Standard Specification for Dehumidifier, Shipboard, Mechanically Refrigerated, Self-Contained

ABSTRACT
This specification covers the performance requirements and corresponding test procedures for self-contained shipboard dehumidifiers that use hermetic refrigerant motor-compressors. The components of the dehumidifier, including the motor-compressor, condensing unit, dehumidifying coil, air-circulating fan, and accessories, shall all be enclosed within a metal cabinet. Dehumidifiers shall be evaluated by design capacity test, overload test, inclination test, and corrosion resistance test, and should operate satisfactorily as specified. Requirements for design documentation, schematic drawings, and manufacturer's manual are also considered.
SCOPE
1.1 This specification covers self-contained dehumidifiers using hermetic refrigerant motor-compressors.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
The following safety hazards caveat pertains only to the test methods portion, Section , of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Apr-2004
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1075-97(2004) - Standard Specification for Dehumidifier, Shipboard, Mechanically Refrigerated, Self-Contained
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: F 1075 – 97 (Reapproved 2004)
Standard Specification for
Dehumidifier, Shipboard, Mechanically Refrigerated, Self-
Contained
This standard is issued under the fixed designation F 1075; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 2.4 UL Standards:
UL 474 Dehumidifiers
1.1 This specification covers self-contained dehumidifiers
UL 984 Hermetic Refrigerant Motor—Compressors
using hermetic refrigerant motor-compressors.
2.5 Military Documents:
1.2 The values stated in inch-pound units are to be regarded
MIL-S-901 Specification Requirements for Shock Tests,
as the standard. The values given in parentheses are for
High Impact (H.I.); Shipboard Machinery, Equipment,
information only.
and Systems
1.3 The following safety hazards caveat pertains only to the
MIL-STD-167-1 Mechanical Vibrations of Shipboard
test methods portion, Section 11, of this specification: This
Equipment, (Type I—Environmental and Type II—
standard does not purport to address all of the safety concerns,
Internally Excited)
if any, associated with its use. It is the responsibility of the user
MIL-D-19947 Specification for Dehumidifier, Space, Me-
of this standard to establish appropriate safety and health
chanically Refrigerated, Self-Contained, Naval Shipboard
practices and determine the applicability of regulatory limita-
tions prior to use.
3. Ordering Information
2. Referenced Documents 3.1 Ordersforproductsunderthisspecificationshallinclude
the following information, as necessary, to describe adequately
2.1 ASTM Standards:
the desired product:
B 117 Practice for Operating Salt Spray (Fog) Apparatus
3.1.1 Title, ASTM designation, and year of issue,
B 280 Specification for Seamless Copper Tube for Air
3.1.2 Quantity (number of dehumidifiers),
Conditioning and Refrigeration Field Service
3.1.3 Certification if required, and
D 1654 Test Method for Evaluation of Painted or Coated
3.1.4 Additions to the specification and supplementary re-
Specimens Subjected to Corrosive Environments
quirements, if required.
D 2247 PracticeforTestingWaterResistanceofCoatingsin
100 % Relative Humidity
4. Materials and Manufacture
2.2 ASHRAE Standard:
4.1 In addition to the requirements cited in this specifica-
ASHRAE—15 Safety Code for Mechanical Refrigeration
4 tion, the dehumidifiers covered by this specification shall be
2.3 Offıcial Classification Standard:
designed, constructed, assembled, and tested to comply with
Uniform Freight Classification Ratings, Rules, and Regula-
UL 474, UL 984, and ASHRAE Standard 15. In the event of
tions
differences between any of the requirements of this specifica-
tion and those of other referenced documents, the requirements
of this specification shall govern. The manufacturer shall
certify compliance with the above standards for equipment
This specification is under the jurisdiction of ASTM Committee F25 on Ships
furnished and shall be cited in the ULElectricalAppliance and
and Marine Technology and is the direct responsibility of Subcommittee F25.11 on
Machinery and Piping Systems. Utilization Equipment product directories.
Current edition approved May 1, 2004. Published May 2004. Originally
4.2 The dehumidifier shall consist of a motor-compressor,
approved in 1987. Last previous edition approved in 1997 as F 1075 – 97.
condensing unit, dehumidifying coil, air-circulating fan, and
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
accessories, all enclosed within a metal cabinet.The dehumidi-
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
fier shall be complete, self-contained with the refrigeration
the ASTM website.
Available from American Society of Heating, Refrigerating, and Air-
Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA
Available from Underwriter’s Laboratories Inc., 333 Pfingsten Rd., North-
30329. brook, IL 60062.
