This European Standard specifies requirements for the electromagnetic compatibility (EMC) for electrical apparatus for the detection and measurement of combustible gases, toxic 1) gases or oxygen. This standard applies to apparatus intended for use in residential, commercial and light-industrial environments as well as to apparatus intended for use in industrial environments. The apparatus may be AC-, DC- or battery powered. This European Standard is also applicable to apparatus which is intended for use in hazardous areas which may contain explosive or potentially explosive atmospheres. It covers only normal operation and does not cover safety requirements related to EMC phenomena. This standard specifies requirements for immunity tests in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges and also for emission tests. The test requirements are specified for each port considered. These requirements have been selected to ensure an adequate level of compatibility for apparatus at the appropriate locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrence. NOTE In special cases, situations will arise where the level of disturbances may exceed the levels specified in this standard, e.g. where an apparatus is installed in proximity to industrial, scientific or medical (ISM) equipment as specified in EN 55011 or where a hand-held transmitter is used in close proximity to an apparatus. In these instances special mitigation measures may have to be employed. Apparatus falling within the scope of this European Standard is classified as follows by the following types. – Type 1: apparatus intended for use in residential, commercial and light-industrial environments, as described in EN 61000-6-1 and EN 61000-6-3. – Type 2: apparatus intended for use in industrial environments, as described in EN 61000-6-2 and EN 61000-6-4. This European Standard does not apply to any of the following: – apparatus intended for the detection of dusts or mists in air; – scientific or laboratory based apparatus used only for analysis or measurement; – apparatus used exclusively for process measurement purposes; – apparatus for medical purposes; – apparatus intended for the direct measurement of automotive exhaust gases.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is applicable to fixed gas detection systems for the detection and measurement of flammable or toxic gases or vapours or oxygen. This European Standard supplements the requirements of the European Standards for electrical apparatus for the detection and measurement of flammable gases, vapours (e.g. EN 61779 or EN 50241), toxic gases (e.g. EN 45544) or oxygen (e.g. EN 50104). NOTE 1 These European Standards will be mentioned in the text as "metrological standards". NOTE 2 The examples above show the state of the standardisation for industrial applications at the time of publishing this European Standard. There may be other metrological standards covering other application fields, for which this standard is also applicable. NOTE 3 For fixed apparatus used for safety applications with a SIL requirement up to 1 and for portable apparatus the European Standard EN 50271 may be applied instead of this European Standard. Applying the above mentioned metrological standards will ensure the measuring performance is adequate in normal operation of a gas detection system. Additionally the requirements of this European Standard address the functional safety of gas detection systems and encompass criteria for reliability, fault tolerance and avoidance of systematic faults. This European Standard will lead to the characterisation of the gas detection system by a SIL-capability and related hardware failure rate representing a hierarchical order of safety levels. This will allow the user to incorporate the gas detection system into an overall safety system according to the safety integrity levels of EN 61508 or the categories of EN ISO 13849-1 (see Annex B). This European Standard is a product standard which is based on EN 61508 and includes additional requirements of EN ISO 13849-1. It covers part of the phase 9 “realisation” of the overall safety lifecycle defined in EN 61508-1. This European Standard is applicable for gas detection systems, which may consist of the following functional units: - gas-sampling; - sensor; - signal transmission; - input to control unit; - signal processing in control unit; - output from control unit. This European Standard does not specify requirements for the installation and maintenance of gas detection systems. It also does not specify the physical positioning of sensors.. This European Standard does not specify which SIL-capability is sufficient for which application. NOTE 4 The SIL-capability required for an application will be specified by the user (see Annexes A and B).
- Standard63 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers apparatus designed for checking the performance of heating appliances by measuring flue gas parameters of gas fired heating appliances for domestic residential and commercial applications. The apparatus may consist of different functional modules which may be tested separately for complying with this standard, and will be combined in different ways according to the different applications. The apparatus shall comply with the general requirements as specified in EN 50379 1 and the performance requirements of EN 50379 3. This European Standard specifies the performance requirements of portable spot reading apparatus designed to detect specific combustion flue gas parameters, such as concentration of gaseous compounds, temperature and/or pressure, to be used to decide if maintenance for the appliance is required and for adjusting the appliance during maintenance. This standard excludes apparatus for – checking appliances using fuels other than gas, – continuous emission, safety monitoring and control, and – use in vessels with an international load line. NOTE 1 When this apparatus is used in industrial premises, national regulations shall be observed. NOTE 2 Apparatus may contain functional modules which are not covered by this standard e.g. measurement of smoke spot number (see Annex A of EN 267).
