Standard Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants

SCOPE
1.1 This specification covers joints for precast concrete pipe and box, and other sections using preformed flexible joint sealants for use in storm sewers and culverts which are not intended to operate under internal pressure, or are not subject to infiltration or exfiltration limits. Joint material used in horizontal applications is intended to prevent the flow of solids through the joint.
1.2 For precast concrete manhole sections and other vertical structures, which may be operated with internal or external pressure, infiltration or exfiltration limits may be specified. Joints in vertical structures covered by this specification are intended mainly to prevent the flow of solids or fluids through the joint.
1.3 This specification is to be used with pipe and structures conforming in all respects to Specifications C14, C76, C478, C506, C507, C655, C789, C850 and C985, provided that if there is a conflict in permissible variations in dimensions, the requirements of this specification shall govern.
1.4 This specification is the companion to SI specification C990M; therefore, no SI equivalents are shown in this specification.  
1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note 1—This specification covers the material and performance of the joint and sealant only. Infiltration and exfiltration quantities for installed sections are dependent on factors other than the joints which must be covered by other specifications and suitable testing of the installed pipeline.

General Information

Status
Historical
Publication Date
09-Aug-2001
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C990-01a - Standard Specification for Joints for Concrete Pipe, Manholes, and Precast Box Sections Using Preformed Flexible Joint Sealants
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 990 – 01a
Standard Specification for
Joints for Concrete Pipe, Manholes, and Precast Box
1
Sections Using Preformed Flexible Joint Sealants
This standard is issued under the fixed designation C 990; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope C 14 Specification for Concrete Sewer, Storm Drain, and
2
Culvert Pipe
1.1 This specification covers joints for precast concrete pipe
C 76 Specification for Reinforced Concrete Culvert, Storm
and box, and other sections using preformed flexible joint
2
Drain, and Sewer Pipe
sealants for use in storm sewers and culverts which are not
C 478 Specification for Precast Reinforced Concrete Man-
intended to operate under internal pressure, or are not subject
2
hole Sections
to infiltration or exfiltration limits. Joint material used in
C 506 Specification for Reinforced Concrete Arch Culvert,
horizontal applications is intended to prevent the flow of solids
2
Storm Drain, and Sewer Pipe
through the joint.
C 507 Specification for Reinforced Concrete Elliptical Cul-
1.2 For precast concrete manhole sections and other vertical
2
vert, Storm Drain, and Sewer Pipe
structures, which are subject to internal or external pressure,
C 655 Specification for Reinforced Concrete D-Load Cul-
infiltration or exfiltration limits are not prohibited from being
2
vert, Storm Drain, and Sewer Pipe
specified. Joints in vertical structures covered by this specifi-
C 765 Test Method for Low-Temperature Flexibility of
cation are intended mainly to prevent the flow of solids or
3
Preformed Tape Sealants
fluids through the joint.
C 766 Test Method for Adhesion After Impact of Preformed
1.3 This specification is to be used with pipe and structures
3
Tape Sealants
conforming in all respects to Specifications C 14, C 76, C 478,
C 822 Terminology Relating to Concrete Pipe and Related
C 506, C 507, C 655, C 985, and C 1433, provided that if there
2
Products
is a conflict in permissible variations in dimensions, the
C 969 Practice for Infiltration and Exfiltration Acceptance
requirements of this specification shall govern.
2
Testing of Installed Precast Concrete Pipe Sewer Lines
1.4 This specification is the companion to SI specification C
C 972 Test Method for Compression—Recovery of Tape
990M; therefore, no SI equivalents are shown in this specifi-
3
Sealant
cation.
C 985 Specification for Nonreinforced Concrete Specified
1.5 This standard does not purport to address all of the
2
Strength Culvert, Storm Drain, and Sewer Pipe
safety problems, if any, associated with its use. It is the
C 1433 Specification for Precast Reinforced Concrete Box
responsibility of the user of this standard to establish appro-
2
Sections for Culverts, Storm Drains, and Sewers
priate safety and health practices and determine the applica-
4
D 4 Test Method for Bitumen Content
bility of regulatory limitations prior to use.
D 6 Test Method for Loss on Heating of Oil and Asphaltic
NOTE 1—This specification covers the material and performance of the 4
Compounds
joint and sealant only. Infiltration and exfiltration quantities for installed
D 36 Test Method for Softening Point of Bitumen (Ring-
sections are dependent on factors other than the joints which must be
4
and-Ball Apparatus)
covered by other specifications and suitable testing of the installed
D 71 Test Method for Relative Density of Solid Pitch and
pipeline.
4
Asphalt (Displacement Method)
2. Referenced Documents
D 92 Test Method for Flash Fire Points by Cleveland Open
4
Cup
2.1 ASTM Standards:
5
D 113 Test Method for Ductility of Bituminous Materials
1
This specification is under the jurisdiction of ASTM Committee C13 on
2
Annual Book of ASTM Standards, Vol 04.05.
Concrete Pipe and is the direct responsibility of Subcommittee C13.08 on Rubber
3
Annual Book of ASTM Standards, Vol 04.07.
Gaskets.
4
Annual Book of ASTM Standards, Vol 04.04.
Current edition approved Aug. 10, 2001. Published October 2001. Originally
5
Annual Book of ASTM Standards, Vol 04.03.
published as C 990–91. Last previous edition C 990–01.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
C 990
D 217 Test Method for Cone Penetration of Lubricating
Bitumen (hydrocarbon blends), % by weight 50 % min
6
Ash-Inert Mineral Matter, % by weight 30 % min
Grease
Volatile Matter, % by weight 3 % max
6
D 482 Test Method fo
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.