CEN/TC 203 - Cast iron pipes, fittings and their joints
Standardization of cast iron pipes, fittings, accessories, and their joints for water supply, drainage and sewerage, gas supply and other application. Valves, pumps and malleable iron parts are excluded.
Cevi in fazonski komadi iz litega železa ter elementi za njihovo spajanje
Standardization of cast iron pipes, fittings, accessories, and their joints for water supply, drainage and sewerage, gas supply and other application. Valves, pumps and malleable iron parts are excluded.
General Information
This document is applicable to diffusion-tight pipes, accessories and fittings in ductile cast iron to EN 598 and to cast iron pipe systems.
The document gives requirements on the contact pressure based on a risk assessment and gives a test method that simulates the penetration of a root tip into the sealing gap.
- Standard11 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard is a complementary document for the installation of ductile iron pipes, fittings, accessories and their joints, covered by EN 598:2009 harmonized standard. It is intended to describe, in a wider perspective, installation technologies, tools and pipelines particular examples, applicable for the construction, outside buildings, of:
- Drainage pipeline systems;
- Raw water pipeline systems;
- Sewage pipeline systems;
- Pipeline systems conveying surface water (e.g. rainwater), domestic waste water and/or certain types of industrial effluents, either in separate systems or in combined systems;
- Operating without pressure (gravity sewers) or with positive or negative pressure;
- Below or above ground installation types.
It also gives some site operation/site instructions for the application of fittings, intended to be used for the connection of ductile iron drains and sewers to other materials as plastic, concrete, vitrified clay, etc.
This European Standard is not intended to cover:
- Hydraulic design of drains and sewers systems outside buildings. For this purpose, EN 16933-2 applies.
- Construction and site testing of drains and sewers. For this purpose, EN 1610 applies.
- Trenchless construction and testing of drains and sewers. For this purpose, EN 12889:2000 applies
- Technical report56 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the evaluation method of life cycle cost (LCC) and Life cycle assessment (LCA) of ductile iron pipes and fittings used for water applications and which are in compliance with EN 545.
LCC evaluation is based on concepts and methods developed in ISO 15686 5.
LCA evaluation is based on concepts and methods developed in ISO 15686 6, EN 15804:2012+A2:2019, EN ISO 14040 and EN ISO 14044.
In this document, LCA is limited to the evaluation of environmental impact due to CO2 emissions associated with the consumption of natural resources or energy and waste disposal. The other categories of impacts are not in the scope of this document.
Informative annexes are included in this document as a compilation of references, consensual factors, and scenarios with different DI pipelines.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and associated test methods applicable to wide tolerance ductile iron and steel (restricted sizes for steel) couplings, stepped/reducing couplings and flange adaptors intended for use with pipe components made from a number of pipe materials (ductile iron, grey iron, PE in conformity with EN 12201-1 to EN 12201-5, PVC-U in conformity with EN ISO 1452-1 to EN ISO 1452-5, PVC-O in conformity with EN 17176-1 to EN 17176-5, steel, fibre-cement), for providing a leak tight seal over a wide range of pipe outside diameters:
- to convey water (e.g. water intended for human consumption);
- with or without pressure;
- to be installed below or above ground, inside or outside buildings.
This document is not intended to cover sewerage or gas applications, where additional requirements may be necessary.
This document specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of products.
This document covers wide tolerance couplings, stepped/reducing couplings and flange adaptors:
- manufactured with socketed or flanged ends;
- supplied externally and internally coated;
- suitable for pipes made from ductile iron in conformity with EN 545, grey iron, PE in conformity with EN 12201-1 to EN 12201-5, PVC-U in conformity with EN ISO 1452-1 to EN ISO 1452-5, PVC-O in conformity with EN 17176-1 tot EN 17176-5, steel, fibre-cement in a size range extending from DN 40 to DN 800, for an allowable operating pressure (PFA) up to 16 bar, for fluid temperatures between 0 °C and 25 °C excluding frost. For higher temperatures, (up to 45 °C for PVC-U and PVC-O or 40 °C for PE) the PFA is derated as given in EN ISO 1452 and EN 12201;
- not intended for use in areas subjected to reaction to fire regulations.