4 6
Available from Uniform ClassificationAgent, Tariff Publication Officer, Room Available from Superintendent of Documents, U.S. Government Printing
1106, 222 South Riverside Plaza, Chicago, IL 60606. Office, Washington, DC 20402.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
F 1075 – 97 (2004)
equipment dehydrated, and charged with the necessary operat- 5.3 Theequipmentshalloperatesatisfactorilywheninclined
ing quantity of refrigerant and oil. Each unit shall be ready for at an angle of 15° on each side of the vertical, in each of two
operation after removal of shipping protection, opening of vertical planes at right angles to each other.
valves where provided, and connection to electric power.
4.3 The motor-compressor shall be of the hermetic type and
6. Other Requirements
shall consist of a compressor and motor enclosed in a gastight
6.1 Design Documentation—A master drawing of a built
shell. The hermetic compressor unit shall conform to UL 984
configuration shall be provided for each of the following:
and shall be at least ⁄6 hp. Equipment shall operate on 115-V,
6.1.1 Complete dehumidifier,
single-phase, 60-cycle alternating current. The unit shall be
6.1.2 Motor compressor,
protected against overload by a thermal protector built into the
6.1.3 Condenser, and
motor. The thermal protection shall be either the manual or
6.1.4 Fan and cooling coil.
automatic reset type.
6.1.5 Each master drawing shall show outline, mounting,
4.4 Piping necessary for the satisfactory operation of the
attachment, and connection dimensions, including methods
equipment shall be provided by the manufacturer. Tubing shall
and sizes of fastenings and clearances for installation and
be made of copper in accordance with Specification B 280.
servicing, plus supplementary data as necessary to permit
Pipingconnectionsshallbearrangedinsuchamannersoasnot
installation without suppliers assistance. The drawing shall
to impair the vibration-isolation properties of absorption-type
illustrate design, construction, operation (or function), and
mounts, where such mounts are provided. Piping shall be
identity of parts. Where acceptance tests are required, the tests
securely supported to minimize strain and vibration. Piping
shall be identified, and approval authority and date shall be
connections shall not be made of soft solder.
notedonthedrawing.Subassemblydrawingsshallbeprovided
4.5 Materials used in the manufacture of the equipment
to supplement master drawings where desirable.
shall be corrosion-resistant or treated to resist corrosion. The
6.2 Schematic Drawings:
method of manufacture shall not impair physical, structural, or
corrosion-resistant properties of the components. Materials,
6.2.1 Schematic drawings shall be provided that include all
coatings, and paint systems shall satisfactorily pass the appli- mechanical, piping and electrical circuits, and connections.
cablesaltsprayandhumiditytestspecifiedinthisspecification.
6.2.2 All symbols used for equipment components or parts
4.6 Bolts, nuts, studs, pins, screws, and such other fasten-
shall be given a piece number and identified in the list of
ings or fittings shall be of a corrosion-resisting material, or of
materials with the following information:
a material treated in a manner to render it adequately resistant
6.2.2.1 Piece number,
to corrosion. Screws exposed in final assembly shall be
6.2.2.2 Quantity required,
corrosion-resisting material.
6.2.2.3 Descriptive name,
4.7 Similar parts, including repair parts, or corresponding
6.2.2.4 Manufacturer,
apparatus furnished on the same contract or order, or built to
6.2.2.5 Manufacturer’s model or identifying number,
thesamedrawings,shallbestrictlyinterchangeablewithoutthe
6.2.2.6 Manufacturer’s drawing number, and
necessity of further machining or hand fitting of any kind.
6.2.2.7 Weight.
4.8 A plastic or other chemically inert container shall be
provided for collecting the condensate. The container shall be 6.3 Manuals—Manuals shall be typed in accordance with
the manufacturer’s commercial practice. Photo views of the
of a size and configuration that will fit within the cabinet
equipment shall be included as part of the general description.
enclosure. The container shall be provided with baffles to
A section shall be provided containing reduced copies of all
prevent the overflow or spilling of water and shall be readily
drawings required to amplify or illustrate the text including
removable from the dehumidifier cabinet. A male fitting shall
diagram and assembly drawings.
be provided from the container for connection of a 0.375-in.
(10-mm)insidediameterflexiblerubbertubingfordrainingthe
7. Workmanship, Finish, and Appearance
condensate (wall thickness 0.125 in. (3 mm)). The rubber
tubing will not be required to be furnished by the contractor.
7.1 All materials forming a part of the finished product shall
4.9 Provision shall be made in the frame to permit securing
be new and suitable for the purpose intended. The materials
the cabinet to any appropriate surface.
shall be free from any defects that might affect the serviceabil-
4.10 Identification plates shall be of a nonferrous metal or
ity or appearance of the finished product.
corrosion-resisting steel and shall conform to UL 474.
7.2 Seal caps in the refrigerant system shall be provided
with a gasket and shall be tight against any leaks.
5. Performance Requirements
7.3 Bolts, nuts, and screws shall be tight and equipment and
5.1 The unit shall be capable of condensing at least 1.8 gal
parts shall be properly fastened and secured.
(7L)ofwaterin24hatanambienttemperatureof90°F(
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.