Plugs, socket-outlets and couplers for industrial purposes -- Part 4: Switched socket-outlets and connectors with or without interlock

This clause of Part 1 or Part 2 is applicable except as follows: Replacement of the first paragraph by the following text: This part of IEC 60309 applies to self-contained products that combine within a single enclosure, a socket-outlet or connector according to IEC 60309-1 or IEC 60309-2 and a switching device, with a rated operating voltage not exceeding 690 V d.c. or a.c. and 500 Hz , and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors or outdoors. These products may incorporate an interlock and/or protective devices.

Stecker, Steckdosen und Kupplungen für industrielle Anwendungen -- Teil 4: Abschaltbare Steckdosen und Kupplungen mit oder ohne Verriegelung

Prises de courant pour usages industriels -- Partie 4: Prises de courant et prises mobiles avec interrupteur, avec ou sans dispositif de verrouillage

Cette partie de la CEI 60309 s'applique aux ensembles indépendants qui combinent, dans une même enveloppe, un socle de prise de courant ou un connecteur suivant la CEI 60309-1 ou la CEI 60309-2, et un dispositif d'interruption, de tension nominale d'emploi ne dépassant pas 690 V en courant continu ou en courant alternatif, de fréquence ne dépassant pas 500 Hz en courant alternatif, et de courant nominal ne dépassant pas 250 A, destinés essentiellement aux usages industriels, à l'intérieur ou à l'extérieur des bâtiments.

Vtiči, vtičnice in spojke za industrijsko rabo - 4. del: Vtičnice in konektorji s stikalom in z zaklepom ali brez njega (IEC 60309-4:2006)

Ta točka 1. dela ali 2. dela se uporablja, razen kot sledi: Zamenjava prvega odstavka z naslednjim besedilom: Ta del standarda IEC 60309 se uporablja za avtonomne izdelke, ki so združeni v enem ohišju, vtičnici ali priključku v skladu s standardom IEC 60309-1 ali IEC 60309-2, ter stikalno napravo z nazivno obratovalno napetostjo, ki ne presega 690 V enosmerne ali izmenične napetosti in 500 Hz, ter nazivnim tokom, ki ne presega 250 A, in so namenjeni predvsem za industrijsko uporabo v notranjih prostorih ali na prostem. Ti izdelki lahko vsebujejo zaporne in/ali varovalne naprave.

General Information

Status
Published
Publication Date
28-Nov-2007
Technical Committee
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
26-Nov-2007
Due Date
31-Jan-2008
Completion Date
29-Nov-2007

Relations

Buy Standard

Standard
EN 60309-4:2008
English language
27 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60309-4:2008
01-februar-2008
9WLþLYWLþQLFHLQVSRMNH]DLQGXVWULMVNRUDERGHO9WLþQLFHLQNRQHNWRUMLV
VWLNDORPLQ]]DNOHSRPDOLEUH]QMHJD ,(&
Plugs, socket-outlets and couplers for industrial purposes - Part 4: Switched socket-
outlets and connectors with or without interlock (IEC 60309-4:2006)
Stecker, Steckdosen und Kupplungen für industrielle Anwendungen - Teil 4:
Abschaltbare Steckdosen und Kupplungen mit oder ohne Verriegelung (IEC 60309-
4:2006)
Prises de courant pour usages industriels - Partie 4: Prises de courant et prises mobiles
avec interrupteur, avec ou sans dispositif de verrouillage (IEC 60309-4:2006)
Ta slovenski standard je istoveten z: EN 60309-4:2007
ICS:
29.120.30
SIST EN 60309-4:2008 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD
EN 60309-4

NORME EUROPÉENNE
May 2007
EUROPÄISCHE NORM

ICS 29.120.30


English version


Plugs, socket-outlets and couplers for industrial purposes -
Part 4: Switched socket-outlets and connectors with or without interlock
(IEC 60309-4:2006, modified)


Prises de courant  Stecker, Steckdosen und Kupplungen
pour usages industriels - für industrielle Anwendungen -
Partie 4: Prises de courant Teil 4: Abschaltbare Steckdosen
et prises mobiles avec interrupteur, und Kupplungen
avec ou sans dispositif de verrouillage mit oder ohne Verriegelung
(CEI 60309-4:2006, modifiée) (IEC 60309-4:2006, modifiziert)




This European Standard was approved by CENELEC on 2007-03-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels


© 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60309-4:2007 E

---------------------- Page: 2 ----------------------

EN 60309-4:2007 - 2 -
Foreword
The text of document 23H/189/FDIS, future edition 1 of IEC 60309-4, prepared by SC 23H, Industrial plugs
and socket-outlets, of IEC TC 23, Electrical accessories, was submitted to the IEC-CENELEC parallel vote.
A draft amendment, containing some common modifications to the future IEC 60309-4, was prepared by
CENELEC BTWG 112-1, Improvement of EN 60309-1 and EN 60309-2, and was submitted to formal vote.
The combined texts were approved by CENELEC as EN 60309-4 on 2007-03-01.
This standard is to be read in conjunction with EN 60309-1:1999 + A1:2007 and EN 60309-2:1999 +
A1:2007.
Part 1 comprises clauses of a general character and the subsequent parts of the series deal with particular
types.
The clauses of the subsequent parts supplement or modify the corresponding clauses in Part 1. Where the
text of subsequent parts indicates an "addition" to or a "replacement" of the relevant requirement, test
specification or explanation of Part 1, these changes are made to the relevant text of Part 1, which then
becomes part of the standard. Where no change is necessary, the words "This clause of Part 1 is applicable"
are used.
Clauses, subclauses, figures, tables and notes which are additional to those in Part 1 are numbered starting
from 101.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2008-03-01
– latest date by which the national standards conflicting
(dow) 2010-03-01
with the EN have to be withdrawn
Annexes ZA and ZB have been added by CENELEC.
.__________

---------------------- Page: 3 ----------------------

- 3 - EN 60309-4:2007
Endorsement notice
The text of the International Standard IEC 60309-4:2006 was approved by CENELEC as a European
Standard with agreed common modifications as given below.
COMMON MODIFICATIONS
1 Scope
Add the following:
EN 60309-1 and EN 60309-2 contain common modifications regarding the use in Europe of AWG and MCM
cables, voltages and Series II products.
Those common modifications apply also within the scope of the present European Standard as indicated in
the relevant Part 1 or Part 2.
See Annex ZB for a list of additional references to AWG/MCM cables, non-European voltages and Series II
products which are excluded from this standard.

---------------------- Page: 4 ----------------------

EN 60309-4:2007 - 4 -
Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

Addition to Annex ZA of EN 60309-1 & EN 60309-2:

Publication Year Title EN/HD Year
1)
2)
IEC 60073 – Basic and safety principles for man-machine EN 60073
2002
interface, marking and identification - Coding
principles for indicators and actuators


IEC 60417 Data- Graphical symbols for use on equipment – –
base


IEC 60617 Data- Graphical symbols for diagrams – –
base


IEC 60947-1 2004 Low-voltage switchgear and controlgear - EN 60947-1 2004
Part 1: General rules + corr. November 2004


1) 2)
IEC 60947-4-1 – Low-voltage switchgear and controlgear - EN 60947-4-1 2001
Part 4-1: Contactors and motor-starters -
Electromechanical contactors and motor-
starters


IEC 60947-5-1 2003 Low-voltage switchgear and controlgear - EN 60947-5-1 2004
Part 5-1: Control circuit devices and switching + corr. July 2005
elements - Electromechanical control circuit
devices


1) 2)
IEC 61032 – Protection of persons and equipment by EN 61032 1998
enclosures - Probes for verification


1) 2)
IEC 61058-1 (mod) – Switches for appliances - EN 61058-1 2002
Part 1: General requirements




1)
Undated reference.
2)
Valid edition at date of issue.

---------------------- Page: 5 ----------------------

- 5 - EN 60309-4:2007

Annex ZB
(normative)

References to AWG/MCM cables, non-European voltages and/or Series II
which are excluded from this standard
The list below includes references to AWG/MCM cables, non-European voltages and/or Series II which are
excluded from this standard according to the specific rules given in Annex ZB of EN 60309-1:1999/A1:2007
or Annex ZC of EN 60309-2:1999/A1:2007 respectively.