NOTE 1 This does not preclude special arrangements for the products to be used at higher temperatures. Temperature limitations and pressure limitations are those coming from the PVC-U, PVC-O or PE pipes.
This document covers ductile iron couplings, stepped/reducing couplings and flange adaptors cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, in a size range extending from DN 40 to DN 800.
As long as no equivalent European Standard exists for steel accessories, this document also covers couplings and flange adaptors which are fabricated partly or entirely from steel as well as corresponding joints, in a size range extending from DN 600 to DN 800.
This document specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings. It also gives minimum performance requirements for all components, including restrained and non-restrained flexible joints. Joint design and gasket shapes are outside the scope of this document.
NOTE 2 PFA can be limited depending on pipe materials effectively connected.
NOTE 3 In this document, if not specified, all pressures are relative gauge pressures, expressed in bars (100 kPa = 1 bar).
- Standard34 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies product characteristics, test/assessment methods and how to express test/assessment results. Cast iron pipelines kits are usually composed of cast iron pipes, fittings, joints and accessories.
This document covers the range of nominal diameter from DN 40 to DN 600 inclusive.
The cast iron includes grey cast iron and ductile cast iron.
The roof gullies used for siphonic systems are outside the scope of this document.
Sewerage applications are outside the scope of this document.
It is intended to be used for the construction of gravity or vacuum discharge pressurized or unpressurised networks installed inside and/or outside works, above and/or below ground and in construction works.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods applicable to factory applied internal lining made of thermoplastic acid modified polyolefin (TMPO) for the heavy duty corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969. This document also applies to pipes with only socket and spigot ends coated with TMPO. Fittings and accessories are covered separately by EN 14901-2.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and test methods applicable to factory applied extruded polyethylene coatings for the external corrosion protection of ductile iron pipes according to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
This document is not applicable to ductile iron pipes protected with thin PE sleeve. Special works at site like drilling, tapping, etc. can influence the corrosion protection properties. Those job steps are intended to be included in the instructions of pipe saddle and accessory manufacturers and all other essential installation instructions. These instructions are not part of this document.
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
This document defines the requirements and test methods for factory applied thermoplastic acid modified polyolefin (TMPO) coatings used for the protection of ductile iron fittings and accessories according to EN 545, EN 598, EN 969, EN 12842 and EN 14525:
- conveying water (e.g. potable water, raw water, …) at operating temperature up to 50 °C; or
- conveying waste water at operating temperature up to 45 °C; or
- conveying gas at operating temperature up to 50 °C;
- suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in D.2.3 of EN 545:2010.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder or liquid two-pack) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
- conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
- conveying waste water at operating temperature up to 45 °C excluding frost; or
- conveying gas at operating temperature up to 50 °C;
- suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in EN 545:2010, D.2.3.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods applicable to factory applied internal polyurethane high duty corrosion protection of buried ductile iron pipes and fittings conforming to EN 545, EN 598 and EN 969 for use at permanent operating temperatures up to 45 °C
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report contains the sanitary characteristics and test methods applicable to those factory applied lining, coating and jointing materials of ductile iron pipes and fittings conforming to EN 545 which are in contact with water intended for human consumption for use at operating temperatures up to 50 °C. Ductile cast iron itself is not in direct contact with the conveyed water therefore no characteristics in respect to the sanitary behaviour are necessary. As ductile cast iron is impermeable against diffusion of organic substances the water quality is maintained in service. Different surface/volume ratios are used in the tests for pipes, fittings and joints to reflect the different impact of their surface areas exposed to the water in the overall pipeline.
