Road lighting - Part 5: Energy performance indicators

This part of the European Standard defines how to calculate the energy performance indicators for road
lighting installations using the calculated power density indicator (PDI) DP and the calculated annual
energy consumption indicator (AECI) DE. Power density indicator (DP) demonstrates the energy needed
for a road lighting installation, while it is fulfilling the relevant lighting requirements specified in
EN 13201-2. The annual energy consumption indicator (DE) determines the power consumption during
the year, even if the relevant lighting requirements change during the night or seasons.
These indicators may be used to compare the energy performance of different road lighting solutions
and technologies for the same road lighting project. The energy performance of road lighting systems
with different road geometries or different lighting requirements cannot be compared to each other
directly, as the energy performance is influenced by, amongst others, the geometry of the area to be lit,
as well as the lighting requirements. The power density indicator (DP) and annual energy consumption
indicator (DE) apply for all traffic areas covered by the series of lighting classes M, C and P as defined in
EN 13201-2.

Straßenbeleuchtung - Teil 5: Energieeffizienzindikatoren

Dieser Teil der vorliegenden Europäischen Norm legt fest, wie die Energieeffizienzindikatoren für Straßen-beleuchtungsanlagen unter Verwendung der berechneten Leistungsdichte (D) und des berechneten Energie-verbrauchsindikators (ECIy) zu berechnen sind. Die Leistungsdichte (D) veranschaulicht die für eine Straßen-beleuchtungsanlage benötigte Energie, indem sie die relevanten, in EN 13201-2 festgelegten Anforderungen an die Beleuchtung erfüllt. Der Energieverbrauchsindikator (ECIy) bestimmt den Energieverbrauch während des Jahres, auch wenn sich die entsprechenden Anforderungen an die Beleuchtung während der Nacht  oder Jahreszeiten ändern.
Diese Indikatoren können angewendet werden, um die Energieeffizienz verschiedener Lösungsmöglichkeiten und Technologien der Straßenbeleuchtung für das gleiche Straßenbeleuchtungsprojekt zu vergleichen. Die Gesamtenergieeffizienz von Straßenbeleuchtungsanlagen mit unterschiedlichen Straßengeometrien oder unterschiedlichen Anforderungen an die Beleuchtung kann nicht direkt miteinander verglichen werden, da die Energieeffizienz unter anderem von der Geometrie der zu beleuchtenden Fläche sowie von den Anforde-rungen an die Beleuchtung beeinflusst wird. Die Leistungsdichte (D) und die Energieverbrauchsindika-toren (ECIy) gelten für alle von der Reihe der Beleuchtungsklassen M, C und P abgedeckten Verkehrsflächen, wie in EN 13201-2 festgelegt.
Anhang B stellt den Anlagenwirkungsgrad und dessen Faktoren als Maß des Einflusses der verschiedenen Verluste und Parameter vor.

Éclairage public - Partie 5: Indicateurs de performance énergétique

Cette partie de la présente Norme européenne définit comment calculer les indicateurs de performances énergétiques pour les installations d'éclairage public en utilisant la puissance surfacique (D) calculé et l'indicateur de consommation d'énergie (ECIy) calculé. La puissance surfacique (D) démontre l'énergie nécessaire pour une installation d'éclairage public, tout en satisfaisant aux exigences d'éclairage pertinentes spécifiées dans l'EN 13201-2. L'indicateur de la consommation d'énergie (ECIy) détermine la consommation électrique pendant l'année, même si les exigences d'éclairage pertinentes changent au cours de la nuit ou des saisons.
Ces indicateurs peuvent être utilisés pour comparer les performances énergétiques de différentes solutions et technologies d'éclairage public pour le même projet d'éclairage public. Il n'est pas possible de comparer directement les performances énergétiques des systèmes d'éclairage public avec différentes géométries de routes ou différentes exigences d'éclairage les unes aux autres, car les performances énergétiques sont entre autres influencées par la géométrie de la zone à éclairer, ainsi que par les exigences d'éclairage. La puissance surfacique (D) et les indicateurs de consommation énergétique (ECIy) s'appliquent à toutes les zones de circulation couvertes par les séries de classes d'éclairage M, C et P définies dans l'EN 13201-2.
L'Annexe B présente l'efficacité de l'installation et ses facteurs en tant que mesure de l'influence de différentes pertes et différents paramètres.

Cestna razsvetljava - 5. del: Kazalniki energijske učinkovitosti

Ta del evropskega standarda določa, kako izračunati kazalnike energijske učinkovitosti za naprave za cestno razsvetljavo z uporabo izračunanega kazalnika gostote moči (PDI) DP in izračunanega kazalnika letne porabe energije (AECI) DE. Kazalnik gostote moči prikazuje energijo, ki je potrebna za napravo za cestno razsvetljavo v skladu z ustreznimi zahtevami glede razsvetljave iz standarda EN 13201-2. Kazalnik letne porabe energije določa porabo energije med letom, tudi če se tekom noči ali letnih časov ustrezne zahteve glede razsvetljave spremenijo.
Ti kazalniki se lahko uporabljajo za primerjavo energijske učinkovitosti različnih rešitev in tehnologij za cestno razsvetljavo v okviru istega projekta cestne razsvetljave. Neposredna primerjava energijske učinkovitosti sistemov za cestno razsvetljavo z različno geometrijo ceste oz. različnimi zahtevami glede razsvetljave ni mogoča, ker na energijsko učinkovitost med drugim vpliva tako geometrija območja, ki bo razsvetljeno, kot zahteve glede razsvetljave. Kazalnik gostote moči in kazalnik letne porabe energije se uporabljata za vsa prometna območja, ki so zajeta v razredih za razsvetljavo M, C in P, kot je določeno v standardu EN 13201-2.

General Information

Status
Published
Public Enquiry End Date
30-Oct-2013
Publication Date
19-May-2016
Current Stage
6100 - Translation of adopted SIST standards (Adopted Project)
Start Date
19-Nov-2020
Due Date
18-Nov-2021
Completion Date
16-Aug-2021

Buy Standard

Standard
EN 13201-5:2016
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard – translation
EN 13201-5:2016
Slovenian language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Straßenbeleuchtung - Teil 5: EnergieeffizienzindikatorenÉclairage public - Partie 5: Indicateurs de performance énergétiqueRoad lighting - Part 5: Energy performance indicators93.080.40Street lighting and related equipment27.015VSORãQREnergy efficiency. Energy conservation in generalICS:Ta slovenski standard je istoveten z:EN 13201-5:2015SIST EN 13201-5:2016en,fr,de01-junij-2016SIST EN 13201-5:2016SLOVENSKI
STANDARD



SIST EN 13201-5:2016



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 13201-5
December
t r s w ICS
{ uä r z rä v r English Version
Road lighting æ Part
wã Energy performance indicators Éclairage public æ Partie
wã Indicateurs de performance ßnergßtique
Straßenbeleuchtung æ Teil
wã Energieeffizienzindikatoren This European Standard was approved by CEN on
x June
t r s wä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey andUnited Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
9
t r s w CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s u t r sæ wã t r s w ESIST EN 13201-5:2016



