Hydraulic fluid power -- Test code for determination of airborne noise levels -- Part 1: Pumps

Establishes a test code describing procedures based on ISO 2204. Applies to all types of fluid power pumps. Guidelines for application are given in annex C. This second edition cancels and replaces the first edition (1979). Annexes C and D are for information only.

Transmissions hydrauliques -- Code d'essai pour la détermination du niveau de bruit aérien -- Partie 1: Pompes

La présente partie de l'ISO 4412 établit un code d'essai décrivant des méthodes basées sur l'ISO 2204, permettant de déterminer les niveaux de puissance acoustique des pompes pour transmissions hydrauliques dans des conditions définies d'installation et de fonctionnement. Ces méthodes doivent fournir une base de comparaison valable des niveaux de bruit émis par les pompes. traduits en termes de -- niveau de puissance acoustique, pondéré A; -- niveaux de puissance acoustique par bande d'octave. Ces niveaux de puissance acoustique permettent de calculer si nécessaire les niveaux de pression acoustique de référence devant figurer dans les rapports d'essai conformément à l'annexe A. En général, la gamme des fréquences utiles comprend les bandes d'octave dont les fréquences médianes s'échelonnent de 125 Hz à 8 000 Hz1). Des lignes directrices pour l'application de la présente partie de l'ISO 4412 sont données dans l'annexe C. La présente partie de l'ISO 4412 est applicable à tous les types de pompes hydrauliques, quelle que soit leur taille, fonctionnant dans des conditions stables spécifiées, sauf si une limite est imposée par les dimensions de la salle d'essais (voir article 5). 1) 1 Hz = 1 s-1

Fluidna tehnika - Hidravlika - Postopek ugotavljanja ravni zračnega hrupa - 2. del: Motorji

General Information

Status
Published
Publication Date
30-Nov-1998
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-1998
Due Date
01-Dec-1998
Completion Date
01-Dec-1998

Relations

Buy Standard

Standard
ISO 4412-1:1991 - Hydraulic fluid power -- Test code for determination of airborne noise levels
English language
20 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 4412-1:1998 - manjkajo strani 18, 19 in 20
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ISO 4412-1:1991 - Transmissions hydrauliques -- Code d'essai pour la détermination du niveau de bruit aérien
French language
20 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 4412-1:1991 - Transmissions hydrauliques -- Code d'essai pour la détermination du niveau de bruit aérien
French language
20 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

IS0
INTERNATIONAL
4412-l
STANDARD
Second edition
1991-08-15
Hydraulic fluid power - Test code for
determination of airborne noise levels -
Part 1:
Pulnps
Transmissions hydrauliques Code d ’essai pour la d&termination du
niveau de bruit a&Hen -
Partie 1: Pompes
Reference number
IS0 4412-1:1991(E)

---------------------- Page: 1 ----------------------
IS0 4412-1:1991(E)
Contents
Page
1
1 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Normative references
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-. 1
3 Definitions
4 Measurement uncertainty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2
5 Test environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Instrumentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .~. 2
7 installation conditions . 2
3
8 Operating conditions .
............. 4
9 Location and number of sound measurement points
4
IO Test procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4’
11 Information to be recorded
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 Test report
6
13 Identification statement (Reference to this part of IS0 4412)
Annexes
A Calculation of sound levels . 7
8
B Errors and classes of measurement .
........... 9
C Guidelines for the application of this part of IS0 4412
20
D Bibliography .
8 is0 1991
Ail rights reserved. No part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without
permission in writing from the publisher.
international Organization for Standardization
Case Postaie 56 l CH-1211 Geneve 20 l Switzerland
Printed in Switzerland
ii

---------------------- Page: 2 ----------------------
IS0 4412-1:1991(E)
Foreword
IS0 (the International Organization for Standardization) is a worldwide
federation of national standards bodies (IS0 member bodies). The work
of preparing International Standards is normally carried out through IS0
technical committees. Each member body interested in a subject for
which a technical committee has been established has the right to be
represented on that committee. International organizations, govern-
mental and non-governmental, in liaison with ISO, also take part in the
work. IS0 collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an Inter-
national Standard requires approval by at least 75 % of the member
bodies casting a vote.
International Standard IS0 4412-1 was prepared jointly by Technical
Committees lSO/TC 131, Fluid power systems, Sub-Committee SC 8,
Product testing and contamination control and ISO/TC 43, Acoustics.
This second edition cancels and replaces the first edition (IS0
4412-1:1979), of which clauses 12 and 13 have been transferred to form
a new annex A. The former annex A has become annex B, and annexes
C and D have been added.
IS0 4412 consists of the following parts, under the general title Hydraulic
fluid power - Test code for determination of airborne noise levels:
- Part 1: Pumps
- Part 2: Motors
- Part 3: Pumps - Method using a parallelepiped microphone array
Annexes A and B form an integral part of this part of IS0 4412. Annexes
C and D are for information only.
. . .
Ill

---------------------- Page: 3 ----------------------
IS0 4412=1:1991(E)
Introduction
In hydraulic fluid power systems, power is transmitted and controlled
through a liquid under pressure in a closed circuit. Pumps are compo-
nents which convert rotary mechanical power into fluid power. During
the process of converting mechanical power into hydraulic fluid power,
airborne noise, fluid-borne vibrations and structure-borne vibrations are
radiated from the pump.
The airborne noise level of a hydraulic fluid power pump is an important
consideration in component selection. The noise measurement tech-
nique must, therefore, be such as to yield accurate appraisals of these
airborne noise levels. The determination of noise levels is complicated
by the interactions which occur during noise measurements. The fluid-
borne and structure-borne vibrations from the pump can be transmitted
to the circuit and ultimately give rise to background airborne noise lev-
els which could affect the determination of the pump airborne noise
levels.
The procedures described in this part of IS0 4412 are intended to
measure only the airborne noise radiated directly from the pump under
test.

---------------------- Page: 4 ----------------------
IS0 4412-1:1991(E)
INTERNATIONAL STANDARD
Hydraulic fluid power - Test code for determination of
airborne noise levels -
Part 1:
Pumps
on this part of IS0 4412 are encouraged to investi-
1 Scope
gate the possibility of applying the most recent edi-
tions of the standards indicated below. Members of
This part of IS0 4412 establishes a test code de-
IEC and IS0 maintain registers of currently valid In-
scribing procedures, based on IS0 2204, for the de-
ternational Standards.
termination of the sound power levels of a hydraulic
fluid power pump, under controlled conditions of in-
IS0 3448:1975, lndustrial liquid lubricants - IS0 vis-
stallation and operation, suitable for providing a ba-
cosify classification.
sis for comparing the noise levels of pumps in terms
of:
IS0 3744:1981, Acoustics - Determination of sound
power levels of noise sources - Engineering meth-
-
A-weighted sound power level;
ods for fi-ee-field conditions over a reflecting plane.
-
octave band sound power levels.
IS0 3745:1977, Acoustics - Determination of sound
From these sound power levels, if required, refer- power levels of noise sources - Precision methods
ence sound pressure levels may be calculated for for anechoic and semi-anechoic rooms.
reporting purposes in accordance with annex A.
IS0 55983985, Fluid power systems and components
For general purposes, the frequency range of inter-
- Vocabulary.
est includes the octave bands with centre fre-
quencies between 125 Hz and 8000 Hz.?
IS0 6743-4:1982, Lubricants, industrial oils and re-
lated products (class L) - Classification, - Part 4:
Guidelines for the application of this part of IS0 4412
Family N (Hydraulic systems).
are given in annex C.
IEC 50(801): 1984, lnternational Electrotechnical Vo-
This part of IS0 4412 is applicable to all types of
cabulary - Chapter 80 1: Acoustics and elec tro-
hydraulic fluid power pumps operating under
acoustics.
steady-state conditions, irrespective of size, except
for any limitations imposed by the size of the test
IEC 65111979, Sound level meters.
environment (see clause 5).
2 Normative references 3 Definitions
The following standards contain provisions which, For the purposes of this part of IS0 4412, the defi-
through reference in this text, constitute provisions nitions given in IS0 5598, IEC 50 and the following
of this part of IS0 4412. At the time of publication, definitions apply. It is accepted that the latter defi-
the editions indicated were valid. All standards are nitions may differ from those in other specific Inter-
subject to revision, and parties to agreements based national Standards.
1) 1 Hz = 1 s-1

---------------------- Page: 5 ----------------------
IS0 4412-1:1991(E)
3.1 free sound field: Sound field in a homogeneous,
isotropic medium free of boundaries. Table 1 - Standard deviation of sound power level
NOTE 1 In practice, it is a field in which the effects of
Standard deviation, dB,
the boundaries are negligible over the frequency range
of interest.
for octave bands centred on:
125 Hz 250 Hz
500 Hz 1000 Hz to 8000 Hz
3.2 free field over a reflecting plane: Field produced
4000 Hz
by a source in the presence of one reflecting plane
on which the source is located.
590 33 290 zo
310
3.3 reverberant sound field: That portion of the
The standard deviations given in table 1 include the
sound field in a test room over which the influence
of sound received directly from the source is negli- effects of allowable variations in the positioning of
the measurement points and in the selection of any
gible.
prescribed measurement surface, but exclude vari-
ations in the sound power output of the source from
3.4 anechoic room: Test room having boundaries
test to test.
which absorb essentially all of the incident sound
energy over the frequency range of interest, thereby
NOTE 5 The A-weighted sound power level will in most
affording free-field conditions over the measurement
practical cases be determined with a standard deviation
surface.
of approximately 2 dB.
3.5 mean-square sound pressure: The sound
5 Test environment
pressure averaged in space and time on a mean-
square basis.
Tests shall be conducted in an environment which
In practice, this is estimated by space and time provides “free-field over a reflecting plane” con-
NOTE 2
averaging over a finite path length or over a number of
ditions which meet the environmental qualification
fixed microphone positions.
requirements described in IS0 3744:1981, clause 4
and annex A.
3.6 mean sound pressure level: Ten times the log-
For more precise measurements, conduct tests in
arithm to the base 10 of the ratio of the mean-square
accordance with IS0 3745.
sound pressure to the square of the reference sound
pressure, in decibels (dB).
6 Instrumentation
NOTE 3 The weighting network or the width of the frer
quency band used should always be indicated; for exam-
6.1 The instrumentation used to measure fluid
ple, A-weighted sound pressure level, octave band sound
pressure level. The reference sound pressure is 20 [+ ‘a*). flow, fluid pressure, pump speed and fluid tempera-
ture shall be in accordance with the recommen-
dations for “industrial class” accuracy of testing; i.e.
3.7 sound power level: Ten times the logarithm to
class C given in annex B.
the base 10 of the ratio of a given sound power to
the refere nce soun d power , in decibels.
6.2 The instrumentation used for acoustical
N ’OTE 4 The weighting network or the width of the fre-
measurements shall be in accordance with IEC 651.
quency band used should always be indicated. The refer-
This instrumentation shall be in accordance with
ence sound power is 1 pW3).
IS0 3744 for both performance and calibration; i.e.
type 2 instruments for engineering (grade 2)
38 . volume of source under test: Volume of the en-
measurements.
velope of the whole pump under test.
7 Installation conditi ’ons
4 Measurement uncertainty
7.1 Pump location
,
Methods of measurement should be used which
The pump may be located in any position consistent
tend to result in standard deviations which are equal
with the source installation and measurement sur-
to or less than those specified in table 1. Methods
face (or microphone traverse) requirements speci-
given in IS0 3744 meet this requirement.
fied in IS0 3744 for the test environment being used.
= 10--S N/m*
2) 1 PPa
3) 1 pw = 10-Q w
2

---------------------- Page: 6 ----------------------
IS0 4412-1:1991(E)
least 15 m of hose shall be used to meet this re-
7.2 Pump mounting
quirement.
7.2.1 The pump mounting shall be constructed so
that it will minimize the noise radiated by the
7.4.6 A stable load valve shall be used.
mounting as a result of pump vibrations.
Unstable load valves in the discharge line can
NOTE 6
7.2.2 The mounting bracket shall be constructed of generate and transmit noise through the fluid and piping
which can emerge as airborne sound at the pump.
high-damping material or with sound-damping and
sound-insulating material applied to the bracket as
required.
7.4.7 The load valve shall be positioned far from
the pump, preferably outside the test room, to mini-
7.2.3 Vibration isolation techniques, if needed,
mize the interaction. The load valve shall be located
shall be used even if the pump is usually securely
close to the pump only when adequate control of its
mounted.
acoustic performance can be provided.
7.2.4 Flange mountings that are as small as prac-
7.4.8 All fluid lines and load valves in the test
tical shall be used so as to minimize interference
space shall be wrapped with sound-isolating ma-
with radiation of sound towards the shaft end of the
terials, if required (see 10.1). Material having a
pump.
sound-transmission loss of at least 10 dB at 125 Hz,
and a greater loss at higher frequencies, shall be
7.3 Pump drive
used.
The drive motor shall be located outside the test
space and the pump shall be driven through flexible
couplings and an intermediate shaft, or the motor
8 Operating conditions
shall be isolated in an acoustic enclosure.
8.1 Determine the sound power levels of the pump
7.4 Hydraulic circuit
(see annex A) for any desired set of operating con-
ditions (see 11.3.7).
7.4.1 The circuit shall include all oil filters, oil
coolers, reservoirs and restrictor valves as required
to meet the pump hydraulic operating conditions
8.2 These test conditions shall be maintained
(see clause 8).
throughout the test within the limits given in table 2.
7.4.2 The test fluid and degree of filtration shall be
Table 2 - Allowable variations of mean indicated
in accordance with the pump manufacturer ’s rec-
values of controlled parameters
ommendations.
Test parameter Allowable variation
7.4.3 Inlet and discharge lines shall be installed
with diameters in accordance with the manufac-
Flow +2 %
-
turers’ recommended practice. Extra care shall be
Pressure +2 O/o
-
exercised when assembling inlet lines to prevent air
leaking into the circuit. 3-2 %
Speed
-
Temperature +2 “C
-
7.4.4 The inlet pressure gauge shall be mounted
at the same height as the inlet fittings or it shall be
calibrated for any height difference.
tested in the
8.3 The shall be
pump
7.4.5 The length of line between the pump and the “as-delivered” condition with any ancillary pumps
load valve shall be selected in order to minimize the and valves operating normally during the test, so as
effect of standing waves in the discharge line which to include their noise contributions to the airborne
can increase the sound radiated from the pump. At noise level of the pump.

