SIST EN IEC 61000-4-29:2026
(Main)Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
- Abstract
This part of IEC 61000 defines test methods for immunity to voltage dips, short interruptions and voltage variations at the DC input power port of electrical or electronic equipment.
This document is applicable to equipment and systems whose DC input power ports are intended to be connected to low voltage DC networks external to the equipment and systems.
The object of this document is to establish a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or
voltage variations on DC input power ports.
This document defines:
– the range of test levels;
– the test generator;
– the test set-up;
– the test procedure.
The test described hereinafter applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the equipment under test’s (EUT) rated power is greater than the test generator capacity specified in Clause 6.
The ripple at the DC input power port is not included in the scope of this document. It is covered by IEC 61000-4-17.
This document does not specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.
- Status
- Published
- Public Enquiry End Date
- 09-Apr-2026
- Publication Date
- 08-Nov-2026
- Technical Committee
- EMC - Electromagnetic compatibility
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 17-Sep-2026
- Due Date
- 22-Nov-2026
- Completion Date
- 09-Nov-2026
SIST EN IEC 61000-4-29:2026 is the SIST adoption of IEC 61000-4-29 for electromagnetic compatibility (EMC) immunity testing at a d.c. input power port. It specifies how to test electrical and electronic equipment and systems for voltage dips, short interruptions, and voltage variations on d.c. input power ports. Engineers, test laboratories, product committees, and manufacturers use it to choose test levels, configure the generator, run reproducible tests, and record the results.
What does SIST EN IEC 61000-4-29:2026 specify?
SIST EN IEC 61000-4-29:2026 defines a common test method for immunity of equipment connected to low-voltage DC networks external to the equipment. It covers the test levels, the test generator, the test set-up, and the test procedure.
The document is organized into these main clauses: Scope, Normative references, Terms and definitions, General, Test levels, Test generator, Test set-up, Test procedure, Evaluation of test results, and Test report. It also includes three annexes that add examples, a normative measurement method, and background on the DC network.
It excludes ripple on the DC input power port, which is covered by IEC 61000-4-17. It also notes that transient overvoltages caused by faults in the DC distribution system are outside its coverage. The document is a basic reference for product committees, which still decide which tests and severity levels suit their equipment.
| Annex | What it covers |
|---|---|
| Annex A | Informative examples of test generators and test set-up |
| Annex B | Normative inrush current measurement, including generator drive capability and EUT peak inrush current |
| Annex C | Informative description of the DC network |
What are the key requirements of SIST EN IEC 61000-4-29:2026?
SIST EN IEC 61000-4-29:2026 is built around a few practical choices that matter in the lab: which rated voltage to use, which disturbance levels to apply, how the generator must behave, and how to judge and report the result.
Reference voltage and test levels
- Clause 5 uses the equipment rated voltage (U_T) as the reference for test levels.
- If the EUT has a rated voltage range, the document gives a rule for when one voltage can be used and when both ends of the range shall be tested.
- Tables 1 to 3 give preferred levels and durations for voltage dips, short interruptions, and voltage variations.
- Product standards may choose one or more values from those tables, and the document notes that the shortest duration should be tested.
In practice, this means the user does not invent a disturbance profile from scratch. The product standard or test plan selects the relevant severities from the preferred set, so the same equipment can be tested consistently in different labs.
Generator performance
- Clause 6 requires the generator to operate in continuous mode and to produce the intended dips, interruptions, and variations without adding disturbances that affect the EUT.
- The generator output voltage range can go up to 120% of the maximum (U_T).
- The output voltage tolerance is ±5% of (U_T), ripple is less than 1%, rise and fall time is between 0.5 µs and 50 µs, and overshoot or undershoot is less than 10% of the voltage change.
- The generator steady-state output current shall be at least 120% of the EUT rated input current.
In practice, this tells the test lab what the source must be able to deliver before the test can be considered valid. If the source cannot meet the generator requirements, the disturbance may not represent the intended condition.
Low impedance and high impedance conditions
- For short interruptions, the generator shall operate either in low impedance condition, where it can absorb reverse current, or in high impedance condition, where it blocks reverse current.