EN 13201-5:2015 (E) 2 Contents Page European foreword . 4 Introduction . 5 1 Scope . 6 2 Normative references . 6 3 Terms, definitions, symbols and abbreviations . 6 3.1 Terms and definitions . 6 3.2 Symbols and abbreviations . 7 4 Power Density Indicator (PDI) . 9 4.1 Calculation of the power density indicator . 9 4.2 Average horizontal illuminance to be used for calculation of the power density indicator . 9 4.3 System power (P) to be used for calculation of the power density indicator . 10 4.4 Area (A) to be used for calculation of the power density indicator . 11 5 Annual Energy Consumption Indicator (AECI) . 11 Annex A (informative)
Examples of calculation and typical values of energy performance indicators . 13 A.1 Examples of operational profiles . 13 A.1.1 General . 13 A.1.2 Full power operation . 13 A.1.3 Multi-power operation . 14 A.1.4 Operation with vehicle and presence detectors . 14 A.2 Example of calculation . 15 A.3 Typical values of energy performance indicators . 16 A.3.1 General . 16 A.3.2 Two-lane road for motorized traffic (road profile A) . 17 A.3.3 Road with mixed motorized and pedestrian traffic without sidewalks (road profile B) . 18 A.3.4 Road and sidewalk on the side of lighting arrangement (road profile C) . 19 A.3.5 Road and sidewalk on the opposite side to the lighting arrangement (road profile D) . 20 A.3.6 Road and two sidewalks on both sides (road profile E) . 21 A.3.7 Road and two sidewalks on both sides separated from carriageway by grass strips (road profile F) . 22 A.3.8 Typical values of AECI for different operational profiles . 22 Annex B (informative)
Installation luminous efficacy . 24 B.1 General . 24 SIST EN 13201-5:2016



EN 13201-5:2015 (E) 3 B.2 Calculation of the correction factor . 24 B.3 Calculation of the utilance . 25 B.4 Calculation of the efficiency of luminaires . 25 Annex C (informative)
Lighting factor of an installation . 26 C.1 Installation lighting factor qinst . 26 C.2 Role of qinst in road lighting design aimed at energy saving . 26 C.3 Typical values of qinst . 26 Annex D (informative)
Presentation of energy performance indicators . 27 Bibliography . 28
SIST EN 13201-5:2016



EN 13201-5:2015 (E) 4 European foreword This document (EN 13201-5:2015) has been prepared by Technical Committee CEN/TC 169 “Light and lighting”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2016 and conflicting national standards shall be withdrawn at the latest by June 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. EN 13201, Road lighting is a series of documents that consists of the following parts: — Part 1: Guidelines on selection of lighting classes [Technical Report]; — Part 2: Performance requirements; — Part 3: Calculation of performance; — Part 4: Methods of measuring lighting performance; — Part 5: Energy performance indicators [present document]. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 13201-5:2016



EN 13201-5:2015 (E) 5 Introduction The purpose of this European Standard is to define energy performance indicators for road lighting installations. The standard introduces two metrics, the power density indicator (PDI) DP and the annual energy consumption indicator (AECI) DE that should always be used together. To quantify the potential savings obtainable from improved energy performance and reduced environmental impact, it is essential to calculate both the power density indicator (DP) and the annual energy consumption indicator (DE). In addition, the installation luminous efficacy (inst) can be used for comparing the energy performances of alternative road lighting installations. Careful choice of lighting class(es) during the design and specification phase will help to maximize energy savings by ensuring only the necessary levels of illumination provided at the correct times and for the minimum periods necessary. Additional guidance is given in the CEN/TR 13201-1 with regard to the visual needs of road users, e.g. under varying traffic volumes during certain times of night or under varying weather conditions. During the design phase of a road lighting installation care should be taken to ensure that the design criteria specified in EN 13201-2 are achieved but that excess overlighting is reduced to the minimum technically obtainable. Overlighting can be minimized by the careful selection of the luminaire and light source but the specified lighting class, the designed lighting point spacing and uniformity ratios are all determining factors of the luminous flux emitted by the light source and thus the power of the light source required. However, this precise luminous flux may not, in reality, exist. Where the luminous flux of the light source is greater than that required the designer can by means of continuously variable control gear, compensate for this effect by reducing the luminous flux of the light source to the required level resulting in lower energy consumption. The same principles and control gear can be used to compensate for changes in luminous flux emitted throughout the lifetime of the light sources. The energy levels calculated using this standard should not be used as a direct input for the calculation of the load on the electrical distribution system. Such calculations are normally based on the energy requirement derived directly from the lighting and electrical design. Examples of operational profiles and examples of calculation of the energy performance indicators are provided in Annex A. Typical values of energy performance indicators are provided to illustrate the energy performance of recent technological level of luminaires and installations. Annex B introduces the installation luminous efficacy and its factors as a measure of the influence of various light losses and other parameters. Lighting factor of an installation, as introduced in Annex C, can be additionally used to characterize the energy performance of road lighting installations independently on the lighting components used. Other factors and parameters having influence to the energy performance, such as the maintenance factor (see CIE 154), can be recognized but are not dealt with in this standard. Recommendations on presentation of the energy performance indicators are provided in Annex D. SIST EN 13201-5:2016



EN 13201-5:2015 (E) 6 1 Scope This part of the European Standard defines how to calculate the energy performance indicators for road lighting installations using the calculated power density indicator (PDI) DP and the calculated annual energy consumption indicator (AECI) DE. Power density indicator (DP) demonstrates the energy needed for a road lighting installation, while it is fulfilling the relevant lighting requirements specified in EN 13201-2. The annual energy consumption indicator (DE) determines the power consumption during the year, even if the relevant lighting requirements change during the night or seasons. These indicators may be used to compare the energy performance of different road lighting solutions and technologies for the same road lighting project. The energy performance of road lighting systems with different road geometries or different lighting requirements cannot be compared to each other directly, as the energy performance is influenced by, amongst others, the geometry of the area to be lit, as well as the lighting requirements. The power density indicator (DP) and annual energy consumption indicator (DE) apply for all traffic areas covered by the series of lighting classes M, C and P as defined in EN 13201-2. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12665:2011, Light and lighting — Basic terms and criteria for specifying lighting requirements EN 13201-2, Road lighting — Part 2: Performance requirements EN 13201-3:2015, Road lighting — Part 3: Calculation of performance 3 Terms, definitions, symbols and abbreviations 3.1 Terms and definitions For the purposes of this document, the terms and definitions given in EN 12665:2011 and the following apply. 3.1.1 system power (of a lighting installation in a given state of operation) P total power of the road lighting installation needed to fulfil the required lighting classes as specified in EN 13201-2 in all the relevant sub-areas, and to operate and control the lighting installation (unit: W) 3.1.2 power density indicator PDI (of a lighting installation in a given state of operation) DP value of the system power divided by the value of the product of the surface area to be lit and the calculated maintained average illuminance value on this area according to EN 13201-3 (unit: W.lx-1.m-2) SIST EN 13201-5:2016



