Petrol filling stations - Part 1: Safety requirements for construction and performance of metering pumps, dispensers and remote pumping units

2009-05-12 EMA: CEN/TC 221 disbanded by resolution BT C88/2008. The work of CEN/TC 221/SC 2 is transfered to CEN/TC 393.
EC - Annex ZA in line with latest requirements

Tankstellen - Teil 1: Sicherheitstechnische Anforderungen an Bau- und Arbeitsweise von Zapfsäulen, druckversorgten Zapfsäulen und Fernpumpen

Stations-service - Partie 1: Exigences relatives a la construction et aux performances de sécurité des distributeurs a pompe immergée, distributeurs de carburants et unités de pompage a distance

Bencinske črpalke – 1. del: Varnostne zahteve za izdelavo in lastnosti avtomatov za točenje bencina, razdeljevalnikov in oddaljenih črpalnih enot

General Information

Status
Withdrawn
Publication Date
30-Apr-2006
Withdrawal Date
09-Oct-2011
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
05-Oct-2011
Due Date
28-Oct-2011
Completion Date
10-Oct-2011

Relations

Buy Standard

Corrigendum
EN 13617-1:2004/AC:2006
English, French and German language
10 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Petrol filling stations - Part 1: Safety requirements for construction and performance of metering pumps, dispensers and remote pumping unitsStations-service - Partie 1: Exigences relatives a la construction et aux performances de sécurité des distributeurs a pompe immergée, distributeurs de carburants et unités de pompage a distanceTankstellen - Teil 1: Sicherheitstechnische Anforderungen an Bau- und Arbeitsweise von Zapfsäulen, druckversorgten Zapfsäulen und Fernpumpen75.200Petroleum products and natural gas handling equipment01.040.75Naftna in sorodna tehnologija (Slovarji)Petroleum and related technologies (Vocabularies)ICS:SIST EN 13617-1:2004/AC:2006en,fr,deTa slovenski standard je istoveten z:EN 13617-1:2004/AC:200601-maj-2006SIST EN 13617-1:2004/AC:2006SLOVENSKI
STANDARD







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13617-1:2004/ACJanuary 2006Janvier 2006Januar 2006ICS 01.040.75; 75.200English versionVersion FrançaiseDeutsche FassungPetrol filling stations - Part 1: Safety requirements for construction andperformance of metering pumps, dispensers and remote pumping unitsStations-service - Partie 1: Exigencesrelatives à la construction et auxperformances de sécurité des distributeursà pompe immergée, distributeurs decarburants et unités de pompage àdistanceTankstellen - Teil 1: SicherheitstechnischeAnforderungen an Bau- und Arbeitsweisevon Zapfsäulen, druckversorgtenZapfsäulen und FernpumpenThis corrigendum becomes effective on 25 January 2006 for incorporation in the three officiallanguage versions of the EN.Ce corrigendum prendra effet le 25 janvier 2006 pour incorporation dans les trois versionslinguistiques officielles de la EN.Die Berichtigung tritt am 25.Januar 2006 zur Einarbeitung in die drei offiziellen Sprachfassungen derEN in Kraft.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2006 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members.Tous droits d'exploitation sous quelque forme et de quelque manière que ce soit réservés dans le monde entier auxmembres nationaux du CEN.Alle Rechte der Verwertung, gleich in welcher Form und in welchem Verfahren, sind weltweit den nationalen Mitgliedernvon CEN vorbehalten.Ref. No.:EN 13617-1:2004/AC:2006 D/E/F



