SIST EN 55016-2-1:2005/A1:2005
(Amendment)Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
Specification for radio disturbance and immunity measuring apparatus and methods -- Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
Superseded by EN 55016-2-1:2009
Anforderungen an Geräte und Einrichtungen sowie Festlegung der Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit -- Teil 2-1: Verfahren zur Messung der hochfrequenten Störaussendung (Funkstörungen) und Störfestigkeit - Messung der leitungsgeführten Störaussendung
Spécifications des méthodes et des appareils de mesure des perturbations radioélectriques et de l'immunité aux perturbations radioélectriques -- Partie 2-1: Méthodes de mesure des perturbations et de l'immunité - Mesures des perturbations conduites
Specifikacija za merilne naprave in metode za merjenje radijskih motenj in odpornosti – 2-1. del: Metode za merjenje radijskih motenj in odpornosti – Merjenje motenj po vodnikih (CISPR 16-2-1:2003/A1:2005)
General Information
Relations
Standards Content (Sample)
SLOVENSKI SIST EN 55016-2-
1:2005/A1:2005
STANDARD
november 2005
Specifikacija za merilne naprave in metode za merjenje radijskih motenj in
odpornosti – 2-1. del: Metode za merjenje radijskih motenj in odpornosti –
Merjenje motenj po vodnikih (CISPR 16-2-1:2003/A1:2005)
Specification for radio disturbance and immunity measuring apparatus and
methods – Part 2-1: Methods of measurement of disturbances and immunity –
Conducted disturbance measurements (CISPR 16-2-1:2003/A1:2005)
ICS 17.220.20; 33.100.20 Referenčna številka
SIST EN 55016-2-1:2005/A1:2005(en)
© Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno
---------------------- Page: 1 ----------------------
EUROPEAN STANDARD EN 55016-2-1/A1
NORME EUROPÉENNE
EUROPÄISCHE NORM August 2005
ICS 33.100.10; 33.100.20
English version
Specification for radio disturbance and immunity
measuring apparatus and methods
Part 2-1: Methods of measurement of disturbances and immunity -
Conducted disturbance measurements
(CISPR 16-2-1:2003/A1:2005)
Spécifications des méthodes et des Anforderungen an Geräte und
appareils de mesure des perturbations Einrichtungen sowie Festlegung
radioélectriques et de l'immunité der Verfahren zur Messung der
aux perturbations radioélectriques hochfrequenten Störaussendung
Partie 2-1: Méthodes de mesure (Funkstörungen) und Störfestigkeit
des perturbations et de l'immunité - Teil 2-1: Verfahren zur Messung
Mesures des perturbations conduites der hochfrequenten Störaussendung
(CISPR 16-2-1:2003/A1:2005) (Funkstörungen) und Störfestigkeit -
Messung der leitungsgeführten
Störaussendung
(CISPR 16-2-1:2003/A1:2005)
This amendment A1 modifies the European Standard EN 55016-2-1:2004; it was approved by CENELEC
on 2005-08-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this amendment the status of a national standard without any
alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 55016-2-1:2004/A1:2005 E
---------------------- Page: 2 ----------------------
EN 55016-2-1:2004/A1:2005 - 2 -
Foreword
The text of document CISPR/A/582/FDIS, future amendment 1 to CISPR 16-2-1:2003, prepared by
CISPR SC A, Radio-interference measurements and statistical methods, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 to
EN 55016-2-1:2004 on 2005-08-01.
The following dates were fixed:
– latest date by which the amendment has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2006-05-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2008-08-01
__________
Endorsement notice
The text of amendment 1:2005 to the International Standard CISPR 16-2-1:2003 was approved by
CENELEC as an amendment to the European Standard without any modification.
__________
---------------------- Page: 3 ----------------------
COMMISSION
CISPR
ÉLECTROTECHNIQUE
16-2-1
INTERNATIONALE
2003
INTERNATIONAL
ELECTROTECHNICAL
AMENDEMENT 1
AMENDMENT 1
COMMISSION
2005-07
COMITÉ INTERNATIONAL SPÉCIAL DES PERTURBATIONS RADIOÉLECTRIQUES
INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE
Amendement 1
Spécifications des méthodes et des appareils de
mesure des perturbations radioélectriques et de
l'immunité aux perturbations radioélectriques –
Partie 2-1:
Méthodes de mesure des perturbations et de
l'immunité – Mesures des perturbations conduites
Amendment 1
Specification for radio disturbance and immunity
measuring apparatus and methods –
Part 2-1:
Methods of measurement of disturbances and
immunity – Conducted disturbance measurements
IEC 2005 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
F
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
---------------------- Page: 4 ----------------------
CISPR 16-2-1 Amend. 1 IEC:2005 – 3 –
FOREWORD
This amendment has been prepared by CISPR subcommittee A: Radio interference
measurements and statistical methods.
The text of this amendment is based on the following documents:
FDIS Report on voting
CISPR/A/582/FDIS CISPR/A/597/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the maintenance result date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
Page 3
Add the title of Annex D as follows:
Annex D (informative) Scan rates and measurement times for use with the average detector
Page 31
6.5.1 Minimum measurement times
Add, after the second paragraph, the following new paragraph:
Scan rates and measurement times for use with the average detector will be found in
Annex D.
Page 129
Add, after the existing Annex C, the following new Annex D:
---------------------- Page: 5 ----------------------
CISPR 16-2-1 Amend. 1 IEC:2005 – 5 –
Annex D
(informative)
Scan rates and measurement times for use with the average detector
D.1 General
This annex is intended to give guidance on the selection of scan rates and measurement
times when measuring impulsive disturbance with the average detector.
The average detector serves the following purposes:
a) to suppress impulsive noise and thus to enhance the measurement of CW components in
disturbance signals to be measured;
b) to suppress amplitude modulation (AM) in order to
...
Questions, Comments and Discussion