EN 13201-5:2015 (E) 7 3.1.3 annual energy consumption indicator AECI (of a lighting installation in a specific year) DE total electrical energy consumed by a lighting installation day and night throughout a specific year in proportion to the total area to be illuminated by the lighting installation (unit: Wh.m-2) 3.1.4 installation luminous efficacy inst minimum luminous flux needed to provide the minimum lighting level for the specified area divided by the total average power consumption of the lighting installation (unit: lm.W-1) 3.1.5 constant light output CLO (of a road lighting installation) regulation of the road lighting installation aiming at providing a constant light output from the light sources Note 1 to entry: This functionality aims to compensate for the light loss caused by ageing of the light sources. 3.1.6 installation lighting factor qinst dimensionless factor accounting for the relation of the calculated average maintained luminance of road surface over the calculated average maintained horizontal illuminance on this surface and the average luminance coefficient of the r-table adopted in luminance calculation 3.2 Symbols and abbreviations Table 1 — Symbols and abbreviations Symbol or abbreviation Name or description Unit A Area to be lit m2 AFL Area of the left sidewalk m2 AFR Area of the right sidewalk m2 AR Area of the carriageway m2 AECI Annual Energy Consumption Indicator
CL Correction factor for luminance or hemispherical illuminance based lighting designs - cop Lighting operation coefficient - CLO Constant Light Output
DE Annual energy consumption indicator (AECI) Wh.m-2 DP Power density indicator (PDI) W.lx-1.m-2 E Average maintained horizontal illuminance lx EFL Calculated maintained illuminance on the left sidewalk lx EFR Calculated maintained illuminance on the right sidewalk lx SIST EN 13201-5:2016



EN 13201-5:2015 (E) 8 Symbol or abbreviation Name or description Unit Ehs Hemispherical illuminance lx minE Minimum required average illuminance lx ER Calculated maintained illuminance on the carriageway lx EIR Edge Illuminance Ratio
fM Overall maintenance factor (MF) of the lighting installation - kred Reduction coefficient for the reduced level illumination - L Average maintained luminance cd.m-2 minL Minimum required average luminance cd.m-2 LOR Light Output Ratio
m Number of operation time periods for different levels of operational power P - MF Maintenance Factor
n Number of sub-areas to be lit - nlp Number of light points associated with the lighting installation or the representative section - P System power of all the luminaires designed to lit the relevant area W Pad Total active power of any devices not considered in the operational power P but necessary for operation of the road lighting installation W PF System power of the luminaire designed for illumination of the sidewalk W Pls Power of lamp(s) inside the luminaire W PR System power of the luminaire designed for illumination of the carriegeway W PDI Power Density Indicator
RLO Optical efficiency of luminaires (LOR) used in the lighting installation - qinst Lighting factor of an installation - Qo Average luminance coefficient sr-1 t Duration of the operation time for a particular system power P over a year h tfull Annual operation time of the full level illumination h tred Annual operation time of the reduced level illumination h U Utilance of the lighting installation - A Luminous flux reaching the area to be illuminated lm ls Luminous flux emitted from the light source(s) in a luminaire lm inst Installation luminous efficacy lm.W-1 ls Luminous efficacy of the light sources used in the installation lm.W-1 nlu Number of luminaires considered in the calculation - P Power efficiency of luminaires used in the lighting installation - SIST EN 13201-5:2016



EN 13201-5:2015 (E) 9 4 Power Density Indicator (PDI) 4.1 Calculation of the power density indicator Power density indicator for an area divided into sub-areas for a given state of operation shall be calculated with the following formula: Pii==⋅∑PDEA1()ni (1) where DP is the power density indicator, W·lx-1·m-2; P is the system power of the lighting installation used to light the relevant areas (see 4.3), in W; iE is the maintained average horizontal illuminance of the sub-area “i” determined in accordance with 4.2, in lx; Ai is the size of the sub-area “i” lit by the lighting installation, in m2; n
is the number of sub-areas to be lit. If the required lighting class changes during the night and/or through the seasons (for example reductions in lighting class due to decreased traffic density, changes in the visual environment or other relevant parameters), the power density (DP) should be calculated separately for each of the lighting classes. Alternatively, where multiple lighting classes are used during the night or year the power density (DP) may be calculated as an average over this period. The calculation shall clearly indicate the assumptions used for calculation of the power density (DP) and how this value was evaluated. Values of the power density indicator (DP) shall be always presented and used together with the annual energy consumption indicator (DE) for assessment of the energy performance of a particular lighting system. 4.2 Average horizontal illuminance to be used for calculation of the power density indicator For illuminance based lighting classes (C and P) the maintained average horizontal illuminance (E) to be used for the power density (DP) calculation shall be calculated according to EN 13201-3. For luminance based lighting classes (M) the maintained average horizontal illuminance (E) to be used for the power density (DP) calculation shall be the average of illuminance values calculated on the same grid of points which are used for the calculation of luminance in accordance with EN 13201-3. For hemispherical illuminance based lighting classes (HS) the maintained average horizontal illuminance (E) to be used for the power density (DP) calculation shall be the average of illuminance values calculated on the same grid of points which are used for the calculation of hemispherical illuminance in accordance with EN 13201-3. Some lighting installations may be over lit in terms of significantly higher lighting levels than those required or specified. When such over lighting occurs, it should be determined if this is as a result of poor design or as an unavoidable consequence of other requirements. From an energy efficiency and environmental perspective corrective action should be taken to minimize any over lighting. SIST EN 13201-5:2016