EN 13617-1:2004/AC:2006 (E/F/D)
2 English version
The Annexes ZA and ZB have to be modified as follows:
Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 94/9/EC This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association to provide a means of conforming to Essential Requirements of the New Approach Directive 94/9/EC.
Once this standard is cited in the Official Journal of the European Communities under that Directive and has been implemented as a national standard in at least one Member State, compliance with the normative Clauses of this standard given in Table ZA.1 confers, within the limits of the scope of this standard, a presumption of conformity with the corresponding Essential Requirements of that Directive and associated EFTA regulations.
Table ZA.1 — Essential requirements of Directive 94/9/EC Equipment and protective systems intended for use in potentially explosive atmospheres — Annex II Essential requirement Subject Relevant clause(s) in this standard 1.0 General requirements 5.1,
5.2 1.0.1 Principles of integrated explosion safety 5.1,
5.2 1.0.3 Special checking and maintenance conditions 7.3 1.04 Surrounding area conditions 5.2 1.0.5 Marking 7.4 1.0.6 (a) All equipment must be accompanied by instructions 7.2 1.0.6 (b) The instructions must be drawn up in one of the Community languages 7.2 1.0.6 (c ) The instructions must contain the drawings and diagrams for the putting into service 7.3 1.1.1 Materials must no trigger off an explosion 5.3.2.1,
5.3.3.1 1.1.2 No reactions of materials and explosive atmospheres 5.3.3.2 1.1.3 No reduction in protection due to corrosion, wear, etc. 5.3.3.2 1.2.1 Regard to technological knowledge 5.2 1.2.2 Intended purpose 1 1.2.3 Enclosed structures and prevention of leaks 5.3.4 1.2.5 Additional means of protection 5.3.6 1.2.6 Safe opening 5.3.6.2 1.2.7 Protection against other hazards 5.3.6.3,
5.3.6.4 1.2.7 (a) Physical injury or other harm 5.3.1 1.2.7 (b) Surface temperature or radiation 5.3.2,
5.3.3.1 1.2.7 (c ) Eliminate non-electrical dangers 5.3.3 1.2.7 (d) Overloads 5.3.2,
5.3.2.6 1.2.8 Overloading of equipment 5.3.2



EN 13617-1:2004/AC:2006 (E/F/D)
3
Table ZA.1 (concluded) Essential requirement Subject Relevant clause(s) in this standard 1.2.9 Flameproof enclosure systems 5.3.5 1.3.1 Hazards arising from different ignition sources 5.1 1.3.2 Hazards arising from static electricity 5.3.3.4,
5.3.4.1 1.3.3 Hazards arising from stray electric and leakage currents 5.3.2.5 1.3.4 Hazards arising from overheating 5.1.2 1.4.1 Safety in presence of voltages humidity vibration etc. 5.3.1.6 1.4.2 Mechanical and thermal stress, aggressive substances 5.3.1.5,
5.3.1.6 1.5.1 Detection of failure of safety devices – fail safe 5.3.1.2 1.5.2 System security in the event of safety device failure 5.3.4.2 1.5.3 Emergency stop controls 5.3.1.2 1.5.4 Control and display units 5.3.1.2 1.5.8 Risks arising from software 5.3.1.2 1.6.1 Manual override 5.3.2.1 1.6.2 Actuation of emergency shutdown 5.3.2.1 1.6.3 Hazards arising from power failure 5.3.2.1 1.6.4 Hazards arising from connections 5.3.2.1 1.6.5 Placing of warning devices as part of equipment 5.3 2.1 Requirements applicable to equipment in category 1 of equipment-group II — 2.1.1 Explosive atmospheres caused by gases, vapours or hazes 5.1,
5.2, 2.1.1.1 No sources of ignition even in event of rare incidents 5.3.5 2.1.1.2 Temperature limit on surfaces can never be exceeded 5.3.5 2.1.1.3 Opening of parts having possible sources of ignition 5.3.5 2.2.1 Explosive atmospheres caused by gases, vapours or mists 5.1,
5.2, 2.2.1.1 No sources of ignition in event of operating faults 5.3.5.5,
5.3.3.1,
5.3.2.1 2.2.1.2 Stated surface temperatures are not exceeded 5.3.2.1 2.2.1.3 Opening of parts having possible sources of ignition
5.3.6
2.3 Requirements applicable to equipment in category 2 of equipment-group II — 2.3.1 Explosive atmospheres caused by gases, vapours or mists 5.1,
5,2 2.3.1.1 Equipment must be so designed and constructed as to prevent foreseeable ignition sources
5.3.3.1,
5.3.2.1 2.3.1.2 Surface temperatures must not exceed the stated maximum surface temperatures 5.1.2 3.1.1 Characteristics of materials 5.3.3.1 3.1.2 Protective systems designed to resist or contain explosions must be capable of withstanding the shock wave
5.3.3.1 3.1.3 Accessories connected to protective systems must be capable of withstanding the expected maximum explosion pressure
5.3.3.1 3.1.4 The reactions caused by pressure in peripheral equipment and connected pipe-work must be taken into consideration
5.3.5
WARNING: Other requirements and other EU Directives may be applicable to the product(s) falling within the scope of this standard.