- Technical report16 pagesEnglish languagesale 10% offe-Library read for1 day
This Technical Report applies to all water and sewerage applications of ductile iron pipe systems and provides a structure on how to identify and consider environmental aspects and potential environmental impacts of ductile iron pipe systems throughout their life cycle.
This Technical Report gives guidance on how the life cycle of ductile iron pipelines should be considered in accordance with EN ISO 14044. This Technical Report also includes health and safety aspects related to the production, use and recycling of ductile iron pipe systems.
- Technical report9 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron fittings, ductile iron and mild steel couplings and flange adaptors and their joints to be used with poly(vinyl chloride) (PVC-U) pipes or polyethylene (PE) pipes. It is in conformity with EN 1452-1 to -5, ENV 1452-6 and -7 and EN 12201-1 to -5 respectively, for the construction of pipelines:
- to convey water (e.g. water intended for human consumption);
- with or without pressure;
- to be installed below or above ground, inside or outside buildings.
This European Standard is not intended to cover sewerage applications, where additional requirements may be necessary.
This European Standard is applicable to fittings which are:
- manufactured with socketed, flanged or spigot ends;
- supplied externally and internally coated;
- suitable for PE and PVC-U pipes with fluid temperatures between 0°C and 25°C, excluding frost, and for pressures up to 16 bar (PFA). For higher temperatures (up to 45°C for PVC-U or 40°C for PE) the PFA is derated as given in EN 1452 and EN 12201;
- not intended for use in areas subjected to reaction to fire regulations.
NOTE 1 This does not preclude special arrangements for the products to be used at higher temperatures. Temperature limitations and pressure limitations are those coming from the PVC-U or PE pipes.
This European Standard covers ductile iron fittings, couplings and flange adaptors cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, in a size range extending from DN 60 to DN 700, to be used with pipes of external diameter from 63 mm to 710 mm.
As long as no equivalent European Standard exists for mild steel accessories, this European Standard also covers couplings and flange adaptors for use with PVC-U and PE pipes which are fabricated partly or entirely from mild steel as well as corresponding joints, in a size range extending from DN 60 to DN 700, to be used with pipes of external diameter from 63 mm to 710 mm.
This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings. It also gives minimum performance requirements for all components, including restrained and non-restrained flexible joints. Joint design and gasket shapes are outside the scope of this standard.
This European Standard does not cover fittings, couplings and flange adaptors intended to be used with different pipe materials other than PVC-U and PE.
NOTE 2 Fittings, couplings and flange adaptors complying with the requirements of this European Standard for PVC-U also usually meet the requirements for PVC-O and PVC-A pipes. Where this is not the case, the manufacturer is expected to declare this in the relevant literature.
NOTE 3 In this European Standard, all pressures are relative pressures, expressed in bars (100 kPa = 1 bar).
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of pipelines outside buildings:
- to convey different types of water (e.g. raw water, treated water, re-used water) for all types of applications (e.g. water intended for human consumption, for fire protection, for snow making, for irrigation, for hydro-electricity etc.);
- with or without pressure;
- to be installed below or above ground.
This European Standard is applicable to pipes, fittings and accessories which are:
- manufactured with socketed, flanged or spigot ends;
- supplied externally and internally coated;
- suitable for fluid temperatures between 0 °C and 50 °C, excluding frost;
- not intended for use in areas subject to fire regulations.
NOTE 1 This does not preclude special arrangements for the products to be used at higher temperatures.
This European Standard covers pipes and fittings cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints and accessories, in a size range extending from DN 40 to DN 2 000, inclusive.
This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron pipes and fittings. It also gives performance requirements for all components including joints. Joint design and gasket shapes are outside the scope of this standard.
In addition, reference is made to the performance requirements of couplings, flange adaptors and saddles manufactured for use with ductile iron pipes and fittings.
NOTE 2 In this European Standard, all pressures are relative pressures, expressed in bars (100 kPa = 1 bar).