EN 13201-5:2015 (E) 10 From an energy efficiency and environmental perspective the calculated lighting level for any lighting installation should not exceed the required lighting level of the next higher lighting class (or not exceed the required lighting level by 50 % in case of the highest class) without considering other design solutions. 4.3 System power (P) to be used for calculation of the power density indicator The system power (P) shall be calculated from the sum of the operational power of the light sources, control gear(s) and any other electrical device(s) (lighting point control unit(s), switch(es), photoelectric cell(s), etc.) which are directly associated with the lighting of the area to be lit and installed in order to operate or regulate the installation. The system power (P) should be calculated for the complete lighting installation or the representative section used during the lighting design according to the following formula: pkad1lnk==+∑PPP (2) where P
is the total system power of the lighting installation or its representative section, in W; Pk
is the operational power of the ‘kth’ lighting point (light source, gear, any other device like lighting point control unit, switch or photoelectric cell and component, which are associated with the lighting point and necessary for its operation), in W; Pad is the total operational power of any devices not considered in Pk but necessary for the operation of the road installation such as a remote switch or photoelectric cell, centralized luminous flux controller or centralized management system, etc. in W. Where the system power is calculated for a representative area the total operational power Pad should be proportioned according to the number of luminaires used to illuminate the area over the total number of luminaires supplied from the devices represented by Pad. nlp is the number of lighting points associated with the lighting installation or the representative section whichever is used in the calculation. If light sources (and other electrical devices) are operated on constant power, this power shall be used when the system power (P) is calculated. If the lighting class changes during the night and/or seasons (for example reduction in lighting class during the night due to decreased traffic density, changes in the visual environment or other relevant parameters), the system power (P) corresponding to the required lighting class in that period should be calculated. NOTE PDI can be a single number for full-time constant power operation and for 100 % dimming level in regulated systems, or it can represent different numbers for each considered state of operation. Annex A gives examples of calculation and Annex D gives an example of the presentation of results. Where the luminous flux output of the light source is varied to compensate for changes in luminous flux output throughout lifetime of the light sources (for example the light sources use constant light output (CLO) drivers), the average system power associated with these variations should be used for the calculation of power density (DP). If the calculation for the main lighting class is based on a single calculation for a section of the road, i. e. for a typical arrangement and spacing, then the system power (P) calculation shall include the sum of the power of all luminaires and the electrical device(s) related to luminaires, lighting points and segments which are inside and on the edges of the calculation area relevant to this typical arrangement, SIST EN 13201-5:2016



EN 13201-5:2015 (E) 11 in accordance with EN 13201-3. Annex A shows some typical examples. The number of luminaires and size of the area shall be relevant to each other. If the calculation is performed for an irregular shaped area, the system power (P) calculation shall include the sum of the power of each luminaire and the electrical device(s) related to luminaires, lighting points and segments, which are needed to light the area. The system power (P) should not include any power associated with devices which are not used to fulfil the lighting function, even if they are connected to the same network. Typical examples are illuminated advertisement and festive lighting. 4.4 Area (A) to be used for calculation of the power density indicator The area used for calculation of the power density indicator (DP) shall be identical to the area used in lighting design for lighting calculation of parameters according to EN 13201-2 and described in EN 13201-3. If the carriageway of a road is not surrounded by other areas (for example another carriageway, footpath, cycle path or parking areas, etc., which have their own individual specified lighting requirements) and Edge Illuminance Ratio (EIR) is calculated in accordance with EN 13201-2, the surrounding areas used for calculating EIR are not included in the calculation of power density indicator. 5 Annual Energy Consumption Indicator (AECI) The annual electricity consumption of a road lighting installation depends on: — the period of time for which lighting is provided, — the lighting class specified by the relevant lighting standard for each lighting period, — the efficiency of the lighting installation, when providing the necessary lighting for each period, — the way the lighting management system follows the change in visual needs of road users, — the parasitic energy consumption of lighting devices during the period when the lighting is not needed. For comparison and monitoring of the energy performance of a lighting installation, the energy consumption indicator shall take into account the annual accumulated energy use of road lighting illuminating the street or public area, however actual lighting needs may vary during the year because of the following reasons: — seasonal variations of daylight / night time hours: this depends on the geographical location of the area, — changing weather conditions which influence perceived visual performance (i.e. dry or wet road surface), — changing traffic density on the street or public area during the night (i.e. different temporal pattern of usage such as increased usage at “rush hour”) or following the fluctuation in social activity (i.e. school terms, national holiday periods), — changing functionality of the street or public area (i.e. roads are closed for a certain period or turned to pedestrian areas in festive seasons). SIST EN 13201-5:2016



EN 13201-5:2015 (E) 12 Annual energy consumption indicator (AECI) shall be calculated with the following formula: jjE=⋅=∑1()mjPtDA (3) where DE is the annual energy consumption indicator for a road lighting installation, in Wh.m-2; Pj is the operational power associated with the jth period of operation, in W; tj is the duration of jth period of operation profile when the power Pj is consumed, over a year, in h; A is the size of the area lit by the same lighting arrangement, in m2; m is the number of periods with different operational power Pj. m shall also consider the period over which the quiescent power is consumed. This period would generally be the time when the lighting is not operational, i.e. daylight hours and any night time period when the lighting is not lit. If the light output of a light source is intended to be constant, but the power consumption of this light source (or other electrical devices) v
...

SLOVENSKI SIST EN 13201-5


STANDARD   junij 2016













Cestna razsvetljava – 5. del: Kazalniki energijske učinkovitosti


Road lighting – Part 5: Energy performance indicators


Straßenbeleuchtung – Teil 5: Energieeffizienzindikatoren


Éclairage public – Partie 5: Indicateurs de performance énergétique





















Referenčna oznaka
ICS 27.015; 93.080.40 SIST EN 13201-5:2016 (sl)

Nadaljevanje na strani II in od 1 do 27

© 2021-09: Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 13201-5 : 2016

NACIONALNI UVOD

Standard SIST EN 13201-5 (sl), Cestna razsvetljava – 5. del: Kazalniki energijske učinkovitosti, 2016,
ima status slovenskega standarda in je enakovreden evropskemu standardu EN 13201-5 (en), Road
lighting – Part 5: Energy performance indicators, 2015.

NACIONALNI PREDGOVOR
Evropski standard EN 13201-5:2015 je pripravil tehnični odbor Evropskega komiteja za standardizacijo
CEN/TC 169 Svetloba in razsvetljava v gradbeništvu, katerega tajništvo je v pristojnosti DIN.

Slovenski standard SIST EN 13201-5:2016 je prevod evropskega standarda EN 13201-5:2015. V
primeru spora glede besedila slovenskega prevoda v tem standardu je odločilen izvirnik standarda v
angleškem jeziku. Slovensko izdajo standarda je pripravil tehnični odbor SIST/TC STV Steklo, svetloba
in razsvetljava v gradbeništvu.
Odločitev za privzem tega standarda je SIST/TC STV sprejel 26. maja 2016.
ZVEZA Z NACIONALNIMI STANDARDI
S privzemom tega evropskega standarda veljajo za omejeni namen referenčnih standardov vsi
standardi, navedeni v izvirniku, razen tistih, ki so že sprejeti v nacionalno standardizacijo:
SIST EN 12665:2011 Svetloba in razsvetljava – Osnovni izrazi in merila za specifikacijo
  zahtev za razsvetljavo (razveljavljen, velja SIST EN 12665:2018)

SIST EN 13201-2 Cestna razsvetljava – 2. del: Zahtevane lastnosti

SIST EN 13201-3:2016  Cestna razsvetljava – 3. del: Izračun lastnosti

OSNOVA ZA IZDAJO STANDARDA

– privzem standarda EN 13201-5:2015

OPOMBE
– Povsod, kjer se v besedilu standarda uporablja izraz “evropski standard”, v SIST EN 13201-5
to pomeni “slovenski standard”.
– Nacionalni uvod in nacionalni predgovor nista sestavni del standarda.
– Ta nacionalni dokument je enakovreden EN 13201-5:2015 in je objavljen z dovoljenjem
  Upravni center CEN-CENELEC
  Avenue Marnix 17
  B-1000 Bruselj
  Belgija

This national document is identical with EN 13201-5:2015 and is published with the permission of

  CEN-CENELEC Management centre
  Avenue Marnix 17
  B-1000 Brussels
  Belgium


II

---------------------- Page: 2 ----------------------
EVROPSKI STANDARD EN 13201-5
EUROPEAN STANDARD

NORME EUROPÉENNE
december 2015
EUROPÄISCHE NORM

ICS 93.080.40






Slovenska izdaja

Cestna razsvetljava – 5. del: Kazalniki energijske učinkovitosti

Road lighting – Part 5: Energy Éclairage public – Partie 5: Straßenbeleuchtung – Teil 5:
performance indicators Indicateurs de performance Energieeffizienzindikatoren
énergétique





Ta evropski standard je CEN sprejel 6. junija 2015.