EN 60309-4
12.1.2, Table 101
Clause 22, Table 8

---------------------- Page: 6 ----------------------

NORME CEI
INTERNATIONALE
IEC



60309-4
INTERNATIONAL


Première édition
STANDARD

First edition

2006-06


Prises de courant pour usages industriels –
Partie 4:
Prises de courant et prises mobiles
avec interrupteur, avec ou sans dispositif
de verrouillage

Plugs, socket-outlets and couplers
for industrial purposes –
Part 4:
Switched socket-outlets and connectors
with or without interlock

 IEC 2006 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
S
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

---------------------- Page: 7 ----------------------

60309-4  IEC:2006 – 3 –
CONTENTS
FOREWORD.5

1 Scope.9
2 Definitions .9
3 Normative references .13
4 General .13
5 Standard ratings .15
6 Classification.15
7 Marking .17
8 Dimensions .21
9 Protection against electric shock .21
10 Provision for earthing .23
11 Terminals .23
12 Interlocks, switches and their components.23
13 Resistance to ageing of rubber and thermoplastic material .33
14 General construction .33
15 Construction of socket-outlets .33
16 Construction of plugs and connectors .33
17 Construction of appliance inlets.33
18 Degrees of protection .33
19 Insulation resistance and dielectric strength .33
20 Breaking capacity .35
21 Normal operation.35
22 Temperature rise .35
23 Flexible cable and their connection.37
24 Mechanical strength .39
25 Screws, current-carrying parts and connections.41
26 Creepage distances, clearances and distances through sealing compound .41
27 Resistance to heat, fire and tracking.41
28 Corrosion and resistance to rusting .41
29 Conditional short-circuit current withstand test .41

---------------------- Page: 8 ----------------------

60309-4  IEC:2006 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________

PLUGS, SOCKET-OUTLETS AND COUPLERS
FOR INDUSTRIAL PURPOSES –

Part 4: Switched socket-outlets and connectors
with or without interlock


FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60309-4 has been prepared by subcommittee 23H: Plugs and
socket-outlets for industrial purposes, of IEC technical committee 23: Electrical accessories.
The text of this standard is based on the following documents:
FDIS Report on voting
23H/189/FDIS 23H/192/RVD

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 9 ----------------------

60309-4  IEC:2006 – 7 –
This standard is to be read in conjunction with IEC 60309-1 (1999) and IEC 60309-2 (1999).
Part 1 comprises clauses of a general character and the subsequent parts of the series deal
with particular types.
The clauses of the subsequent parts supplement or modify the corresponding clauses in Part
1. Where the text of subsequent parts indicates an "addition" to or a "replacement" of the
relevant requirement, test specification or explanation of Part 1, these changes are made to
the relevant text of Part 1, which then becomes part of the standard. Where no change is
necessary, the words "This clause of Part 1 is applicable" are used.
Clauses, subclauses, figures, tables and notes which are additional to those in Part 1 are
numbered starting from 101.
The IEC 60309 series, under the general title Plugs, socket-outlets and couplers for industrial
purposes comprises the following parts:
Part 1: General requirements
Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories
Part 4: Switched socket-outlets and connectors with or without interlock
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

---------------------- Page: 10 ----------------------

60309-4  IEC:2006 – 9 –
PLUGS, SOCKET-OUTLETS AND COUPLERS
FOR INDUSTRIAL PURPOSES –

Part 4: Switched socket-outlets and connectors
with or without interlock



1 Scope
This clause of Part 1 or Part 2 is applicable except as follows:
Replacement of the first paragraph by the following text:
This part of IEC 60309 applies to self-contained products that combine within a single
enclosure, a socket-outlet or connector according to IEC 60309-1 or IEC 60309-2 and a
switching device, with a rated operating voltage not exceeding 690 V d.c. or a.c. and 500 Hz ,
and a rated current not exceeding 250 A, primarily intended for industrial use, either indoors
or outdoors.
These products may incorporate an interlock and/or protective devices.
2 Definitions
This clause of Part 1 or Part 2 is applicable, except as follows:
Deletion of definitions 2.6 to 2.9.
Addition:
2.101
switched socket-outlet or connector
accessory containing in a single enclosure a switching device and a socket-outlet or
connector, intended to be used in combination. It can be either interlocked or non-interlocked
2.102
interlocked socket-outlet or connector
socket-outlet or connector associated with an interlock
2.103
switching device
device designated to make or break the current in one or more electric circuits
[IEV 441-14-01]
2.103.1
mechanical switching device
switching device designed to close and open one or more electric circuits by means of
separable contacts
[IEV 441-14-02]

