Silica fume for concrete - Part 2: Conformity evaluation

This part of EN 13263 specifies the scheme for the evaluation of conformity of silica fume to EN 13263-1, including certification of conformity by a certification body.
This European Standard provides technical rules for production control by the manufacturer, including autocontrol testing of samples, and for the tasks of the certification body. It also provides rules for actions to be followed in the event of non-conformity and the procedure for the certification of conformity.

Silikastaub für Beton - Teil 2: Konformitätsbewertung

Dieser Teil der EN 13263 legt das Verfahren für die Konformitätsbewertung von Silikastaub nach EN 13263 1 fest einschließlich der Zertifizierung der Konformität durch eine Zertifizierungsstelle.
Diese Europäische Norm enthält technische Regeln für die Produktionskontrolle durch den Hersteller, einschließlich der internen Überwachungsprüfungen von Proben, und für die Aufgaben der Zertifizierungs-stelle. Es enthält darüber hinaus Regeln für Maßnahmen, die bei Nichtkonformität zu ergreifen sind, sowie das Verfahren für die Zertifizierung der Konformität.

Fumée de silice pour béton - Partie 2: Evaluation de la conformité

Cette partie de l’EN 13263 spécifie le système d’évaluation de la conformité de la fumée de silice dans l’EN 13263-1,
comprenant la certification de conformité par un organisme de certification.
Cette Norme européenne présente des règles techniques relatives au contrôle de production effectué par le fabricant
(essai d’auto-contrôle des échantillons inclus) et aux tâches de l’organisme de certification. Le document présente
également des règles relatives aux actions à suivre en cas de non-conformité et les modes opératoires de certification
de conformité.

Mikro silika za beton - 2. del: Ovrednotenje skladnosti

General Information

Status
Published
Publication Date
17-May-2009
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
25-Mar-2009
Due Date
30-May-2009
Completion Date
18-May-2009

Relations

Buy Standard

Standard
EN 13263-2:2005+A1:2009
English language
19 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Mikro silika za beton - 2. del: Ovrednotenje skladnostiSilikastaub für Beton - Teil 2: KonformitätsbewertungFumée de silice pour béton - Partie 2: Evaluation de la conformitéSilica fume for concrete - Part 2: Conformity evaluation91.100.30Beton in betonski izdelkiConcrete and concrete productsICS:Ta slovenski standard je istoveten z:EN 13263-2:2005+A1:2009SIST EN 13263-2:2005+A1:2009en,fr,de01-julij-2009SIST EN 13263-2:2005+A1:2009SLOVENSKI
STANDARDSIST EN 13263-2:20051DGRPHãþD



