SIST EN 61000-6-7:2015
(Main)Electromagnetic compatibility (EMC) -- Part 6-7: Generic standards - Immunity requirements for equipment intended to perform functions in a safety-related system (functional safety) in industrial locations
Electromagnetic compatibility (EMC) -- Part 6-7: Generic standards - Immunity requirements for equipment intended to perform functions in a safety-related system (functional safety) in industrial locations
This part of IEC 61000 is intended to be used by suppliers when making claims for the
immunity of equipment intended for use in safety-related systems against electromagnetic
disturbances.
This standard should also be used by designers, integrators, installers, and assessors of
safety-related systems to assess the claims made by suppliers. It provides guidance to
product committees.
This part of IEC 61000 applies to electrical and electronic equipment intended for use in
safety-related systems and that is
• intended to comply with the requirements of IEC 61508 and/or other sector-specific
functional safety standards, and
• intended to be operated in industrial locations as described in 3.1.15.
NOTE 1 The final safety-related system is designed by a system integrator (or equivalent) that has the
responsibility to assess the adequacy of the equipment for the particular application. This process is described in
Annex D of IEC/TS 61000-1-2:2008.
The object of this standard is to define immunity test requirements for equipment in relation to
continuous and transient, conducted and radiated disturbances, including electrostatic
discharge. These requirements apply only to functions intended for use in functional safety
applications. Test requirements are specified for each port considered.
NOTE 2 The immunity requirements of this standard do not, however, cover extreme cases, which can occur at
any location, but with an extremely low probability of occurrence. In consequence, a designer of a safety-related
system checks whether the requirements of this standard cover the expected electromagnetic phenomena within
the intended application.
Elektromagnetische Verträglichkeit (EMV) - Teil 6-7: Fachgrundnormen - Störfestigkeitsanforderungen an Geräte und Einrichtungen, die zur Durchführung von Funktionen in sicherheitsbeszogenen Systemen (funktionale Sicherheit) an industriellen Standorten vorgesehen sind
Compatibilité électromagnétique (CEM) - Partie 6-7: Normes génériques - Exigences d'immunité pour les équipements visant à exercer des fonctions dans un système lié à la sécurité (sécurité fonctionnelle) dans des sites industriels
L'IEC 61000-6-7:2014 est destinée à être utilisée par les fournisseurs lorsqu'ils font des déclarations concernant l'immunité d'équipements destinés à être utilisés dans des systèmes relatifs à la sécurité, contre les perturbations électromagnétiques. Il convient également que cette norme soit utilisée par les concepteurs, les intégrateurs, les installateurs et les vérificateurs des systèmes relatifs à la sécurité afin de vérifier les déclarations faites par les fournisseurs. Elle fournit des lignes directrices aux comités de produits. Cette partie de l'IEC 61000 s'applique aux équipements électriques et électroniques destinés à être utilisés dans les systèmes relatifs à la sécurité et qui sont:
- destinés à être conformes aux exigences de l'IEC 61508 et/ou à d'autres normes de sécurité fonctionnelle spécifiques à un secteur;
- et destinés à être exploités dans des sites industriels, comme cela est décrit en 3.1.15. L'objet de la présente norme est de définir les exigences d'essai d'immunité des équipements, en ce qui concerne les perturbations continues et transitoires, conduites et rayonnées, y compris les décharges électrostatiques. Ces exigences ne s'appliquent qu'aux fonctions destinées à être utilisées dans des applications de sécurité fonctionnelle. Les exigences d'essai sont spécifiées pour chaque accès considéré.