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers apparatus for measuring gas concentrations and other combustion parameters, as used in the installation and maintenance of heating appliances. Such apparatus may be used for testing the performance of appliances for different types of fuels, either by the installer, maintenance engineer or inspector. The apparatus may consist of different functional modules, which may be tested separately for complying with this standard and will be combined in different ways according to the different applications. The apparatus shall comply with requirements as specified in EN 50379 2 and/or EN 50379 3. This European Standard specifies general requirements for the construction, testing and performance of portable spot reading apparatus designed to give an assessment of specific combustion flue gas parameters, such as concentration of gaseous compounds, temperature and/or pressure, to check the combustion performance of heating appliances for domestic residential and commercial applications, using commercially available fuels. This standard excludes apparatus for – continuous emission, safety monitoring and control, and – use in vessels with an international load line. NOTE 1 When this apparatus is used in industrial premises national regulations may apply. NOTE 2 Apparatus may contain functional modules which are not covered by this standard e.g. measurement of smoke spot number (see Annex A of EN 267).
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60079-29-4:2010
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 60079-29-1:2007
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50104:2010
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50104:2010
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50271:2010
- Standard9 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies general requirements for construction and testing and describes the test methods that apply to portable, transportable and fixed apparatus for the detection and measurement of flammable gas or vapour concentrations with air. The apparatus, or parts thereof, are intended for use in potentially explosive atmospheres and in mines susceptible to firedamp.
- Standard62 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies requirements for group I (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of methane concentrations in mine air. The apparatus, or parts thereof, are intended for use in mines susceptible to firedamp. The requirements and test methods applicable to the apparatus covered by this standard are specified in part 1. This standard is restricted to apparatus intended for the detection and measurement of volume ratios of methane in air from a volume fraction of 0 % up to a volume fraction of 100 %.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies requirements for group I (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of methane concentrations in mine air. The apparatus, or parts thereof, are intended for use in mines susceptible to firedamp. The requirements and test methods applicable to the apparatus covered by this standard are specified in part 1. This standard is restricted to apparatus intended for the detection and measurement of volume ratios of methane in air from a volume fraction of 0 % up to, but not exceeding, a volume fraction of 5%.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies requirements for group II (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of combustible gas or vapour concentrations with air. The apparatus, or parts thereof, may be installed or used in potentially explosive atmospheres, other than mines susceptible to firedamp (i.e. group I). This standard is restricted to apparatus intended for the detection and measurement of volume ratios of combustible gas or vapour in air in volume fractions from 0% to 100%.
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
Specifies requirements for group II (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of combustible gas or vapour concentrations with air. The apparatus, or parts thereof, may be installed or used in potentially explosive atmospheres, other than mines susceptible to firedamp (i.e. group I). This standard is restricted to apparatus intended for the detection and measurement of combustible gas or vapour concentrations with air up to 100% lower explosive limit (LEL).
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
This guide provides information on the selection, installation, use and maintenance of apparatus for the detection of combustible gas designed for continuous operation in a fixed installation in domestic premises as described in EN 50194. This guide should be read in conjunction with any additional relevant national or local regulations. The guide refers to the installation of two types of apparatus designed to operate in the event of an escape of town gas, natural gas or liquefied petroleum gas: Type A apparatus - to provide a visual and audible alarm and an executive action in the form of an output signal that may actuate directly or indirectly a shut-off device and/or other ancillary device. Type B apparatus - to provide visual and audible alarm only. This guide is not applicable to the use of apparatus: used in boats, caravans or mobile homes; for the detection of toxic gases such as carbon monoxide, see EN 50292; for industrial or commercial premises, see EN 50073.