---------------------- Page: 7 ----------------------
IS0 4412-1:1991(E)
Measure the following for each test:
9 Location and number of sound
measurement points
a) pump speed and flow rate;
The location and number of measurement points
b) fluid temperature and pressure at pump inlet and
shall be as required by IS0 3744 for the method of
fluid pressure at discharge fittings or at the test
measurement selected for the pump noise test.
point provided by the pump manufacturer;
10 Test procedure c) band sound pressure levels at each measure-
ment point over the frequency range of interest;
10.1 Background noise measurements
d) A-weighted sound pressure level at each
measurement point.
10.1.1 Measure the background noise of interest
that is present during the pump noise test which
10.2.2 New or rebuilt pumps
does not emanate from the pump itself.
Over the frequency range of interest, the band
10.2.2.1 Repeat the initial pump measurement test
sound pressure levels of this background noise shall
of the series at the end of a test series or after 1 h
be at least 6 dB below the pump band sound press-
of testing.
ure levels at each measurement point.
10.2.2.2 If the A-weighted sound level at any selec-
10.1.2 Correct for this background noise, if evi-
ted measurement point does not duplicate that of
denced by these measurements, by applying the
the first test within 2 dB (A), the whole test series
corrections for this purpose given in IS0 3744.
shall be invalidated.
10.1.3 When measurement of band levels of back-
ground noise is not practical, the A-weighted back- II Information to be recorded
ground sound level of each measurement point shall
be at least 6 dB below the pump A-weighted sound
11 .l Specifications
level.
The information given in 11.2 and 11.3 shall be
Correct these A-weighted measurements for back-
compiled and recorded for all measurements made
ground noise.
according to the requirements of this part of
NOTES
IS0 4412.
7 Easing the requirements for background noise levels
can lead to an overestimate of the pump band sound 11.2 General information
pressure levels.
name and address of the pump manufacturer
a)
8 The A-weighted background sound level at each
and, if applicable, the user;
measurement point may be checked by covering the
pump with sound-insulating materials capable of a trans-
reference number(s) for identification of the
b)
mission loss of at least 10 dB over the frequency range
pump;
which is “determining” the A-weighted sound level of the
pump*
name and address of persons or organization
Cl
responsible for the acoustic tests on the pump;
10.1.4 If the background level is found to be too
high, check for further noise control of the pump
date and place of acoustic tests;
d)
mounting, drive or hydraulic circuit, as indicated.
statement that the sound power levels of the
e)
10.1.5 Ensure that the orientation of the micro-
pump have been obtained in full conformance
phone and the period of observation are as specified
with this part of IS0 4412 and IS0 3744 for the
in IS0 3744.
determination of sound power levels of noise
sources (see also clause 13).
10.2 Pump measurements
11.3 Pump under test
10.2.1 Measurement sequence
Prior to commencement of a series of tests, operate 11.3.1 Description of pump
the pump for a sufficient time to purge air from the
system and to stabilize all variables, including fluid a) type of pump (e.g. gear or piston), including an-
condition, to within the limits specified in table 2. cillary equipment;
4

---------------------- Page: 8 ----------------------
IS0 4412-1:1991(E)
b) type of displacement (e.g. fixed or variable); 11.3.5.2 Show on this sketch the location of other
reflecting or absorbing screens and noise sources
overa II linear dimensions (with sketch if which can influence measurements.
Cl pump
neces
sat-y);
1 I .3.6 Instrumentation
d) pump maximum displacement;
a) details of equipment used to monitor pump op-
e) type of displacement controller and setting.
erating conditions (see 11.3.7), including type,
serial number and manufacturer;
11.3.2 Acoustic environment for tests
b) details of equipment used for acoustic measure-
a) internal dimensions of the test room and the type
ments including name, type, serial number and
of acoustic field for the measurements (e.g. free
manufacturer;
field over a reflecting plane);
c) bandwidth of frequency analyser;
b) the acoustical treatment of the test room;
d) overall frequency response of instrumentation
c) the date of measurement;
system and date and method of calibration;
d) ambient air temperature (in degrees Celsius),
e) method of calibration of microphones and date
relative humidity (in percentage) and barometric
and place of calibration.
pressure (in pascats ”));
results of acoustic al qualifica tion of test environ-
e)
11.3.7 Pump operating conditions
required b y clause 5.
ments as
Include the following details for each test:
11.3.3 Reference sound source (when applicable)
a) full description of fluid, including classification in
a) manufacturer, type and serial number;
accordance with IS0 6743-4;
b) sound power level calibration data, including
b) fluid viscosity classification in accordance with
name of calibrating laboratory and date of cali-
IS0 3448, in centistokes or in square millimetres
bration.
per second5);
11.3.4 Mounting and installation conditions of pump
c) shaft speed, in revolutions per minute;
a) description of pump mounting conditions;
d) inlet pressure, in megapascals (bar9));
nature and ch aracterist its of the hydraulic circu it
b)
e) outlet pressure, in megapascals (bars);
and details of any acou stic insul ation treatment
(flow) eithe r measured or calcu-
delivery
9 pump
c) nature and description of other machines being
lated, in litres per mi nute;
used which could have an influence on the
measured sound pressure levels of the pump.
g) temperature of fluid at pump inlet, in degrees
Celsius.
Location of pump in test environment
11.3.5
11.3.8 Acoustical data
11.3.5.1 Include a sketch showing the location of
the pump in relation to walls, floor and ceiling of the
Include all data as required by IS0 3744.
test room.
= 10-S bar
4) 1 Pa
5) 1 cst =
1 mm ’ls
= 105 N/m2 = 105 Pa = 0,l MPa
6) 1 bar
5

---------------------- Page: 9 ----------------------
IS0 4412-1:1991(E)
paragraphs of IS0 3744 for the determination of
12 Test report
sound power levels of noise sources.
The test report shall contain the following infor-
mation:
13 Identification statement (Reference to
this part of IS0 4412)
a) the A-weighted sound power level and octave
band sound power levels for each frequency
Use the following statement in test reports, cata-
band of interest for each set of operating con-
logues and sales literature when electing to comply
ditions;
with this part of IS0 4412:
b) a statement that the sound power levels have
“Airborne noise levels determined in accordance
been obtained in full conformance with the pro-
with IS0 4412-1, Hydraulic #7uid power- - Test code
cedures of this part of IS0 4412 and specific
for determination of airborne noise levels - Part I:
Pumps ”.

---------------------- Page: 10 ----------------------
IS0 4412=1:1991(E)
Annex A
(normative)
Calculation of sound levels
A.1 Calculation of pump mean sound A.2 Calculation of mean sound pressure
pressure levels and sound power levels
level at a reference distance
The mean sound pressure level at a distance Y, in
A.l.1 Refer to IS0 3744 for information regarding
metres, from the equivalent point source radiating
corrections to be applied and the method of calcu-
into a free field over a reflecting plane (hemi-
lating the mean levels and the pump sound power
spherical radiation) from the calculated pump sound
levels.
power level is evaluated as follows:
A.l.2 Correct the measured band sound pressure
levels (and A-weighted sound levels, where appro-
priate) at each measurement position for the meas-
where
background
ured noise (background noise
corrections).
/ is the mean sound pressure level, A-
“P
weighted or in bands, in decibels (refer-
ence: 20 pPa);
A.l.3 Use these corrected levels to calculate the
pump mean band sound levels and mean A-
I is the A-weighted or band power level of
‘W
weighted sound level.
the pump under test, in decibels (refer-
ence: 1 pW);
A.l.4 Calculate the pump sound power level from
these mean sound pressure levels, taking into ac-
2nP2 is the area of the hemisphere, in square
count any correction for unwanted environmental
metres, of radius r;
reflections (environmental correction factor).
c = 1 m*.
co
For calculation purposes, choose a reference dis-
= 1 m, in which case the numerical value
tance of Y
of r., is obtained by subtracting 8 dB from the nu-
merrcal value of the calculated sound power level,

---------------------- Page: 11 ----------------------
IS0 4412=1:1991(E)
Annex B
(normative)
Errors and classes of measurement
6.1 Classes of measurement
Table B.l - Permissible systematic errors of
measuring instruments as determined during
Depending on the accuracy required, the tests may
calibration
be carried out to one of three classes of measure-
I I I I
ment, A, B or C. The classes of measurement shall
Class of
1 Units 1 A 1 B 1 C
be agreed between the parties concerned. The use
measurement
of class A and B is restricted to special cases when
there is a need to have the performance more pre-
+ 1,5 + 2,5
Input signal O/o + 0,5 -
- -
cisely defined. Class A and B tests require more
Flow % +0,5 + 1,5
- Z!SV
-
accurate apparatus and methods, which may in-
Pressure % +0,5 + 1,5 + 2,5
- - -
crease the costs of such tests.
Temperature OC +0,5 + l,o + 2,0
- - -
Speed O/a + 0,5 + 1,o + 2,0
B .2 Errors - - -
Any device or method which by calibration or com-
parison with International Standards has been dem-
NOTE - The percentage limits given are of the value
of the quantity being measured and not of the maxi-
onstrated to be capable of measuring with
mum values of the test or the maximum reading of the
systematic errors not exceeding the limits given in
instrument.
tableB.1 may be used.

---------------------- Page: 12 ----------------------
IS0 4412-1:1991(E)
Annex C
(informative)
Guidelines for the application of this part of IS0 4412
but not an exact measure, of its overall acoustic
C.l Introduction
performance.
This annex describes a series of recommended
techniques that are designed to enable reliable
Pressure llne
measurements of hydraulic pump airborne noise to
be taken, using an anechoic chamber, in accordance
- Bell houslng
with this part of IS0 4412. /
Drive motor
-L I
a-- 7
C.2 General
--W
e-- 4
H/I
4 A 1 I A 4 1
411
This annex should be read in conjunction with
I : 1 f-I1 I I ;
I
d
IS0 2204 and IS0 3744.
The principle of this part of IS0 4412 is based on
measurements taken over a hemispherical surface
centred over the pump unit under test. It does,
however, present certain operational difficulties. The
methods outlined in this annex represent a practical
solution to these problems and allow compliance
with the requirements of this part of IS0 4412.
In a hydraulic installation, the vibrational energy of
the pump becomes distributed among other compo-
nents in the system, such as the connecting pipe-
work, the pump mounting, the drive shaft and the
prime mover. This distribution of energy is a
L- Return llne
characteristic of the particular installation and is not
inherently a measure of pump noise. The pump,
Key
however, produces sound energy which can cause
--- Alrborne noke
the installation as a whole to emit noise. FigureC.1
_ Fluid-borne noise
illustrates the mechanism. It is the objective of this
- Structure-borne noise
annex to ensure that the measured noise is that
radiated by the external casing of the pump and
Figure C.l - Transmission paths of sound energy
nothing else. This component of noise will then be
from pumps
genuinely a characteristic of the pump and as little
affected as possible by the particular installation.
The total airborne noise of a practical installation
includes radiation from all the components of the
C.3 Choice of measurement environment
hydraulic system. These are excited, in the main, by
pump-generated fluid-borne noise (pressure ripple)
This part of IS0 4412 permits measurement in a
present in the circuit and by structural transmission
reverberant or an anechoic room. The anechoic
of vibration from the pump to attached components.
room may take the form of a fully free-field environ-
ment or a free field over a single reflecting plane,
These mechanisms may well predominate in the
termed a (‘semi-anechoic chamber ”.
generation of total system noise. It is found, how-
ever, that low airborne noise radiation from the
An anechoic or semi-anechoic room is normally
pump casing tends to be associated with low fluid-
preferable for pump testing work because there are
borne and structural noise generation. The values
fewer measurement uncertainties associated with
obtained for airborne noise radiation from the cas-
the strongly periodic noise typically radiated by
ing of a pump may thus be taken as an indication,
pumps. Anechoic or semi-anechoic environments

---------------------- Page: 13 ----------------------
IS0 4412-1:1991 (E)
also allow directivity information to be obtained
C.4.2 Number and position of microphones
which, though not required by this part of IS0 4412,
can provide valuable assistance when setting up a
In order to obtain a valid estimate of the mean
system or diagnosing pump acoustic output.
sound pressure, the sound field has to be sampled
at several points over the measurement surface. A
Although a reverberant room is the least affected by
basic array of IO points is called for, but this number
accidental oil spillage, the acoustic advantages of
may be reduced if experience shows that the sound
an anechoic or semi-anechoic room are frequently
field is sufficiently
...