- Standard93 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard + National Annex and/or Foreword96 pagesForeword and/or annex in Slovenian language, body of the standard in English languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints used for the construction of external pipelines:
- to convey air or combustible gases (e.g. natural gas or town gas) at pressures up to 16 bar;
- to be installed below or above ground.
NOTE 1 A combustible gas is a gas or any fuel that is in gaseous state at a temperature of 15 °C at a pressure of 1 bar.
This European Standard applies to pipes, fittings and accessories which are:
- manufactured with socketed, flanged or spigot ends;
- normally delivered externally and internally coated;
- suitable for gas temperatures between - 15 °C and 50 °C.
This European Standard covers pipes, fittings and accessories cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, in a size range extending from DN 40 to DN 600 inclusive.
This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron pipes and fittings. It also gives performance requirements for all components including joints. Joint design and gasket shape are outside the scope of this European Standard.
NOTE 2 In this European Standard, all pressures are relative pressures expressed in bars (100 kPa = 1 bar).
- Standard73 pagesEnglish languagesale 10% offe-Library read for1 day
EN 598 specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of drains and sewers outside buildings:
- operating without pressure (gravity sewerage), or with positive or negative pressure;
- to be installed below or above ground;
- to convey surface water, domestic waste water and certain types of industrial effluents, either in separate systems or in combined systems.
This technical report:
- explains in more detail the process of testing for the performance tests;
- explains in more detail the benefits of high alumina cement lining;
- explains in more detail the definitions of the different types/levels of attestation to enable customers to ensure their requirements are fulfilled;
- explains in more detail the ways of certification of conformity with EN 598 for a reliable evaluation of the performance of products;
- explains in more detail CE marking and its relevance i.e. the CE mark is not a mark of conformity with a standard but only a self-declaration concerning the CPD essential requirements.
In order to make the use of this Technical Report easier, the clauses of this document refer to the corresponding clause numbers in EN 598.
- Technical report11 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of drains and sewers outside buildings:
- operating without pressure (gravity sewerage), or with positive or negative pressure (see Table 5);
- to be installed below or above ground;
- to convey surface water, domestic waste water and certain types of industrial effluents, either in separate systems or in combined systems.
This European Standard applies to pipes, fittings and accessories which are:
- manufactured with socketed, flanged or spigot ends;
- normally delivered externally and internally coated;
- suitable for continuous fluid temperatures between 0 °C excluding frost, and 45 °C for DN - 200 or 35 °C for
DN - 200, according to EN 476;
- not intended for use in areas subject to reaction to fire regulations.
NOTE 1 This does not preclude special arrangements for the products to be used at higher temperatures.
This European Standard covers pipes, fittings and accessories cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, of a size range extending from DN 80 to DN 2000 inclusive.
This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron pipes and fittings. It also gives performance requirements for all components including joints. Joint design and gasket shapes are outside the scope of this European Standard.
NOTE 2 In this European Standard, all pressures are relative pressures, expressed in bars (100 kPa = 1 bar).
- Standard66 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods applicable to factory applied cement mortar coatings for the external corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C, and for soil conditions according to Annex D.3 of EN 545:2006.
Special activities on site such as joint protection, tapping, clamping, etc. could affect the corrosion protection properties of the cement mortar coating. These operations should be covered in the laying instructions supplied by the manufacturers of pipes, clamps, house connection saddles, etc and any relevant users' procedures. Such instructions are not part of this European Standard.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard defines the requirements and test methods applicable to factory applied external polyurethane based coatings for heavy duty (Annex D.3 of EN 545:2002) corrosion protection of buried ductile iron pipes conforming to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
This standard does not cover ductile iron pipes protected with zinc with a finishing layer of polyurethane.
This standard does not cover special activities on site such as tapping, clamping, etc., which could affect the corrosion protection properties of the polyurethane coating. These operations should be covered in the laying instructions supplied by manufacturers of clamps, house connection saddles, etc. and any relevant user procedures.