---------------------- Page: 11 ----------------------

60309-4  IEC:2006 – 11 –
2.103.1.1
switch (mechanical)
mechanical switching device capable of making, carrying and breaking currents under normal
circuit conditions, which may include specified operating overload conditions and also
carrying, for a specified time, currents under specified abnormal circuit conditions such as
those of short-circuit
[IEV 441-14-10]
NOTE A switch may be capable of making, but not breaking short-circuit currents.
2.103.1.1.1
switch-disconnector
switch, which in the open position complies with the requirements specified for the isolating
function
[IEV 441-14-12, modified]
NOTE This definition differs from IEV 441-14-05 by referring to isolating function instead of the requirements
specified for a disconnector.
2.103.1.2
contactor
mechanical switching device having only one position of rest, operated otherwise than by
hand, capable of making, carrying and breaking currents under normal circuit conditions,
including operating overload conditions
[IEV 441-14-33]
2.103.2
associated switching device
separate switching device which can be replaced independently
2.103.3
integral switching device
switching device constructed as a part of a socket-outlet or connector covered by this
standard, where neither the switching device nor the socket-outlet or connector can be
replaced independently
2.104
isolation (isolating function)
function intended to cut off the supply from all or a discrete section of the installation, by
separating the installation or section from every source of electrical energy for reasons of
1
safety (see IEC 60947-1 and IEC 61140 )
2.105
utilization category
〈switching device〉 combination of specified requirements related to the conditions in which the
switching device fulfils its purpose, selected to represent a characteristic group of practical
applications
[IEV 441-17-19, modified]
NOTE The specified requirements may concern e.g. the values of making capacities (if applicable), breaking
capacities and other characteristics, the associated circuits under the relevant conditions of use and behaviour.
—————————
1
 IEC 61140, Protection against electric chock – Common aspects for installation and equipment

---------------------- Page: 12 ----------------------

60309-4  IEC:2006 – 13 –
2.106
interlock or interlocking device
device, either electrical or electronic or mechanical or a combination of these, which makes
the operation of a piece of product dependent upon the condition, position or operation of one
or more other pieces of product
2.107
control circuit device
electrical device intended for the controlling, signaling, interlocking, etc. of switchgear and
controlgear (see IEC 60947-1, 2.1.1)
2.108
pilot contact
auxiliary electric contact for use in a control or monitoring or interlock function
NOTE Pilot contact is not considered to be a pole.
2.109
latching device
part of the interlock mechanism provided to hold a plug or appliance-inlet in the socket-outlet
or connector
3 Normative references
This clause of Part 1 or Part 2 is applicable, except as follows:
Addition:
IEC 60073, Basic and safety principles for man-machine interface, marking and identification -
Coding principles for indicators and actuators
2
IEC 60417-DB:2002 , Graphical symbols for use on equipment
3
IEC 60617-DB:2001 , Graphical Symbols for diagrams
IEC 60947-1:2004, Low-voltage switchgear and controlgear – Part 1: General rules
IEC 60947-4-1, Low-voltage switchgear and controlgear – Part 4-1: Contactors and motor-
starters – Electromechanical contactors and motor-starters
IEC 60947-5-1:2003, Low-voltage switchgear and controlgear – Part 5-1: Control circuit
devices and switching elements – Electromechanical control circuit devices
IEC 61032, Protection of persons and equipment by enclosures – Probes for verification
IEC 61058-1, Switches for appliances – Part 1: General requirements
4 General
This clause of Part 1 or Part 2 is applicable except as follows:
—————————
2
“DB” refers to the IEC on-line database.
3
“DB” refers to the IEC on-line database.

---------------------- Page: 13 ----------------------

60309-4  IEC:2006 – 15 –
Addition:
4.101 Components incorporated or integrated in products (e.g. flexible cable, current cut-
outs, thermal cut-outs, safety transformers, switches, fuses, residual current devices,
lampholders and connecting devices) shall comply with the relevant standards as far as they
reasonably apply.
5 Standard ratings
This clause of Part 2 is applicable except as follows:
5.101 Replacement:
5.101 Standard IP ratings are
– IP44
– IP67
– IP66/IP67
For switched socket-outlet with or without interlock according to 6.1.101, the whole unit can
have a degree of protection different from IP44 or IP67 or IP66/IP67 but not lower than IP44
(see also 8.1).
6 Classification
This clause of Part 1 or Part 2 is applicable, except as follows:
6.1.1 Replacement:
6.1.1 According to purpose: socket-outlets, connectors
Deletion of 6.1.5.
Addition:
6.1.101 According to switching devices and interlock facilities:
– products with a switching device and without an interlock;
– products with a switching device and with an interlock.
6.1.102 According to the operation of the interlock/switching device
– manually;
– automatically (electrically and/or electronically);
– combination of the above.
NOTE Inserting the plug is not considered a manual operation of the interlock/switching device.
6.1.103 According to the mechanical switching device
– switch;
– switch-disconnector;