SLOVENSKI STANDARD
SIST ISO 4412-1:1998
01-december-1998
)OXLGQDWHKQLND+LGUDYOLND3RVWRSHNXJRWDYOMDQMDUDYQL]UDþQHJDKUXSDGHO
0RWRUML
Hydraulic fluid power -- Test code for determination of airborne noise levels -- Part 1:
Pumps
Transmissions hydrauliques -- Code d'essai pour la détermination du niveau de bruit
aérien -- Partie 1: Pompes
Ta slovenski standard je istoveten z: ISO 4412-1:1991
ICS:
17.140.20 Emisija hrupa naprav in Noise emitted by machines
opreme and equipment
23.100.10 +LGUDYOLþQHþUSDONHLQPRWRUML Pumps and motors
SIST ISO 4412-1:1998 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST ISO 4412-1:1998

---------------------- Page: 2 ----------------------

SIST ISO 4412-1:1998
IS0
INTERNATIONAL
4412-l
STANDARD
Second edition
1991-08-15
Hydraulic fluid power - Test code for
determination of airborne noise levels -
Part 1:
Pulnps
Transmissions hydrauliques Code d ’essai pour la d&termination du
niveau de bruit a&Hen -
Partie 1: Pompes
Reference number
IS0 4412-1:1991(E)

---------------------- Page: 3 ----------------------

SIST ISO 4412-1:1998
IS0 4412-1:1991(E)
Contents
Page
1
1 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Normative references
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-. 1
3 Definitions
4 Measurement uncertainty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2
5 Test environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Instrumentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .~. 2
7 installation conditions . 2
3
8 Operating conditions .
............. 4
9 Location and number of sound measurement points
4
IO Test procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4’
11 Information to be recorded
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 Test report
6
13 Identification statement (Reference to this part of IS0 4412)
Annexes
A Calculation of sound levels . 7
8
B Errors and classes of measurement .
........... 9
C Guidelines for the application of this part of IS0 4412
20
D Bibliography .
8 is0 1991
Ail rights reserved. No part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without
permission in writing from the publisher.
international Organization for Standardization
Case Postaie 56 l CH-1211 Geneve 20 l Switzerland
Printed in Switzerland
ii

---------------------- Page: 4 ----------------------

SIST ISO 4412-1:1998
IS0 4412-1:1991(E)
Foreword
IS0 (the International Organization for Standardization) is a worldwide
federation of national standards bodies (IS0 member bodies). The work
of preparing International Standards is normally carried out through IS0
technical committees. Each member body interested in a subject for
which a technical committee has been established has the right to be
represented on that committee. International organizations, govern-
mental and non-governmental, in liaison with ISO, also take part in the
work. IS0 collaborates closely with the International Electrotechnical
Commission (IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an Inter-
national Standard requires approval by at least 75 % of the member
bodies casting a vote.
International Standard IS0 4412-1 was prepared jointly by Technical
Committees lSO/TC 131, Fluid power systems, Sub-Committee SC 8,
Product testing and contamination control and ISO/TC 43, Acoustics.
This second edition cancels and replaces the first edition (IS0
4412-1:1979), of which clauses 12 and 13 have been transferred to form
a new annex A. The former annex A has become annex B, and annexes
C and D have been added.
IS0 4412 consists of the following parts, under the general title Hydraulic
fluid power - Test code for determination of airborne noise levels:
- Part 1: Pumps
- Part 2: Motors
- Part 3: Pumps - Method using a parallelepiped microphone array
Annexes A and B form an integral part of this part of IS0 4412. Annexes
C and D are for information only.
. . .
Ill

---------------------- Page: 5 ----------------------

SIST ISO 4412-1:1998
IS0 4412=1:1991(E)
Introduction
In hydraulic fluid power systems, power is transmitted and controlled
through a liquid under pressure in a closed circuit. Pumps are compo-
nents which convert rotary mechanical power into fluid power. During
the process of converting mechanical power into hydraulic fluid power,
airborne noise, fluid-borne vibrations and structure-borne vibrations are
radiated from the pump.
The airborne noise level of a hydraulic fluid power pump is an important
consideration in component selection. The noise measurement tech-
nique must, therefore, be such as to yield accurate appraisals of these
airborne noise levels. The determination of noise levels is complicated
by the interactions which occur during noise measurements. The fluid-
borne and structure-borne vibrations from the pump can be transmitted
to the circuit and ultimately give rise to background airborne noise lev-
els which could affect the determination of the pump airborne noise
levels.
The procedures described in this part of IS0 4412 are intended to
measure only the airborne noise radiated directly from the pump under
test.

---------------------- Page: 6 ----------------------

SIST ISO 4412-1:1998
IS0 4412-1:1991(E)
INTERNATIONAL STANDARD
Hydraulic fluid power - Test code for determination of
airborne noise levels -
Part 1:
Pumps
on this part of IS0 4412 are encouraged to investi-
1 Scope
gate the possibility of applying the most recent edi-
tions of the standards indicated below. Members of
This part of IS0 4412 establishes a test code de-
IEC and IS0 maintain registers of currently valid In-
scribing procedures, based on IS0 2204, for the de-
ternational Standards.
termination of the sound power levels of a hydraulic
fluid power pump, under controlled conditions of in-
IS0 3448:1975, lndustrial liquid lubricants - IS0 vis-
stallation and operation, suitable for providing a ba-
cosify classification.
sis for comparing the noise levels of pumps in terms
of:
IS0 3744:1981, Acoustics - Determination of sound
power levels of noise sources - Engineering meth-
-
A-weighted sound power level;
ods for fi-ee-field conditions over a reflecting plane.
-
octave band sound power levels.
IS0 3745:1977, Acoustics - Determination of sound
From these sound power levels, if required, refer- power levels of noise sources - Precision methods
ence sound pressure levels may be calculated for for anechoic and semi-anechoic rooms.
reporting purposes in accordance with annex A.
IS0 55983985, Fluid power systems and components
For general purposes, the frequency range of inter-
- Vocabulary.
est includes the octave bands with centre fre-
quencies between 125 Hz and 8000 Hz.?
IS0 6743-4:1982, Lubricants, industrial oils and re-
lated products (class L) - Classification, - Part 4:
Guidelines for the application of this part of IS0 4412
Family N (Hydraulic systems).
are given in annex C.
IEC 50(801): 1984, lnternational Electrotechnical Vo-
This part of IS0 4412 is applicable to all types of
cabulary - Chapter 80 1: Acoustics and elec tro-
hydraulic fluid power pumps operating under
acoustics.
steady-state conditions, irrespective of size, except
for any limitations imposed by the size of the test
IEC 65111979, Sound level meters.
environment (see clause 5).
2 Normative references 3 Definitions
The following standards contain provisions which, For the purposes of this part of IS0 4412, the defi-
through reference in this text, constitute provisions nitions given in IS0 5598, IEC 50 and the following
of this part of IS0 4412. At the time of publication, definitions apply. It is accepted that the latter defi-
the editions indicated were valid. All standards are nitions may differ from those in other specific Inter-
subject to revision, and parties to agreements based national Standards.
1) 1 Hz = 1 s-1

---------------------- Page: 7 ----------------------

SIST ISO 4412-1:1998
IS0 4412-1:1991(E)
3.1 free sound field: Sound field in a homogeneous,
isotropic medium free of boundaries. Table 1 - Standard deviation of sound power level
NOTE 1 In practice, it is a field in which the effects of
Standard deviation, dB,
the boundaries are negligible over the frequency range
of interest.
for octave bands centred on:
125 Hz 250 Hz
500 Hz 1000 Hz to 8000 Hz
3.2 free field over a reflecting plane: Field produced
4000 Hz
by a source in the presence of one reflecting plane
on which the source is located.
590 33 290 zo
310
3.3 reverberant sound field: That portion of the
The standard deviations given in table 1 include the
sound field in a test room over which the influence
of sound received directly from the source is negli- effects of allowable variations in the positioning of
the measurement points and in the selection of any
gible.
prescribed measurement surface, but exclude vari-
ations in the sound power output of the source from
3.4 anechoic room: Test room having boundaries
test to test.
which absorb essentially all of the incident sound
energy over the frequency range of interest, thereby
NOTE 5 The A-weighted sound power level will in most
affording free-field conditions over the measurement
practical cases be determined with a standard deviation
surface.
of approximately 2 dB.
3.5 mean-square sound pressure: The sound
5 Test environment
pressure averaged in space and time on a mean-
square basis.
Tests shall be conducted in an environment which
In practice, this is estimated by space and time provides “free-field over a reflecting plane” con-
NOTE 2
averaging over a finite path length or over a number of
ditions which meet the environmental qualification
fixed microphone positions.
requirements described in IS0 3744:1981, clause 4
and annex A.
3.6 mean sound pressure level: Ten times the log-
For more precise measurements, conduct tests in
arithm to the base 10 of the ratio of the mean-square
accordance with IS0 3745.
sound pressure to the square of the reference sound
pressure, in decibels (dB).
6 Instrumentation
NOTE 3 The weighting network or the width of the frer
quency band used should always be indicated; for exam-
6.1 The instrumentation used to measure fluid
ple, A-weighted sound pressure level, octave band sound
pressure level. The reference sound pressure is 20 [+ ‘a*). flow, fluid pressure, pump speed and fluid tempera-
ture shall be in accordance with the recommen-
dations for “industrial class” accuracy of testing; i.e.
3.7 sound power level: Ten times the logarithm to
class C given in annex B.
the base 10 of the ratio of a given sound power to
the refere nce soun d power , in decibels.
6.2 The instrumentation used for acoustical
N ’OTE 4 The weighting network or the width of the fre-
measurements shall be in accordance with IEC 651.
quency band used should always be indicated. The refer-
This instrumentation shall be in accordance with
ence sound power is 1 pW3).
IS0 3744 for both performance and calibration; i.e.
type 2 instruments for engineering (grade 2)
38 . volume of source under test: Volume of the en-
measurements.
velope of the whole pump under test.
7 Installation conditi ’ons
4 Measurement uncertainty
7.1 Pump location
,
Methods of measurement should be used which
The pump may be located in any position consistent
tend to result in standard deviations which are equal
with the source installation and measurement sur-
to or less than those specified in table 1. Methods
face (or microphone traverse) requirements speci-
given in IS0 3744 meet this requirement.
fied in IS0 3744 for the test environment being used.
= 10--S N/m*
2) 1 PPa
3) 1 pw = 10-Q w
2

---------------------- Page: 8 ----------------------

SIST ISO 4412-1:1998
IS0 4412-1:1991(E)
least 15 m of hose shall be used to meet this re-
7.2 Pump mounting
quirement.
7.2.1 The pump mounting shall be constructed so
that it will minimize the noise radiated by the
7.4.6 A stable load valve shall be used.
mounting as a result of pump vibrations.
Unstable load valves in the discharge line can
NOTE 6
7.2.2 The mounting bracket shall be constructed of generate and transmit noise through the fluid and piping
which can emerge as airborne sound at the pump.
high-damping material or with sound-damping and
sound-insulating material applied to the bracket as
required.
7.4.7 The load valve shall be positioned far from
the pump, preferably outside the test room, to mini-
7.2.3 Vibration isolation techniques, if needed,
mize the interaction. The load valve shall be located
shall be used even if the pump is usually securely
close to the pump only when adequate control of its
mounted.
acoustic performance can be provided.
7.2.4 Flange mountings that are as small as prac-
7.4.8 All fluid lines and load valves in the test
tical shall be used so as to minimize interference
space shall be wrapped with sound-isolating ma-
with radiation of sound towards the shaft end of the
terials, if required (see 10.1). Material having a
pump.
sound-transmission loss of at least 10 dB at 125 Hz,
and a greater loss at higher frequencies, shall be
7.3 Pump drive
used.
The drive motor shall be located outside the test
space and the pump shall be driven through flexible
couplings and an intermediate shaft, or the motor
8 Operating conditions
shall be isolated in an acoustic enclosure.
8.1 Determine the sound power levels of the pump
7.4 Hydraulic circuit
(see annex A) for any desired set of operating con-
ditions (see 11.3.7).
7.4.1 The circuit shall include all oil filters, oil
coolers, reservoirs and restrictor valves as required
to meet the pump hydraulic operating conditions
8.2 These test conditions shall be maintained
(see clause 8).
throughout the test within the limits given in table 2.
7.4.2 The test fluid and degree of filtration shall be
Table 2 - Allowable variations of mean indicated
in accordance with the pump manufacturer ’s rec-
values of controlled parameters
ommendations.
Test parameter Allowable variation
7.4.3 Inlet and discharge lines shall be installed
with diameters in accordance with the manufac-
Flow +2 %
-
turers’ recommended practice. Extra care shall be
Pressure +2 O/o
-
exercised when assembling inlet lines to prevent air
leaking into the circuit. 3-2 %
Speed
-
Temperature +2 “C
-
7.4.4 The inlet pressure gauge shall be mounted
at the same height as the inlet fittings or it shall be
calibrated for any height difference.
tested in the
8.3 The shall be
pump
7.4.5 The length of line between the pump and the “as-delivered” condition with any ancillary pumps
load valve shall be selected in order to minimize the and valves operating normally during the test, so as
effect of standing waves in the discharge line which to include their noise contributions to the airborne
can increase the sound radiated from the pump. At noise level of the pump.