- Standard19 pagesEnglish languagesale 10% offe-Library read for1 day
EN 545 specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of pipelines:
to convey water (e.g. potable water);
with or without pressure;
to be installed below or above ground.
In respect to potential adverse effects on the quality of water intended for human consumption, caused by the product covered by this standard:
this standard provides no information as to whether the product may be used without restriction in any of the member states of the EU or EFTA;
it should be noted that, while awaiting the adoption of verifiable European criteria, existing national regulations concerning the use and/or the characteristics of this product remain in force.
This technical report:
provides details on the current national regulations concerning the quality of water intended for human consumption;
explains in more detail the process of testing for the performance tests;
explains in more detail the definitions of the different types/levels of attestation to enable customers to ensure their requirements are fulfilled;
explains in more detail the ways of certification of conformity with EN 545 for a reliable evaluation of the performance of the products.
In order to make the use of this Technical Report easier, the clauses of this document refer to the corresponding clause numbers in EN 545.
The current national regulations concern the quality of water intended for human consumption.
A comprehensive potability regulation means:
regulatory obligation ( i.e. : decree, law….);
technical specifications;
tests methods to verify the compliance with the technical specifications;
directory of approved laboratories able to carry out these tests.
On October the 1st 2005, there is a national regulation in the following countries: Austria, France, Germany, Italy, Netherlands, Switzerland and United Kingdom.
- Technical report12 pagesEnglish languagesale 10% offe-Library read for1 day
This document defines the requirements and test methods applicable to factory applied cement mortar coatings for the external corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
NOTE Coatings according to this document are suitable for soils of all common corrosion loads and trenchless applications.
Special activities on site such as joint protection, tapping, clamping, etc. could affect the corrosion protection properties of the cement mortar coating. These operations should be covered in the laying instructions supplied by the manufacturers of pipes, clamps, house connection saddles, etc. and any relevant users' procedures. Such instructions are not part of this document.
- Draft17 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the products characteristics and associated test and assessment methods applicable to coated and lined ductile iron pipes, coated and lined fittings and joints which include (non-exhaustive list) coated and lined accessories such as collar, tees, saddles, bends, tapers, flanged socket.
Intended use: Gravity and pressure drains and sewers:
- operating without pressure, or with positive or negative pressure;
- installed below or above ground;
- for conveyance of surface water, wastewater in separate systems or in combined systems.
- Draft75 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to cast iron pipeline components used for the construction of discharge systems for buildings and of drains, normally as gravity systems. The range of nominal sizes extends from DN 40 to DN 600 inclusive. This standard specifies the requirements for the materials, dimensions and tolerances, mechanical properties, appearance, standard coatings and quality assurance for cast iron pipes, fittings and accessories. It also indicates performance requirements for all components, including joints.
- Draft62 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of pipelines: - to convey water (e. g. for drinking water pipelines, fire protection, snow guns, irrigation, hydroelectric, reused water pipelines, etc…) - with or without pressure ; - to be installed below or above ground. This standard is applicable to pipes, fittings and accessories which are : - manufactured with socketed, flanged or spigot ends; - normally delivered externally and internally coated ; - suitable for fluid temperatures between 0 °C and 50 °C, excluding frost. This standard covers pipes, fittings ast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints and accessories, in a size range extending from DN 40 to DN 2 000, inclusive. This standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron pipes and fittings. It also gives performance requirements for all components including joints. Joint design and gasket shapes are outside the scope of this standard. In addition reference is made to the performance requirements of couplings, flange adaptors and saddles manufactured only for use with ductile iron pipes and fittings NOTE In this standard, all pressures are relative pressures, expressed in bars (100 kPa = 1 bar).
