ (T) Density of the hot water depending on the temperature at the flow meter
kg/m3
5 General test requirements 5.1 Test apparatus and uncertainties The test apparatus shall be designed in such a way that all requirements for adjustment of set values, stability criteria and uncertainties of measurement according to this European Standard can be fulfilled. Water systems or other heat transfer liquid systems shall be sufficiently free of entrained gas as to ensure that the measured results are not significantly influenced. The inlet and outlet temperatures of the domestic water are measured in the centre of the flow and as close as possible to the appliance. The response time of the temperature sensor and the sampling interval have to be chosen to maintain the uncertainties in Table 1. Ducted air systems shall be sufficiently airtight to ensure that the measured results are not significantly influenced by exchange of air with the surroundings. The uncertainties of measurement shall not exceed the values specified in Table 1, the permissible deviations shall not exceed the values specified in Table 2. In addition the maximal permissible deviation of thermal energy for the complete tapping cycle shall be less than 5 %.
°C K dm3 dm3/s kWh
± 0,2 K ± 0,2 K ± 2 % ± 2 % ± 5 % Liquid (heat transfer medium)
- temperature
inlet / outlet
- volume flow
- static pressure difference
- brine concentration
°C m3/s Pa
%
± 0,15 K ± 1 % ± 5 Pa (∆p ≤ 100 Pa) ± 5 % (∆p > 100 Pa) ± 2 % Air (heat source)
- dry bulb temperature
- wet bulb temperature
-
volume flow
- static pressure difference
°C
°C
dm3/s
Pa
± 0,2 K ± 0,3 K ± 5 % ± 5 Pa (∆p ≤ 100 Pa) ± 5 % (∆p > 100 Pa) Electrical quantities
- electric power
- electrical energy
- voltage
- current
W kWh V A
± 1 % ± 1 % ± 0,5 % ± 0,5 % SIST EN 16147:2011

Measured quantity Permissible deviation of the arithmetic mean values from set values Permissible deviations of individual measured values from set values Domestic hot water - inlet temperature - volume flow
± 1 K ± 5 %
± 1 K ± 10 % Liquid (heat transfer medium)
- inlet temperature
- outlet temperature
- volume flow a
- static pressure difference a
± 0,2 K ± 0,3 K ± 2 % -
± 0,5 K ± 0,6 K ± 5 % ± 10 % Air
- inlet temperature
(dry bulb/wet bulb)
- ambient temperature
(if not used as heat source)
- volume flow
- static pressure difference
± 0,3 K
± 1 K
± 5 % -
± 1 K
± 2 K
± 10 % ± 10 % Voltage ± 4 % ± 4 % a
Frosting period excluded.
5.2 Test room for the outdoor heat exchanger of air source heat pumps The size of the test room shall be selected to avoid any resistance to air flow at the air inlet and air outlet orifices of the test object. The air flow through the room shall not be capable of initiating any short circuit between the two orifices, and therefore the velocity of air flow at these two locations shall not exceed 1,5 m/s when the test object is switched off. The air velocity in the room shall also not be higher than the mean velocity through the unit inlet. Unless otherwise stated by the manufacturer, the air inlet and air outlet orifices shall not be less than 1 m from the surfaces of the test room; this also applies to any measuring ducts. Any direct heat radiation (e.g. solar radiation) onto heating units in the test room onto the heat pump or onto the temperature measuring points shall be avoided. 5.3 Setting the external static pressure difference on the air side for heat pumps with duct connection 5.3.1 All units The test conditions are given in Table 4 and Table 5. If liquid heat transfer media other than water are used, the specific heat capacity and density of such heat transfer media shall be determined and taken into consideration in the evaluation. Table 2 states permissible deviations of the measured values from the test conditions. 5.3.2 Non ducted units For non ducted units, the adjustable settings such as louvers and fan speed shall be set according to the manufacturer instruction. SIST EN 16147:2011

ratings kW Minimum external static
pressure a
b Pa 0 < Q < 8 25 8 ≤ Q < 12 37 12 ≤ Q < 20 50 20 ≤ Q < 30 62 30 ≤ Q < 45 75 45 ≤ Q < 82 100 82 ≤ Q < 117 125 117 ≤ Q < 147 150 Q ≥ 147 175 a
For equipment tested without an air filter installed, the minimum external static pressure shall be increased by 10 Pa. b
If the manufacturer’s installation instructions state that the maximum allowable discharge duct length is less than 1 m, then the required minimum external static pressure shall be 10 Pa.
5.4 Installation and connection of the heat pump The heat pump shall be installed and connected for the test as recommended by the manufacturer in his installation and operation manual. The accessories provided by option (for example heating element) are not included in the test. Temperature and pressure measuring points shall be arranged in order to obtain significant mean values. Set points for internal control equipment of the unit such as thermostats, pressure switches or mixing valves should be set to the values stated by the manufacturer. SIST EN 16147:2011