---------------------- Page: 9 ----------------------

SIST ISO 4412-1:1998
IS0 4412-1:1991(E)
Measure the following for each test:
9 Location and number of sound
measurement points
a) pump speed and flow rate;
The location and number of measurement points
b) fluid temperature and pressure at pump inlet and
shall be as required by IS0 3744 for the method of
fluid pressure at discharge fittings or at the test
measurement selected for the pump noise test.
point provided by the pump manufacturer;
10 Test procedure c) band sound pressure levels at each measure-
ment point over the frequency range of interest;
10.1 Background noise measurements
d) A-weighted sound pressure level at each
measurement point.
10.1.1 Measure the background noise of interest
that is present during the pump noise test which
10.2.2 New or rebuilt pumps
does not emanate from the pump itself.
Over the frequency range of interest, the band
10.2.2.1 Repeat the initial pump measurement test
sound pressure levels of this background noise shall
of the series at the end of a test series or after 1 h
be at least 6 dB below the pump band sound press-
of testing.
ure levels at each measurement point.
10.2.2.2 If the A-weighted sound level at any selec-
10.1.2 Correct for this background noise, if evi-
ted measurement point does not duplicate that of
denced by these measurements, by applying the
the first test within 2 dB (A), the whole test series
corrections for this purpose given in IS0 3744.
shall be invalidated.
10.1.3 When measurement of band levels of back-
ground noise is not practical, the A-weighted back- II Information to be recorded
ground sound level of each measurement point shall
be at least 6 dB below the pump A-weighted sound
11 .l Specifications
level.
The information given in 11.2 and 11.3 shall be
Correct these A-weighted measurements for back-
compiled and recorded for all measurements made
ground noise.
according to the requirements of this part of
NOTES
IS0 4412.
7 Easing the requirements for background noise levels
can lead to an overestimate of the pump band sound 11.2 General information
pressure levels.
name and address of the pump manufacturer
a)
8 The A-weighted background sound level at each
and, if applicable, the user;
measurement point may be checked by covering the
pump with sound-insulating materials capable of a trans-
reference number(s) for identification of the
b)
mission loss of at least 10 dB over the frequency range
pump;
which is “determining” the A-weighted sound level of the
pump*
name and address of persons or organization
Cl
responsible for the acoustic tests on the pump;
10.1.4 If the background level is found to be too
high, check for further noise control of the pump
date and place of acoustic tests;
d)
mounting, drive or hydraulic circuit, as indicated.
statement that the sound power levels of the
e)
10.1.5 Ensure that the orientation of the micro-
pump have been obtained in full conformance
phone and the period of observation are as specified
with this part of IS0 4412 and IS0 3744 for the
in IS0 3744.
determination of sound power levels of noise
sources (see also clause 13).
10.2 Pump measurements
11.3 Pump under test
10.2.1 Measurement sequence
Prior to commencement of a series of tests, operate 11.3.1 Description of pump
the pump for a sufficient time to purge air from the
system and to stabilize all variables, including fluid a) type of pump (e.g. gear or piston), including an-
condition, to within the limits specified in table 2. cillary equipment;
4

---------------------- Page: 10 ----------------------

SIST ISO 4412-1:1998
IS0 4412-1:1991(E)
b) type of displacement (e.g. fixed or variable); 11.3.5.2 Show on this sketch the location of other
reflecting or absorbing screens and noise sources
overa II linear dimensions (with sketch if which can influence measurements.
Cl pump
neces
sat-y);
1 I .3.6 Instrumentation
d) pump maximum displacement;
a) details of equipment used to monitor pump op-
e) type of displacement controller and setting.
erating conditions (see 11.3.7), including type,
serial number and manufacturer;
11.3.2 Acoustic environment for tests
b) details of equipment used for acoustic measure-
a) internal dimensions of the test room and the type
ments including name, type, serial number and
of acoustic field for the measurements (e.g. free
manufacturer;
field over a reflecting plane);
c) bandwidth of frequency analyser;
b) the acoustical treatment of the test room;
d) overall frequency response of instrumentation
c) the date of measurement;
system and date and method of calibration;
d) ambient air temperature (in degrees Celsius),
e) method of calibration of microphones and date
relative humidity (in percentage) and barometric
and place of calibration.
pressure (in pascats ”));
results of acoustic al qualifica tion of test environ-
e)
11.3.7 Pump operating conditions
required b y clause 5.
ments as
Include the following details for each test:
11.3.3 Reference sound source (when applicable)
a) full description of fluid, including classification in
a) manufacturer, type and serial number;
accordance with IS0 6743-4;
b) sound power level calibration data, including
b) fluid viscosity classification in accordance with
name of calibrating laboratory and date of cali-
IS0 3448, in centistokes or in square millimetres
bration.
per second5);
11.3.4 Mounting and installation conditions of pump
c) shaft speed, in revolutions per minute;
a) description of pump mounting conditions;
d) inlet pressure, in megapascals (bar9));
nature and ch aracterist its of the hydraulic circu it
b)
e) outlet pressure, in megapascals (bars);
and details of any acou stic insul ation treatment
(flow) eithe r measured or calcu-
delivery
9 pump
c) nature and description of other machines being
lated, in litres per mi nute;
used which could have an influence on the
measured sound pressure levels of the pump.
g) temperature of fluid at pump inlet, in degrees
Celsius.
Location of pump in test environment
11.3.5
11.3.8 Acoustical data
11.3.5.1 Include a sketch showing the location of
the pump in relation to walls, floor and ceiling of the
Include all data as required by IS0 3744.
test room.
= 10-S bar
4) 1 Pa
5) 1 cst =
1 mm ’ls
= 105 N/m2 = 105 Pa = 0,l MPa
6) 1 bar
5

---------------------- Page: 11 ----------------------

SIST ISO 4412-1:1998
IS0 4412-1:1991(E)
paragraphs of IS0 3744 for the determination of
12 Test report
sound power levels of noise sources.
The test report shall contain the following infor-
mation:
13 Identification statement (Reference to
this part of IS0 4412)
a) the A-weighted sound power level and octave
band sound power levels for each frequency
Use the following statement in test reports, cata-
band of interest for each set of operating con-
logues and sales literature when electing to comply
ditions;
with this part of IS0 4412:
b) a statement that the sound power levels have
“Airborne noise levels determined in accordance
been obtained in full conformance with the pro-
with IS0 4412-1, Hydraulic #7uid power- - Test code
cedures of this part of IS0 4412 and specific
for determination of airborne noise levels - Part I:
Pumps ”.

---------------------- Page: 12 ----------------------

SIST ISO 4412-1:1998
IS0 4412=1:1991(E)
Annex A
(normative)
Calculation of sound levels
A.1 Calculation of pump mean sound A.2 Calculation of mean sound pressure
pressure levels and sound power levels
level at a reference distance
The mean sound pressure level at a distance Y, in
A.l.1 Refer to IS0 3744 for information regarding
metres, from the equivalent point source radiating
corrections to be applied and the method of calcu-
into a free field over a reflecting plane (hemi-
lating the mean levels and the pump sound power
spherical radiation) from the calculated pump sound
levels.
power level is evaluated as follows:
A.l.2 Correct the measured band sound pressure
levels (and A-weighted sound levels, where appro-
priate) at each measurement position for the meas-
where
background
ured noise (background noise
corrections).
/ is the mean sound pressure level, A-
“P
weighted or in bands, in decibels (refer-
ence: 20 pPa);
A.l.3 Use these corrected levels to calculate the
pump mean band sound levels and mean A-
I is the A-weighted or band power level of
‘W
weighted sound level.
the pump under test, in decibels (refer-
ence: 1 pW);
A.l.4 Calculate the pump sound power level from
these mean sound pressure levels, taking into ac-
2nP2 is the area of the hemisphere, in square
count any correction for unwanted environmental
metres, of radius r;
reflections (environmental correction factor).
c = 1 m*.
co
For calculation purposes, choose a reference dis-
= 1 m, in which case the numerical value
tance of Y
of r., is obtained by subtracting 8 dB from the nu-
merrcal value of the calculated sound power level,

---------------------- Page: 13 ----------------------

SIST ISO 4412-1:1998
IS0 4412=1:1991(E)
Annex B
(normative)
Errors and classes of measurement
6.1 Classes of measurement
Table B.l - Permissible systematic errors of
measuring instruments as determined during
Depending on the accuracy required, the tests may
calibration
be carried out to one of three classes of measure-
I I I I
ment, A, B or C. The classes of measurement shall
Class of
1 Units 1 A 1 B 1 C
be agreed between the parties concerned. The use
measurement
of class A and B is restricted to special cases when
there is a need to have the performance more pre-
+ 1,5 + 2,5
Input signal O/o + 0,5 -
- -
cisely defined. Class A and B tests require more
Flow % +0,5 + 1,5
- Z!SV
-
accurate apparatus and methods, which may in-
Pressure % +0,5 + 1,5 + 2,5
- - -
crease the costs of such tests.
Temperature OC +0,5 + l,o + 2,0
- - -
Speed O/a + 0,5 + 1,o + 2,0
B .2 Errors - - -
Any device or method which by calibration or com-
parison with International Standards has been dem-
NOTE - The percentage limits given are of the value
of the quantity being measured and not of the maxi-
onstrated to be capable of measuring with
mum values of the test or the maximum reading of the
systematic errors not exceeding the limits given in
instrument.
tableB.1 may be used.

---------------------- Page: 14 ----------------------

SIST ISO 4412-1:1998
IS0 4412-1:1991(E)
Annex C
(informative)
Guidelines for the application of this part of IS0 4412
but not an exact measure, of its overall acoustic
C.l Introduction
performance.
This annex describes a series of recommended
techniques that are designed to enable reliable
Pressure llne
measurements of hydraulic pump airborne noise to
be taken, using an anechoic chamber, in accordance
- Bell houslng
with this part of IS0 4412. /
Drive motor
-L I
a-- 7
C.2 General
--W
e-- 4
H/I
4 A 1 I A 4 1
411
This annex should be read in conjunction with
I : 1 f-I1 I I ;
I
d
IS0 2204 and IS0 3744.
The principle of this part of IS0 4412 is based on
measurements taken over a hemispherical surface
centred over the pump unit under test. It does,
however, present certain operational difficulties. The
methods outlined in this annex represent a practical
solution to these problems and allow compliance
with the requirements of this part of IS0 4412.
In a hydraulic installation, the vibrational energy of
the pump becomes distributed among other compo-
nents in the system, such as the connecting pipe-
work, the pump mounting, the drive shaft and the
prime mover. This distribution of energy is a
L- Return llne
characteristic of the particular installation and is not
inherently a measure of pump noise. The pump,
Key
however, produces sound energy which can cause
--- Alrborne noke
the installation as a whole to emit noise. FigureC.1
_ Fluid-borne noise
illustrates the mechanism. It is the objective of this
- Structure-borne noise
annex to ensure that the measured noise is that
radiated by the external casing of the pump and
Figure C.l - Transmission paths of sound energy
nothing else. This component of noise will then be
from pumps
genuinely a characteristic of the pump and as little
affected as possible by the particular installation.
The total airborne noise of a practical installation
includes radiation from all the components of the
C.3 Choice of measurement environment
hydraulic system. These are excited, in the main, by
pump-generated fluid-borne noise (pressure ripple)
This part of IS0 4412 permits measurement in a
present in the circuit and by structural transmission
reverberant or an anechoic room. The anechoic
of vibration from the pump to attached components.
room may take the form of a fully free-field environ-
ment or a free field over a single reflecting plane,
These mechanisms may well predominate in the
termed a (‘semi-anechoic chamber ”.
generation of total system noise. It is found, how-
ever, that low airborne noise radiation from the
An anechoic or semi-anechoic room is normally
pump casing tends to be associated wi
...

ISO
NORME
INTERNATIONALE 44124
Deuxième 6dition
199 1-08-l 5
Transmissions hydrauliques - Code d’essai
pour la détermination du niveau de bruit
aérien -
Partie 1:
Pompes
Hydraulic fluid power - Test code for determination of airborne noise
levels -
Part 1: Pumps

:
Numéro de référence
ISO 4412-1:1991(F)

---------------------- Page: 1 ----------------------
ISO 4412~1:1991 (F)
Sommaire
Page
1 Domaine d’application . 1
2 Références normatives . 1
3 Définitions . 2
2
4 Incertitudes sur les mesures .
2
5 Environnement d’essai .
6 Appareillage . 3
7 Conditions d’installation . 3
3
8 Conditions de fonctionnement .
....... 4
9 Emplacement et nombre des points de mesure du bruit
........................................................................ 4
10 Mode opératoire
................................... 5
11 Informations à relever lors des essais
......................................................................... 6
12 Rapport d’essai
13 Phrase d’identification (%férence à la présente partie de
.................................................................................. 6
I’ISO 4412)
Annexes
. . . . . . . . . . . . . .I. 7
A Calcul des niveaux acoustiques
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
B Erreurs et classe de mesurage
C Lignes directrices pour l’application de la présente partie de
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
I’ISO 4412
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
D Bibliographie
0 ISO 1991
Droits de reproduction réservés. Aucune partie de cette publication ne peut être repro-
duite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou
mécanique, y compris la photocopie et les microfilms, sans l’accord écrit de l’éditeur.
Organisation internationale de normalisation
Case Postale 56 l CH-121 1 Genève 20 l Suisse
Imprimé en Suisse
ii

---------------------- Page: 2 ----------------------
ISO 4412-1:1991(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération
mondiale d’organismes nationaux de normalisation (comités membres
de I’ISO). L’élaboration des Normes internationales est en général
confiée aux comités techniques de I’ISO. Chaque comité membre inté-
ressé par une étude a le droit de faire partie du comité technique créé
à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO participent également aux tra-
vaux. L’ISO collabore étroitement avec la Commission électrotechnique
internationale (CEI) en ce qui concerne la normalisation électrotech-
nique.
Les projets de Normes internationales adoptés par les comités techni-
ques sont soumis aux comités membres pour vote. Leur publication
comme Normes internationales requiert l’approbation de 75 % au moins
des comités membres votants.
La Norme internationale ISO 4412-1 a été élaborée conjointement par
les comités techniques ISO/TC 131, Transmissions hydrauliques et
pneumatiques, sous-comité SC 8, Essais des produits et contrôle de la
contamination et ISO/TC 43, Acoustique.
Cette deuxième edition annule et remplace la première édition (ISO
4412-1:1979), dont les articles 12 et 13 ont été transférés en annexe pour
former la nouvelle annexe A, l’ancienne annexe devenant l’annexe B,
et les annexes C et D ont été ajoutées.
L’ISO 4412 comprend les parties suivantes, présentées sous le titre gé-
néral Transmissions hydrauliques - Code d’essai pour la détermination
du niveau de bruit aérien:
- Partie 1: Pompes
-- Partie 2: Moteurs
- Partie 3. Pompes - Méthode employant un étalage des micro-
phones en parallélépipède
Les annexes A et B font partie intégrante de la présente partie de I’ISO
4412. Les annexes C et D sont données uniquement à titre d’information.
. . .
Ill

---------------------- Page: 3 ----------------------
ISO 4412-1:1991(F)
Introduction
Dans les systèmes de transmissions hydrauliques, l’énergie est trans-
mise et commandée par un iiquide sous pression circulant en circuit
fermé. Les pompes sont des machines qui transforment la puissance
mécanique rotative en puissance hydraulique. Pendant le processus de
transformation de la puissance mécanique en puissance hydraulique, la
pompe émet des bruits qui sont transmis par l’air et des vibrations qui
sont transmises d’une part par le fluide et d’autre part par la structure.
Le niveau de bruit aérien émis par une pompe de transmission hydrau-
lique est un élément important du choix d’un de ces appareils, et la
technique utilisée pour mesurer le bruit doit donc donner une évaluation
précise du niveau de bruit. Les interactions qui interviennent au cours
des mesurages compliquent la détermination des niveaux de bruit. Les
vibrations de la pompe transmises par le fluide et la structure peuvent
se communiquer au circuit et finalement provoquer un bruit de fond
aérien susceptible d’affecter le mesurage du niveau de bruit aérien
émis par la pompe.
Les méthodes décrites dans la présente partie de I’ISO 4412 sont pré-
vues exclusivement pour le mesurage du bruit aérien émis directement
par la pompe mise à l’essai.

