These standards (EN 13284-1 and -2) have been published for over 10 years without revision. Significant advances have happened in the measurement of particulate at low concentration using continuous methods. Also various research studies carried out in the UK have indicated that there are some aspects of measuring low concentration of dust by the manual method require strengthening. Sections to be added should include: 1. filter preparation, conditioning and handling, 2. the number of samples re...view more

    • sale 10% off
    • Standard
      33 pages
      English language
    • e-Library read for
      1 day

ISO/IEC 17025:2017 specifies the general requirements for the competence, impartiality and consistent operation of laboratories.
ISO/IEC 17025:2017 is applicable to all organizations performing laboratory activities, regardless of the number of personnel.
Laboratory customers, regulatory authorities, organizations and schemes using peer-assessment, accreditation bodies, and others use ISO/IEC 17025:2017 in confirming or recognizing the competence of laboratories.

    • sale 10% off
    • Standard
      39 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard – translation
      51 pages
      Slovenian and English language
    • e-Library read for
      1 day

This European Standard specifies a reference method for the measurement of low dust concentration in ducted gaseous streams in the concentrations below 50 mg/m3 at standard conditions. This European Standard is primarily developed and validated for gaseous streams emitted by waste incinerators. More generally, it may be applied to gases emitted from stationary sources, and to higher concentrations. If the gases contain unstable, reactive or semi-volatile substances, the measurement depends on th...view more

    • sale 10% off
    • Standard
      63 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies a procedure to demonstrate the equivalence of an alternative method (AM) with the reference method (RM) or the standard reference method (SRM), both implemented to determine the same measurand.
In particular, this European Standard provides the statistical tools and different criteria to evaluate the alternative method. This does not release the body performing the equivalence testing from bearing technical and analytical judgement on the evaluation of the diff...
view more

    • sale 10% off
    • Standard
      34 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the standard reference method (SRM) for the determination of the sulphuric oxide SO2 in flue gases emitted to the atmosphere from ducts and stacks. It is based on a sampling system and two analytical principles: ion chromatography and the Thorin method.
This European Standard specifies the performance characteristics to be determined and the performance criteria to be fulfilled by measuring systems based on the measurement method. It applies to periodic monitor...
view more

    • sale 10% off
    • Standard
      69 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the standard reference method (SRM) based on the paramagnetic principle for the determination of the oxygen concentrations in flue gases emitted to the atmosphere from ducts and stacks. It includes the sampling and the gas conditioning system as well as the analyser.
This European Standard specifies the performance characteristics to be determined and the performance criteria to be fulfilled by measuring systems based on this measurement method. It applies to p...
view more

    • sale 10% off
    • Standard
      41 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the standard reference method (SRM) based on the chemiluminescence principle for the determination of the nitrogen oxides (NOx) in flue gases emitted to the atmosphere from ducts and stacks. It includes the sampling and the gas conditioning system, as well as the analyser.
This European Standard specifies the characteristics to be determined and the performance criteria to be fulfilled by measuring systems based on this measurement method. It applies for period...
view more

    • sale 10% off
    • Standard
      56 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the standard reference method (SRM) based on the infra-red (IR) absorption principle. It includes the sampling and the gas conditioning system, and allows the determination of the carbon monoxide CO in flue gases emitted to the atmosphere from ducts and stacks.
This European Standard specifies the characteristics to be determined and the performance criteria to be fulfilled by measuring systems using the IR measurement method. It applies for periodic monitoring ...
view more

    • sale 10% off
    • Standard
      50 pages
      English language
    • e-Library read for
      1 day

This Technical Specification CEN/TS 1948-5 specifies the long-term sampling of PCDD/PCDF/PCB concentrations in emissions of stationary sources. It is intended to base the new method on EN 1948 Part 2, 3, 4 "Analyses of PCDD/PCDF/PCB".
The development of the new method is necessary due to the enhanced demand of several European countries and of the European Commission with regard to possible amendment of the Waste Incineration Directive 2000/76.
http://ec.europa.eu/environment/air/stationary.h...
view more

    • sale 10% off
    • Technical specification
      80 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies sampling from stationary sources, extraction, clean-up, identification and quantification procedures of the dioxin-like PCBs. The procedure described lays down requirements to measure the PCB congeners given in Annex A (see Table A.1). It is applicable to the 12 non- and mono-ortho PCB designated by the WHO. It is optimised to measure PCB concentrations of about 0,01 ng WHOTEQPCB/m3. In addition to the 12 non- and mono-ortho-PCB the present document is also appli...view more

    • sale 10% off
    • Standard
      63 pages
      English language
    • e-Library read for
      1 day

