Standard Practice for Specifying Color by the Munsell System

SIGNIFICANCE AND USE
This practice is used by artists, designers, scientists, engineers, and government regulators, to specify an existing or desired color. It is used in the natural sciences to record the colors of specimens, or identify specimens, such as human complexion, flowers, foliage, soils, and minerals. It is used to specify colors for commerce and for control of color-production processes, when instrumental color measurement is not economical. The Munsell system is widely used for color tolerancing, even when instrumentation is employed (see Practice D 3134). It is common practice to have color chips made to illustrate an aim color and the just tolerable deviations from that color in hue, value, and chroma, such a set of chips being called a Color Tolerance Set. A color tolerance set exhibits the aim color and color tolerances so that everyone involved in the selection, production, and acceptance of the color can directly perceive the intent of the specification, before bidding to supply the color or starting production. A color tolerance set may be measured to establish instrumental tolerances. Without extensive experience, it may be impossible to visualize the meaning of numbers resulting from color measurement, but by this practice, the numbers can be translated to the Munsell color-order system, which is exemplified by colored chips for visual examination. This color-order system is the basis of the ISCC-NBS Method of Designating Colors and a Dictionary of Color Names, as well as the Universal Color Language, which associates color names, in the English language, with Munsell notations (3).
SCOPE
1.1 This practice provides a means of specifying the colors of objects in terms of the Munsell color order system, a system based on the color-perception attributes hue, lightness, and chroma. The practice is limited to opaque objects, such as painted surfaces viewed in daylight by an observer having normal color vision. This practice provides a simple visual method as an alternative to the more precise and more complex method based on spectrophotometry and the CIE system (see Practices E 308 and E 1164). Provision is made for conversion of CIE data to Munsell notation.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Jun-2007
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Effective Date
01-Jul-2007

Buy Standard

Standard
ASTM D1535-07 - Standard Practice for Specifying Color by the Munsell System
English language
44 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 1535 – 07
Standard Practice for
1
Specifying Color by the Munsell System
This standard is issued under the fixed designation D 1535; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope 3.2 Definitions:
3.2.1 Munsell notation, n—(1) the Munsell hue, value, and
1.1 This practice provides a means of specifying the colors
chroma assigned to the color of a specimen by visually
of objects in terms of the Munsell color order system, a system
comparing the specimen to the chips in the Munsell Book of
based on the color-perception attributes hue, lightness, and
3
Color; (2) a notation in the Munsell color system, derived
chroma. The practice is limited to opaque objects, such as
from luminous reflectance factor Y and chromaticity coordi-
painted surfaces viewed in daylight by an observer having
nates x and y, in the CIE system for standard illuminant C,by
normal color vision. This practice provides a simple visual
the use of scales defined by the Optical Society of America
methodasanalternativetothemorepreciseandmorecomplex
4
Subcommittee on the Spacing of the Munsell Colors (1).
method based on spectrophotometry and the CIE system (see
3.2.1.1 Discussion—The Munsell notation is written as a
Practices E 308 and E 1164). Provision is made for conversion
combination of letters and numbers by which the color of an
of CIE data to Munsell notation.
opaque object may be specified with respect to Munsell hue H,
1.2 This standard does not purport to address all of the
Munsell value V, and Munsell chroma C, written in the form H
safety concerns, if any, associated with its use. It is the
V/C.
responsibility of the user of this standard to establish appro-
3.2.2 hue, n—the attribute of color perception by means of
priate safety and health practices and determine the applica-
which a color is judged to be red, orange, yellow, green, blue,
bility of regulatory limitations prior to use.
purple, or intermediate between adjacent pairs of these, con-
2. Referenced Documents sidered in a closed ring (red and purple being an adjacent pair).
2
3.2.3 Munsell hue, n—an attribute of color used in the
2.1 ASTM Standards:
Munsell color system to indicate the hue of a specimen viewed
D 1729 Practice for Visual Appraisal of Colors and Color
in daylight.
Differences of Diffusely-Illuminated Opaque Materials
3.2.3.1 Discussion—Two systems of designating Munsell
D 3134 Practice for Establishing Color and Gloss Toler-
hue are shown in Fig. 1, a letter-number system and an
ances
all-number system. The two systems are equivalent, but the
E 284 Terminology of Appearance
letter-number system is preferred, because it requires no prior
E 308 Practice for Computing the Colors of Objects by
knowledge or memory of the correspondence of numbers to
Using the CIE System
hues. The hue circle is graduated in steps judged visually to be
E 1164 Practice for Obtaining Spectrometric Data for
approximately equal.
Object-Color Evaluation
3.2.4 lightness, n—the attribute of color perception by
3. Terminology
which a non-self-luminous body is judged to reflect more or
less light.
3.1 Terms and definitions in Terminology E 284 are appli-
3.2.5 Munsell value, n—an attribute of color used in the
cable to this practice.
Munsell color system to indicate the lightness of a specimen
viewed in daylight, on a scale extending from 0 for ideal black
1
This practice is under the jurisdiction of ASTM Committee E12 on Color and
to 10 for ideal white, in steps that are visually approximately
Appearance and is the direct responsibility of Subcommittee E12.07 on Color Order
equal in magnitude.
Systems.
Current edition approved July 1, 2007. Published July 2007. Originally approved
in 1958. Last previous edition approved in 2006 as D 1535 – 06.
2 3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available from GretagMacbeth, 617 Little Britain Road, New Windsor, NY
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM 12553-6148.
4
Standards volume information, refer to the standard’s Document Summary page on The boldface numbers in parentheses refer to a list of references at the end of
the ASTM website. this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
D1535–07
3.2.5.1 Discussion—Achromatic or neutral colors are des- color tolerance set may be measured to establish instrumental
ignated N followed
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.