Člani CEN morajo izpolnjevati notranje predpise CEN/CENELEC, ki določajo pogoje, pod katerimi
dobi ta evropski standard status nacionalnega standarda brez kakršnihkoli sprememb. Najnovejši
seznami teh nacionalnih standardov in njihovi bibliografski podatki se na zahtevo lahko dobijo pri
Upravnem centru CEN-CENELEC ali kateremkoli članu CEN.

Ta evropski standard obstaja v treh uradnih izdajah (angleški, francoski, nemški). Izdaje v drugih
jezikih, ki jih člani CEN na lastno odgovornost prevedejo in izdajo ter prijavijo pri Upravnem centru
CEN-CENELEC, veljajo kot uradne izdaje.

Člani CEN so nacionalni organi za standarde Avstrije, Belgije, Bolgarije, Cipra, Češke republike,
Danske, Estonije, Finske, Francije, Grčije, Hrvaške, Islandije, Irske, Italije, Latvije, Litve,
Luksemburga, Madžarske, Malte, Nemčije, Nizozemske, Norveške, Poljske, Portugalske, Romunije,
Nekdanje jugoslovanske republike Makedonije, Slovaške, Slovenije, Španije, Švedske, Švice,
Turčije in Združenega kraljestva.













CEN
Evropski komite za standardizacijo
European committee for standardization
Comité européen de normalisation
Europäisches komitee für normung

Upravni center CEN-CENELEC: Avenue Marnix 17, B-1000 Bruselj



© 2015 CEN Lastnice avtorskih pravic so vse države članice Ref. oznaka EN 13201-5:2015 E
CEN.

---------------------- Page: 3 ----------------------
SIST EN 13201-5 : 2016

VSEBINA Stran

Evropski predgovor . 4
Uvod . 5
1 Področje uporabe . 6
2 Zveze s standardi . 6
3 Izrazi, definicije, simboli in okrajšave . 6
3.1 Izrazi in definicije . 6
3.2 Simboli in okrajšave . 7
4 Kazalnik gostote moči (PDI) . 9
4.1 Izračun kazalnika gostote moči . 9
4.2 Povprečna horizontalna osvetljenost za izračun kazalnika gostote moči . 9
4.3 Sistemska moč (P) za izračun kazalnika gostote moči . 10
4.4 Površina (A) za izračun kazalnika gostote moči . 11
5 Kazalnik letne porabe energije (AECI) . 11
Dodatek A (informativni): Primeri izračunov in tipične vrednosti kazalnikov
  energijske učinkovitosti . 13
A.1 Primeri diagramov delovanja . 13
A.1.1 Splošno . 13
A.1.2 Obratovanje s polno močjo . 13
A.1.3 Obratovanje z več stopnjami moči . 13
A.1.4 Obratovanje z detektorji vozil in senzorji prisotnosti . 14
A.2 Primer izračuna . 14
A.3 Tipične vrednosti kazalnikov energijske učinkovitosti . 16
A.3.1 Splošno . 16
A.3.2 Dvopasovna cesta za motorni promet (cestni profil A) . 17
A.3.3 Cesta za mešani motorni promet in pešce brez pločnikov (cestni profil B) . 18
A.3.4 Cesta s pločnikom na strani, kjer je razsvetljava (cestni profil C) . 19
A.3.5 Cesta s pločnikom na nasprotni strani razsvetljave (cestni profil D) . 20
A.3.6 Cesta s pločnikoma na obeh straneh (cestni profil E) . 20
A.3.7 Cesta s pločnikoma na obeh straneh, ločenima od vozišča z zelenim pasom
     (cestni profil F) . 21
A.3.8 Tipične vrednosti AECI za različne diagrame delovanja . 22
Dodatek B (informativni): Svetlobni izkoristek inštalacije . 23
B.1 Splošno . 23
B.2 Izračun korekcijskega faktorja . 23
B.3 Izračun prostorskega izkoristka . 24
B.4 Izračun izkoristka svetilk . 24
Dodatek C (informativni): Svetlobni faktor inštalacije . 25
C.1 Svetlobni faktor inštalacije q . 25
inst
C.2 Vloga q pri projektiranju energijsko varčne cestne razsvetljave . 25
inst
2

---------------------- Page: 4 ----------------------
SIST EN 13201-5 : 2016

C.3 Tipične vrednosti q . 25
inst
Dodatek D (informativni): Podajanje kazalnikov energijske učinkovitosti . 26
Literatura. 27

3

---------------------- Page: 5 ----------------------
SIST EN 13201-5 : 2016

Evropski predgovor

Ta dokument (EN 13201-5:2015) je pripravil tehnični odbor CEN/TC 169 Svetloba in razsvetljava,
katerega tajništvo vodi DIN.

Ta evropski standard mora dobiti status nacionalnega standarda bodisi z objavo istovetnega besedila
ali z razglasitvijo najpozneje do junija 2016. Nacionalne standarde, ki so v nasprotju s tem standardom,
je treba razveljaviti najpozneje do junija 2016.

Opozoriti je treba na možnost, da so lahko nekateri elementi tega dokumenta predmet patentnih pravic.
CEN [in/ali CENELEC] ni odgovoren za identifikacijo nekaterih ali vseh takih patentnih pravic.

EN 13201, Cestna razsvetljava, je skupina dokumentov, sestavljena iz naslednjih delov:

‒ 1. del: Smernice za izbiro svetlobnotehničnih razredov [tehnično poročilo]

‒ 2. del: Zahtevane lastnosti

‒ 3. del: Izračun lastnosti

‒ 4. del: Metode za merjenje lastnosti razsvetljave

‒ 5. del: Kazalniki energijske učinkovitosti [ta dokument]

V skladu z notranjimi predpisi CEN/CENELEC morajo ta evropski standard obvezno uvesti nacionalne
organizacije za standarde naslednjih držav: Avstrije, Belgije, Bolgarije, Cipra, Češke republike, Danske,
Estonije, Finske, Francije, Hrvaške, Grčije, Islandije, Irske, Italije, Latvije, Litve, Luksemburga,
Madžarske, Malte, Nemčije, Nizozemske, Norveške, Poljske, Portugalske, Romunije, Nekdanje
jugoslovanske republike Makedonije, Slovaške, Slovenije, Španije, Švedske, Švice, Turčije in
Združenega kraljestva.