- Standard13 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50194-1:2009
- Standard22 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for the electromagnetic compatibility (EMC) for electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen. This standard applies to apparatus intended for use in the residential, commercial and light-industrial environment as well as to apparatus intended for use in the industrial environment. The apparatus may be a.c.-, d.c.- or battery powered. This European Standard is also applicable to apparatus which is intended for use in hazardous areas which may contain explosive or potentially explosive atmospheres. This standard specifies requirements for immunity tests in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges and also for emission tests. The requirements are specified for each considered port. These requirements have been selected so as to ensure an adequate level of compatibility for apparatus at the appropriate locations. The levels do not however cover extreme cases which may occur in any location but with an extremely low probability of occurrence. NOTE: In special cases situations will arise where the level of disturbance may exceed the levels specified in this standard, e.g. where an apparatus is installed in proximity to industrial, scientific or medical (ISM) equipment as specified in EN 55011 or where a hand-held transmitter is used in close proximity to an apparatus. In these instances special mitigation measures may have to be employed. Apparatus falling within the scope of this European Standard is classified as follows by the following types. Type 1: apparatus intended for use in the residential, commercial and light-industrial environment, as described in EN 50081-1 and EN 50082-1. Type 2: apparatus intended for use in the industrial environment, as described in EN 50081-2 and EN 50082-2. This European Standard does not apply to any of the following: apparatus intended for the detection of dusts or mists in air; scientific or laboratory based apparatus used only for analysis or measurement; apparatus used exclusively for process measurement purposes; apparatus for medical purposes; apparatus intended for the direct measurement of automotive exhaust gases
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
This document gives guidance on the selection, installation, use and maintenance of electrically operated Group II apparatus intended for use in industrial and commercial safety applications for the detection and measurement of: combustible gases, as described in EN 50054, EN 50057, EN 50058 or oxygen as described in EN 50104. This guide is a compilation of practical knowledge to assist the user. Combustible gas detection apparatus, fixed, transportable or portable, may be used whenever there is the possibility of a risk to life or property caused by the accumulation of a combustible gas-air mixture. Such apparatus can provide a means of reducing the risk by detecting the presence of the combustible gas and issuing suitable audible or visual warnings. It may also be used to initiate specific safety precautions (e.g. plant shutdown, evacuation, operation of fire extinguishing procedures). It is applicable to all new permanent installations and, where reasonably practicable, to existing permanent installations. It is also applicable to temporary installations, whether new or existing. This Guide is not intended, but may provide useful information, for the following apparatus intended for the measurement of oxygen deficiency which may affect human health, apparatus intended only for the detection of non-combustible toxic gases; apparatus of laboratory or scientific type intended only for analysis or measurement purposes; Apparatus intended for underground mining applications; apparatus intended only for process control applications; This Guide does not apply to the following: apparatus for the detection of explosives; apparatus intended for the detection of a potentially combustible atmosphere resulting from dust or mist in air; open path apparatus not used for point measurement
- Standard39 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies general requirements for the construction and testing of apparatus for the detection and measuring of combustible or toxic gases or vapours in ambient air by measuring the spectral absorption by the gases or vapours over extended optical paths, ranging typically from one meter to a few kilometers. Such apparatus measures the integral concentration of the absorbing gas over the optical path in units such as LEL meter for combustible gases and ppm meter for toxic gases. NOTE 1: Actual values of concentration can only be deduced where it can be established that the concentration is uniform over the optical path, as for example in very short optical paths (<100 mm). In such cases, the apparatus is within the scope of EN 50054 - EN 50058 and prEN 45544-1 to prEN 45544-4. Apparatus falling within the scope of this European Standard is classified as follows by the following types. Type 1: an optical transmitter and receiver, located at either end of a path through the atmosphere to be monitored. Type 2: an optical transceiver (i.e. combined transmitter and receiver) and a suitable reflector, which may be a topographic feature or a retroreflector, located at either end of a path through the atmosphere to be monitored. This European Standard does not apply to any of the following: 1. Apparatus intended to provide range resolution of gas concentration (e.g. LIDAR), 2. Apparatus consisting of a passive optical receiver without a dedicated optical source, 3. Apparatus intended to measure the local volumetric concentration of gas (point sensors), 4. Apparatus intended for the detection of dusts or mists in air, 5. Apparatus for cross stack monitoring, 6. Apparatus intended for the detection of explosives and vapours, and 7. Apparatus intended for quantitative and simultaneous multicomponent analysis, e.g. FTIR. This European Standard covering general requirements and test methods is supplemented by the following European Standard concerning specific requirements of performance: EN 50241-2: Performance requirements for apparatus for the detection of combustible gases. This European Standard is applicable to apparatus which is intended for use in both hazardous and non hazardous areas. Apparatus for use in hazardous areas which may contain potentially combustible atmospheres is required to be designed for safe operation, see 4.1.2. This European Standard applies to transportable, and fixed apparatus intended for commercial and industrial applications. NOTE 2: This European Standard and EN 50241-2 as referenced above are intended to provide for the supply of apparatus giving a level of performance suitable for general purpose applications. However, for specific applications a prospective purchaser or an appropriate authority may additionally require apparatus to be submitted to particular tests or approval. Such tests or approval are to be regarded as additional to and separate from the provisions from the European Standards
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies performance requirements for Group II portable, transportable and fixed apparatus for the detection and measurement of integral concentrations of combustible gas or vapour in air over a defined open path. The apparatus, or parts thereof, may be installed or transported for use in potentially explosive atmospheres. The general requirements and test methods applicable to the apparatus covered by this European Standard are specified in Part 1. This European Standard concerns apparatus intended to provide measurement or warning of specific combustible gases in air which constitute a potential hazard by virtue of their flammability. Open path detection apparatus as covered by this European Standard measures the path integral concentration. It is not capable of resolving the spatial variation of concentration along the optical path
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies performance requirements and test methods for portable, transportable and fixed electrical apparatus for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v). This European Standard applies to apparatus intended for commercial and industrial safety applications, including integral sampling systems of aspirated apparatus. In the case of inert gas purging, this European Standard applies also to apparatus with an oxygen measuring function for explosion protection. It does not apply to external sampling systems, nor laboratory, scientific or medical equipment nor those which are used exclusively for process control. NOTE: The most commonly used oxygen sensors in commercial equipment for industrial application are: paramagnetic sensors; electrochemical sensors (aqueous and solid electrolytes)
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies performance requirements for Group I (as defined in European Standard EN 50054) portable, transportable and fixed apparatus for the detection and measurement of methane concentrations in mine air. The apparatus, or parts thereof, are intended for use in mines susceptible to firedamps and shall meet the general requirements and test methods specified in EN 50054.This European Standard is restricted to apparatus intended for the detection and measurement of methane volume ratios in air from 0 % (v/v) up to but not exceeding 5 % (v/v)
- Standard7 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies performance requirements for Group I (as defined in EN 50054) portable, transportable and fixed apparatus for the detection and measurement of methane concentrations in mine air. The apparatus, or parts thereof, are intended for use in mines susceptible to firedamp and shall meet the general requirements and test methods specified in EN 50054. This European Standard is restricted to apparatus intended for the detection and measurement of volume ratios of methane in air from 0 % (v/v) up to 100 % (v/v). NOTE: Apparatus covered by this European Standard will normally be intended to operate in volume ratios greater than 5 % (v/v)
- Standard7 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies general requirements for construction and testing and describes the test methods that apply to portable, transportable and fixed apparatus for the detection and measurement of combustible gas or vapour concentrations with air. The apparatus, or parts thereof, is intended for use in potentially explosive atmospheres and in mines susceptible to firedamp. This European standard is supplemented by the following European Standards, concerning the specific requirements for performance of the various types of apparatus:EN 50055: Performance requirements for Group I apparatus indicating up to 5 % (v/v) methane in air; EN 50056: Performance requirements for Group I apparatus indicating up to 100 % (v/v) methane EN 50057: Performance requirements for Group II apparatus indicating up to 100 % lower explosive limit; EN 50058: Performance requirements for Group II apparatus indicating up to 100 % (v/v) gas- NOTE 1: Group I apparatus indicating up to 100 % (v/v) methane and Group II apparatus indicating up to 100 % (v/v) gas are suitable for use only with the specific gases for which they have been calibrated. NOTE 2: For the purposes of this European Standard the term 'combustible gas' includes combustible vapours but excludes mist and dust, see 3.3 note 1. This European Standard is applicable to combustible gas detection apparatus intended to provide an indication) alarm and/or other output function, the purpose of which is to give a warning of potential explosion hazard and in some cases to initiate automatic or manual protective actions. This European Standard is applicable to apparatus, including the integral sampling systems of aspirated apparatus intended to be used for commercial and industrial safety applications. This European Standard does not apply to external sampling systems, or to apparatus of the laboratory or scientific types, or to apparatus used only for process control purposes