SIST EN 13263-2:2005+A1:2009



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13263-2:2005+A1
March 2009 ICS 91.100.30 Supersedes EN 13263-2:2005English Version
Silica fume for concrete - Part 2: Conformity evaluation
Fumée de silice pour béton - Partie 2: Evaluation de la conformité
Silikastaub für Beton - Teil 2: Konformitätsbewertung This European Standard was approved by CEN on 19 May 2005 and includes Amendment 1 approved by CEN on 8 February 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13263-2:2005+A1:2009: ESIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 2 Contents Page Foreword .31Scope .42Normative references .43Terms and definitions .44Tasks for the manufacturer .84.1Factory production control .84.2Internal quality control .94.3Autocontrol testing of samples . 114.4Further testing of samples . 115Tasks for the certification body . 125.1General . 125.2Surveillance, assessment and acceptance of the factory production control . 125.3Evaluation of the results of autocontrol testing of samples . 125.4Audit testing of samples taken at the production plant/depot and initial type testing . 135.5Initial inspection of the production facilities and the factory production control . 145.6Evaluation of test results during the initial period . 156Actions in the event of non-conformity . 156.1Actions to be taken by the manufacturer . 156.2Actions to be taken by the certification body . 157Procedure for third party certification of conformity . 168Certificate of conformity and conformity mark . 168.1Indication of conformity . 168.2Certificate of conformity . 178.3Conformity mark . 17Bibliography . 19 SIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 3 Foreword This document (EN 13263-2:2005+A1:2009) has been prepared by Technical Committee CEN/TC 104 “Concrete and related products”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2009, and conflicting national standards shall be withdrawn at the latest by September 2009. This document includes Amendment 1, approved by CEN on 2009-02-08. This document supersedes EN 13263-2:2005. The start and finish of text introduced or altered by amendment is indicated in the text by tags !"EN 13263 has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of Part 1 of EN 13263. !EN 13263-2:2005+A1:2009 contains a deletion of the second paragraph of 4.2.2.2." EN 13263 consists of the following parts, under the general title Silica fume for concrete:  Part 1: Definitions, requirements and conformity criteria;  Part 2: Conformity evaluation. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
SIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 4 1 Scope This part of EN 13263 specifies the scheme for the evaluation of conformity of silica fume to EN 13263-1, including certification of conformity by a certification body. This European Standard provides technical rules for production control by the manufacturer, including autocontrol testing of samples, and for the tasks of the certification body. It also provides rules for actions to be followed in the event of non-conformity and the procedure for the certification of conformity. 2 Normative references The following referenced documents are indispensable for the application of this European Standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 196-1, Methods of testing cement — Part 1: Determination of strength EN 196-2, Methods of testing cement — Part 2: Chemical analysis of cement !EN 196-7:2007", Methods of testing cement — Part 7: Methods of taking and preparing samples of cement EN 206-1, Concrete — Part 1: Specification, performance, production and conformity EN 13263-1:2005, Silica fume for concrete — Part 1: Definitions, requirements and conformity criteria 3 Terms and definitions For the purposes of this European Standard, the following terms and definitions apply. 3.1 activity index measurement of the effect of silica fume on the compressive strength of mortar 3.2 allowable probability of acceptance
CR for a given sampling plan, the allowed probability of acceptance of silica fume with a characteristic value outside the specified characteristic value 3.3 autocontrol continuous statistical quality control of the silica fume based on the testing of samples taken by the manufacturer at point(s) of release from the silica fume production plant 3.4 autocontrol testing continual testing by the manufacturer of silica fume spot samples taken at the point(s) of release from the production plant
3.5 certificate of conformity to EN 13263-1 document issued under the rules of a certain scheme for the evaluation of conformity indicating that adequate confidence is provided that a silica fume is in conformity with EN 13263-1 SIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 5 3.6 certification procedure by which a third party gives written assurance that a product, process or service conforms to specified requirements [EN 45020:1998] 3.7 certification body impartial body, governmental or non-governmental, possessing the necessary competence and responsibility to carry out conformity certification according to given rules of procedure and management 3.8 certified silica fume silica fume for which a certificate of conformity (see 3.5) has been issued 3.9 characteristic value value having a prescribed probability of not being attained in a hypothetical unlimited test series [ISO 8930:1987] NOTE Equivalent to "fractile" which is defined in ISO 3534-1. 3.10 conformity mark protected mark applied on the basis of the certificate of conformity (see 3.5) 3.11 control period period of production and dispatch identified for the evaluation of the autocontrol test results 3.12 densified silica fume silica fume that has been treated to increase the bulk density by particle agglomeration, the bulk density typically being above 500 kg/m3 3.13 depot bulk silica fume handling facility – not located at the production plant - used for the dispatch of silica fume – whether in bulk or bagged – after transfer or storage where the manufacturer has full responsibility for all aspects of the quality of the silica fume 3.14 existing production plant production plant which is already producing silica fume under the certification scheme 3.15 factory production control permanent internal control of silica fume production exercised by the manufacturer including internal quality control and autocontrol testing NOTE The required activities are stated in 4.1 to 4.3 in this part of EN 13263. 