- For dips and voltage variations, the generator shall operate in low impedance condition.
- In low impedance condition, the peak inrush current capability has minimum values linked to (U_T), and lower capability is allowed only when the verification conditions are satisfied.
- In high impedance condition, the output impedance during interruption shall be at least 100 kΩ.
In practice, this distinction matters because some DC systems behave like a stiff source and others like a disconnected source. The test must match the intended network behavior, especially where the load can push current back into the source.
Verifying the generator
- Clause 6.3 requires verification of the generator characteristics with measurement uncertainty better than ±2%.
- Output voltage is verified in no-load and load conditions at specified voltage points.
- Switching characteristics are checked with a 100 Ω resistive load.
- Duration accuracy is verified for 1 ms and 1 s, within ±5% or ±100 µs, whichever is larger.
In practice, this section is what makes the method repeatable. It gives the lab a way to prove the generator actually delivers the disturbance that the test claims to apply.
Test execution, evaluation, and reporting
- Clause 7 requires the shortest power supply cable specified by the EUT operating instructions, or the shortest practical cable if none is specified.
- Clause 8 requires normal operating conditions, a written test plan, and monitoring of the generator output during the test.
- Voltage dips and short interruptions are applied as three events with at least 10 s between events, and voltage variations are also applied three times at 10 s intervals.
- Clause 9 classifies outcomes from normal operation to unrecoverable loss of function or data.
- Clause 10 requires a test report detailed enough to reproduce the test, including EUT identification, test equipment, performance criteria, observed effects, and special use conditions.
In practice, these clauses turn the immunity check into a traceable engineering record, not just a pass/fail statement.
Annex B inrush current measurement
Annex B is normative and gives the method for measuring test generator peak inrush current drive capability and EUT peak inrush current. It specifies the capacitor load, the bleeder resistor, discharge time between tests, and the measurement circuit. It also gives a procedure for cold start and restart measurements on the EUT, which matters when a reduced-capability generator is used.
What terms does SIST EN IEC 61000-4-29:2026 define?
- Immunity - the ability of a device, equipment, or system to keep working without degradation in the presence of an electromagnetic disturbance.
- Voltage dip - a sudden reduction of voltage at a point in a low-voltage DC distribution system, followed by recovery after a short time.
- Short interruption - a supply-voltage change below 20% of nominal voltage for a time interval that typically does not exceed 1 min.
- Voltage variation - a gradual change of supply voltage from rated voltage down to a lower value and then back up.
- Malfunction - loss of the intended function, or unintended operation, of the equipment.
- DC - Direct Current.
- EUT - Equipment Under Test.
Who uses SIST EN IEC 61000-4-29:2026?
SIST EN IEC 61000-4-29:2026 is used by EMC test laboratories, product committees, equipment manufacturers, and verification engineers who need a reproducible immunity test for DC input power ports. It is also relevant to quality managers and buyers who review EMC test plans or reports for acceptance of equipment.
The document is especially relevant for equipment and systems intended for low-voltage DC networks, including modules or subsystems when the full EUT exceeds the generator capacity. Annex C places the context in industrial DC networks, including battery systems, converters, renewable sources, and other LVDC industrial applications.
What changed in SIST EN IEC 61000-4-29:2026 from the previous edition?
SIST EN IEC 61000-4-29:2026 is the second edition and replaces the first edition published in 2000. The document states these significant technical changes:
- increased test generator output voltage to reflect new DC network voltages
- added tolerances for the duration of voltage changes
- limited current when applying short interruptions in low impedance condition
- clarified generator specifications and their verification
- clarified the loads used to verify switching characteristics and peak inrush current drive capability
- clarified evaluation of test results and test reports
- added a description of the DC environment
Which standards are used with SIST EN IEC 61000-4-29:2026?
SIST EN IEC 61000-4-29:2026 is used alongside several IEC documents that appear in the body, annexes, or bibliography:
- IEC 61000-4-17 - covers ripple on d.c. input power ports, which this document excludes from scope.