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies performance requirements for Group II (as defined in EN 50054) portable, transportable and fixed apparatus for the detection and measurement of combustible gas or vapour concentrations with air. The apparatus, or parts thereof, may be installed or used in potentially explosive atmospheres, other than mines susceptible to firedamp (i.e. Group I). The general requirements and test methods applicable to the apparatus covered by this European Standard are specified in EN 50054. This European Standard is restricted to apparatus intended for the detection and measurement of combustible gas or vapour concentrations with air up to 100 % lower explosive limit (LEL). NOTE: Although apparatus of the types covered by this European Standard may be suitable for detecting a wide range of combustible gases, particular gases (e.g. methane or propane) are specified in EN 50054 as the components of the test gases for the purpose of practical convenience. The performance requirements specified in this European Standard must therefore be regarded with caution when the apparatus is used to detect other combustible gases, as some parameters - such as speed of response - will be modified
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies performance requirements for Group II (as defined in EN 50054) portable, transportable and fixed apparatus for the detection and measurement of combustible gas or vapour concentrations with air. The apparatus, or parts thereof, may be installed or used in potentially explosive atmospheres, other than mines susceptible to firedamp (i.e. Group I). The general requirements and test methods applicable to the apparatus covered by this European Standard are specified in EN 50054.This European Standard is restricted to apparatus intended for the detection and measurement of volume ratios of combustible gas or vapour in air from 0 % (v/v) to 100 % (v/v).NOTE 1: Apparatus covered by this European Standard will normally be intended to operate in volume ratios greater than 100 % LEL. NOTE 2: Although apparatus of the types covered by this European Standard may be suitable for detecting a wide range of combustible gases, particular gases (e.g. methane or propane) are specified in EN 50054 as the components of the test gases for the purpose of practical convenience. The performance requirements specified in this European Standard must therefore be regarded with caution when the apparatus is used to detect other combustible gases, as some parameters - such as time of response - will be modified
- Standard7 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50054:1998
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50056:1998
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50055:1998
- Amendment2 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50057:1998
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 This European Standard specifies performance requirements for Group I (as defined in European Standard EN 50054) portable, troansportable and fixed apparatus for the detection and measurement of methane concentrations in mine air. The apparatus, or parts thereof, are intended for use in mines susceptible to firedamp and shall meet the general requirements and test methods specified in European Standard EN 50054. NOTE. The use of Group I apparatus may not be permitted without the additional and prior approval of the relevant authority in mines under it juridiction, see Note 1 under Clause 1.1 of European Standards EN 50054. 1.2 This European Standard is restricted to apparatus intended for the detection and measurement of volume ratios of methane in air from 0 % (v/v) up to 100 % (v/v). NOTE. Apparatus covered by this European Standard will normally be intended to operate in volume ratios greater than 5 % (V/V).
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
1.1 This European Standard specifies performance requirements for Group I (as defined in European Standard EN 50 054) portable, transportable and fixed apparatus for the detection and measurement of methane concentrations in mine air. The apparatus, or parts thereof, are intended for use in mines susceptible to firedamps and shall meet the General requirements and test methods specified in European Standard EN 50054. NOTE. The use of Group I apparatus may not be permitted without the additional and prior approval of the relevant authority in mines under its jurisdiction, see Note 1 under clause 1.1 of European Standard EN 50054. 1.2 This European Standard is restricted to apparatus intended for the detection and measurement of methane volume ratios in air from 1 % (v/v) up to but not exceeding 5 % (v/v).
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
Corrigendum to EN issued October 1991 * Superseded by EN 50058:1998
- Standard10 pagesEnglish languagesale 10% offe-Library read for1 day
Superseded by EN 50054:1998
- Standard52 pagesEnglish languagesale 10% offe-Library read for1 day