- Draft90 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder or liquid two-pack) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
- conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
- conveying waste water at operating temperature up to 45 °C excluding frost; or
- conveying gas at operating temperature up to 50 °C;
- suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in EN 545:2010, D.2.3.
- Draft4 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies the requirements and associated test methods applicable to wide tolerance ductile iron couplings and wide tolerance flange adaptors intended for use with pipe components made from a number of pipe materials (ductile iron, grey iron, PE, PVC-U, steel, fibre-cement), for providing a leak tight seal over a wide range of pipe external diameters :
- to convey water (e.g. potable water) ;
- with or without pressure ;
- to be installed below or above ground, inside or outside buildings.
This standard is not intended to cover sewerage or gas applications, where other requirements may be necessary.
This standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron products.
This standard covers ductile iron products cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, in a size range extending from DN 40 to DN 600, for an allowable operating pressure (PFA) up to 16 bar, for fluid temperatures between 0 °C and 25 °C excluding frost. For higher temperatures, up to 50 °C, additional type testing should be carried out.
It also gives performance requirements and associated test methods for restrained and non-restrained flexible joints. Joint design and gasket shapes are outside the scope of this standard.
NOTE 1 PFA may be limited depending on pipe materials effectively connected.
NOTE 2 In this standard, all pressures are relative gauge pressures, expressed in bars (100 kPa = 1 bar).
NOTE 3 EN 545 gives the specifications for the ductile iron fittings to be used with ductile iron pipes.
NOTE 4 EN 12842 gives the specifications for the ductile iron fittings to be used with PVC-U and PE pipes.
- Standard28 pagesEnglish languagesale 10% offe-Library read for1 day
TC - Corrections or new text inserted in 3.13, 4.1.3, 4.6.3, 5.7.3.3, D.2, Table D.1, Annexes G and H and various places of Annex ZA
- Corrigendum7 pagesEnglish languagesale 10% offe-Library read for1 day
For reasons of conformity with the rules for hENs and Mandate M/131 'Pipes, tanks and ancillaries not in contact with water intended for human consumption', EN 877:1999 has been amended by extension with the Annex ZA (see Resolution CEN/BT 113/1994 and CEN/BT 63/1996) and a modification of the Annex D for the evaluation of conformity. This amendment is described in the following pages.
In addition, the amendment of the following parts of EN 877:1999 became necessary.
- Amendment23 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to cast iron pipeline components used for the construction of discharge systems for buildings and of drains, normally as gravity systems. The range of nominal sizes extends from DN 40 to DN 600 inclusive. This standard specifies the requirements for the materials, dimensions and tolerances, mechanical properties, appearance, standard coatings and quality assurance for cast iron pipes, fittings and accessories. It also indicates performance requirements for all components, including joints.
- Standard49 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods applicable to factory applied extruded polyethylene coatings for the external corrosion protection of ductile iron pipes conforming to EN 545, EN 598 and EN 969 for use at operating temperatures up to 50 °C.
This European Standard does not cover ductile iron pipes protected with thin PE sleeve. Special works at site like drilling, tapping etc. may influence the corrosion protection properties. Those job steps shall be included in the instructions of pipe saddle and accessory manufacturers and all other essential installation instructions. These instructions are not part of this European Standard.
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder or liquid two-pack) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
- conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
- conveying waste water at operating temperature up to 45 °C excluding frost; or
- conveying gas at operating temperature up to 50 °C;
- suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterized in EN 545:2010, D.2.3.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods applicable to factory applied internal polyurethane high duty corrosion protection of buried ductile iron pipes and fittings conforming to EN 545, EN 598 and EN 969 for use at permanent operating temperatures up to 45 °C.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the requirements and test methods for factory applied epoxy coatings (fusion bonded powder (P) or liquid two pack (L)) used for the corrosion protection of ductile iron fittings and accessories conforming to EN 545, EN 598, EN 969, EN 12842, EN 14525, for:
conveying water (e.g. potable water) at operating temperature up to 50 °C excluding frost; or
conveying waste water at operating temperature up to 45 °C excluding frost; or
conveying gas at operating temperature up to 50 °C;
suitable for external environments, i.e. soils, waters and atmospheres of all common corrosion loads, characterised in annex D3 of EN 545:2002.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron fittings and their joints to be used with poly(vinyl chloride) (PVC-U) pipes for polyethylene (PE) pipes, in conformity with prEN 1452-1 to 7 and prEN 12201-1 to 7 respectively, for the construction of pipelines: - to convey water (e.g. potable water); - with or without pressure; - to be installed below or above ground, inside or outside buildings.
