Petroleum products and related materials - Determination of hydrocarbon types - Fluorescent indicator adsorption method

This European Standard specifies a fluorescent indicator adsorption method for the determination of hydrocarbon types over the concentration ranges from 5 % (V/V) to 99 % (V/V) aromatic hydrocarbons, 0,3 % (V/V) to 55 % (V/V) olefins, and 1 % (V/V) to 95 % (V/V) saturated hydrocarbons in petroleum fractions that distil below 315 ºC. This method may apply to concentrations outside these ranges, but the precision has not been determined.
When samples containing oxygenated blending components are analysed, the hydrocarbon type results can be reported on an oxygenate-free basis or, when the oxygenate content is known, the results can be corrected to a total-sample basis.
This test method is for use with full boiling range products. Cooperative data have established that the precision statement does not apply to petroleum fractions with narrow boiling ranges near the 315 °C limit. Such samples are not eluted properly, and results are erratic.
Samples containing dark-coloured components that interfere with reading the chromatographic bands cannot be analysed.
NOTE 1   The oxygenated blending components methanol, ethanol, tert-butyl methyl ether (MTBE), methyl tert-pentyl ether (TAME) and tert-butyl ethyl ether (ETBE) do not interfere with the determination of hydrocarbon types at concentrations normally found in commercial petroleum blends. These oxygenated compounds are not detected since they elute with the alcohol desorbent. The effects of other oxygenated compounds should be individually verified.
NOTE 2   For the purposes of this European Standard, the terms “% (m/m)” and “% (V/V)” are used to represent respectively the mass fraction and the volume fraction.
WARNING — The use of this European Standard may involve hazardous materials, operations and equipment. This European Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices

Mineralölerzeugnisse und verwandte Produkte - Bestimmung der Kohlenwasserstofftypen - Adsorptionsverfahren mit Fluoreszenz-Indikator

Diese Europäische Norm legt ein Adsorptionsverfahren mit Fluoreszenz Indikator fest für die Bestimmung der nachfolgend genannten Kohlenwasserstofftypen in Mineralölfraktionen, die unterhalb von 315 °C sieden, und zwar für aromatische Kohlenwasserstoffe im Bereich von 5 % (V/V) bis 99 % (V/V), für olefinische Kohlenwasserstoffe im Bereich von 0,3 % (V/V) bis 55 % (V/V) und für gesättigte Kohlenwasserstoffe im Bereich von 1 % (V/V) bis 95 % (V/V). Das Prüfverfahren kann auch auf Produkte mit Gehalten außerhalb der angegebenen Konzentrationsbereiche angewendet werden, jedoch sind für solche Produkte keine Angaben zur Präzision vorhanden.
Für Proben, die sauerstoffhaltige Verbindungen enthalten, können die Kohlenwasserstofftypen ohne Berücksichtigung der sauerstoffhaltigen Verbindungen (d. h. bezogen auf den sauerstoffverbindungsfreien Probenanteil) angegeben werden, oder aber, wenn der Gehalt an sauerstoffhaltigen Verbindungen bekannt ist, auch nach entsprechender Umrechnung mit Bezug auf die Gesamtprobe.
Dieses Prüfverfahren wird auf Proben angewendet, die den gesamten angegebenen Siedebereich überstreichen. Untersuchungen haben gezeigt, dass die Präzisionsangaben nicht gelten für engsiedende Mineralölfraktionen nahe der angegebenen Grenze von 315 °C. Solche Proben werden nicht ordnungsgemäß eluiert und führen daher zu fehlerhaften Ergebnissen.
Proben, die dunkel gefärbte Komponenten enthalten, welche die Auswertung der chromatographischen Zonen stören, können mit diesem Prüfverfahren nicht untersucht werden.
ANMERKUNG 1   Die sauerstoffhaltigen Blendkomponenten Methanol, Ethanol, tert Butylmethylether (MTBE), Methyl tert pentylether (TAME, tert Amylmethylether) und tert Butylethylether (ETBE) stören mit für kommerzielle Kraftstoffmischungen üblichen Gehalten die Bestimmung nicht. Diese Blendkomponenten werden nicht erfasst, weil sie zusammen mit dem Laufmittel eluieren. Die Einflüsse anderer sauerstoffhaltiger Verbindungen sollten im Einzelfall geprüft werden.

Produits pétroliers et produits connexes - Détermination des groupes d'hydrocarbures - Méthode par adsorption en présence d'indicateur fluorescent

Naftni proizvodi in sorodni materiali - Določevanje vrste ogljikovodikov - Adsorpcijska metoda s fluorescenčnim indikatorjem

General Information

Status
Withdrawn
Publication Date
03-Apr-2007
Withdrawal Date
07-Dec-2021
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
08-Dec-2021

Relations

Buy Standard

Standard
EN 15553:2007
English language
19 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Petroleum products and related materials - Determination of hydrocarbon types - Fluorescent indicator adsorption methodProduits pétroliers et produits connexes - Détermination des groups d'hydrocarbures - Méthode par adsorption en présence d'indicateur fluorescentMineralölerzeugnisse und verwandte Produkte - Bestimmung der Kohlenwasserstofftypen - Adsorptionsverfahren mit Fluoreszenz-IndikatorTa slovenski standard je istoveten z:EN 15553:2007SIST EN 15553:2007en;fr;de75.080Naftni proizvodi na splošnoPetroleum products in generalICS:SLOVENSKI
STANDARDSIST EN 15553:200701-junij-2007

EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15553April 2007ICS 75.080 English VersionPetroleum products and related materials - Determination ofhydrocarbon types - Fluorescent indicator adsorption methodProduits pétroliers et produits connexes - Déterminationdes groupes d'hydrocarbures - Méthode par adsorption enprésence d'indicateur fluorescentMineralölerzeugnisse und verwandte Produkte -Bestimmung der Kohlenwasserstofftypen - Adsorptionsverfahren mit Fluoreszenz-IndikatorThis European Standard was approved by CEN on 24 February 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15553:2007: E

Specification for silica gel.16 Annex B (informative)
Standard adsorption column.17 Bibliography.19

1) A list of suppliers is available from the Energy Institute, London.

Table 1 — Precision bore column dimensions and tolerance limits Charger section Inside diameter 12 mm ± 2 mm Overall length 150 mm ± 5 mm Neck section Inside diameter 2 mm ± 0,5 mm Overall length 50 mm ± 5 mm Separator section Inside diameter 5 mm ± 0,5 mm Overall length 190 mm ± 5 mm Analyzer section Inside diameter 1,60 mm to 1,65 mm Overall length 1 200mm ± 30 mm Tip Overall length 30 mm ± 5 mm

Key 1 charger 2 neck 3 separator 4 tip 5 analyzer 6 pressuring gas 7 spherical joint S29 8 pack gel to this level 9 long taper 10 dyed gel 11 zone measuring device (optional) 12 long taper 13 polyvinyl tubing 14 precision bore capillary tubing 15 standard wall tubing 16 spherical joint S13 17 tip drawn out to fine capillary Figure 1 — Adsorption columns with a) standard wall and b) precision bore tubing in analyzer section
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.