Elektromagnetna združljivost (EMC) - 6-7. del: Osnovni standardi - Zahteve za odpornost opreme, namenjene za opravljanje funkcij, povezanih z varnostjo (funkcijska varnost), v industrijskih okoljih
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61000-6-7:2015
01-julij-2015
Elektromagnetna združljivost (EMC) - 6-7. del: Osnovni standardi - Zahteve za
odpornost opreme, namenjene za opravljanje funkcij, povezanih z varnostjo
(funkcijska varnost), v industrijskih okoljih
Electromagnetic compatibility (EMC) -- Part 6-7: Generic standards - Immunity
requirements for equipment intended to perform functions in a safety-related system
(functional safety) in industrial locations
Ta slovenski standard je istoveten z: EN 61000-6-7:2015
ICS:
33.100.20 Imunost Immunity
SIST EN 61000-6-7:2015 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 61000-6-7:2015
---------------------- Page: 2 ----------------------
SIST EN 61000-6-7:2015
EUROPEAN STANDARD EN 61000-6-7
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2015
ICS 33.100.20
English Version
Electromagnetic compatibility (EMC) - Part 6-7: Generic
standards - Immunity requirements for equipment intended to
perform functions in a safety-related system (functional safety) in
industrial locations
(IEC 61000-6-7:2014)
Compatibilité électromagnétique (CEM) - Partie 6-7: Elektromagnetische Verträglichkeit (EMV) - Teil 6-7:
Normes génériques - Exigences d'immunité pour les Fachgrundnormen - Störfestigkeitsanforderungen an Geräte
équipements visant à exercer des fonctions dans un und Einrichtungen, die zur Durchführung von Funktionen in
système lié à la sécurité (sécurité fonctionnelle) dans des sicherheitsbeszogenen Systemen (funktionale Sicherheit)
sites industriels an industriellen Standorten vorgesehen sind
(IEC 61000-6-7:2014) (IEC 61000-6-7:2014)
This European Standard was approved by CENELEC on 2014-11-13. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61000-6-7:2015 E
---------------------- Page: 3 ----------------------
SIST EN 61000-6-7:2015
EN 61000-6-7:2015 - 2 -
Foreword
The text of document 77/462/FDIS, future edition 1 of IEC 61000-6-7, prepared by IEC/TC 77
"Electromagnetic compatibility" was submitted to the IEC-CENELEC parallel vote and approved by
CENELEC as EN 61000-6-7:2015.
The following dates are fixed:
(dop) 2015-11-08
• latest date by which the document has to be implemented at
national level by publication of an identical national
standard or by endorsement
(dow) 2017-11-13
• latest date by which the national standards conflicting with
the document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61000-6-7:2014 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60204-1:2005 and NOTE Harmonized as EN 60204-1:2006 (modified) and
A1:2008 EN 60204-1:2009/A1:2009 (not modified)
IEC 61000-6-2:2005 NOTE Harmonized as EN 61000-6-2:2005 (not modified).
IEC 61326-1:2012 NOTE Harmonized as EN 61326-1:2013 (not modified).
IEC 61508-2 NOTE Harmonized as EN 61508-2.
IEC 61508-4:2010 NOTE Harmonized as EN 61508-4:2010 (not modified).
IEC 61511 NOTE Harmonized in EN 61511 series (not modified).
IEC 61784-3 NOTE Harmonized in EN 61784-3 series (not modified).
IEC 62061:2005 NOTE Harmonized as EN 62061:2005 (not modified).
ISO 13849-1:2006 NOTE Harmonized as EN 13849-1:2008 (not modified).
ISO 13849-2:2012 NOTE Harmonized as EN 13849-2:2012 (not modified).
---------------------- Page: 4 ----------------------
SIST EN 61000-6-7:2015
- 3 - EN 61000-6-7:2015
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod),
the relevant EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is
available here: www.cenelec.eu.