Table 4  Test conditions applicable to all systems Measured variable Set value
Power supply voltage
Rated voltage
Power supply frequency
Rated frequency
Air flow rate on the heat source side
Nominal, as indicated by the manufacturer.
When only a range is given, tests are to
be carried out at the maximum value.
Temperature of the incoming cold water (°C)
Hot water flow rate (l/min)
4 or 10 (see Table 6)
temperature in °C Range of ambient temperature of heat pump in °°°°C Ambient temperature of
storage tank
in °°°°C Outside air heat pump
(placed indoor side)
Outside air heat pump (outdoor side)
Indoor air
Exhaust air
Water
Brine
Direct evaporation 7 (6)
7 (6)
15 (12)
20 (12)
10 / 7
0 / -3
from 15 to 30
heat source temperature
heat source temperature
from 15 to 30
from 15 to 30
from 15 to 30
from 15 to 30
20 a All air temperatures are dry-bulb with wet bulb temperatures in brackets. b
Brine mean bath temperature for direct evaporation testing.
6 Performance test and determination of the energy consumption 6.1 General The test methods described in this clause are designed to determine the energy consumption and the performance of heat pump for heating domestic water.
The appliance shall be installed and adjusted in the initial state conditions and in the initial adjustment conditions defined in 5.1. 6.2 Basic principles, scope of the tests The tests consist of the following six principal stages (see Figure 1, Key 1): A heating up period (see 6.3) B determination of standby power input (see 6.4) C determination of the energy consumption and the coefficient of performance for heating domestic water by using the reference tapping cycles (see 6.5). Different tappings in one tapping cycle (see Table 7 to Table 11 and Figure 2) D determination of a reference hot water temperature and the maximum quantity of usable hot water in a single tapping (see 6.6) E test to determine the temperature operating range F safety tests SIST EN 16147:2011

Key (1) cold water temperature Figure 1  Stages and order of the tests All tests are performed with power supplied at the rated voltage and frequency as recommended by the manufacturer. After the initial start of the heat pump the power supply is left on for the duration of the test. For off-peak products, the product of the assembly defined according to the recommendations of the manufacturer shall allow to have no heat generation in the periods indicated in the stage C, whereas the package is under power supply.
To define, during the test th
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...

記事のタイトル:SIST EN 16147:2011 - 電気駆動圧縮機を搭載した熱ポンプ-家庭用湯沸かしユニットのテストと表示要件 記事の内容:この欧州標準は、家庭用お湯に使用される電気駆動圧縮機を搭載した空気/水および水/水熱ポンプの評価および報告方法を示し、表示要件を規定しています。これらのユニットが暖房に使用される場合は、EN 14511, part 1 - 4が適用されます。この欧州標準は、ダクトで接続できる工場製造ユニットに適用されます。この欧州標準は、熱ポンプシステムの家庭用お湯製造のテスト手順にのみ適用されます。注意:家庭用お湯製造と暖房の同時運転に関するテスト手順はこの標準では扱われていません。複数部品から構成されるユニットの場合、この標準は完全なパッケージとして設計され供給される部分にのみ適用されます。また、この標準には水質に関する要件は含まれていません。

The article discusses the SIST EN 16147:2011 European Standard, which outlines methods for testing and reporting the rating, as well as requirements for marking, of air/water and water/water heat pumps with electrically driven compressors used for domestic hot water. The standard applies to factory-made units that can be ducted and focuses on testing procedures for domestic hot water production. It does not address simultaneous operation for both domestic hot water production and space heating. The standard also does not cover requirements for water quality.

기사 제목: SIST EN 16147:2011 - 전기 압축기를 갖춘 열 펌프의 가정용 온수 장비에 대한 테스트와 표시 요구 사항 기사 내용: 이 유럽 표준은 가정용 온수에 사용되는 전기 압축기를 갖춘 공기/물 및 물/물 열 펌프의 등급 측정과 보고에 대한 방법을 명시하며, 표시 요구 사항을 규정합니다. 이 장치들이 난방에 사용되는 경우에는 EN 14511, part 1 - 4가 적용됩니다. 이 유럽 표준은 덕트로 연결될 수 있는 공장 제작 장치에 적용됩니다. 이 유럽 표준은 열 펌프 시스템의 가정용 온수 생산을 위한 테스트 절차에만 해당됩니다. 참고: 가정용 온수 생산 및 난방 작동이 동시에 이루어지는 경우에 대한 테스트 절차는 이 표준에서 다루지 않습니다. 여러 부분으로 구성된 장치의 경우, 이 표준은 완전한 패키지로 설계되고 공급된 부분에만 적용됩니다. 또한, 이 표준은 수질에 대한 요구 사항을 포함하지 않습니다.