EN 832:1998/AC:2002
(Corrigendum)Thermal performance of buildings - Calculation of energy use for heating - Residential buildings
Thermal performance of buildings - Calculation of energy use for heating - Residential buildings
TC - Editorial correction in D vers. (E. & F. vers. already corrected in May 2000)
Wärmetechnisches Verhalten von Gebäuden - Berechnung des Heizenergiebedarfs - Wohngebäude
Performance thermique des bâtiments - Calcul des besoins d'énergie pour le chauffage - Bâtiments résidentiels
Toplotne karakteristike stavb – Izračun potrebne energije za ogrevanje – Stanovanjske stavbe
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Wärmetechnisches Verhalten von Gebäuden - Berechnung des Heizenergiebedarfs - WohngebäudePerformance thermique des bâtiments - Calcul des besoins d'énergie pour le chauffage - Bâtiments résidentielsThermal performance of buildings - Calculation of energy use for heating - Residential buildings91.120.10Toplotna izol
...
This May Also Interest You
ISO 52016-1:2017 specifies calculation methods for the assessment of:
a) the (sensible) energy need for heating and cooling, based on hourly or monthly calculations;
b) the latent energy need for (de-)humidification, based on hourly or monthly calculations;
c) the internal temperature, based on hourly calculations;
d) the sensible heating and cooling load, based on hourly calculations;
e) the moisture and latent heat load for (de-)humidification, based on hourly calculations;
f) the design sensible heating or cooling load and design latent heat load using an hourly calculation interval;
g) the conditions of the supply air to provide the necessary humidification and dehumidification.
The calculation methods can be used for residential or non-residential buildings, or a part of it, referred to as "the building" or the "assessed object".
ISO 52016-1:2017 also contains specifications for the assessment of thermal zones in the building or in the part of a building. The calculations are performed per thermal zone. In the calculations, the thermal zones can be assumed to be thermally coupled or not.
The calculation methods have been developed for the calculation of the basic energy loads and needs, without interaction with specific technical building systems, and for the calculation of the system specific energy loads and needs, including the interaction with specific systems. The hourly calculation procedures can also be used as basis for calculations with more extensive system control options.
ISO 52016-1:2017 is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.
NOTE Table 1 in the Introduction shows the relative position of ISO 52016-1:2017 within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.
- Standard216 pagesEnglish languagesale 10% offe-Library read for×1 day
- Standard – translation227 pagesSlovenian languagesale 10% offe-Library read for×1 day
- 30-Oct-2017
- 30-Jan-2018
- 91.120.10
- 91.140.10
- 2010/31/EU
- M/480
- CEN/TC 89
This document covers standardization in the field of geological and environmental aspects, design, construction, operation, monitoring, maintenance and decommissioning of grouted borehole heat exchangers for uses in geothermal energy systems.
This document is only applicable for backfilled and grouted boreholes, it is not applicable for groundwater-filled boreholes.
Direct expansion and thermal syphon techniques are excluded from this document.
- Standard61 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft53 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Apr-2023
- 07.060
- 27.190
- 91.140.10
- CEN/TC 451
This document refers to EN 12098-3:2022, Energy performance of buildings - Controls for heating systems - Part 3: Control equipment for electrical heating systems - Modules M3-5,6,7,8.
It contains information to support the correct understanding, use and national adaption of EN 12098-3:2022.
This document does not contain any normative provisions.
- Technical report14 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft14 pagesEnglish languagesale 10% offe-Library read for×1 day
- 29-Nov-2022
- 91.140.10
- 97.120
- 2010/31/EU
- M/480
- CEN/TC 247
This document is applicable to electronic control equipment for heating systems with water as the heating medium and a supply water temperature up to 120 °C.
This control equipment controls the distribution and/or the generation of heat in relation to the outside temperature and time and other reference variables.
This document also is also applicable to controllers that contain an integrated optimum start or an optimum start-stop control function.
Safety requirements on heating systems remain unaffected by this document.
The dynamic behaviour of the valves and actuators are not covered in this document.
A multi-distribution and/or multi-generation system needs a coordinated solution to prevent undesired interaction and is not part of this document.
- Standard35 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft36 pagesEnglish languagesale 10% offe-Library read for×1 day
- 29-Nov-2022
- 91.140.10
- 97.120
- 2010/31/EU
- M/480
- CEN/TC 247
This document refers to EN 12098-1:2022, Energy performance of buildings - Controls for heating systems - Part 1: Control equipment for hot water heating systems - Modules M3-5, 6, 7, 8.
It contains information to support the correct understanding, use and national adaption of EN 12098-1:2022.
