33.100.99 - Other aspects related to EMC
Other aspects related to EMC
Weitere Aspekte der EMV
Autres aspects lies a la compatibilite electromagnetique
Drugi vidiki v zvezi z EMC
General Information
- Amendment5 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment5 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard6 pagesEnglish and French language
sale 15% off
- Corrigendum5 pagesEnglish language
sale 10% off- e-Library read for1 day
This International Standard contains limits and procedures for the measurement of radio
disturbances in the frequency range of 150 kHz to 2 500 MHz. The standard applies to any
electronic/electrical component intended for use in vehicles, trailers and devices. Refer to
International Telecommunications Union (ITU) publications for details of frequency
allocations. The limits are intended to provide protection for receivers installed in a vehicle
from disturbances produced by components/modul...view more
- Standard155 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC corrigendum
- Corrigendum4 pagesEnglish and French language
sale 10% off- e-Library read for1 day
IEC 61000-4-23:2016(E) provides a protective devices test method for HEMP and other radiated disturbances. It is primarily intended for HEMP testing but can be applied to other externally generated radiated disturbances where appropriate. It provides a brief description of the most important concepts for testing of shielding elements. For each test, the following basic information is provided:
- theoretical foundation of the test (the test concepts);
- test set-up including outside-to-in and i...view more
- Standard104 pagesEnglish language
sale 15% off
IEC 61000-1-2:2016 establishes a methodology for the achievement of functional safety only with regard to electromagnetic phenomena. This methodology includes the implication it has on equipment used in such systems and installations. It has the status of a basic safety publication in accordance with IEC Guide 104. This first edition cancels and replaces the second edition of IEC TS 61000-1-2 published in 2008. This edition constitutes a technical revision.
- Standard76 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 61000-1-2:2016 establishes a methodology for the achievement of functional safety only with regard to electromagnetic phenomena. This methodology includes the implication it has on equipment used in such systems and installations. This first edition cancels and replaces the second edition of IEC TS 61000-1-2 published in 2008. This edition constitutes a technical revision.
- Standard149 pagesEnglish and French language
sale 15% off
NEW! IEC 61000-4-30:2015 is available as IEC Standards+ 61000-4-30:2015 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-4-30:201 5 defines the methods for measurement and interpretation of results for power quality parameters in a.c. power supply systems with a declared fundamental frequency of 50 Hz or 60 Hz. Measurement methods are described for each relevant parameter in terms that give...view more
- Standard73 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard – translation71 pagesSlovenian language
sale 10% off- e-Library read for1 day
IEC 61000-4-30:2015 is available as IEC 61000-4-30:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61000-4-30:201 5 defines the methods for measurement and interpretation of results for power quality parameters in a.c. power supply systems with a declared fundamental frequency of 50 Hz or 60 Hz. Measurement methods are described for each relevant parameter in terms that give reliable...view more
- Standard146 pagesEnglish and French language
sale 15% off
IEC 61000-4-25:2001+A1:2012 describe immunity test levels and related test methods for electrical and electronic equipment and systems exposed to high-altitude electromagnetic pulse (HEMP) environments. Specifications for test equipment and instrumentation test set-up, test procedures, pass/fail criteria, and test documentation requirements are also defined by this standard. These tests are intended to demonstrate the immunity of electrical and electronic equipment when subjected to HEMP radiate...view more
- Standard96 pagesEnglish and French language
sale 15% off
2012-03-14: Publication editing allocated to svandriessche@cencenelec.eu
- Amendment10 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard12 pagesEnglish and French language
sale 15% off
This International standard specifies methods to measure the radio interference suppression
characteristics of passive EMC filtering devices used in power and signal lines, and in other
circuits.
The defined methods may also be applied to combinations of over-voltage protection devices
and EMC filtering devices.
The measurement method covers the frequency range from 9 kHz to several GHz depending
on the device and test circuit.
NOTE Measurement methods in this standard may be applied up t...view more
- Standard69 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC/TS 61000-1-2:2008(E) establishes a methodology for the achievement of functional safety only with regard to electromagnetic phenomena of electrical and electronic systems and installations, as installed and used under operational conditions. This methodology includes the implication it has on equipment used in such systems and installations. IEC/TS 61000-1-2:2008:
a) applies to safety-related systems incorporating electrical/electronic/programmable electronic equipment;
b) consid...view more
- Technical specification84 pagesEnglish language
sale 10% off- e-Library read for1 day
Applies to the generation of electromagnetic energy from sound and television receivers for the reception of broadcast and similar transmissions and from associated equipment. Describes the methods of measurement applicable to sound and television receivers or associated equipment and specifies limits for the control of disturbance from such equipment. The frequency range covered extends from 9 kHz to 400 GHz.
- Addendum2 pagesEnglish language
sale 10% off- e-Library read for1 day
superseded by EN 55013:2013
- Amendment5 pagesEnglish language
sale 10% off- e-Library read for1 day
Applies to optical fibre amplifiers (OFAs) using active fibres, containing rare-earth dopants, presently commercially available. The object of this standard is to establish uniform requirements for accurate and reliable measurements, by means of the electrical spectrum analyzer test method, of the following parameters: a) small-signal gain; b) reverse small-signal gain; c) maximum small-signal gain; d) maximum small-signal gain wavelength; e) maximum small-signal gain variation with temperature;...view more
- Standard22 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of IEC 61290 applies to all commercially available optical amplifiers (OAs) and optically amplified sub-systems. It applies to OAs using optically pumped fibres (OFAs based on either rare-earth doped fibres or on the Raman effect), semiconductors (SOAs), and waveguides (POWAs).
- Standard22 pagesEnglish language
sale 10% off- e-Library read for1 day