---------------------- Page: 14 ----------------------

60309-4  IEC:2006 – 17 –
– contactor;
– other devices with suitable switch rating.
6.1.104 According to suitability for isolation of the switching device
– suitable for isolation;
– not suitable for isolation.
6.1.105 According to whether the interlock system has a latching device
– with latching device (mechanical interlock);
– without latching device (electrical interlock).
6.1.106 According to the presence of a protective device
– with protective device;
– without protective device.
7 Marking
This clause of Part 1 or Part 2 is applicable, except as follows:
7.1 Addition:
– indication of the open and closed position of the switching device for products with
isolating function according to 6.1.104;
– indication of the type of switching device.
7.2 Addition:

Open position and/or
OFF
IEC 60417-5008

Closed position and/or
ON

IEC 60417-5007


Switch or


IEC 60617 – S00227
IEC 60947-3

Switch-disconnector

IEC 60617 – S00290

Contactor

IEC 60617 – S00284
Other devices According to IEC 60617

---------------------- Page: 15 ----------------------

60309-4  IEC:2006 – 19 –
7.3 Replacement:
7.3 The marking for rated current, the type reference, the nature of supply, if necessary, and
either the name or trademark of the manufacturer or the responsible vendor shall be on the
outside of the enclosure, or on the lid, if any, if the latter cannot be removed without the aid of
a tool.
These markings shall be easily discernible when the accessory is mounted and wired as in
normal use, if necessary after it has been removed from the enclosure. The marking, if any,
for the insulation voltage shall not be visible when the accessory is mounted and wired as in
normal use.
The marking for rated operating voltage, type reference, the degree of protection, and the
symbol indicating the position of the earthing contact or the means used for
interchangeability, if any, shall be on a place which is visible after installation of the
accessory, on the outside of enclosure or on the lid, if any, if the latter cannot be removed
without the aid of a tool.
With the exception of the type reference, these markings shall be easily discernible when the
accessory is mounted and wired as in normal use.
Compliance is checked by inspection.
7.4 This clause of Part 1 or Part 2 is not applicable.
7.5 Replacement:
7.5 Marking of the terminals for the supply cables
The neutral terminal, if any, shall be marked N.
The earth terminal, if any, shall be marked    or   .
The relationship between the terminals for the supply cable and load terminals/load contacts
shall be made clear, if necessary by means of a diagram or instruction.
Compliance is checked by inspection.
7.6 Replacement of the first sentence by the following text:
7.6 Marking on the outside of the enclosure shall be indelible and easily legible.
Addition:
7.101 The indication of the positions (open or closed) of the switching device shall be
unambiguous and clearly indicated.
The actuator of a mechanical switching device may be used to indicate the position of the
contacts.
For mechanical switching devices operated by means of two push-buttons, only the push-
button designated for the opening operation shall be red or marked with the symbol “O“.
The colours of other push-buttons, illuminated push-buttons and indicator lights shall be in
accordance with IEC 60073.

---------------------- Page: 16 ----------------------

60309-4  IEC:2006 – 21 –
7.102 The marking of the type of switching device shall be on a place which is visible after
installation of the products, on the outside of enclosure or on the lid, if any, if the latter cannot
be removed without the aid of a tool.
8 Dimensions
This clause of Part 2 is applicable except as follows:
8.1 Replacement of the first 2 paragraphs starting with “Accessories shall” and finishing with
“non-interchangeability” by the following:
Accessories shall comply with the relevant standard sheets as specified below:
– accessories having rated operating voltages exceeding 50 V:
– 16/20 A Sheets 2-VIII and 2-VIIIa;
– 16/20 A and 32/30 A Sheets 2-I, 2-II, 2-IX and 2-IXa;
– 63/60 A and 125/100 A, without pilot contact Sheets 2-III and 2-IV;
– 63/60 A and 125/100 A, with pilot contact Sheets 2-IIIa and 2-IVa;
– mec
...

Questions, Comments and Discussion