SIST EN 55022:2011/AC:2011
(Corrigendum)Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
Superseded by EN 55032:2012
Einrichtungen der Informationstechnik - Funkstöreigenschaften - Grenzwerte und Messverfahren
Appareils de traitement de l'information - Caractéristiques des perturbations radioélectriques - Limites et méthodes de mesure
Oprema za informacijsko tehnologijo - Karakteristike občutljivosti za radijske motnje - Mejne vrednosti in merilne metode - Popravek
Ta mednarodni standard velja za informacijsko tehnologijo (ITE), kot je opredeljeno v točki 3.1. Podani so postopki za merjenje ravni lažnih signalov, ki ji proizvede ITE, in opredeljene so mejne vrednosti za frekvenčni razpon od 9 kHz do 400 GHz za opremo razreda A in B. Kjer mejne vrednosti niso določene, ni potrebno nobeno merjenje. Namen te objave je vzpostaviti enotne zahteve za raven občutljivosti za radijske motnje pri opremi, zajeti na področjih uporabe, določiti mejne vrednosti občutljivosti, opisati metode merjenja ter standardizirati operativne pogoje in razlago rezultatov.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Einrichtungen der Informationstechnik - Funkstöreigenschaften - Grenzwerte und MessverfahrenAppareils de traitement de l'information - Caractéristiques des perturbations radioélectriques - Limites et méthodes de mesureInformation technology equipment - Radio disturbance characteristics - Limits and methods of measurement35.020Informacijska tehnika in tehnologija na splošnoInformation technology (IT) in general33.100.10EmisijaEmissionICS:Ta slovenski standard je istoveten z:EN 55022:2010/AC:2011SIST EN 55022:2011/AC:2011en,fr,de01-december-2011SIST EN 55022:2011/AC:2011SLOVENSKI
STANDARD
SIST EN 55022:2011/AC:2011
Corrigendum to EN 55022:2010 English version ___________ In the common modifications regarding 8.4, replace on page 3 "2nd paragraph" with "3rd paragraph" to read: "Replace the last sentence of original 3rd paragraph by:". Replace the entire Annex ZA with the following: " Annex ZA
(normative)
Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
NOTE
When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies.
Publication Year Title EN/HD Year IEC/TR 60083 2006 Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC - -
IEC 61000-4-6 + A1 + A2 2003 2004 2006 Electromagnetic compatibility (EMC) -
Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields EN 61000-4-6 + cor
...