---------------------- Page: 4 ----------------------
ISO 4412-1:1991(F)
NORME INTERNATIONALE
Transmissions hydrauliques - Code d’essai pour la
détermination du niveau de bruit aérien -
Partie 1:
Pompes
2 Références normatives
1 Domaine d’application
La présente partie de I’ISO 4412 établit un code
d’essai décrivant des méthodes basées sur
Les normes suivantes contiennent des dispositions
I’ISO 2204, permettant de déterminer les niveaux de
qui, par suite de la référence qui en est faite,
puissance acoustique des pompes pour transmis-
constituent des dispositions valables pour la pré-
sions hydrauliques dans des conditions définies
sente partie de I’ISO 4412. Au moment de la publi-
d’installation et de fonctionnement. Ces méthodes
cation, les éditions indiquées étaient en vigueur.
doivent fournir une base de comparaison valable
Toute norme est sujette à révision et les parties
des niveaux de bruit émis par les pompes, traduits
prenantes des accords fondés sur la présente partie
en termes de
de I’ISO 4412 sont invitées à rechercher la possi-
bilité d’appliquer les éditions les plus récentes des
-
niveau de puissance acoustique, pondéré A;
normes indiquées ci-après. Les membres de la CEI
et de I’ISO possèdent le registre des Normes inter-
- niveaux de puissance acoustique par bande
nationales en vigueur à un moment donné.
d’octave.
ISO 3448:1975, Lubrifiants liquides industriels -
Ces niveaux de puissance acoustique permettent de
Classification ISO selon la viscosité.
calculer si nécessaire les niveaux de pression
acoustique de référence devant figurer dans les
ISO 3744:1981, Acoustique - Détermination des ni-
rapports d’essai conformément à l’annexe A.
veaux de puissance acoustique émis par les sources
de bruit - Méthodes d’expertise pour les conditions
En général, la gamme des fréquences utiles com-
de champ libre au-dessus d’un plan rénéchissant.
prend les bandes d’octave dont les fréquences mé-
dianes s’échelonnent de 125 Hz à 8000 HZ?
ISO 3745:1977, Acoustique - Détermination des ni-
veaux de puissance acoustique émis par les sources
Des lignes directrices pour l’application de la pré-
de bruit - Méthodes de laboratoire pour les salles
sente partie de I’ISO 4412 sont données dans I’an-
anéchoïque et semi-anéchoïque.
nexe C.
ISO 5598: 1985, Transmissions hydrauliques et pneu-
La présente partie de I’ISO 4412 est applicable à
matiques - Vocabulaire.
tous les types de pompes hydrauliques, quelle que
soit leur taille, fonctionnant dans des conditions
ISO 6743-4:1982, Lubrifiants, huiles industrielles et
stables spécifiées, sauf si une limite est imposée
produits connexes - Classe L - Classification -
par les dimensions de la salle d’essais (voir
Partie 4: Famille H (Systèmes hydrauliques).
article 5).
1) 1 Hz = 1 s--l

---------------------- Page: 5 ----------------------
ISO 4412-1:1991(F)
CEI 50(801): 1984, Vocabulaire Électrotechnique d’octave déterminée. La pression acoustique de référence
est de 20 pPa2).
In terna tional - Chapitre 801: Acoustique et électro-
acoustique.
3.7 niveau de puissance acoustique: Dix fois le
logarithme décimal du rapport d’une puissance
CEI 651:1979, Sonomètres.
acoustique donnée à la puissance acoustique de
référence, en décibels.
3 Définitions
NOTE 4 Le réseau de pondération ou la largeur de la
bande fréquence utilisés devraient toujours être indiqués.
Pour les besoins de la présente partie de I’ISO 4412,
La puissance acoustique de référence est 1 pW3).
les définitions données dans I’ISO 5598, la CEI 50 et
les définitions suivantes s’appliquent. II est admis
3.8 volume de la source acoustique en essai: Vo-
que les définitions données ci-après peuvent différer
lume de l’enveloppe de la pompe compléte en es-
de celles utilisées dans d’autres Normes internatio-
sai.
nales spécifiques.
4 Incertitudes sur les mesures
3.1 champ acoustique libre: Champ acoustique
dans un milieu homogène isotrope sans limite.
Il convient d’utiliser des méthodes de mesurage
donnant des écarts-types égaux ou inférieurs aux
NOTE 1 En pratique, c’est un champ dans lequel les ef-
valeurs du tableau 1. L’ISO 3744 satisfait à cette
fets des conditions aux limites sont négligeables dans
exigence.
toute la gamme des fréquences intéressantes.
3.2 champ libre sur un plan réfléchissant: Champ Tableau 1 - Écarbtypes dans la détermination du
produit par une source en présence d’un plan réflé-
niveau de puissance acoustique
chissant sur lequel la source est placée.
Écart-type, dB,
pour bandes d’octave de fréquence médiane
3.3 champ acoustique réverbéré: Partie du champ
acoustique existant dans une salle d’essai pour la-
125Hz j 25OHz 15OOHz / ‘:;;;;; / 8OOOHz
quelle l’influence du son recu directement de la
source est négligeable. ’
TO zo 290 370
50
3.4 salle anéchoïque: Salle d’essai dont les parois
absorbent totalement l’énergie acoustique incidente
Les écarts-types du tableau 1 tiennent compte des
dans la gamme des fréquences intéressantes, four-
effets des variations admissibles du positionnement
nissant ainsi des conditions de champ libre sur toute
des points de mesure, ainsi que de la sélection de
la surface de mesure.
la surface de mesure prescrite, quelle qu’elle soit,
mais ne tiennent pas compte des variations d’un
3.5 pression acoustique quadratique moyenne:
essai à l’autre de la puissance acoustique rayonnée
Pression acoustique moyennée quadratiquement
par la source.
dans l’espace et dans le temps.
NOTE 5 Le niveau de puissance acoustique pondéré A
NOTE 2 En pratique, cette pression est évaluée par
sera, dans la plupart des cas pratiques, déterminé avec
moyennage dans l’espace et dans le temps sur une tra-
un écart-type d’environ 2 dB.
jectoire finie ou sur un certain nombre de positions fixes
des microphones.
5 Environnement d’essai
3.6 niveau moyen de pression acoustique: Dix fois
Les essais doivent être effectués dans un environ-
le logarithme décimal du rapport de la pression
nement fournissant des conditions de (champ libre
acoustique quadratique moyenne au carré de la
sur un plan réfléchissant,) conformes aux exigences
pression acoustique de référence, en décibels (dB).
de qualification des méthodes d’essai (prescrites
NOTE 3 Le réseau de pondération ou la largeur de la dans I’ISO 3744:1981, article 4 et annexe A).
bande de fréquence utilisés devraient toujours être indi-
Pour des mesures plus précises, les essais doivent
qués, par exemple, niveau de pression acoustique pon-
déré A, niveau de pression acoustique dans une bande être effectués conformément à I’ISO 3745.
2) 1 PPa = 10-S Nlm*
3) 1 pw - 10-12 w
2

---------------------- Page: 6 ----------------------
ISO 4412-1:1991(F)
7.4 Circuit hydraulique
6 Appareillage
7.4.1 Le circuit doit comprendre tous les filtres, re-
6.1 Les appareils de mesure du débit, de la pres-
réservoirs et valves d’étranglement
froidisseurs,
sion et de la température du fluide, ainsi que de la
nécessaires au bon fonctionnement de la pompe
vitesse de rotation, doivent être conformes aux re-
(voir article 8).
commandations pour la classe C de précision c&+
dustrielle,,, donnée dans l’annexe B.
degré de filtration
7.4.2 Le fluide d’essai et son
spécifications du
correspondre aux
doivent
constructeur de la pompe.
6.2 Les appareils de mesure acoustique doivent
être conformes aux prescriptions de la CEI 651. Ces
7.4.3 Les diamètres des tuyauteries d’aspiration et
appareils doivent être conformes à I’ISO 3744 tant
d’écoulement doivent être conformes aux pratiques
pour les caractéristiques que pour l’étalonnage
d’installation recommandées par le constructeur.
(c’est-à-dire les appareils de mesure technique de
Un soin particulier devra être apporté à I’assem-
classe 2).
blage des tuyauteries d’aspiration pour éviter I’en-
trée d’air dans le circuit.
7 Conditions d’installation
7.4.4 Le manomètre mesurant la pression d’entrée
doit être monté à la même hauteur que l’orifice
d’aspiration ou doit être étalonné en tenant compte
7.1 Emplacement de la pompe
de toute différence de hauteur.
La pompe peut être placée en n’importe quel en-
7.4.5 La longueur de la tuyauterie entre la pompe
droit compatible avec les recommandations d’ins-
et la soupape de mise en charge doit être choisie
tallation des sources et des surfaces de mesure (ou
de manière à réduire au minimum le risque qu’une
des positions de microphone) figurant dans
onde stationnaire ne se crée dans la tuyauterie, ce
I’ISO 3744 pour l’essai de milieu employé.
qui pourrait augmenter le bruit émis par la pompe.
Au moins 15 m de conduite doivent être utilisés pour
satisfaire cette exigence.
7.2 Montage de la pompe
7.4.6 Une soupape de mise en charge stable doit
7.2.1 Le banc d’essai doit être construit de manière
être utilisée.
à réduire au minimum le bruit émis par le montage
par suite des vibrations de la pompe.
NOTE 6 Des soupapes de mise en charge instables
montées sur la tuyauterie de refoulement peuvent pro-
duire et transmettre, par l’intermédiaire du fluide et des
7.2.2 Le support de montage doit être réalisé en
tuyauteries, des bruits semblant provenir de la pompe.
matériau à haut pouvoir d’amortissement ou être
recouvert de matériau d’amortissement ou d’iso-
7.4.7 La soupape doit être placée loin de la pompe,
lation phonique.
de préférence hors de la salle d’essai, pour réduire
au minimum l’interaction. La soupape ne doit être
7.2.3 Des techniques d’isolation doivent, s’il y a
placée à proximité de la pompe que si ses caracté-
lieu, être employées contre les vibrations, même si
ristiques acoustiques peuvent être convenablement
la pompe est ordinairement montée de manière ri- contrôlées.
gide.
7.4.8 Toutes les tuyauteries et soupapes de mise
en charge situées dans la salle d’essai seront au
7.2.4 La taille des flasques de montage doit être
besoin enveloppées de matériau d’isolation
aussi réduite que possible, en vue de réduire I’in-
phonique (voir 10.1). À cet effet, des matériaux pro-
terference avec le bruit émis vers le bout d’arbre de
voquant une perte de transmission du son d’au
la pompe.
moins 10 dB à 125 Hz, et une perte supérieure aux
fréquences plus élevées, doivent être utilisés.
7.3 Entraînement de la pompe
8 Conditions de fonctionnement
Le moteur d’entraînement doit être placé hors de la
salle d’essai et la pompe doit être entraînée par un
8.1 Déterminer les niveaux de puissance acousti-
accouplement flexible et un arbre intermédiaire, ou
que de la pompe (voir annexe A) pour la série de
le moteur doit être isolé dans une enceinte acousti-
conditions de fonctionnement désirée (voir 11.3.7).
que.
3