Publication Year Title EN/HD Year
IEC 60050 series International Electrotechnical Vocabulary - -
IEC/TS 61000-1-2 2008 Electromagnetic compatibility (EMC) - - -
Part 1-2: General - Methodology for the
achievement of functional safety of
electrical and electronic systems including
equipment with regard to electromagnetic
phenomena
IEC 61000-1-6 2012 Electromagnetic compatibility (EMC) - - -
Part 1-6: General - Guide to the
assessment of measurement uncertainty
IEC 61000-4-2 - Electromagnetic compatibility (EMC) - EN 61000-4-2 -
Part 4-2: Testing and measurement
techniques - Electrostatic discharge
immunity test
IEC 61000-4-3 - Electromagnetic compatibility (EMC) - EN 61000-4-3 -
Part 4-3: Testing and measurement
techniques - Radiated, radio-frequency,
electromagnetic field immunity test
IEC 61000-4-4 - Electromagnetic compatibility (EMC) - EN 61000-4-4 -
Part 4-4: Testing and measurement
techniques - Electrical fast transient/burst
immunity test
IEC 61000-4-5 - Electromagnetic compatibility (EMC) - EN 61000-4-5 -
Part 4-5: Testing and measurement
techniques - Surge immunity test
IEC 61000-4-6 - Electromagnetic compatibility (EMC) - EN 61000-4-6 -
Part 4-6: Testing and measurement
techniques - Immunity to conducted
disturbances, induced by radio-frequency
fields
---------------------- Page: 5 ----------------------
SIST EN 61000-6-7:2015
EN 61000-6-7:2015 - 4 -
Publication Year Title EN/HD Year
IEC 61000-4-8 - Electromagnetic compatibility (EMC) - EN 61000-4-8 -
Part 4-8: Testing and measurement
techniques - Power frequency magnetic
field immunity test
IEC 61000-4-11 - Electromagnetic compatibility (EMC) - EN 61000-4-11 -
Part 4-11: Testing and measurement
techniques - Voltage dips, short
interruptions and voltage variations
immunity tests
IEC 61000-4-16 - Electromagnetic compatibility (EMC) - EN 61000-4-16 -
Part 4-16: Testing and measurement
techniques - Test for immunity to
conducted, common mode disturbances in
the frequency range 0 Hz to 150 kHz
IEC 61000-4-29 - Electromagnetic compatibility (EMC) - EN 61000-4-29 -
Part 4-29: Testing and measurement
techniques - Voltage dips, short
interruptions and voltage variations on d.c.
input power port immunity tests
IEC 61000-4-34 - Electromagnetic compatibility (EMC) - EN 61000-4-34 -
Part 4-34: Testing and measurement
techniques - Voltage dips, short
interruptions and voltage variations
immunity tests for equipment with mains
current more than 16 A per phase
IEC 61508 series Functional safety of EN 61508 series
electrical/electronic/programmable
electronic safety-related systems
IEC 61784-3 - Industrial communication networks - EN 61784-3 -
Profiles -
Part 3: Functional safety fieldbuses -
General rules and profile definitions
IEC Guide 107 - Electromagnetic compatibility - Guide to - -
the drafting of electromagnetic compatibility
publications
---------------------- Page: 6 ----------------------
SIST EN 61000-6-7:2015
IEC 61000-6-7
®
Edition 1.0 2014-10
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
GENERIC EMC STANDARD
NORME GÉNÉRIQUE EN CEM
Electromagnetic compatibility (EMC) –
Part 6-7: Generic standards – Immunity requirements for equipment intended
to perform functions in a safety-related system (functional safety) in industrial
locations
Compatibilité électromagnétique (CEM) –
Partie 6-7: Normes génériques – Exigences d'immunité pour les équipements
visant à exercer des fonctions dans un système lié à la sécurité (sécurité
fonctionnelle) dans des sites industriels
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
PRICE CODE
INTERNATIONALE
CODE PRIX U
ICS 33.100.20 ISBN 978-2-8322-1880-8
Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.
® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale
---------------------- Page: 7 ----------------------
SIST EN 61000-6-7:2015
– 2 – IEC 61000-6-7:2014 IEC 2014
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope and object . 7
2 Normative references . 7
3 Terms, definitions and abbreviations . 8
3.1 Terms and definitions . 8
3.2 Abbreviations . 12
4 General . 13
4.1 Conformance to IEC Guide 107 . 13
4.2 Conformance to IEC/TS 61000-1-2 . 13
4.3 Strategy for the availability of functions intended for safety applications . 14
5 Performance criteria . 14
5.1 Performance criterion for functional safety applications . 14
5.2 Application of the performance criterion DS . 15
6 Test plan . 15
6.1 General . 15
6.2 Configuration of EUT during testing . 15
6.2.1 General . 15
6.2.2 Composition of EUT . 16
6.2.3 Assembly of EUT . 16
6.2.4 I/O ports . 16
6.2.5 Auxiliary equipment . 16
6.2.6 Cabling and earthing (grounding) . 16
6.3 Operational conditions of EUT during testing . 16
6.3.1 Modes . 16
6.3.2 Environmental conditions . 16
6.3.3 EUT application software during test . 16
6.4 Specification of functional performance . 17