4

---------------------- Page: 6 ----------------------
SIST EN 13201-5 : 2016

Uvod

Namen tega evropskega standarda je določiti kazalnike energijske učinkovitosti inštalacij cestne
razsvetljave. Standard uvaja dve metriki, kazalnik gostote moči (PDI) D in kazalnik letne porabe energije
P
(AECI) D , ki naj se vedno uporabljata skupaj.
E

Za količinsko opredelitev potencialnih prihrankov, ki jih je mogoče doseči z izboljšano energijsko
učinkovitostjo in zmanjšanim vplivom na okolje, je bistveno izračunati oba kazalnika: kazalnik gostote
moči (D ) in kazalnik letne porabe energije (D ). Poleg tega se lahko za primerjavo energijske
P E
učinkovitosti alternativnih inštalacij cestne razsvetljave uporablja tudi svetlobni izkoristek inštalacije
(η ).
inst

Skrbna izbira svetlobnotehničnega(-ih) razreda(-ov) med snovanjem in določanjem lastnosti bo
pripomogla k doseganju največjih prihrankov energije z zagotavljanjem samo potrebnih ravni osvetlitve
ob pravem času in s potrebnim trajanjem. Dodatna navodila so podana v CEN/TR 13201-1 glede na
vidne potrebe uporabnikov ceste, npr. pri različni gostoti prometa v določenih obdobjih noči ali v različnih
vremenskih razmerah.

Med projektiranjem cestne razsvetljave je treba paziti, da so izpolnjena vsa merila za projektiranje,
določena v EN 13201-2, in da se čezmerna osvetlitev zmanjša na najnižjo tehnično dosegljivo raven.
Čezmerna osvetlitev se lahko zmanjša s skrbno izbiro svetilke in svetlobnega vira, vendar pa določen
svetlobnotehnični razred, projektirana razdalja med svetlobnimi mesti in enakomernostjo odločilno
vplivajo na potreben svetlobni tok vira in tako na njegovo potrebno električno moč. Vendar pa tako
natančno določen svetlobni tok ni nujno tehnično možen. Če je svetlobni tok izbranega svetlobnega vira
večji, kot je zahtevan, ga lahko projektant s pomočjo zvezno spremenljive krmilne naprave ustrezno
zmanjša na potrebno raven in tako zmanjša tudi porabo električne energije. Ista načela in ista krmilna
naprava se lahko uporabijo tudi za kompenzacijo zmanjšanja svetlobnega toka v življenjski dobi
svetlobnih virov.

Izračunana količina porabljene energije po tem standardu naj se ne uporablja neposredno za izračun
obremenitve električnega razdelilnega omrežja. Tovrstni izračuni normalno temeljijo na potrebni energiji,
ki se določi neposredno iz svetlobne in električne zasnove.

Primeri različnih načinov delovanja in primeri izračunov kazalnikov energijske učinkovitosti so podani v
dodatku A. Za ponazoritev energijske učinkovitosti sodobnih tehničnih rešitev svetilk in svetlobnih
inštalacij so podane tudi tipične vrednosti kazalnikov energijske učinkovitosti.

V dodatku B je predstavljen svetlobni izkoristek inštalacije in njegovi faktorji kot merilo vpliva različnih
svetlobnih izgub in drugih parametrov.

Svetlobni faktor razsvetljave, kot je predstavljen v dodatku C, se lahko dodatno uporablja za
označevanje energijske učinkovitosti inštalacij cestne razsvetljave, neodvisno od uporabljenih
svetlobnih komponent. Drugi faktorji in parametri, ki tudi vplivajo na energijsko učinkovitost razsvetljave,
kot na primer faktor vzdrževanja (glej CIE 154), se tudi lahko uporabijo, vendar jih ta standard ne
obravnava.

Priporočila glede predstavitve kazalnikov energijske učinkovitosti so podana v dodatku D.


5

---------------------- Page: 7 ----------------------
SIST EN 13201-5 : 2016

1 Področje uporabe

Ta del evropskega standarda določa, kako izračunati kazalnike energijske učinkovitosti inštalacij cestne
razsvetljave z uporabo izračunanega kazalnika gostote moči (PDI) D in izračunanega kazalnika letne
P
porabe energije (AECI) D . Kazalnik gostote moči (D ) prikazuje energijo, potrebno za inštalacijo cestne
E P
razsvetljave, ko ta izpolnjuje ustrezne svetlobnotehnične zahteve, določene v EN 13201-2. Kazalnik
letne porabe energije (D ) določa porabo električne energije med letom, tudi če se ustrezne
E
svetlobnotehnične zahteve spreminjajo ponoči ali v sezoni.

Ta kazalnika se lahko uporabljata za primerjavo energijske učinkovitosti različnih rešitev in tehnologij
cestne razsvetljave v istem projektu. Energijske učinkovitosti sistemov cestne razsvetljave pri različnih
geometrijah cest ali različnih svetlobnotehničnih zahtevah ni mogoče neposredno medsebojno
primerjati, ker na energijsko učinkovitost med drugim vplivajo geometrija področja, ki ga je treba osvetliti,
in tudi svetlobnotehnične zahteve za to področje. Kazalnik gostote moči (D ) in kazalnik letne porabe
P
energije (D ) se lahko uporabita za vse prometne površine, ki jih zajema skupina svetlobnotehničnih
E
razredov M, C in P, kot so določeni v EN 13201-2.

2 Zveze s standardi

Ta dokument se v celoti ali delno normativno sklicuje na spodaj navedene dokumente, ki so nepogrešljivi
za njegovo uporabo. Za datirana sklicevanja velja samo navedena izdaja. Za nedatirana sklicevanja se
uporablja zadnja izdaja referenčnega dokumenta (vključno z vsemi dopolnili).