This document does not contain any normative provisions.
- Technical report20 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft19 pagesEnglish languagesale 10% offe-Library read for×1 day
- 29-Nov-2022
- 91.140.10
- 97.120
- 2010/31/EU
- M/480
- CEN/TC 247
1.1 General
This European Standard applies to heating boilers including safety devices up to a nominal heat output of 500 kW which are designed for the burning of solid fuels only and are operated according to the instructions of the boiler manufacturer.
This European Standard deals with significant hazards, hazardous situations and events relevant to heating boilers used as intended and under the conditions foreseen by the manufacturer (see Clause 4).
The boilers may operate under natural draught or forced draught. The stoking may work manually or automatically.
The boilers may operate under room sealed conditions in case of supervised under pressure in the combustion chamber.
The boilers may operate in condensing condition.
NOTE This European Standard deals with boilers which are both within and outside of the scope of the Machinery
Directive 2006/42/EC.
This European Standard contains requirements and test methods for safety, combustion quality, operating characteristics, marking and maintenance of heating boilers and secondary emission reduction appliances and efficiency improvement appliances. It also covers all external equipment that influences the safety systems (e.g. back burning safety device, integral fuel hopper).
This European Standard covers only boilers that include burners as a unit. The standard applies to the combination of a boiler body with a solid fuel burner according to EN 15270 as a unit only when the whole unit is tested in accordance with this European Standard.
Heating boilers in accordance with this European Standard are designed for central heating installations where the heat carrier is water and the maximum allowable temperature is 110 °C, and which can operate at a maximum allowable operating pressure of 6 bars. For heating boilers with a built-in or attached water heater (storage or continuous flow heater), this European Standard only applies to those parts of the water heater which are necessarily subject to the operating conditions of the heating boiler (heating part).
This European Standard does not apply to:
heating boilers and other heating appliances which are also designed for the direct heating of the place of installation;
cooking appliances;
the design and construction of external fuel storage and transportation devices prior to the safety devices of the boiler;
room sealed applications above a nominal heat output > 70 kW or operated with positive pressure in the combustion chamber or operated under natural draught;
This European Standard specifies the necessary terminology for solid fuel heating boilers, the control and safety related requirements, the design requirements, the technical heating requirements (taking into account the environmental requirements) and testing, as well as the marking requirements.
This European Standard is not applicable to heating boilers which are tested before the date of its publication as an EN (European Standard).
1.2 Fuels
These boilers may burn either fossil fuels, biogenic fuels or other fuels such as peat, as specified for their use by the boiler manufacturer, in accordance with the requirements of this European Standard.
Solid fuels included in this European Standard are categorised as follows.
1.2.1 Biogenic fuels
Biomass in a natural state, in the form of:
Adaptation to new fuels standards and consideration of new fuels standards in preparation.
A log wood with moisture content w ≤ 25 %, according to EN 14961-5;
B1 chipped wood (wood chipped by machine, usually up to a maximum length of 15 cm) with moisture content from w 15 % to w 35 %, according to EN 14961-4;
B2 chipped wood as under B1, except with moisture content w > 35 %;
C1 compressed wood (e.g. pellets without additives, made of wood and/or bark particles; natural binding agents such as molasses, vegetable paraffins and starch are permitted), pellets according to EN 14961-2;
(...)
- Standard103 pagesEnglish languagesale 10% offe-Library read for×1 day
This CEN Workshop Agreement (CWA) provides orientation for the management of building retrofitting projects based on enhanced shallow geothermal technologies.
This document provides guidelines for the classification of an integrated design team and the identification of the primary roles of actors among the whole project life-cycle. This document also provides a general workflow for building retrofitting projects based on enhanced shallow geothermal technologies, to be adapted or modified considering the specificities of each project requirements, and site characteristics, and stakeholder profiles involved in the process.
This CWA is not designed to support European legislative requirements or to address issues with significant health and safety implications. CEN and CENELEC are not accountable for its technical content or any possible conflict with national standards or legislation.
- Standardization document25 pagesEnglish languagesale 10% offe-Library read for×1 day
- Technical report25 pagesEnglish languagesale 10% offe-Library read for×1 day
- 25-Oct-2022
- 27.190
- 91.140.10
- CEN/WS GEOFIT
This document specifies the requirements and test methods, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as "boilers".
This document is intended to be used in conjunction with EN 15502-1:2021.