---------------------- Page: 7 ----------------------
ISO 441201:1991 (F)
NOTES
8.2 Ces conditions d’essai doivent être mainte-
nues pendant toute la durée de l’essai dans les li-
7 Tout assouplissement des exigences concernant les
mites prescrites dans le tableau 2.
niveaux de bruit de fond peut conduire à une suresti-
mation des niveaux de pression acoustique par bande de
la pompe.
Tableau 2 - Écarts admissibles des valeurs
moyennes indiquées des paramètres d’essai
* 8 Le niveau de bruit de fond pondéré A à chaque point
de mesure peut être vérifié en recouvrant la pompe d’un
Paramétres de l’essai Écart admissible
matériau d’isolation phonique provoquant une perte de
transmission d’au moins 10 dB dans la gamme des fré-
Debi t 3-2 %
-
quences qui ~~détermine~~ le niveau de pression acousti-
Pression +2 % que pondéré A de la pompe.
-
Vitesse de rotation +2 %
-
10.1.4 Si le niveau de bruit de fond s’avère trop
Température +2 OC
-
élevé, procéder à des contrôles supplémentaires du
bâti de la pompe, de son entraînement ou du circuit
hydraulique, selon le cas.
8.3 La pompe doit être essayée, dans son état de
livraison avec les pompes ou soupapes auxiliaires
10.1.5 S’assurer que l’orientation du’ microphone
fonctionnant normalement pendant l’essai, de ma-
et la durée de l’observation sont telles que spéci-
niére à inclure leur bruit propre dans le niveau de
fiées dans I’ISO 3744.
bruit aérien émis par la pompe.
10.2 Mesurages sur la pompe
9 Emplacement et nombre des points de
10.2.1 Série de mesurages
mesure du bruit
Avant d’entreprendre une série d’essais, faire fonc-
L’emplacement et le nombre des points de mesure
tionner la pompe suffisamment longtemps pour que
doivent être conformes aux indications de I’ISO 3744
l’air soit totalement évacué du circuit et que toutes
pour la méthode de mesurage choisie pour l’essai
les variables, y compris l’état du fluide, soient sta-
acoustique de la pompe.
bilisées, dans les limites prescrites dans le
tableau 2.
Pour chaque essai, effectuer les mesurages sui-
10 Mode opératoire
vants:
10.1 Mesurage du bruit de fond
a) vitesse de rotation et débit de la pompe;
b) température du fluide et pression à l’entrée de
10.1.1 Mesurer le bruit de fond qui est présent
la pompe, pression à l’orifice de sortie ou au
pendant l’essai acoustique de la pompe, mais qui
n’émane pas de la pompe proprement dite. point d’essai prévu par le constructeur de la
pompe;
Dans la gamme des fréquences intéressantes, les
niveaux de pression acoustique par bande de ce
c) niveau de pression acoustique par bande à cha-
bruit de fond doivent être d’au moins 6 dB inférieur
que point de mesure sur toute la gamme des
au niveau de pression acoustique par bande de la
fréquences intéressantes;
pompe à chaque point de mesure.
d) niveau de pression acoustique pondéré A à cha-
que point de mesure.
10.1.2 Apporter des corrections en fonction du bruit
de fond éventuellement mis en évidence par les
102.2 Pompe neuve ou reconditionnée
mesures, en apportant les corrections prévues à cet
effet fixées dans I’ISO 3744.
10.2.2.1 À la fin de toute série d’essais ou après
1 h d’essai, réitérer les mesurages initiaux de la
10.1.3 Lorsqu’il n’est pas possible de mesurer le
série.
niveau de bruit de fond par bande, le niveau de
pression acoustique pondéré A du bruit de fond doit
10.2.2.2 Si le niveau de pression acoustique pon-
être d’au moins 6 dB inférieur au niveau de pression
déré A en un point quelconque de mesure ne cor-
acoustique pondéré A de la pompe.
respond pas à celui du premier essai, à 2 dB (A)
près, la série complète d’essais doit être annulée.
Corriger ces mesures pondérées A du bruit de fond.
4

---------------------- Page: 8 ----------------------
ISO 4412-1:1991(F)
d) température de l’air ambiant (en degrés
11 Informations à relever lors des essais
Celsius), humidité relative (en pourcentage) et
pression barométrique (en pascals4));
11 .l Spécifications
e) résultats de la qualification acoustique du milieu
Les informations données en 11.2 et en 11.3 doivent d’essai, conformément à l’article 5.
être réunies et consignées par écrit pour tous les
mesurages effectués selon les prescriptions de la
11.3.3 Source sonore de référence (s’il y a lieu)
présente partie de I’ISO 4412.
a) fabricant, type et numéro de série;
11.2 Informations généraies
b) données concernant l’étalonnage du niveau de
puissance acoustique, y compris le nom du la-
nom et adresse du fabricant de la pompe et, s’il
a)
boratoire qui a effectué l’étalonnage et la date
y a lieu, de l’utilisateur;
de l’étalonnage.
numéro(s) de référence pour l’identification de la
W
Il .3.4 Conditions de montage et d’installation de la
pompe;
pompe
nom et adresse des personnes ou de I’orga-
Cl
description des conditions de montage de la
a)
nisme chargés des essais acoustiques de la
pompe;
pompe;
nature et caractéristiques du circuit hydraulique
W
date et lieu des essais acoustiques;
dl
et précisions concernant tout traitement d’iso-
lation phonique;
déclaration établissant que les niveaux de puis-
e)
sance acoustique de la pompe ont été obtenus
nature et description de toutes les autres ma-
C)
en conformité totale avec les prescriptions de la
chines utilisées, susceptibles d’influer sur les
présente partie de I’ISO 4412 et de I’ISO 3744
niveaux mesurés de pression acoustique de la
pour la détermination du niveau de puissance
pompe.
acoustique des sources de bruit (voir également
article 13).
11.3.5
Emplacement de la pompe dans l’enceinte
d’essai
11.3 Pompe en essai
11.3.5.1 Inclure un croquis montrant l’emplacement
II .3.1 Description de la pompe de la pompe par rapport aux murs, au plancher et
au plafond du local d’essai.
type de pompe (par exemple à engrenage ou à
a)
piston), y compris l’équipement auxiliaire;
11.352 Indiquer, en outre, l’emplacement de tout
autre écran réfléchissant ou absorbant et de toute
type de cylindrée (par exemple fixe ou variable);
b) source sonore susceptible d’avoir une incidence sur
les mesures.
cotes d’encombrement de la pompe (au besoin
Cl
avec un croquis);
II .3.6 Appareillage
cylindrée maximale;
dl
a) précisions concernant l’équipement utilisé pour
contrôler les conditions de fonctionnement de la
type de commande de variation de cylindrée et
e)
pompe (voir 11.3.7) y compris le type, le numéro
valeurs de réglage.
de série et le nom du constructeur;
11.3.2 Milieu acoustique d’essai b) précisions concernant l’équipement utilisé pour
les mesurages acoustiques, y compris la dési-
a) dimensions intérieures du local d’essai et type gnation, le type, le numéro de série et le nom du
de champ acoustique utilisés pour les mesures fabricant;
(par exemple champ libre sur plan réfléchissant);
c) largeur de bande de l’analyseur de fréquence;
b) traitement acoustique de la salle d’essai;
d) réponse en fréquence globale des appareils de
c) date du mesurage; mesure; date et méthode d’étalonnage;
4) 1 Pa = 10--s bar

---------------------- Page: 9 ----------------------
ISO 4412-1:1991(F)
e) méthode d’étalonnage des microphones; date et
12 Rapport d’essai
lieu d’étalonnage.
Le rapport d’essai doit contenir les indications sui-
11.3.7 Conditions de fonctionnement de la pompe
vantes:
Pour chaque essai, indiquer les points suivants:
a) le niveau de puissance acoustique pondéré A et
les niveaux de puissance acoustique par bande
a) description complète du fluide, y compris sa
d’octave pour chaque bande de fréquence
classification conformément à I’ISO 6743-4;
concernée et pour chaque série de conditions de
fonctionnement;
b) classification selon la viscosité du fluide confor-
mément à I’ISO 3448, en centistokes ou en milli-
b) une déclaration établissant que les niveaux de
mètres carrés par seconde@;
puissance acoustique ont été obtenus en confor-
mité totale avec les méthodes prescrites dans la
c) vitesse de rotation de l’arbre, en tours par mi-
présente partie de I’ISO 4412 et dans les para-
nute;
graphes appropriés de I’ISO 3744 relative à la
détermination des niveaux de puissance acous-
d) pression d’entrée, en mégapascals (bars@);
tique des sources de bruit.
e) pression de refoulement, en mégapascals (bars);
13 Phrase d’identification (Référence à la
présente partie de VIS0 4412)
f) débit mesuré ou calculé; en litres par minute;
Il est vivement recommandé aux fabricants qui ont
g) température du fluide à l’orifice d’entrée, en de-
choisi de se conformer à la présente partie de
grés Celsius.
I’ISO 4412 d’utiliser dans leurs rapports d’essai, ca-
talogues et documentation commerciale, la phrase
11.3.8 Données acoustiques
d’identification suivante:
Fournir toutes les données requises dans I’ISO 3744.
((Niveaux de bruit aérien déterminés conformément
à I’ISO 4412-1, Transmissions hydrauliques - Code
d’essai pour la détermination du niveau de bruit aé-
rien - Partie 1: Pompes.,,
5) 1 cSt = 1 mm2/s
= 105 Nlm2 = 105 Pa = 0,l MPa
6) 1 bar
6

---------------------- Page: 10 ----------------------
ISO 4412=1:1991(F)
Annexe A
(normative)
Calcul des niveaux acoustiques
A.1 Calcul des niveaux moyens de A.2 Calcul du niveau moyen de pression
pression acoustique et des niveaux de acoustique à une distance de référence
puissance acoustique de la pompe
Le niveau moyen de pression acoustique à une dis-
tance r, en mètres, de la source ponctuelle équiva-
A.1.1 Se référer à I’ISO 3744 pour tous rensei-
lente émettant dans un champ libre sur un plan
gnements concernant les corrections à apporter et
réfléchissant (rayonnement hémisphérique) à partir
la méthode de calcul des niveaux moyens et du ni-
du niveau calculé de puissance acoustique de la
veau de puissance acoustique de la pompe.
pompe est calculé comme suit:
A.l.2 Corriger les niveaux de pression acoustique
par bande mesurée (et, s’il y a lieu, les niveaux
acoustiques pondérés A) pour chaque point de me-
sure, pour tenir compte du bruit de fond mesuré
est le niveau moyen de pression acous-
(correction pour le bruit de fond).
tique, pondéré A ou par bande, en
décibels (référence: 20 pPa);
A.1.3 Au moyen de ces niveaux corrigés, calculer
les niveaux moyens de pression acoustique par
est le niveau de puissance acoustique
bande et le niveau acoustique moyen pondéré A.
pondéré A ou par bande de la pompe en
essai, en décibels (référence: 1 pW);
A.l.4 Grâce à ces niveaux moyens de pression
acoustique, calculer le niveau de puissance acous- est la surface de l’hémisphère, en mè-
tique de la pompe en tenant compte des corrections tres carrés, de rayon r;
nécessitées par les réflexions parasites du milieu
= 1 m*.
d’essai (facteur de correction de site).
En vue de l’établissement des calculs, choisir une
distance de référence Y
= 1 m; ainsi, la valeur nu-
est obtenue en soustrayant 8 dB de
mérique de q
la valeur numérique du niveau de puissance acous-
tique calculé I,,.

---------------------- Page: 11 ----------------------
ISO 4412-1:1991(F)
Annexe B
(normative)
Erreurs et classe de mesurage
B.1 Classes de mesurage
Tableau B.l - Erreurs systématiques admissibles
des appareils de mesure telles que déterminées lors
Selon la précision requise, les essais peuvent être
de l’étalonnage
effectués pour l’une des trois classes de mesurage,
A, B ou C. Les classes de mesurage doivent faire
Classe de
Unités A B C
l’objet d’un accord entre les parties concernées.
mesurage
L’utilisation des classes A et B est réservée aux cas
spéciaux nécessitant une définition plus particulière
Signal d’entrée Oh +0,5 +1,5 +2,5
- - -
de la performance. Les essais des classes A et B
Débit % +0,5 +1,5 +2,5
- - -
exigent l’utilisation d’appareils et de méthodes plus
Oh +0,5 +1,5 +2,5
Pression - - -
précis, ce qui peut entraîner une augmentation du
coût de ces essais. Température OC +0,5 + 1,o +2,0
- - -
Vi tesse Oh +0,5 + l,o +2,0
- - -
B .2 Erreurs
Tout dispositif ou toute méthode qui, par étalonnage NOTE - Les limites en pourcentage indiquées s’appli-
quent à la valeur de la quantité mesurée, et non aux
ou comparaison avec des Normes internationales,
valeurs maximales de l’essai ou à la lecture maximale
ont pu être estimés capables de mesurer avec des
de l’instrument.
erreurs systématiques n’excédant pas les limites
indiquées dans le tableau B-1, peuvent être utilisés.
8

---------------------- Page: 12 ----------------------
ISO 4412=1:1991(F)
Annexe C
(informative)
Lignes directrices pour l’application de la présente partie de I’ISO 4412
faible production de bruits hydrauliques et solidiens.
CA Introduction
Les valeurs obtenues pour le bruit aérien rayonné
par le boîtier de la pompe peuvent donc être consi-
La présente annexe décrit une série de techniques
dérées comme une indication, mais pas comme une
recommandées conques pour effectuer des mesu-
mesure exacte, de sa performance acoustique glo-
rages fiables du bruit aérien des pompes hydrauli-
bale.
ques, en utilisant une salle anéchoique,
conformément à la présente partie de I’ISO 4412.
/----- Conduite sous pression
C.2 Généralités
r Gatne d’iso
...