EN 12665:2011 Svetloba in razsvetljava – Osnovni izrazi in merila za specifikacijo
svetlobnotehničnih zahtev

EN 13201-2 Cestna razsvetljava – 2. del: Zahtevane lastnosti

EN 13201-3:2015 Cestna razsvetljava – 3. del: Izračun lastnosti

3 Izrazi, definicije, simboli in okrajšave

3.1 Izrazi in definicije

V tem dokumentu se uporabljajo izrazi in definicije iz EN 12665:2011 ter naslednji:

3.1.1
sistemska moč (inštalacije razsvetljave v danem obratovalnem stanju)
P
skupna moč inštalacije cestne razsvetljave, ki je potrebna za izpolnjevanje zahtev svetlobnotehničnih
razredov, kot so določeni v EN 13201-2, v vseh ustreznih podpodročjih ter za delovanje in krmiljenje
inštalacije razsvetljave (enota: W)

3.1.2
kazalnik gostote moči PDI (inštalacije razsvetljave v danem obratovalnem stanju)
D
P
vrednost sistemske moči, deljena z vrednostjo zmnožka površine, ki jo je treba osvetliti, in vrednosti
–1 –2
izračunane vzdrževane osvetljenosti na tej površini v skladu z EN 13201-3 (enota: W•lx •m )

3.1.3
kazalnik letne porabe energije AECI (inštalacije razsvetljave v določenem letu)
D
E
skupna električna energija, ki jo inštalacija razsvetljave porabi podnevi in ponoči v določenem letu,
–2
deljena s skupno površino, ki jo inštalacija razsvetljave osvetljuje (enota: Wh•m )




6

---------------------- Page: 8 ----------------------
SIST EN 13201-5 : 2016

3.1.4
svetlobni izkoristek inštalacije
η
inst
najmanjši svetlobni tok, ki je potreben za najmanjši svetlobni nivo za obravnavano področje, deljen s
–1
skupno povprečno porabo električne energije inštalacije razsvetljave (enota: lm•W )

3.1.5
konstantni svetlobni tok CLO (inštalacije cestne razsvetljave)
regulacija inštalacije cestne razsvetljave, katere namen je zagotoviti konstanten svetlobni tok svetlobnih
virov

Opomba 1: Namen tega krmiljenja je kompenzirati upadanje svetlobe zaradi staranja svetlobnih virov.

3.1.6
svetlobni faktor inštalacije
q
inst
brezdimenzijski faktor, ki upošteva razmerje izračunane povprečne vzdrževane svetlosti cestne
površine in izračunane povprečne vzdrževane horizontalne osvetljenosti te površine ter povprečni
reducirani koeficient svetlosti iz r-preglednice, upoštevan pri izračunu svetlosti

3.2 Simboli in okrajšave

Preglednica 1: Simboli in okrajšave

Simbol ali
Ime ali opis Enota
okrajšava
2
A Področje za osvetlitev m
2
A Površina levega pločnika m

FL
2
A Površina desnega pločnika m

FR
2
A Površina vozišča m

R
AECI Kazalnik letne porabe energije
C Korekcijski faktor za projekte razsvetljave na podlagi svetlosti ali –

L
polkrogelne osvetljenosti
Koeficient delovanja razsvetljave –
c

op
CLO Konstantni svetlobni tok
–2
D Kazalnik letne porabe energije (AECI) Wh•m

E
–2
–1
D Kazalnik gostote moči (PDI) m

P W•lx •

E Povprečna vzdrževana horizontalna osvetljenost lx
E Izračunana vzdrževana osvetljenost na levem pločniku lx

FL
E Izračunana vzdrževana osvetljenost na desnem pločniku lx

FR
Polkrogelna osvetljenost lx
E

hs

Najmanjša potrebna povprečna osvetljenost lx
E
min
E Izračunana vzdrževana osvetljenost na vozišču lx

R
EIR Količnik osvetljenosti robov
f Skupni faktor vzdrževanja (MF) inštalacije razsvetljave –

M
7

---------------------- Page: 9 ----------------------
SIST EN 13201-5 : 2016

Simbol ali
Ime ali opis Enota
okrajšava
Koeficient redukcije za zmanjšani nivo razsvetljave –
k
red
–2

Povprečna vzdrževana svetlost cd•m
L
–2

Najmanjša potrebna povprečna svetlost cd•m
L
min

LOR Optični izkoristek (svetilke)
m Število obratovalnih časovnih obdobij za različne nivoje –
obratovalne moči P
MF Faktor vzdrževanja
n Število podpodročij, ki jih je treba osvetliti –
Število svetlobnih mest v povezavi z inštalacijo razsvetljave ali –
n

lp
reprezentativnim odsekom

P Sistemska moč svetilk, namenjenih za osvetlitev W
obravnavanega področja
Skupna delovna moč vseh naprav, ki niso upoštevane v W
P

ad
obratovalni moči P, vendar so vseeno potrebne za delovanje
inštalacije cestne razsvetljave
P Sistemska moč svetilke, namenjene osvetlitvi pločnika W
F
Moč svetlobnega(-ih) vira(-ov) v svetilki W
P
ls
P Sistemska moč svetilke, namenjene osvetlitvi vozišča W
R

PDI Kazalnik gostote moči
R Optični izkoristek svetilk (LOR), uporabljenih v inštalaciji –

LO
razsvetljave
Svetlobni faktor inštalacije –
q
inst
–1
Q Povprečni koeficient svetlosti
0 sr

t Trajanje obratovalnega časa za določeno sistemsko moč P v h

enem letu
Letni obratovalni čas polne osvetljenosti h
t

full
t Letni obratovalni čas zmanjšane osvetljenosti h
red

U Prostorski izkoristek inštalacije razsvetljave –
Svetlobni tok, ki pade na površino, ki jo je treba osvetliti lm
Φ

A
Svetlobni tok, ki ga oddaja(-jo) svetlobni vir(-i) v svetilki lm
Φ
ls
–1
η Svetlobni izkoristek inštalacije lm•W
inst
–1
Svetlobni izkoristek svetlobnih virov, uporabljenih v inštalaciji lm•W
η
ls
Število svetilk, vključenih v izračun –
n
lu
Izkoristek moči svetilk, uporabljenih v inštalaciji razsvetljave –
η
P



8

---------------------- Page: 10 ----------------------
SIST EN 13201-5 : 2016

4 Kazalnik gostote moči (PDI)

4.1 Izračun kazalnika gostote moči

Kazalnik gostote moči se za površino, ki je razdeljena v podpodročja za dan način obratovanja, izračuna
s pomočjo naslednje enačbe:


(1)




kjer so:

–1 –2
D kazalnik gostote moči, Wꞏlx ꞏm
P

P sistemska moč inštalacije razsvetljave za osvetlitev obravnavanega področja (glej 4.3), v W


E vzdrževana povprečna horizontalna osvetljenost podpodročja "i",
i
določena v skladu s 4.2, v lx

2
A velikost podpodročja "i", osvetljenega z inštalacijo razsvetljave, v m
i

n število osvetljenih podpodročij

Če se zahtevan svetlobnotehnični razred spreminja v nočnem času in/ali v različnih letnih obdobjih (na
primer zmanjšanje svetlobnotehničnega razreda zaradi manjše gostote prometa, sprememb vidnega
okolja ali zaradi drugih pomembnih parametrov), naj se gostota moči (D ) izračuna ločeno za vsak
P
svetlobnotehnični razred. Kot alternativa se lahko v primeru, ko so v nočnem času ali med letom
uporabljeni različni svetlobnotehnični razredi, gostota moči (D ) izračuna tudi kot povprečna vrednost v
P
obravnavanem obdobju. V izračunu morajo biti jasno navedene predpostavke, uporabljene pri izračunu
gostote moči (D ), in način, kako je bila vrednost ocenjena.
P

Za oceno energijske učinkovitosti določenega sistema razsvetljave je treba vrednosti kazalnika gostote
moči (D ) vedno podajati in uporabljati skupaj s kazalnikom letne porabe energije (D ).
P E

4.2 Povprečna horizontalna osvetljenost za izračun kazalnika gostote moči

Za svetlobnotehnične razrede na podlagi osvetljenosti (C in P) je treba povprečno vzdrževano

horizontalno osvetljenost (E) za izračun gostote moči (D ) izračunati v skladu z EN 13201-3.
P

Za svetlobnotehnične razrede na podlagi svetlosti (M) se za povprečno vzdrževano horizontalno

osvetljenost (E) za izračun gostote moči (D ) uporablja povprečna vrednost osvetljenosti, izračunana v
P
isti mreži točk, kot se je uporabila za izračun svetlosti v skladu z EN 13201-3.

