ASTM F1070-87(2012)
(Specification)Standard Specification for Doors, Non-Tight, for Marine Use
Standard Specification for Doors, Non-Tight, for Marine Use
ABSTRACT
This specification covers the dimensional and mechanical requirements as well as the construction of steel, aluminum, and glass-reinforced plastic (GRP) non-tight, personnel doors and dutch doors for marine use. The door assembly shall be manufactured free of sharp and rugged edges, and the components shall be pretreated and primed as follows: steel doors and components shall be coated with inorganic zinc-rich primer before assembly, while aluminum doors and components shall be coated with wash primer followed by lead-free, chromate-free, anticorrosion prime coating. On the other hand, GRP doors and components shall be painted a "haze gray" color after molding. Not covered by this specification are joiner, joiner dutch doors, and expanded metal doors.
SCOPE
1.1 This specification to be used in conjunction with Specification F1073, covers the principal dimensions and the mechanical requirements for manufacturing steel, aluminum, and glass-reinforced plastic non-tight, personnel doors and dutch doors, with the exception of joiner, joiner dutch doors, and expanded metal doors, for marine use.
1.2 The doors will be used in non-tight bulkheads.
1.3 When fire protection requirements are applicable to the location of these doors, then the use of aluminum and glass-reinforced plastic doors shall be unacceptable.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F1070 −87 (Reapproved 2012) An American National Standard
Standard Specification for
Doors, Non-Tight, for Marine Use
This standard is issued under the fixed designation F1070; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope MIL-R-21607 Resins, Polyester Low-Pressure Laminating,
Fire Retardant
1.1 This specification to be used in conjunction with Speci-
MIL-P-24441 Epoxy-Polyamide Paint
fication F1073, covers the principal dimensions and the me-
MIL-C-81706 Coating, Aluminum and Aluminum Alloys
chanical requirements for manufacturing steel, aluminum, and
TT-E-490 Enamel, Silicone Alkyd Copolymer, Semi-gloss,
glass-reinforced plastic non-tight, personnel doors and dutch
Exterior
doors, with the exception of joiner, joiner dutch doors, and
DoD-STD-2138 Metal Sprayed Coating Systems for Corro-
expanded metal doors, for marine use.
sion Protection
1.2 The doors will be used in non-tight bulkheads.
3. Ordering Information
1.3 When fire protection requirements are applicable to the
location of these doors, then the use of aluminum and glass-
3.1 Ordering for doors under this specification shall include
reinforced plastic doors shall be unacceptable.
the following:
3.1.1 Type of door and material (see Table 1 and Figs. 1-3),
1.4 The values stated in inch-pound units are to be regarded
3.1.2 Nominal and ASTM designations,
as the standard. The values given in parentheses are for
3.1.3 Quantity, hand of door (right hand or left hand, or
information only.
both), and
3.1.4 Optional items, such as fixed lights, door locks, to be
2. Referenced Documents
indicated.
2.1 ASTM Standards:
3.2 Inspection and acceptance of doors shall be agreed upon
A36/A36M Specification for Carbon Structural Steel
between the purchaser and the supplier.
A131/A131M Specification for Structural Steel for Ships
B209 Specification for Aluminum and Aluminum-Alloy
4. Materials and Manufacture
Sheet and Plate
F1073 Specification for Door Fittings, for Watertight
4.1 The materials and specifications shall be as given in
/Gastight /Airtight, Weathertight, and Non-Tight Doors,
Table 1.
for Marine Use
4.2 Glass-reinforced plastic (GRP) material of doors shall
2.2 ABS Standard:
meet the requirements of MIL-P-17549, Grade 1. In addition,
Rules for Building and Classing Steel Vessels
laminate must have the flammability limits equal to the
2.3 Military Standards: requirements for Grade 2, Class A of MIL-R-21607.
MIL-P-17549 Plastic Laminates, Fibrous Glass Reinforced,
5. Construction, Shape, and Dimensions
Marine Structural
5.1 The construction, shape, and clear opening dimensions
shall be as shown in Tables 1 and 2 and Figs. 1-3 and conform
This specification is under the jurisdiction of ASTM Committee F25 on Ships
to the following requirements:
and Marine Technology and is the direct responsibility of Subcommittee F25.03 on
5.1.1 A right-hand opening door shall be construed as one
Outfitting and Deck Machinery.
that opens towards you with hinges located on right side of
Current edition approved April 1, 2012. Published November 2012. Originally
approved in 1987. Last previous edition approved in 2004 as F1070 – 87 (2004).
door.Aleft-hand opening is similar but with hinges on the left.
DOI: 10.1520/F1070-87R12.
5.1.2 The size of the door opening and shape shall be as
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
given in Table 2.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
5.1.3 Figs. 1 and 2 show the right-hand opening, and in the
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
case of left-hand opening, the arrangement of fittings shall be
Available from American Bureau of Shipping, ABS Plaza, 16855 Northchase
reversed.
Dr., Houston, TX 77060.
5.1.4 The position of the grab handles shall be located on
AvailablefromStandardizationDocumentsOrderDesk,Bldg.4SectionD,700
Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS. the center of the height of both sides of the door; in the case of
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F1070−87 (2012)
TABLE 1 Standard Door Materials
Mild Steel Glass-Reinforced Plastic
Number Component Aluminum
(GRP)
1 door panel Specifications A36/A36M or Specification B209 MIL-P-17549, Grade 1
A131/A131M
2 stiffeners Specifications A36/A36M or Specification B209 integral
A131/A131M
TABLE 2 Door—Non-Tight
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.