ISO
NORME
INTERNATIONALE 44124
Deuxième 6dition
199 1-08-l 5
Transmissions hydrauliques - Code d’essai
pour la détermination du niveau de bruit
aérien -
Partie 1:
Pompes
Hydraulic fluid power - Test code for determination of airborne noise
levels -
Part 1: Pumps

:
Numéro de référence
ISO 4412-1:1991(F)

---------------------- Page: 1 ----------------------
ISO 4412~1:1991 (F)
Sommaire
Page
1 Domaine d’application . 1
2 Références normatives . 1
3 Définitions . 2
2
4 Incertitudes sur les mesures .
2
5 Environnement d’essai .
6 Appareillage . 3
7 Conditions d’installation . 3
3
8 Conditions de fonctionnement .
....... 4
9 Emplacement et nombre des points de mesure du bruit
........................................................................ 4
10 Mode opératoire
................................... 5
11 Informations à relever lors des essais
......................................................................... 6
12 Rapport d’essai
13 Phrase d’identification (%férence à la présente partie de
.................................................................................. 6
I’ISO 4412)
Annexes
. . . . . . . . . . . . . .I. 7
A Calcul des niveaux acoustiques
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
B Erreurs et classe de mesurage
C Lignes directrices pour l’application de la présente partie de
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
I’ISO 4412
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
D Bibliographie
0 ISO 1991
Droits de reproduction réservés. Aucune partie de cette publication ne peut être repro-
duite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou
mécanique, y compris la photocopie et les microfilms, sans l’accord écrit de l’éditeur.
Organisation internationale de normalisation
Case Postale 56 l CH-121 1 Genève 20 l Suisse
Imprimé en Suisse
ii

---------------------- Page: 2 ----------------------
ISO 4412-1:1991(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération
mondiale d’organismes nationaux de normalisation (comités membres
de I’ISO). L’élaboration des Normes internationales est en général
confiée aux comités techniques de I’ISO. Chaque comité membre inté-
ressé par une étude a le droit de faire partie du comité technique créé
à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO participent également aux tra-
vaux. L’ISO collabore étroitement avec la Commission électrotechnique
internationale (CEI) en ce qui concerne la normalisation électrotech-
nique.
Les projets de Normes internationales adoptés par les comités techni-
ques sont soumis aux comités membres pour vote. Leur publication
comme Normes internationales requiert l’approbation de 75 % au moins
des comités membres votants.
La Norme internationale ISO 4412-1 a été élaborée conjointement par
les comités techniques ISO/TC 131, Transmissions hydrauliques et
pneumatiques, sous-comité SC 8, Essais des produits et contrôle de la
contamination et ISO/TC 43, Acoustique.
Cette deuxième edition annule et remplace la première édition (ISO
4412-1:1979), dont les articles 12 et 13 ont été transférés en annexe pour
former la nouvelle annexe A, l’ancienne annexe devenant l’annexe B,
et les annexes C et D ont été ajoutées.
L’ISO 4412 comprend les parties suivantes, présentées sous le titre gé-
néral Transmissions hydrauliques - Code d’essai pour la détermination
du niveau de bruit aérien:
- Partie 1: Pompes
-- Partie 2: Moteurs
- Partie 3. Pompes - Méthode employant un étalage des micro-
phones en parallélépipède
Les annexes A et B font partie intégrante de la présente partie de I’ISO
4412. Les annexes C et D sont données uniquement à titre d’information.
. . .
Ill

---------------------- Page: 3 ----------------------
ISO 4412-1:1991(F)
Introduction
Dans les systèmes de transmissions hydrauliques, l’énergie est trans-
mise et commandée par un iiquide sous pression circulant en circuit
fermé. Les pompes sont des machines qui transforment la puissance
mécanique rotative en puissance hydraulique. Pendant le processus de
transformation de la puissance mécanique en puissance hydraulique, la
pompe émet des bruits qui sont transmis par l’air et des vibrations qui
sont transmises d’une part par le fluide et d’autre part par la structure.
Le niveau de bruit aérien émis par une pompe de transmission hydrau-
lique est un élément important du choix d’un de ces appareils, et la
technique utilisée pour mesurer le bruit doit donc donner une évaluation
précise du niveau de bruit. Les interactions qui interviennent au cours
des mesurages compliquent la détermination des niveaux de bruit. Les
vibrations de la pompe transmises par le fluide et la structure peuvent
se communiquer au circuit et finalement provoquer un bruit de fond
aérien susceptible d’affecter le mesurage du niveau de bruit aérien
émis par la pompe.
Les méthodes décrites dans la présente partie de I’ISO 4412 sont pré-
vues exclusivement pour le mesurage du bruit aérien émis directement
par la pompe mise à l’essai.

---------------------- Page: 4 ----------------------
ISO 4412-1:1991(F)
NORME INTERNATIONALE
Transmissions hydrauliques - Code d’essai pour la
détermination du niveau de bruit aérien -
Partie 1:
Pompes
2 Références normatives
1 Domaine d’application
La présente partie de I’ISO 4412 établit un code
d’essai décrivant des méthodes basées sur
Les normes suivantes contiennent des dispositions
I’ISO 2204, permettant de déterminer les niveaux de
qui, par suite de la référence qui en est faite,
puissance acoustique des pompes pour transmis-
constituent des dispositions valables pour la pré-
sions hydrauliques dans des conditions définies
sente partie de I’ISO 4412. Au moment de la publi-
d’installation et de fonctionnement. Ces méthodes
cation, les éditions indiquées étaient en vigueur.
doivent fournir une base de comparaison valable
Toute norme est sujette à révision et les parties
des niveaux de bruit émis par les pompes, traduits
prenantes des accords fondés sur la présente partie
en termes de
de I’ISO 4412 sont invitées à rechercher la possi-
bilité d’appliquer les éditions les plus récentes des
-
niveau de puissance acoustique, pondéré A;
normes indiquées ci-après. Les membres de la CEI
et de I’ISO possèdent le registre des Normes inter-
- niveaux de puissance acoustique par bande
nationales en vigueur à un moment donné.
d’octave.
ISO 3448:1975, Lubrifiants liquides industriels -
Ces niveaux de puissance acoustique permettent de
Classification ISO selon la viscosité.
calculer si nécessaire les niveaux de pression
acoustique de référence devant figurer dans les
ISO 3744:1981, Acoustique - Détermination des ni-
rapports d’essai conformément à l’annexe A.
veaux de puissance acoustique émis par les sources
de bruit - Méthodes d’expertise pour les conditions
En général, la gamme des fréquences utiles com-
de champ libre au-dessus d’un plan rénéchissant.
prend les bandes d’octave dont les fréquences mé-
dianes s’échelonnent de 125 Hz à 8000 HZ?
ISO 3745:1977, Acoustique - Détermination des ni-
veaux de puissance acoustique émis par les sources
Des lignes directrices pour l’application de la pré-
de bruit - Méthodes de laboratoire pour les salles
sente partie de I’ISO 4412 sont données dans I’an-
anéchoïque et semi-anéchoïque.
nexe C.
ISO 5598: 1985, Transmissions hydrauliques et pneu-
La présente partie de I’ISO 4412 est applicable à
matiques - Vocabulaire.
tous les types de pompes hydrauliques, quelle que
soit leur taille, fonctionnant dans des conditions
ISO 6743-4:1982, Lubrifiants, huiles industrielles et
stables spécifiées, sauf si une limite est imposée
produits connexes - Classe L - Classification -
par les dimensions de la salle d’essais (voir
Partie 4: Famille H (Systèmes hydrauliques).
article 5).
1) 1 Hz = 1 s--l

---------------------- Page: 5 ----------------------
ISO 4412-1:1991(F)
CEI 50(801): 1984, Vocabulaire Électrotechnique d’octave déterminée. La pression acoustique de référence
est de 20 pPa2).
In terna tional - Chapitre 801: Acoustique et électro-
acoustique.
3.7 niveau de puissance acoustique: Dix fois le
logarithme décimal du rapport d’une puissance
CEI 651:1979, Sonomètres.
acoustique donnée à la puissance acoustique de
référence, en décibels.
3 Définitions
NOTE 4 Le réseau de pondération ou la largeur de la
bande fréquence utilisés devraient toujours être indiqués.
Pour les besoins de la présente partie de I’ISO 4412,
La puissance acoustique de référence est 1 pW3).
les définitions données dans I’ISO 5598, la CEI 50 et
les définitions suivantes s’appliquent. II est admis
3.8 volume de la source acoustique en essai: Vo-
que les définitions données ci-après peuvent différer
lume de l’enveloppe de la pompe compléte en es-
de celles utilisées dans d’autres Normes internatio-
sai.
nales spécifiques.
4 Incertitudes sur les mesures
3.1 champ acoustique libre: Champ acoustique
dans un milieu homogène isotrope sans limite.
Il convient d’utiliser des méthodes de mesurage
donnant des écarts-types égaux ou inférieurs aux
NOTE 1 En pratique, c’est un champ dans lequel les ef-
valeurs du tableau 1. L’ISO 3744 satisfait à cette
fets des conditions aux limites sont négligeables dans
exigence.
toute la gamme des fréquences intéressantes.
3.2 champ libre sur un plan réfléchissant: Champ Tableau 1 - Écarbtypes dans la détermination du
produit par une source en présence d’un plan réflé-
niveau de puissance acoustique
chissant sur lequel la source est placée.
Écart-type, dB,
pour bandes d’octave de fréquence médiane
3.3 champ acoustique réverbéré: Partie du champ
acoustique existant dans une salle d’essai pour la-
125Hz j 25OHz 15OOHz / ‘:;;;;; / 8OOOHz
quelle l’influence du son recu directement de la
source est négligeable. ’
TO zo 290 370
50
3.4 salle anéchoïque: Salle d’essai dont les parois
absorbent totalement l’énergie acoustique incidente
Les écarts-types du tableau 1 tiennent compte des
dans la gamme des fréquences intéressantes, four-
effets des variations admissibles du positionnement
nissant ainsi des conditions de champ libre sur toute
des points de mesure, ainsi que de la sélection de
la surface de mesure.
la surface de mesure prescrite, quelle qu’elle soit,
mais ne tiennent pas compte des variations d’un
3.5 pression acoustique quadratique moyenne:
essai à l’autre de la puissance acoustique rayonnée
Pression acoustique moyennée quadratiquement
par la source.
dans l’espace et dans le temps.
NOTE 5 Le niveau de puissance acoustique pondéré A
NOTE 2 En pratique, cette pression est évaluée par
sera, dans la plupart des cas pratiques, déterminé avec
moyennage dans l’espace et dans le temps sur une tra-
un écart-type d’environ 2 dB.
jectoire finie ou sur un certain nombre de positions fixes
des microphones.
5 Environnement d’essai
3.6 niveau moyen de pression acoustique: Dix fois
Les essais doivent être effectués dans un environ-
le logarithme décimal du rapport de la pression
nement fournissant des conditions de (champ libre
acoustique quadratique moyenne au carré de la
sur un plan réfléchissant,) conformes aux exigences
pression acoustique de référence, en décibels (dB).
de qualification des méthodes d’essai (prescrites
NOTE 3 Le réseau de pondération ou la largeur de la dans I’ISO 3744:1981, article 4 et annexe A).
bande de fréquence utilisés devraient toujours être indi-
Pour des mesures plus précises, les essais doivent
qués, par exemple, niveau de pression acoustique pon-
déré A, niveau de pression acoustique dans une bande être effectués conformément à I’ISO 3745.
2) 1 PPa = 10-S Nlm*
3) 1 pw - 10-12 w
2

---------------------- Page: 6 ----------------------
ISO 4412-1:1991(F)
7.4 Circuit hydraulique
6 Appareillage
7.4.1 Le circuit doit comprendre tous les filtres, re-
6.1 Les appareils de mesure du débit, de la pres-
réservoirs et valves d’étranglement
froidisseurs,
sion et de la température du fluide, ainsi que de la
nécessaires au bon fonctionnement de la pompe
vitesse de rotation, doivent être conformes aux re-
(voir article 8).
commandations pour la classe C de précision c&+
dustrielle,,, donnée dans l’annexe B.
degré de filtration
7.4.2 Le fluide d’essai et son
spécifications du
correspondre aux
doivent
constructeur de la pompe.
6.2 Les appareils de mesure acoustique doivent
être conformes aux prescriptions de la CEI 651. Ces
7.4.3 Les diamètres des tuyauteries d’aspiration et
appareils doivent être conformes à I’ISO 3744 tant
d’écoulement doivent être conformes aux pratiques
pour les caractéristiques que pour l’étalonnage
d’installation recommandées par le constructeur.
(c’est-à-dire les appareils de mesure technique de
Un soin particulier devra être apporté à I’assem-
classe 2).
blage des tuyauteries d’aspiration pour éviter I’en-
trée d’air dans le circuit.
7 Conditions d’installation
7.4.4 Le manomètre mesurant la pression d’entrée
doit être monté à la même hauteur que l’orifice
d’aspiration ou doit être étalonné en tenant compte
7.1 Emplacement de la pompe
de toute différence de hauteur.
La pompe peut être placée en n’importe quel en-
7.4.5 La longueur de la tuyauterie entre la pompe
droit compatible avec les recommandations d’ins-
et la soupape de mise en charge doit être choisie
tallation des sources et des surfaces de mesure (ou
de manière à réduire au minimum le risque qu’une
des positions de microphone) figurant dans
onde stationnaire ne se crée dans la tuyauterie, ce
I’ISO 3744 pour l’essai de milieu employé.
qui pourrait augmenter le bruit émis par la pompe.
Au moins 15 m de conduite doivent être utilisés pour
satisfaire cette exigence.
7.2 Montage de la pompe
7.4.6 Une soupape de mise en charge stable doit
7.2.1 Le banc d’essai doit être construit de manière
être utilisée.
à réduire au minimum le bruit émis par le montage
par suite des vibrations de la pompe.
NOTE 6 Des soupapes de mise en charge instables
montées sur la tuyauterie de refoulement peuvent pro-
duire et transmettre, par l’intermédiaire du fluide et des
7.2.2 Le support de montage doit être réalisé en
tuyauteries, des bruits semblant provenir de la pompe.
matériau à haut pouvoir d’amortissement ou être
recouvert de matériau d’amortissement ou d’iso-
7.4.7 La soupape doit être placée loin de la pompe,
lation phonique.
de préférence hors de la salle d’essai, pour réduire
au minimum l’interaction. La soupape ne doit être
7.2.3 Des techniques d’isolation doivent, s’il y a
placée à proximité de la pompe que si ses caracté-
lieu, être employées contre les vibrations, même si
ristiques acoustiques peuvent être convenablement
la pompe est ordinairement montée de manière ri- contrôlées.
gide.
7.4.8 Toutes les tuyauteries et soupapes de mise
en charge situées dans la salle d’essai seront au
7.2.4 La taille des flasques de montage doit être
besoin enveloppées de matériau d’isolation
aussi réduite que possible, en vue de réduire I’in-
phonique (voir 10.1). À cet effet, des matériaux pro-
terference avec le bruit émis vers le bout d’arbre de
voquant une perte de transmission du son d’au
la pompe.
moins 10 dB à 125 Hz, et une perte supérieure aux
fréquences plus élevées, doivent être utilisés.
7.3 Entraînement de la pompe
8 Conditions de fonctionnement
Le moteur d’entraînement doit être placé hors de la
salle d’essai et la pompe doit être entraînée par un
8.1 Déterminer les niveaux de puissance acousti-
accouplement flexible et un arbre intermédiaire, ou
que de la pompe (voir annexe A) pour la série de
le moteur doit être isolé dans une enceinte acousti-
conditions de fonctionnement désirée (voir 11.3.7).
que.
3