Za svetlobnotehnične razrede na podlagi polkrogelne osvetljenosti (HS) se za povprečno vzdrževano

osvetljenost (E) za izračun gostote moči (D ) uporablja povprečna vrednost osvetljenosti, izračunana v
P
isti mreži točk, kot se je uporabila za izračun polkrogelne osvetljenosti v skladu z EN 13201-3.

Nekatere inštalacije cestne razsvetljave so lahko predimenzionirane, tako da zagotavljajo bistveno večje
svetlobne nivoje od zahtevanih ali določenih. Kadar se pojavi takšna preosvetlitev, naj se ugotovi, ali je
to posledica slabega načrtovanja ali se je pojavila kot nujna posledica drugih zahtev. S stališča
energijske učinkovitosti in okoljevarstvenega vidika naj se v primeru kakršnekoli preosvetlitve sprejmejo
potrebni ukrepi za njeno zmanjšanje.

S stališča energijske učinkovitosti in okoljevarstvenega vidika naj izračunani svetlobni nivoji katerekoli
razsvetljave ne presegajo zahtevanih vrednosti prvega višjega svetlobnotehničnega razreda (ali naj ne
presegajo zahtevanih vrednosti za 50 % v primeru najvišjega razreda), ne da bi se upoštevale druge
izvedbene možnosti.
9

---------------------- Page: 11 ----------------------
SIST EN 13201-5 : 2016

4.3 Sistemska moč (P) za izračun kazalnika gostote moči

Sistemska moč (P) se izračuna kot vsota obratovalnih moči svetlobnih virov, krmilnih naprav in vsake
druge električne naprave ali naprav (krmilnikov, stikal, fotočlenov in drugih naprav na svetlobnem
mestu), ki so neposredno povezani z razsvetljavo območja, ki se osvetljuje, in nameščeni z namenom
obratovanja ali krmiljenja razsvetljave. Sistemska moč (P) celotne inštalacije razsvetljave ali
karakterističnega odseka naj se izračuna po naslednji enačbi:


(2)


kjer so:

P skupna sistemska moč razsvetljave ali njenega karakterističnega odseka, v W

P obratovalna moč k-tega svetlobnega mesta svetilke (svetlobni vir, krmilna naprava, vsaka
k
druga naprava, kot so krmilnik, stikalo ali fotočlen in druge s svetlobnim mestom povezane
komponente, ki so nujno potrebne za njeno obratovanje), v W

P skupna obratovalna moč vseh naprav, ki niso zajete v P , vendar so potrebne za obratovanje
ad k
sistema razsvetljave, kot so daljinsko stikalo ali fotosenzor, centralni krmilnik svetlobnega toka
ali centralni sistem vodenja in drugo, v W

Pri izračunu sistemske moči za karakteristično območje naj bo skupna obratovalna moč P odmerjena
ad
sorazmerno z razmerjem števila svetilk, uporabljenih za razsvetljavo tega območja, in skupnim številom
svetilk, oskrbovanih z napravami, ki so zajete v P .
ad

n je število svetlobnih mest, povezanih z inštalacijo razsvetljave ali karakterističnega odseka,
lp
karkoli je bilo uporabljeno v izračunu.

Če svetlobni viri (in druge električne naprave) obratujejo s konstantno močjo, je treba za izračun
sistemske moči (P) uporabiti to moč.

Če se v nočnem času in/ali v različnih obdobjih (letnih časih) svetlobnotehnični razred spremeni (na
primer zmanjšanje svetlobnotehničnega razreda ponoči zaradi zmanjšanja gostote prometa, sprememb
vidnega okolja ali drugih pomembnih parametrov), naj se izračuna sistemska moč (P), ki ustreza
zahtevanemu svetlobnotehničnemu razredu v tem obdobju.

OPOMBA: PDI je lahko posamezna vrednost za obratovanje s stalno močjo v celotnem obdobju in 100 % vrednost pri
zatemnjevanju pri reguliranih sistemih ali pa predstavlja različne vrednosti za vsako obravnavano stopnjo
obratovanja. V dodatku A so podani primeri izračuna, v dodatku D pa primeri podajanja rezultatov.

Kadar se svetlobni tok svetlobnih virov spreminja zaradi kompenzacije sprememb oddanega
svetlobnega toka med življenjsko dobo svetlobnih virov (na primer svetlobni viri s krmilniki za konstantni
svetlobni tok (CLO)), naj se za izračun gostote moči (D ) uporabi povprečna sistemska moč v povezavi
P
s temi spremembami.

Če je izračun za glavni svetlobnotehnični razred narejen na podlagi enega samega izračuna za cestni
odsek, tj. za tipično postavitev in razdaljo med stebri, mora izračun sistemske moči (P) zajemati vsoto
moči vseh svetilk in električnih naprav, povezanih s svetilkami, svetlobnimi mesti in odseki, ki so znotraj
ali na robu polja izračuna, primernega za to tipično postavitev, skladno z EN 13201-3. Nekateri tipični
primeri so prikazani v dodatku A. Število svetilk in velikost območja morata ustrezati drug drugemu.

Če je izračun narejen za območje nepravilnih oblik, mora izračun sistemske moči (P) zajemati vsoto
moči vseh svetilk in drugih električnih naprav, povezanih s svetilkami, svetlobnimi mesti ali odseki,
potrebnih za osvetlitev območja.

Sistemska moč (P) naj ne zajema moči naprav ali z njimi povezanih učinkov, ki niso uporabljene za
namen razsvetljave, četudi so priključene na isto električno odjemno mesto. Tipični primeri so reklamni
panoji in praznična razsvetljava.
10

---------------------- Page: 12 ----------------------
SIST EN 13201-5 : 2016

4.4 Površina (A) za izračun kazalnika gostote moči

Površina, uporabljena za izračun kazalnika gostote moči (D ), mora biti enaka površini, uporabljeni pri
P
načrtovanju za izračun svetlobnotehničnih parametrov po EN 13201-2, kot je opisano v EN 13201-3.

Če vozišče na cesti ni obdano z drugimi površinami (na primer drugo vozišče, pločnik, kolesarska steza
itd., za katere so predpisane ločene svetlobnotehnične zahteve) in je količnik osvetljenosti robov (EIR
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.