This document covers gas-fired central heating boilers from the types C1 up to C(11) and the types B2, B3 and B5:
NOTE 1 For further background information on appliance types see EN 1749:2020.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1 000 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which can give rise to condensation under certain circumstances;
f) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler"; if no declaration is given the boiler is to be considered a "standard boiler";
g) which are intended to be installed inside a building or in a partially protected place;
h) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit;
i) which are designed for either sealed water systems or for open water systems;
j) which are either modular boilers, or non-modular boilers.
k) which are from the types C(10) that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa, and C(11) that have condensing boiler modules that are equipped with a gas-air ratio control and that have a ∆pmax, saf(min) of 25 Pa.
NOTE 2 This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
aa) appliances above 1 000 kW;
ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021);
ac) appliances using flue dampers;
ad) appliances of the types B21, B31, B51, C21, C41, C51, C61, C71, C81, C(12) and C(13);
ae) C7 appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;
af) appliances incorporating flexible plastic flue liners;
ag) C(10) boilers:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ah) C(11) boilers that have boiler modules:
1) without a gas-air ratio control, or
2) which are non-condensing appliances, or
3) which have a maximum safety pressure difference at minimum heat input not equal to 25 Pa (∆pmax, saf(min));
ai) appliances intended to be connected to a flue having mechanical extraction;
aj) surface temperatures of external parts particular to children and elderly people;
ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas;
al) appliances equipped with an adaptive combustion control function (ACCF);
am) boilers intended to be installed in areas accessible to elderly people and children.
- Standard107 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft109 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard specifies the common requirements and test methods, as well as the classification, marking and energy labelling of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as “boilers”.
This European Standard is to be used in conjunction with the specific Parts 2 (Part 2-1 and following ones).
This European Standard applies to boilers of types B and C.
NOTE For further background information on appliance types see CEN/TR 1749:2014 [1].
a) that use one or more combustible gases of the three gas families at the pressures stated in EN 437;
b) where the temperature of the water is below or above 105 °C during normal operation;
c) where the maximum operating pressure in the water circuit does not exceed 6 bar;
d) which can give rise to condensation under certain circumstances;
e) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler" or an "other boiler". If no declaration is given the boiler is to be considered both a "standard boiler" and an "other boiler";
NOTE The Ecodesign Directive defines "other boilers", "low temperature boilers" and "condensing boilers". The Boiler Efficiency Directive defines "standard boilers", "low temperature boilers" and "condensing boilers". Depending on the legislation applied, a boiler can be both "a standard boiler" and an "other boiler"."
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit.
This European Standard applies to boilers designed for sealed water systems or for open water systems.
NOTE This general standard and the specific standards (see Part 2) provide requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard or a specific standard, the risk associated with this alternative construction will need to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This European Standard is not intended to cover appliances intended for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex EE).
This European Standard is not intended to cover appliances designed and constructed to burn gas containing toxic components.
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 06-Sep-2022
- 27.060.30
- 91.140.10
- CEN/TC 109
This European Standard specifies the common requirements and test methods, as well as the classification, marking and energy labelling of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as “boilers”.
This European Standard is to be used in conjunction with the specific Parts 2 (Part 2-1 and following ones).
This European Standard applies to boilers of types B and C.
NOTE For further background information on appliance types see CEN/TR 1749:2014 [1].
a) that use one or more combustible gases of the three gas families at the pressures stated in EN 437;
b) where the temperature of the water is below or above 105 °C during normal operation;
c) where the maximum operating pressure in the water circuit does not exceed 6 bar;
d) which can give rise to condensation under certain circumstances;
e) which are declared in the instructions for installation to be either a "condensing" boiler or a "low temperature boiler" or a "standard boiler" or an "other boiler". If no declaration is given the boiler is to be considered both a "standard boiler" and an "other boiler";
NOTE The Ecodesign Directive defines "other boilers", "low temperature boilers" and "condensing boilers". The Boiler Efficiency Directive defines "standard boilers", "low temperature boilers" and "condensing boilers". Depending on the legislation applied, a boiler can be both "a standard boiler" and an "other boiler"."
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle as a single unit.
This European Standard applies to boilers designed for sealed water systems or for open water systems.
NOTE This general standard and the specific standards (see Part 2) provide requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard or a specific standard, the risk associated with this alternative construction will need to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This European Standard is not intended to cover appliances intended for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex EE).
This European Standard is not intended to cover appliances designed and constructed to burn gas containing toxic components.
- Standard213 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft215 pagesEnglish languagesale 10% offe-Library read for×1 day
- 27-Feb-2022
- 30-May-2022
- 27.060.30
- 91.140.10
- 2016/426
- 811/2013
- 813/2013
- M/066
- M/534
- M/535
- M/BC/CEN/89/6
- CEN/TC 109
Questions, Comments and Discussion