6.5 Test description . 17
6.6 Test performance . 17
6.6.1 General . 17
6.6.2 Aspects to be considered during application of DS . 17
7 Immunity requirements . 18
8 Test setup and test philosophy . 25
8.1 Test setup . 25
8.2 Test philosophy. 26
8.3 Test configuration . 26
8.4 Monitoring . 27
9 Test results and test report . 27
Annex A (informative) Strategy for functions intended for safety applications . 28
Bibliography . 29
Figure 1 – Equipment ports . 11
---------------------- Page: 8 ----------------------
SIST EN 61000-6-7:2015
IEC 61000-6-7:2014 IEC 2014 – 3 –
Table 1 – Reaction of EUT during test . 18
Table 2 – Immunity test requirements for equipment – Enclosure port . 19
Table 3 – Immunity test requirements for equipment – Input and output AC power
ports . 20
Table 4 – Immunity test requirements for equipment –Input and output DC power ports . 21
Table 5 – Immunity test requirements for equipment – I/O signal/control ports . 22
Table 6 – Immunity test requirements for equipment – I/O signal/control ports
connected directly to AC power supply networks (including functional earth ports) . 23
Table 7 – General frequency ranges for mobile transmitters and ISM equipment for
radiated tests . 24
Table 8 – General frequency ranges for mobile transmitters and ISM for conducted
tests . 25
Table 9 – Applicable performance criteria and observed behaviour during test for
equipment within the scope that is intended for use in safety-related systems . 26
---------------------- Page: 9 ----------------------
SIST EN 61000-6-7:2015
– 4 – IEC 61000-6-7:2014 IEC 2014
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ELECTROMAGNETIC COMPATIBILITY (EMC) –
Part 6-7: Generic standards – Immunity requirements
for equipment intended to perform functions in a safety-related
system (functional safety) in industrial locations
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61000-6-7 has been prepared by TC 77: Electromagnetic
compatibility.
The text of this standard is based on the following documents:
FDIS Report on voting
77/462/FDIS 77/468//RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
---------------------- Page: 10 ----------------------
SIST EN 61000-6-7:2015
IEC 61000-6-7:2014 IEC 2014 – 5 –
A list of all parts in the IEC 61000 series, published under the general title Electromagnetic
compatibility (EMC), can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
---------------------- Page: 11 ----------------------
SIST EN 61000-6-7:2015
– 6 – IEC 61000-6-7:2014 IEC 2014
INTRODUCTION
IEC 61000 is published in separate parts according to the following structure:
Part 1: General
General considerations (introduction, fundamental principles)
Definitions, terminology
Part 2: Environment
Description of the environment
Classification of the environment
Compatibility levels
Part 3: Limits
Emission limits
Immunity limits (insofar as they do not fall under the responsibility of the product
committees)
Part 4: Testing and measurement techniques
Measurement techniques
Testing techniques
Part 5: Installation and mitigation guidelines
Installation guidelines
Mitigation methods and devices
Part 6: Generic standards
Part 9: Miscellaneous
Each part is further subdivided into several parts, published either as International Standards
or technical reports, some of which have already been published as sections. Others will be
published with the part number followed by a dash and completed by a second number
identifying the subdivision (example: IEC 61000-3-11).
---------------------- Page: 12 ----------------------
SIST EN 61000-6-7:2015
IEC 61000-6-7:2014 IEC 2014 – 7 –
ELECTROMAGNETIC COMPATIBILITY (EMC) –
Part 6-7: Generic standards – Immunity requirements
for equipment intended to perform functions in a safety-related
system (functional safety) in industrial locations
1 Scope and object
This part of IEC 61000 is intended to be used by suppliers when making claims for the
immunity of equipment intended for use in safety-related systems against electromagnetic
disturbances.
This standard should also be used by designers, integrators, installers, and assessors of
safety-related systems to assess the claims made by suppliers. It provides guidance to
product committees.
This part of IEC 61000 applies to electrical and electronic equipment intended for use in
safety-related systems and that is
• intended to comply with the requirements of IEC 61508 and/or other sector-specific
functional safety standards, and
• intended to be operated in industrial locations as described in 3.1.15.
NOTE 1 The final safety-related system is designed by a system integrator (or equivalent) that has the
responsibility to assess the adequacy of the equipment for the particular application. This process is described in
Annex D of IEC/TS 61000-1-2:2008.