3.16 further testing of samples testing according to 4.4 in this part of EN 13263 SIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 6 3.17 initial period immediate period after the first issuing of the certificate of conformity for a silica fume (see 5.6.1 in this part of EN 13263 for duration) 3.18 intitial type testing testing of the first audit sample according to 5.4 in this part of EN 13263 3.19 inspection body impartial body having the organization, staffing, competence and integrity to perform according to specified criteria functions such as assessing, recommending for acceptance and subsequent audit of manufacturers´ quality control operations, and selection and evaluation of products on site or in factories or elsewhere, according to specific criteria 3.20 new production plant production plant which is not already producing silica fume under the certification scheme 3.21 production plant facility used by a manufacturer for the production of silica fume: a) silicon metal or silicon alloy production plant; b) processing plant, for example for the selection, slurrifying, blending or densifying of silica fume. 3.22 quality control part of quality management focused on fulfilling quality requirements [EN ISO 9000:2000] 3.23 sampling plan specific plan which states the (statistical) sample size(s) to be used, the percentage Pk on which the characteristic value is based, and the allowable probability of acceptance CR 3.24 silica fume very fine particles of amorphous silicon dioxide collected as a by-product of the smelting process used to produce silicon metal and ferro-silicon alloys NOTE 1 Silica fume may be processed, for example by classification, selection, blending, densifying, or slurrifying, or by a combination of these processes, in adequate production plants. Such processed silica fume may consist of silica fumes from different sources, each conforming to the definition given in this subclause. NOTE 2 Other names used for silica fume are condensed silica fume and microsilica. 3.25 silica fume slurry homogeneous, pH regulated liquid suspension of silica fume in water, typically with a dry content of 50 % by mass, corresponding to about 700 kg of silica fume per m3 of slurry 3.26 single result limit value value of a chemical or physical property which – for any single test result – in the case of an upper limit is not to be exceeded or in the case of a lower limit is, as a minimum, to be reached SIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 7 3.27 specified characteristic value characteristic value of a chemical or physical property which in the case of an upper limit is not to be exceeded or in the case of a lower limit is, as a minimum, to be reached NOTE Conformity with the specified characteristic values in EN 13263-1 is verified by the methods in 7.2 of
EN 13263-1:2005. 3.28 spot sample !sample taken within a short period of time and at a fixed point from within a larger quantity, relating to the intended tests. It can be obtained by combining one or more immediately consecutive increments [EN 196-7:2007]" 3.29 test technical operation that consists of the determination of a characteristic of a product according to a specified procedure [Adapted from EN 45020:1998] 3.30 test cement selected brand of Portland cement of type CEM I, strength class 42,5 N or higher, conforming to EN 197-1 to be used for carrying out the tests needed to evaluate conformity to the requirement of 5.3.3 in EN 13263-1:2005. Test cement is selected by the silica fume manufacturer and is further characterized by its fineness and contents of tricalcium aluminate and alkalis as follows:  Fineness: 300 m2/kg to 400 m2/kg when determined in accordance with EN 196-6;  Tricalcium aluminate: 8 % to 12 % when determined in accordance with EN 196-2;  Alkalis (Na2O eqv): 0,6 % to 1,2 % when determined in accordance with EN 196-2. 3.31 testing laboratory laboratory which measures, examines, tests, calibrates or otherwise determines the characteristics or performance of materials or products 3.32 test method specified technical procedure for performing a test [EN 45020:1998] 3.33 type II addition finely divided inorganic, pozzolanic or latent hydraulic material that may be added to concrete in order to improve certain properties or to achieve special properties, see EN 206-1 3.34 undensified silica fume silica fume taken directly from the collection filter, the bulk density typically being in the range 150 kg/m³ to 350 kg/m3 3.35 works´ quality manual document that provides information on the production control which is applied by a manufacturer at a particular production plant to ensure conformity of the silica fume with the requirements of EN 13263-1 SIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 8 4 Tasks for the manufacturer 4.1 Factory production control 4.1.1 Concept Factory production control means the permanent internal control of silica fume production exercised by the manufacturer and consists of internal quality control (see 4.2) and autocontrol testing of samples of silica fume taken at the point of release (see 4.3). NOTE The requirements of EN 13263-2 as regards production control take account of those clauses of EN ISO 9001 which are relevant to the production, process control and testing of silica fume. 4.1.2 Works´ quality manual The manufacturer's documentation and procedures for production control shall be described in a works´ quality manual, which shall adequately describe, among other things: a) quality aims and the organisational structure, responsibilities and powers of the management with regard to product quality and the means to monitor the achievement of the required product quality and the effective operation of the internal quality control (see 4.1.3); b) manufacturing and quality control techniques, processes and systematic actions that will be used (see 4.2.1, 4.2.3 and 4.3.2); c) inspections and tests that will be carried out before, during and after manufacture, and the frequency with which they will be carried out (see 4.2.2, 4.3.1 and 4.3.3). The works´ quality manual prepared by the manufacturer for each production plant shall include an adequate system of documentation (see 4.1.4 and 4.3.4). The works´ quality manual shall address and document the procedures operated to ensure that the manufactured silica fume conforms to the technical specifications. The manual may reference associated documents which provide further details of the autocontrol testing of samples and the internal quality control. For the purpose of this scheme, the term works´ quality manual shall be considered to include these associated documents. NOTE In the case of an existing quality management system according to EN ISO 9001, the certification body may examine if the corresponding quality manual meets all the requirements of EN 13263-1 which are relevant to the production control of silica fume. Provided all the requirements are included, this quality manual should also be applied for product certification. 4.1.3 Management systems 4.1.3.1 Quality policy statement The works´ quality manual shall include a statement by the management of the manufacturer defining its quality policy, objectives and commitments to the attainment of product quality. 4.1.3.2 Management representative The manufacturer shall appoint a management representative who, irrespective of other responsibilities, shall have defined authority and responsibility for ensuring that the requirements of this part of EN 13263 for the evaluation of conformity are implemented and maintained. SIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 9 4.1.3.3 Internal audits and management review In order to ensure the continuing suitability and effectiveness of the works´ quality manual to meet the requirements of EN 13263-1, the manufacturer shall perform at least once per year: a) internal audits covering the scope of this clause 4 and 6.1; b) manufacturer´s management review of the production control, taking into account records of the internal audits. 4.1.3.4 Training The works´ quality manual shall describe the measures taken to ensure that all the personnel involved in operations that can affect internal quality control and product quality have appropriate experience or training. Appropriate records shall be retained. 