- IEC 61000-4-11 - provides a similar circuit reference in Annex B for inrush current measurement.
- IEC 60050(161) - supplies the immunity definition used in Clause 3.
- IEC 60038:2021 - provides standard voltages, useful background for rated-voltage discussions.
- IEC SRD 63317:2025 - describes LVDC industry applications and the industrial DC network context used in Annex C.
What does the SIST EN IEC 61000-4-29:2026 document contain?
The document contains three preferred-level tables for dips, interruptions, and voltage variations, plus waveform figures that show how the disturbances are shaped in time. Clause 6 and Annex B provide the generator performance targets and the verification circuits used for inrush current and output-impedance checks.
Clause 7 gives the test set-up rules, while Clause 8 sets out the laboratory conditions, execution sequence, and special cases for high and low impedance interruption tests. Clause 9 defines how to classify the EUT response, and Clause 10 lists the report items needed for reproducible EMC testing.
Annex A gives example generator arrangements, including a two-source switch configuration and a single programmable power supply arrangement. Annex B gives the measurement method and circuit details for inrush current, and Annex C explains the DC network background that motivates the test method.
Relations
- Effective Date
- 01-Dec-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
- Effective Date
- 15-Sep-2026
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN IEC 61000-4-29:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests". This standard covers: This part of IEC 61000 defines test methods for immunity to voltage dips, short interruptions and voltage variations at the DC input power port of electrical or electronic equipment. This document is applicable to equipment and systems whose DC input power ports are intended to be connected to low voltage DC networks external to the equipment and systems. The object of this document is to establish a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or voltage variations on DC input power ports. This document defines: – the range of test levels; – the test generator; – the test set-up; – the test procedure. The test described hereinafter applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the equipment under test’s (EUT) rated power is greater than the test generator capacity specified in Clause 6. The ripple at the DC input power port is not included in the scope of this document. It is covered by IEC 61000-4-17. This document does not specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.
This part of IEC 61000 defines test methods for immunity to voltage dips, short interruptions and voltage variations at the DC input power port of electrical or electronic equipment. This document is applicable to equipment and systems whose DC input power ports are intended to be connected to low voltage DC networks external to the equipment and systems. The object of this document is to establish a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or voltage variations on DC input power ports. This document defines: – the range of test levels; – the test generator; – the test set-up; – the test procedure. The test described hereinafter applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the equipment under test’s (EUT) rated power is greater than the test generator capacity specified in Clause 6. The ripple at the DC input power port is not included in the scope of this document. It is covered by IEC 61000-4-17. This document does not specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.
SIST EN IEC 61000-4-29:2026 is classified under the following ICS (International Classification for Standards) categories: 33.100.20 - Immunity. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN IEC 61000-4-29:2026 has the following relationships with other standards: It is inter standard links to SIST EN 61000-4-29:2003, SIST EN IEC 62984-1:2021, SIST EN IEC 62003:2020, SIST EN 1776:2016, SIST EN 1776:2026, SIST EN 12645:2014, SIST EN IEC 60079-29-0:2026, SIST EN 60987:2015, SIST EN 62271-1:2018, SIST EN IEC 60947-5-3:2026, SIST EN 50270:2015, SIST EN IEC 60143-4:2024, SIST EN 60987:2010, SIST EN IEC 60947-10:2026, SIST EN 12405-2:2013. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN IEC 61000-4-29:2026 is associated with the following European legislation: EU Directives/Regulations: 2014/30/EU; Standardization Mandates: M/490. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN IEC 61000-4-29:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and abbreviated terms
- 3.1 Terms and definitions
- 3.1.1 immunity (to a disturbance)
- 3.1.2 voltage dip
- 3.1.3 short interruption
- 3.1.4 voltage variation
- 3.1.5 malfunction
- 3.2 Abbreviated terms
- 4 General
- 5 Test levels
- 6 Test generator
- 6.1 General
- 6.2 Characteristics and performances of the generator
- 6.3 Verification of the characteristics of the generator
- 7 Test set-up
- 8 Test procedure
- 8.1 General
- 8.2 Laboratory reference conditions
- 8.3 Execution of the test
- 9 Evaluation of test results
- 10 Test report
- Annex A
- Annex B
- Annex C
- Bibliography
INTRODUCTION IEC 61000 is published in separate parts according to the following structure:
Part 1: General General considerations (introduction, fundamental principles) Definitions, terminology Part 2: Environment Description of the environment Classification of the environment Compatibility levels Part 3: Limits Emission limits Immunity limits (in so far as they do not fall under the responsibility of the product committees) Part 4: Testing and measurement techniques Measurement techniques Testing techniques Part 5: Installation and mitigation guidelines Installation guidelines Mitigation methods and devices Part 6: Generic standards Part 9: Miscellaneous Each part is further subdivided into several parts, published either as international standards or as technical specifications or technical reports, some of which have already been published as sections. Others will be published with the part number followed by a dash and a second number identifying the subdivision (example: IEC 61000-6-1).