The object of this standard is to define immunity test requirements for equipment in relation to
continuous and transient, conducted and radiated disturbances, including electrostatic
discharge. These requirements apply only to functions intended for use in functional safety
applications. Test requirements are specified for each port considered.
NOTE 2 The immunity requirements of this standard do not, however, cover extreme cases, which can occur at
any location, but with an extremely low probability of occurrence. In consequence, a designer of a safety-related
system checks whether the requirements of this standard cover the expected electromagnetic phenomena within
the intended application.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60050 (all parts), International Electrotechnical Vocabulary (IEV) (available at
www.electropedia.org)
IEC/TS 61000-1-2:2008, Electromagnetic compatibility (EMC) – Part 1-2: General –
Methodology for the achievement of functional safety of electrical and electronic systems
including equipment with regard to electromagnetic phenomena
IEC 61000-1-6:2012, Electromagnetic compatibility (EMC) – Part 1-6: General – Guide to the
assessment of measurement uncertainty
---------------------- Page: 13 ----------------------
SIST EN 61000-6-7:2015
– 8 – IEC 61000-6-7:2014 IEC 2014
IEC 61000-4-2, Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement
techniques – Electrostatic discharge immunity test
IEC 61000-4-3, Electromagnetic compatibility (EMC) – Part 4-3: Testing and measurement
techniques – Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4, Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement
techniques – Electrical fast transient/burst immunity test
IEC 61000-4-5, Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement
techniques – Surge immunity test
IEC 61000-4-6, Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement
techniques – Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8, Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement
techniques – Power frequency magnetic field immunity test
IEC 61000-4-11, Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement
techniques – Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-4-16, Electromagnetic compatibility (EMC) – Part 4-16: Testing and measurement
techniques – Test for immunity to conducted, common mode disturbances in the frequency
range 0 Hz to 150 kHz
IEC 61000-4-29, Electromagnetic compatibility (EMC) – Part 4-29: Testing and measurement
techniques – Voltage dips, short interruptions and voltage variations on d.c. input power port
immunity tests
IEC 61000-4-34, Electromagnetic compatibility (EMC) – Part 4-34: Testing and measurement
techniques – Voltage dips, short interruptions and voltage variations immunity tests for
equipment with mains current more than 16 A per phase
IEC 61508 (all parts), Functional safety of electrical/electronic/programmable electronic
safety-related systems
IEC 61784-3, Industrial communication networks – Profiles – Part 3: Functional safety
fieldbuses – General rules and profile definitions
IEC Guide 107, Electromagnetic compatibility – Guide to the drafting of electromagnetic
compatibility publications
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 60050-161, as well
as the following apply.
NOTE Other definitions, not included in IEC 60050-161 and in this standard, but nevertheless necessary for the
application of the different tests, are given in the EMC basic publications of the IEC 61000 series.
3.1.1
auxiliary equipment
AE
equipment necessary to provide the equipment under test (EUT) with the signals required for
normal operation and equipment to verify the performance of the EUT
---------------------- Page: 14 ----------------------
SIST EN 61000-6-7:2015
IEC 61000-6-7:2014 IEC 2014 – 9 –
3.1.2
dangerous failure
failure of an element and/or subsystem and/or system that plays a part in implementing the
safety function that:
a) prevents a safety function from operating when required (demand mode) or causes a
safety function to fail (continuous mode) such that the EUC (equipment under control) is
put into a hazardous or potentially hazardous state; or
b) decreases the probability that the safety function operates correctly when required
[SOURCE: IEC 61508-4:2010, 3.6.7]
3.1.3
DC distribution network
local DC electricity supply network in the infrastructure of a certain site or building intended
for connection of any type of DC-powered equipment
Note 1 to entry: Connection to a local or remote battery/power supply/PELV/SELV/UPS is not regarded as a DC
distribution network if such a link comprises only the power source mentioned above for a single piece of
equipment. These lines are considered as signal lines.
3.1.4
electrical/electronic/programmable electronic
E/E/PE
based on electrical (E) and/or electronic (E) and/or programmable electronic (PE) technology
EXAMPLE Electrical/electronic/programmable electronic devices include
– electro-mechanical devices (electrical);
– solid-state non-programmable electronic devices (electronic);
– electronic devices based on computer technology (programmable electronic);
Note 1 to entry: The term is
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.