4.1.4 System of documentation 4.1.4.1 Document control The management representative of the manufacturer shall be responsible for the control of all documents and data related to production control and to this scheme for the evaluation of conformity. This control shall ensure that the appropriate issues of all documents are available at essential locations, that obsolete documents are withdrawn and that changes or modifications to any document are effectively introduced. A master list shall be established to identify the current version of documents in order to prevent the use of non-applicable documents. 4.1.4.2 Quality records The manufacturer shall retain records of production control for at least the period required to comply with relevant legislation. 4.2 Internal quality control 4.2.1 Process control 4.2.1.1 General The works´ quality manual shall describe the parameters for process planning, process control and testing, inspection, corrective action, verification, dispatch and the associated records. Depending on the installation, the following measures shall be provided: a) in all types of production plants: 1) in-process testing of silica fume properties; 2) silos or tanks of adequate capacity for storage of the silica fume produced allowing a proper identification of the product and giving possibilities of taking spot samples at any time without prior notice; b) additionally, in production plants using processing facilities: 1) separate and adequate storing facilities for the silica fumes to be processed; 2) controlled proportioning of the silica fumes to be processed in order to achieve the target properties of the produced silica fume; SIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 10 3) facilities for adequate homogenization of silica fume; 4) in-process testing of silica fume properties. 4.2.1.2 Provisions for processing plants In production plants for the controlled processing of silica fume, for example by selection, drying, blending, densifying or slurrifying of silica fume, the relevant information on each consignment of incoming silica fume and all operating steps in the process shall be documented in the works´ quality manual by the manufacturer in agreement with the certification body. The following data shall be at least part of this documentation: a) manufacturer and the production location from which the silica fume originates; b) acknowledgement that the silica fume is according to 3.24; c) in case of blending only, the properties of each incoming silica fume shall be controlled on a regular basis in order to be able to achieve the target properties of the silica fume blend. On each incoming silica fume the relevant properties listed in Table 1 of EN 13263-1:2005, except activity index, should be tested by the supplier of the incoming silica fume. The minimum testing frequency should be chosen as indicated in Table 1 of EN 13263-1:2005, "Routine situation", and should be documented in the works´ quality manual. When blending silica fumes from production plants at different locations, each incoming silica fume shall conform to the requirements for silicon dioxide content and specific surface according to EN 13263-1:2005, 5.2.1 and 5.3.1; d) environmental compatibility of the blended silica fume shall be proven, as required by clause 4 of
EN 13263-1:2005; e) densified and undensified silica fume shall not be blended together. 4.2.1.3 Control of off-specification production The works´ quality manual shall contain procedures to ensure that off-specification production is adequately managed. 4.2.2 Measuring and testing 4.2.2.1 Inspection, measuring and test equipment The equipment for in-process inspection and testing shall be regularly checked and calibrated in accordance with the procedures and frequencies laid down in the works´ quality manual. 4.2.2.2 Inspection and test status Procedures for the inspection and test status through the stages of manufacture shall be detailed in the works´ quality manual. These shall include procedures for the control of off-specification intermediate materials. !deleted text" 4.2.3 Handling, storage, packaging and delivery The works´ quality manual shall describe the precautions taken for the protection of the quality of the silica fume while under the responsibility of the manufacturer. It shall include a description of the procedures used at depots. Delivery documentation shall allow traceability to the production plants or depots. SIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 11 4.3 Autocontrol testing of samples 4.3.1 Sampling and testing The manufacturer shall operate a system of autocontrol testing for the certified silica fume. This system shall be used to demonstrate conformity to the requirements in clause 7 of EN 13263-1:2005. The properties to be tested, the testing methods, the minimum frequency of autocontrol testing and the conformity criteria shall be in accordance with the basic requirements given in clause 7 of EN 13263-1:2005. For silica fumes not being dispatched continuously, the frequency of testing and the point of sampling shall be as specified in the works' quality manual. All test data shall be documented. 4.3.2 Corrective action The works´ quality manual shall document procedures for the review and adjustment of the production control in case of non-conformity (see 6.1). The actions taken in the event of non-conformity shall be recorded in a report subject to inspection during the management review. In the event of silica fume yielding a test result not conforming to the single result limit value conformity criteria specified in EN 13263-1, the manufacturer shall immediately determine the affected quantity, take appropriate action to prevent the dispatch of this quantity and inform the affected customer if such silica fume has been released. In addition, the manufacturer shall immediately determine the causes of such non-conformity, take corrective actions and undertake a review of all relevant production control procedures. All such actions and findings shall be appropriately recorded in a report subject to inspection during the management review. NOTE The certification body may require to be kept informed of these actions and findings. 4.3.3 Measuring and test equipment for autocontrol testing The equipment used for autocontrol testing shall be regularly checked and calibrated in accordance with procedures and frequencies laid down in the works´ quality manual. The works´ quality manual shall document procedures to ensure that all personnel involved in autocontrol testing have appropriate experience and training. Appropriate records shall be retained. 4.3.4 Quality records The manufacturer shall retain records of the autocontrol test results and appropriate records on test equipment for at least the period required to comply with relevant legislation. 4.4 Further testing of samples Once in a two-years period the properties listed in EN 13263-1:2005 Table 1 shall be further tested. The results of this further testing shall not be used for the evaluation of conformity according to EN 13263-1:2005, 7.2. NOTE The manufacturer may use this further testing for control of his testing procedures by using other personnel or other equipment or in other ways let the testing deviate from the testing according to 7.1.1, but still be within the requirements of the standard for the test method. If other methods than the reference methods are used for the autocontrol testing (see
EN 13263-1:2005 5.1), the further testing may be used to check the continued equivalence of the test methods. SIST EN 13263-2:2005+A1:2009