EN 13617-1:2004/AC:2006 (E/F/D)
4
ANNEX ZB (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 98/37 EEC
This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association to provide a means of conforming to Essential Requirements of the New Approach Directive 98/37 EEC.
Once this standard is cited in the Official Journal of the European Communities under that Directive and has been implemented as a national standard in at least one Member State, compliance with the normative clauses of this standard confers, within the limits of the scope of this standard, a presumption of conformity with the corresponding Essential Requirements of that Directive and associated EFTA regulations.
WARNING: Other requirements and other EU Directives may be applicable to the product(s) falling within the scope of this standard.



EN 13617-1:2004/AC:2006 (E/F/D)
5
Version française
Les Annexes ZA et ZB doivent être modifiées comme suit:
Annexe ZA (informative)
Relation de la présente Norme européenne et les exigences essentielles de la Directive UE 94/9/CE La présente Norme européenne a été préparée dans le cadre d'un mandat donné au CEN par la Commission Européenne et l'Association Européenne de Libre Échange et vient à l'appui des exigences essentielles de la Directive Nouvelle Approche 94/9/CE.
Après publication de la référence de la présente norme au Journal Officiel des Communautés européennes en vertu de cette Directive et mise en application en tant que norme nationale au sein d’au moins un État membre, la conformité aux articles de la présente norme donnés dans le Tableau ZA.1 confère, dans les limites du domaine d’application de la présente norme, une présomption de conformité aux Exigences Essentielles de cette Directive et aux règlements correspondants de l'Association Européenne de Libre Échange.
Tableau ZA.1 — Exigences essentielles de la Directive 1994/9/CE Équipement et systèmes de protection destinés à être utilisés en atmosphères explosibles – Annexe II Exigence essentielle Sujet Paragraphe(s) correspondant(s) de la norme 1.0 Exigences générales 5.1, 5.2 1.0.1 Principes de la sécurité intégrée contre les explosions 5.1, 5.2 1.0.3 Conditions particulières de contrôle et de maintenance 7.3 1.0.4 Conditions de l’espace environnant 5.2 1.0.5 Marquage 7.4 1.0.6 (a) Chaque appareil doit être accompagné d’une notice d’instructions 7.2 1.0.6 (b) La notice d’instructions doit être établie dans une des languescommunautaires 7.2 1.0.6 (c) La notice d’instructions doit comprendre les plans et schémas nécessaires à la mise en service 7.3 1.1.1 Les matériaux ne doivent pas provoquer le déclenchement d’uneexplosion 5.3.2.1, 5.3.3.1 1.1.2 Absence de réactions des matériaux et de l’atmosphère explosible 5.3.3.2 1.1.3 Prise en compte de la résistance à la corrosion, l’usure, etc. 5.3.3.2 1.2.1 Connaissance technologique 5.2 1.2.2 Utilisation prévue 1 1.2.3 Mode de construction fermée et prévention des défauts d’étanchéité 5.3.4 1.2.5 Moyens de protection supplémentaires 5.3.6
«à suivre»



EN 13617-1:2004/AC:2006 (E/F/D)
6 Tableau ZA.1 (suite) Exigence essentielle Sujet Paragraphe(s) correspondant(s) de la norme 1.2.6 Ouverture sans danger 5.3.6.2 1.2.7 Protection contre d’autres risques 5.3.6.3, 5.3.6.4 1.2.7 (a) Dangers de bl
...

Questions, Comments and Discussion