The method specified in this European Standard is designed for use as a standard reference method.This European Standard specifies a set of minimum performance requirements for an instrument using flame ionization detection, together with procedures for its calibration and operation, for the measurement of the mass concentration of total gaseous organic carbon (TOC) and for solvent emissions total volatile organic compounds (TVOC) in stationary source emissions.This European Standard is suitable...view more

    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day

The method described in this European Standard determines the concentration of chlorinated compounds in a flue gas that - after passage of the sampling system including a particle filter - give Cl- ions in the absorption solution. This Standard Reference Method has been evaluated during field tests on waste incineration. The method applies to waste gases in which chlorides concentration expressed as HCl may vary between 1 mg-m-3 and 5 000 mg-m-3 under normal pressure and temperature conditions (...view more

    • sale 10% off
    • Standard
      46 pages
      English language
    • e-Library read for
      1 day

This International Standard is applicable to the measurement of the gaseous fluorides that are entrained in gases carried in stacks or ducts. The gaseous fluoride content is expressed as a mass of hydrogen fluoride in the stack gas. This International Standard is applicable to all stacks emitting gases with fluoride concentrations of below 200 mg/m3. It can be used for higher concentrations, but then the absorption efficiency of the bubblers should be checked before the results can be regarded a...view more

    • sale 15% off
    • Standard
      14 pages
      English language
    • sale 10% off
    • Standard
      22 pages
      English language
    • e-Library read for
      1 day
    • sale 15% off
    • Standard
      15 pages
      French language

This European Standard specifies the identification and quantification procedures of the sampled PCDDs/PCDFs. It is an integral part of the complete measurement procedure. The use of the other two parts of this standard, EN 1948-1:2006 and EN 1948-2:2006, describing sampling and extraction and clean-up, respectively, is necessary for the determination of the PCDDs/PCDFs. This European Standard has been designed to measure PCDD/PCDF concentrations at about 0,1 ng ITEQ/ m3 in stationary source emi...view more

    • sale 10% off
    • Standard
      48 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the extraction and clean-up procedures of the sampled PCDDs/PCDFs. It is an integral part of the complete measurement procedure. The use of the other two parts EN 1948-1:2006 and EN 1948-3:2006 describing sampling or identification and quantification, respectively, is necessary for the determination of the PCDDs/PCDFs. This European Standard has been designed to measure PCDD/PCDF concentrations at about 0,1 ng I-TEQ/m3 in stationary source emissions. This Europea...view more

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the sampling of PCDDs/PCDFs. It is an integral part of the complete measurement procedure. The use of the other two parts EN 1948-2 and EN 1948-3 describing extraction and clean-up and identification and quantification, respectively, is necessary for the determination of the PCDDs/PCDFs. This European Standard has been developed to measure PCDD/PCDF concentrations at about 0,1 ng I-TEQ/m3 in stationary source emissions. This European Standard specifies both metho...view more

    • sale 10% off
    • Standard
      64 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies specific requirements on automated measuring systems (AMS) for monitoring of total mercury. It is derived from EN 14181, which is the general document on the quality assurance of AMS. It is only applicable in conjunction with EN 14181.
This European Standard sets specific requirements for the quality assurance levels and annual surveillance test as specified in EN 14181, for mercury AMS used for proving that the mercury emissions from a source are compliant with...
view more

    • sale 10% off
    • Standard
      18 pages
      English language
    • e-Library read for
      1 day

TC - Addition of a caution notice after 6.3.2

    • sale 10% off
    • Corrigendum
      2 pages
      English, French and German language
    • e-Library read for
      1 day

This European Standard specifies a manual reference method for the determination of the mass concentration of specific elements in exhaust gases from hazardous waste incinerators. The method is applicable to each of the specific elements in the concentration range of 0,005 mg/m3 to 0,5 mg/m3. Unless otherwise stated, gas volumes are expressed at dry conditions, normalised to 273 K and oxygen content 101,3 kPa, and normalized to a dry oxygen content of 11 % on the volume/volume basis.
Specific e...
view more

    • sale 10% off
    • Standard
      40 pages
      English language
    • e-Library read for
      1 day

This European standard specifies a manual reference method for the determination of the mass concentration of mercury in exhaust gases from ducts and chimneys. The method is applicable for the concentration range of total mercury from 0,001 to 0,5 mg/m3 in exhaust gases with the following composition: total suspended matter from 0 to 20 mg/m3; CxHy from 0 to 10 mg/m3; HCl from 0 to 50 mg/m3; HF from 0 to 10 mg/m3; SO2 from 0 to 250 mg/m3; NOx from 0 to 500 mg/m3; CO2 from 0 to 15 vol%; H2O (g) f...view more

    • sale 10% off
    • Standard
      26 pages
      English language
    • e-Library read for