- Standard38 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of pipelines:
to convey water (e. g. potable water);
with or without pressure;
to be installed below or above ground.
This standard is applicable to pipes, fittings and accessories which are:
manufactured with socketed, flanged or spigot ends;
normally delivered externally and internally coated;
suitable for fluid temperatures between 0 °C and 50 °C, excluding frost.
This standard covers pipes, fittings and accessories cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints, in a size range extending from DN 40 to DN 2 000, inclusive.
This standard specifies requirements for materials, dimensions and tolerances, mechanical properties and standard coatings of ductile iron pipes and fittings. It also gives performance requirements for all components including joints. Joint design and gasket shapes are outside the scope of this standard.
NOTE In this standard, all pressures are relative pressures, expressed in bars (100 kPa = 1 bar).
- Standard87 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes,
fittings, accessories and their joints for the construction of drains and sewers outside buildings:
- operating without pressure (gravity sewerage), or with positive or negative pressure (see Table 5);
- to be installed below or above ground;
- to convey surface water, domestic waste water and certain types of industrial effluents, either in separate systems
or in combined systems.
This European Standard applies to pipes, fittings and accessories which are:
- manufactured with socketed, flanged or spigot ends;
- normally delivered externally and internally coated;
- suitable for continuous fluid temperatures between 0 °C excluding frost, and 45 °C for DN ≤ 200 or 35 °C for
DN > 200, according to EN 476;
- not intended for use in areas subject to reaction to fire regulations.
NOTE 1 This does not preclude special arrangements for the products to be used at higher temperatures.
This European Standard covers pipes, fittings and accessories cast by any type of foundry process or manufactured
by fabrication of cast components, as well as corresponding joints, of a size range extending from DN 80 to DN 2000
inclusive.
This European Standard specifies requirements for materials, dimensions and tolerances, mechanical properties and
standard coatings of ductile iron pipes and fittings. It also gives performance requirements for all components
including joints. Joint design and gasket shapes are outside the scope of this European Standard.
NOTE 2 In this European Standard, all pressures are relative pressures, expressed in bars (100 kPa = 1 bar).
- Standard66 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment3 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for theconstruction of pipelines: - to convey air or combustible gases (e.g. natural gas or town gas) at pressures up to 16 bar; - to be installed below or above ground. Note 1: A combustible gas is a gas or any fuel that is in a gaseous state at a temperature of 15°C at a pressure of 1 bar.
- Standard61 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of drains and sewers outside buildings: - operating without pressure, or with positive or negative pressure; - installed below or above ground; - for conveyance of surface water, domestic waste water and certain types of industrial effluents, either in separate systems or in mixed systems.
- Standard57 pagesEnglish languagesale 10% offe-Library read for1 day
TC - Updated calculation in Annex G.2
- Corrigendum4 pagesEnglish, French and German languagesale 10% offe-Library read for1 day
TC forecasts updated : delay caused by some technical discussions withing WG (TC forecasts updating exercise.sj 00-10-17)++
- Standard86 pagesEnglish languagesale 10% offe-Library read for1 day
This European standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for theconstruction of pipelines: - to convey water (e.g. potable water), - with or without pressure, - to be installed below or above ground.
- Standard95 pagesEnglish languagesale 10% offe-Library read for1 day