This part is an international standard which gives immunity requirements for testing DC equipment and systems with voltage dips, interruptions and variations on the DC input power port.
SIST EN IEC 61000-4-29:2026
1 Scope
This part of IEC 61000 defines test methods for immunity to voltage dips, short interruptions and voltage variations at the DC input power port of electrical or electronic equipment. This document is applicable to equipment and systems whose DC input power ports are intended to be connected to low voltage DC networks external to the equipment and systems. The object of this document is to establish a common and reproducible basis for testing electrical and electronic equipment when subjected to voltage dips, short interruptions or voltage variations on DC input power ports.
This document defines:
- the range of test levels;
- the test generator;
- the test set-up;
- the test procedure.
The test described hereinafter applies to electrical and electronic equipment and systems. It also applies to modules or subsystems whenever the equipment under test’s (EUT) rated power is greater than the test generator capacity specified in Clause 6. The ripple at the DC input power port is not included in the scope of this document. It is covered by IEC 61000-4-17.
This document does not specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to IEC product committees. These product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.
2 Normative references
There are no normative references in this document.
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the following terms and definitions apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- IEC Electropedia: available at https://www.electropedia.org/
- ISO Online browsing platform: available at https://www.iso.org/obp
3.1.1 immunity (to a disturbance)
ability of a device, equipment or system to perform without degradation in the presence of an electromagnetic disturbance [SOURCE: IEC 60050-161:1990, 161-01-20]
SIST EN IEC 61000-4-29:2026
3.1.2 voltage dip
sudden reduction of the voltage at a point in the low voltage DC distribution system, followed by voltage recovery after a short period of time, from a few milliseconds up to a few seconds
3.1.3 short interruption
change of the supply voltage at a point of the low voltage DC distributed system below 20 % of the nominal voltage for a time interval which typically does not exceed 1 min Note 1 to entry: A short interruption does not necessarily result in a complete disappearance of the supply voltage.
3.1.4 voltage variation
gradual change of the supply voltage from the rated voltage to a lower voltage or from the rated voltage to a higher voltage
3.1.5 malfunction
termination of the ability of an equipment to carry out intended functions, or the execution of unintended functions by the equipment
3.2 Abbreviated terms
DC Direct current ESR Equivalent series resistance EUT Equipment under test LVDC Low-voltage direct current
4 General
The operation of electrical or electronic equipment can be affected by voltage dips, short interruptions or voltage variations of the power supply.
Voltage dips and short interruptions are mainly caused by faults in the DC distribution system, or by sudden large changes of load. Two or more consecutive dips or interruptions can also occur.
Faults in the DC distribution system can inject transient overvoltages into the distribution network; this particular phenomenon is not covered by this document. Voltage interruptions are primarily caused by the switching of mechanical relays when changing from one source to another (e.g. from generator set to battery). During a short interruption, the DC supply network can present either a "high impedance" or "low impedance" condition. The first condition can be due to switching from one source to another; the second condition can be due to the clearing of an overload or fault condition on the supply bus. The latter can cause reverse current (negative peak inrush current) from the load.