---------------------- Page: 7 ----------------------
ISO 441201:1991 (F)
NOTES
8.2 Ces conditions d’essai doivent être mainte-
nues pendant toute la durée de l’essai dans les li-
7 Tout assouplissement des exigences concernant les
mites prescrites dans le tableau 2.
niveaux de bruit de fond peut conduire à une suresti-
mation des niveaux de pression acoustique par bande de
la pompe.
Tableau 2 - Écarts admissibles des valeurs
moyennes indiquées des paramètres d’essai
* 8 Le niveau de bruit de fond pondéré A à chaque point
de mesure peut être vérifié en recouvrant la pompe d’un
Paramétres de l’essai Écart admissible
matériau d’isolation phonique provoquant une perte de
transmission d’au moins 10 dB dans la gamme des fré-
Debi t 3-2 %
-
quences qui ~~détermine~~ le niveau de pression acousti-
Pression +2 % que pondéré A de la pompe.
-
Vitesse de rotation +2 %
-
10.1.4 Si le niveau de bruit de fond s’avère trop
Température +2 OC
-
élevé, procéder à des contrôles supplémentaires du
bâti de la pompe, de son entraînement ou du circuit
hydraulique, selon le cas.
8.3 La pompe doit être essayée, dans son état de
livraison avec les pompes ou soupapes auxiliaires
10.1.5 S’assurer que l’orientation du’ microphone
fonctionnant normalement pendant l’essai, de ma-
et la durée de l’observation sont telles que spéci-
niére à inclure leur bruit propre dans le niveau de
fiées dans I’ISO 3744.
bruit aérien émis par la pompe.
10.2 Mesurages sur la pompe
9 Emplacement et nombre des points de
10.2.1 Série de mesurages
mesure du bruit
Avant d’entreprendre une série d’essais, faire fonc-
L’emplacement et le nombre des points de mesure
tionner la pompe suffisamment longtemps pour que
doivent être conformes aux indications de I’ISO 3744
l’air soit totalement évacué du circuit et que toutes
pour la méthode de mesurage choisie pour l’essai
les variables, y compris l’état du fluide, soient sta-
acoustique de la pompe.
bilisées, dans les limites prescrites dans le
tableau 2.
Pour chaque essai, effectuer les mesurages sui-
10 Mode opératoire
vants:
10.1 Mesurage du bruit de fond
a) vitesse de rotation et débit de la pompe;
b) température du fluide et pression à l’entrée de
10.1.1 Mesurer le bruit de fond qui est présent
la pompe, pression à l’orifice de sortie ou au
pendant l’essai acoustique de la pompe, mais qui
n’émane pas de la pompe proprement dite. point d’essai prévu par le constructeur de la
pompe;
Dans la gamme des fréquences intéressantes, les
niveaux de pression acoustique par bande de ce
c) niveau de pression acoustique par bande à cha-
bruit de fond doivent être d’au moins 6 dB inférieur
que point de mesure sur toute la gamme des
au niveau de pression acoustique par bande de la
fréquences intéressantes;
pompe à chaque point de mesure.
d) niveau de pression acoustique pondéré A à cha-
que point de mesure.
10.1.2 Apporter des corrections en fonction du bruit
de fond éventuellement mis en évidence par les
102.2 Pompe neuve ou reconditionnée
mesures, en apportant les corrections prévues à cet
effet fixées dans I’ISO 3744.
10.2.2.1 À la fin de toute série d’essais ou après
1 h d’essai, réitérer les mesurages initiaux de la
10.1.3 Lorsqu’il n’est pas possible de mesurer le
série.
niveau de bruit de fond par bande, le niveau de
pression acoustique pondéré A du bruit de fond doit
10.2.2.2 Si le niveau de pression acoustique pon-
être d’au moins 6 dB inférieur au niveau de pression
déré A en un point quelconque de mesure ne cor-
acoustique pondéré A de la pompe.
respond pas à celui du premier essai, à 2 dB (A)
près, la série complète d’essais doit être annulée.
Corriger ces mesures pondérées A du bruit de fond.
4

---------------------- Page: 8 ----------------------
ISO 4412-1:1991(F)
d) température de l’air ambiant (en degrés
11 Informations à relever lors des essais
Celsius), humidité relative (en pourcentage) et
pression barométrique (en pascals4));
11 .l Spécifications
e) résultats de la qualification acoustique du milieu
Les informations données en 11.2 et en 11.3 doivent d’essai, conformément à l’article 5.
être réunies et consignées par écrit pour tous les
mesurages effectués selon les prescriptions de la
11.3.3 Source sonore de référence (s’il y a lieu)
présente partie de I’ISO 4412.
a) fabricant, type et numéro de série;
11.2 Informations généraies
b) données concernant l’étalonnage du niveau de
puissance acoustique, y compris le nom du la-
nom et adresse du fabricant de la pompe et, s’il
a)
boratoire qui a effectué l’étalonnage et la date
y a lieu, de l’utilisateur;
de l’étalonnage.
numéro(s) de référence pour l’identification de la
W
Il .3.4 Conditions de montage et d’installation de la
pompe;
pompe
nom et adresse des personnes ou de I’orga-
Cl
description des conditions de montage de la
a)
nisme chargés des essais acoustiques de la
pompe;
pompe;
nature et caractéristiques du circuit hydraulique
W
date et lieu des essais acoustiques;
dl
et précisions concernant tout traitement d’iso-
lation phonique;
déclaration établissant que les niveaux de puis-
e)
sance acoustique de la pompe ont été obtenus
nature et description de toutes les autres ma-
C)
en conformité totale avec les prescriptions de la
chines utilisées, susceptibles d’influer sur les
présente partie de I’ISO 4412 et de I’ISO 3744
niveaux mesurés de pression acoustique de la
pour la détermination du niveau de puissance
pompe.
acoustique des sources de bruit (voir également
article 13).
11.3.5
Emplacement de la pompe dans l’enceinte
d’essai
11.3 Pompe en essai
11.3.5.1 Inclure un croquis montrant l’emplacement
II .3.1 Description de la pompe de la pompe par rapport aux murs, au plancher et
au plafond du local d’essai.
type de pompe (par exemple à engrenage ou à
a)
piston), y compris l’équipement auxiliaire;
11.352 Indiquer, en outre, l’emplacement de tout
autre écran réfléchissant ou absorbant et de toute
type de cylindrée (par exemple fixe ou variable);
b) source sonore susceptible d’avoir une incidence sur
les mesures.
cotes d’encombrement de la pompe (au besoin
Cl
avec un croquis);
II .3.6 Appareillage
cylindrée maximale;
dl
a) précisions concernant l’équipement utilisé pour
contrôler les conditions de fonctionnement de la
type de commande de variation de cylindrée et
e)
pompe (voir 11.3.7) y compris le type, le numéro
valeurs de réglage.
de série et le nom du constructeur;
11.3.2 Milieu acoustique d’essai b) précisions concernant l’équipement utilisé pour
les mesurages acoustiques, y compris la dési-
a) dimensions intérieures du local d’essai et type gnation, le type, le numéro de série et le nom du
de champ acoustique utilisés pour les mesures fabricant;
(par exemple champ libre sur plan réfléchissant);
c) largeur de bande de l’analyseur de fréquence;
b) traitement acoustique de la salle d’essai;
d) réponse en fréquence globale des appareils de
c) date du mesurage; mesure; date et méthode d’étalonnage;
4) 1 Pa = 10--s bar

---------------------- Page: 9 ----------------------
ISO 4412-1:1991(F)
e) méthode d’étalonnage des microphones; date et
12 Rapport d’essai
lieu d’étalonnage.
Le rapport d’essai doit contenir les indications sui-
11.3.7 Conditions de fonctionnement de la pompe
vantes:
Pour chaque essai, indiquer les points suivants:
a) le niveau de puissance acoustique pondéré A et
les niveaux de puissance acoustique par bande
a) description complète du fluide, y compris sa
d’octave pour chaque bande de fréquence
classification conformément à I’ISO 6743-4;
concernée et pour chaque série de conditions de
fonctionnement;
b) classification selon la viscosité du fluide confor-
mément à I’ISO 3448, en centistokes ou en milli-
b) une déclaration établissant que les niveaux de
mètres carrés par seconde@;
puissance acoustique ont été obtenus en confor-
mité totale avec les méthodes prescrites dans la
c) vitesse de rotation de l’arbre, en tours par mi-
présente partie de I’ISO 4412 et dans les para-
nute;
graphes appropriés de I’ISO 3744 relative à la
détermination des niveaux de puissance acous-
d) pression d’entrée, en mégapascals (bars@);
tique des sources de bruit.
e) pression de refoulement, en mégapascals (bars);
13 Phrase d’identification (Référence à la
présente partie de VIS0 4412)
f) débit mesuré ou calculé; en litres par minute;
Il est vivement recommandé aux fabricants qui ont
g) température du fluide à l’orifice d’entrée, en de-
choisi de se conformer à la présente partie de
grés Celsius.
I’ISO 4412 d’utiliser dans leurs rapports d’essai, ca-
talogues et documentation commerciale, la phrase
11.3.8 Données acoustiques
d’identification suivante:
Fournir toutes les données requises dans I’ISO 3744.
((Niveaux de bruit aérien déterminés conformément
à I’ISO 4412-1, Transmissions hydrauliques - Code
d’essai pour la détermination du niveau de bruit aé-
rien - Partie 1: Pompes.,,
5) 1 cSt = 1 mm2/s
= 105 Nlm2 = 105 Pa = 0,l MPa
6) 1 bar
6

---------------------- Page: 10 ----------------------
ISO 4412=1:1991(F)
Annexe A
(normative)
Calcul des niveaux acoustiques
A.1 Calcul des niveaux moyens de A.2 Calcul du niveau moyen de pression
pression acoustique et des niveaux de acoustique à une distance de référence
puissance acoustique de la pompe
Le niveau moyen de pression acoustique à une dis-
tance r, en mètres, de la source ponctuelle équiva-
A.1.1 Se référer à I’ISO 3744 pour tous rensei-
lente émettant dans un champ libre sur un plan
gnements concernant les corrections à apporter et
réfléchissant (rayonnement hémisphérique) à partir
la méthode de calcul des niveaux moyens et du ni-
du niveau calculé de puissance acoustique de la
veau de puissance acoustique de la pompe.
pompe est calculé comme suit:
A.l.2 Corriger les niveaux de pression acoustique
par bande mesurée (et, s’il y a lieu, les niveaux
acoustiques pondérés A) pour chaque point de me-
sure, pour tenir compte du bruit de fond mesuré
est le niveau moyen de pression acous-
(correction pour le bruit de fond).
tique, pondéré A ou par bande, en
décibels (référence: 20 pPa);
A.1.3 Au moyen de ces niveaux corrigés, calculer
les niveaux moyens de pression acoustique par
est le niveau de puissance acoustique
bande et le niveau acoustique moyen pondéré A.
pondéré A ou par bande de la pompe en
essai, en décibels (référence: 1 pW);
A.l.4 Grâce à ces niveaux moyens de pression
acoustique, calculer le niveau de puissance acous- est la surface de l’hémisphère, en mè-
tique de la pompe en tenant compte des corrections tres carrés, de rayon r;
nécessitées par les réflexions parasites du milieu
= 1 m*.
d’essai (facteur de correction de site).
En vue de l’établissement des calculs, choisir une
distance de référence Y
= 1 m; ainsi, la valeur nu-
est obtenue en soustrayant 8 dB de
mérique de q
la valeur numérique du niveau de puissance acous-
tique calculé I,,.

---------------------- Page: 11 ----------------------
ISO 4412-1:1991(F)
Annexe B
(normative)
Erreurs et classe de mesurage
B.1 Classes de mesurage
Tableau B.l - Erreurs systématiques admissibles
des appareils de mesure telles que déterminées lors
Selon la précision requise, les essais peuvent être
de l’étalonnage
effectués pour l’une des trois classes de mesurage,
A, B ou C. Les classes de mesurage doivent faire
Classe de
Unités A B C
l’objet d’un accord entre les parties concernées.
mesurage
L’utilisation des classes A et B est réservée aux cas
spéciaux nécessitant une définition plus particulière
Signal d’entrée Oh +0,5 +1,5 +2,5
- - -
de la performance. Les essais des classes A et B
Débit % +0,5 +1,5 +2,5
- - -
exigent l’utilisation d’appareils et de méthodes plus
Oh +0,5 +1,5 +2,5
Pression - - -
précis, ce qui peut entraîner une augmentation du
coût de ces essais. Température OC +0,5 + 1,o +2,0
- - -
Vi tesse Oh +0,5 + l,o +2,0
- - -
B .2 Erreurs
Tout dispositif ou toute méthode qui, par étalonnage NOTE - Les limites en pourcentage indiquées s’appli-
quent à la valeur de la quantité mesurée, et non aux
ou comparaison avec des Normes internationales,
valeurs maximales de l’essai ou à la lecture maximale
ont pu être estimés capables de mesurer avec des
de l’instrument.
erreurs systématiques n’excédant pas les limites
indiquées dans le tableau B-1, peuvent être utilisés.
8

---------------------- Page: 12 ----------------------
ISO 4412=1:1991(F)
Annexe C
(informative)
Lignes directrices pour l’application de la présente partie de I’ISO 4412
faible production de bruits hydrauliques et solidiens.
CA Introduction
Les valeurs obtenues pour le bruit aérien rayonné
par le boîtier de la pompe peuvent donc être consi-
La présente annexe décrit une série de techniques
dérées comme une indication, mais pas comme une
recommandées conques pour effectuer des mesu-
mesure exacte, de sa performance acoustique glo-
rages fiables du bruit aérien des pompes hydrauli-
bale.
ques, en utilisant une salle anéchoique,
conformément à la présente partie de I’ISO 4412.
/----- Conduite sous pression
C.2 Généralités
r Gatne d’iso
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.