EN 13263-2:2005+A1:2009 (E) 12 5 Tasks for the certification body 5.1 General The certification body (see 3.7) has responsibility for three separate functions – certification, inspection and testing. These three functions may be carried out by one body or by more than one body. The inspection function may be carried out by an inspection body (see 3.19) and the testing function by a testing laboratory (see 3.31). Reference to the certification body includes reference to any sub-bodies it has. 5.2 Surveillance, assessment and acceptance of the factory production control 5.2.1 Inspection tasks The inspection tasks include surveillance, assessment and acceptance of the production control operated by the manufacturer. Inspection shall include checking that any major change in the works´ quality manual which is relevant to the production control of silica fume has been reported to the certification body by the manufacturer within one month of its implementation. Inspection shall verify that the production control complies with the requirements as described in clause 4 and has been carried out according to the works´ quality manual. 5.2.2 Frequency of inspections The inspections shall be carried out at least once per year and the certification body shall inform the manufacturer in advance when an inspection is to be made. 5.2.3 Reports Following each inspection, a confidential report shall be prepared and sent to the manufacturer. The manufacturer shall, if appropriate, advise the certification body of any corrective actions taken or planned to be taken following receipt of the report. The certification body shall then make a decision on its final assessment. 5.3 Evaluation of the results of autocontrol testing of samples 5.3.1 Evaluation tasks Surveillance, assessment and acceptance of the production control includes evaluation of the test results of the manufacturer's autocontrol testing to check conformity to the statistical conformity criteria and single result limit values in EN 13263-1. 5.3.2 Number and timing of evaluations The number of evaluations of the results of autocontrol testing of samples shall be at least two per year. The timing of the evaluations should be decided in advance. 5.3.3 Control period The length of the control period for evaluation of
...

Questions, Comments and Discussion