These phenomena are random in nature and can be characterised in terms of their duration and the deviation from the nominal voltage. Voltage dips and short interruptions are not always abrupt.
The primary cause of voltage variations is the discharging and recharging of battery systems; however, they are also created when there are significant changes to the load condition of the DC network.
SIST EN IEC 61000-4-29:2026
5 Test levels
The rated voltage for the equipment (U ) shall be used as a reference for the specification of T the voltage test level.
If the EUT has a rated voltage range, the rated voltage U to be used as reference voltage shall T be determined as follows:
- if the upper limit of the voltage range does not exceed by more than 20 % the lower limit of the voltage range, a single voltage within the voltage range may be used as rated voltage U ; T
- in all other cases, the test procedure shall be applied for both the lower and upper limits of the rated voltage range.
The preferred voltage test levels (in % of U ) and durations are given in Table 1, Table 2 and T Table 3 as follows:
- Table 1 corresponding to voltage dips; - Table 2 corresponding to short voltage interruptions; - Table 3 corresponding to voltage variations; The change of the voltage for dips and interruptions is abrupt, in the range of microseconds (see the test generator specifications in Clause 6, Figure 1 and Figure 2). The test conditions of high impedance (see 6.2.3) and low impedance (see 6.2.2) reported in Table 2 refer to the output impedance of the test generator as seen by the EUT during the voltage interruption.
Table 1 – Preferred test levels and durations for voltage dips Test Test level Duration % U s T 0,01 0,03 40 and 70 0,1 Voltage dips or 0,3
SIST EN IEC 61000-4-29:2026
Table 2 – Preferred test levels and durations for short voltage interruptions Test Test condition Test level Duration % U s T 0,001 0,003 0,01 High impedance 0,03 Short interruptions or 0 0,1 low impedance, 0,3
NOTE For certain types of equipment it is appropriate to repeat the test in high impedance and low impedance condition.
Table 3 – Preferred test levels and durations for voltage variations Test Test level Duration % U s T 0,1 85 and 120 0,3 or
Voltage variations 80 and 120
or
The decrease and increase time (see Figure 3) shall be specified by the product standard based on the specific application.
Product standards may choose from each table one or more of the test levels and associated durations. In each table, “x” is an open value that may be chosen to test a special application. The EUT can be sensitive to voltage changes of any duration specified in the tables. In particular, the shortest duration should be tested.
If the EUT is immune to short interruptions in low impedance condition of a specific duration, it is unnecessary to test for other test levels of the same duration (e.g. 40 % or 70 % U ). T
SIST EN IEC 61000-4-29:2026
Key t fall time of the voltage change f t rise time of the voltage change r t time at the reduced voltage s NOTE The percentage values refer to the amplitude of the voltage dip. Figure 1 – Example of voltage dip
SIST EN IEC 61000-4-29:2026
Key t fall time of the voltage change f t rise time of the voltage change r t time at 0 % s NOTE The percentage values refer to the amplitude of the voltage interruption. Figure 2 – Example of short voltage interruption
SIST EN IEC 61000-4-29:2026
Key t time for increasing voltage
t time for decreasing voltage d t time at increased voltage
t time at reduced voltage s NOTE The percentage values refer to the rated voltage U .
T Figure 3 – Examples of voltage variations
6 Test generator
6.1 General
The following features are common to the generator for voltage dips, short interruptions and voltage variations, except where otherwise indicated.
Apart from the generation of the intended dips and interruptions, the test generator shall not emit disturbances which can influence the performance of the EUT. Examples of generators are given in Figure A.1 (test generator based on two power sources with switches) and Figure A.2 (test generator based on a single programmable power source).
SIST EN IEC 61000-4-29:2026
6.2 Characteristics and performances of the generator
6.2.1 General
The test generator shall be able to operate in continuous mode with the following main specifications:
- Output voltage range (U ): up to 120 % of the maximum U o T
- Short interruptions, dips, and variations of the as given in Table 1, Table 2 and Table 3 output voltage:
...