Abstract

This document specifies electrical safety requirements for electrical systems of rough-terrain variable-reach trucks and slewing rough-terrain variable-reach trucks powered by one or more electric motors (hereafter referred to as trucks), namely pure electric and hybrid electric trucks, including when hydraulic systems are electrically powered. This document applies to electrical systems with maximum voltage greater than 32 up to 1500 V DC or greater than 21 up to 1000 V AC r.m.s.
This document deals with all significant hazards, hazardous situations and events relevant to the trucks when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
The significant hazards (see EN ISO 12100:2010, Annex B) dealt with in this document are listed in Annex A.
This document does not deal with hazards which could occur:
-   during construction;
-   when operating trucks in potentially explosive atmospheres.
This document does not cover:
-   electrical systems of trucks with maximum working voltage up to 32 V DC or 21 V AC r.m.s (see relevant requirements in EN 1459-1 or EN 1459-2, as applicable);
-   electric regenerative braking systems;
-   electrical systems of externally-powered trucks designed for operation only when mains-connected.
NOTE   Electrical systems of trucks designed to be both externally-powered and self-propelled are covered in this document when not mains-connected.
This document does not deal with sales literature.
This document does not address hazards specifically related to:
-   trucks designed to operate with varying levels of autonomy (autonomous trucks), including trucks which move autonomously to the charging station, or when truck has embedded safety-systems with fully or partially self-evolving behaviour or logic using machine learning approaches;
-   trucks with communication network connection.
This document is not applicable to trucks manufactured before the date of its publication.

Status
Not Published
Publication Date
08-Dec-2026
Current Stage
6055 - CEN Ratification completed (DOR) - Publishing
Start Date
18-Oct-2026
Due Date
28-May-2026
Completion Date
28-May-2026

Buy Documents

EN 1459-7:2026 is a CEN European standard for the electrification of rough-terrain variable-reach trucks and slewing rough-terrain variable-reach trucks. It specifies electrical safety requirements and verification methods for pure electric and hybrid electric trucks, including trucks with electrically powered hydraulic systems, for electrical systems above the low-voltage ranges covered by EN 1459-1 or EN 1459-2.

The standard is for manufacturers, test labs, safety engineers, and buyers who need to check whether the truck’s electrical design, charging arrangement, protection against electric shock, emergency functions, and user information are suitable for this product type.

What does EN 1459-7:2026 specify?

EN 1459-7:2026 specifies electrical safety requirements for the electrical systems of rough-terrain variable-reach trucks and slewing rough-terrain variable-reach trucks powered by electric motors. It covers intended use and reasonably foreseeable misuse, and it organizes the document into general scope, normative references, terms and definitions, safety requirements, verification, and information for use.

The standard applies to systems with maximum voltage greater than 32 up to 1500 V DC or greater than 21 up to 1000 V AC r.m.s. It excludes construction-phase hazards and operation in potentially explosive atmospheres, and it leaves low-voltage truck systems, electric regenerative braking systems, and mains-only externally powered trucks outside its coverage.

AnnexWhat it covers
Annex AInformative list of significant hazards addressed by the standard
Annex BNormative method for measuring insulation resistance
Annex ZAInformative relationship with Directive 2006/42/EC
Annex ZBInformative relationship with Regulation (EU) 2023/1230

What are the key requirements of EN 1459-7:2026?

EN 1459-7:2026 is built around protection against electric shock, fire, unintended movement, and hazards linked to charging and battery systems. In practice, it tells the manufacturer what to design, what to test, and what to explain to the operator and maintainer.

General safety approach

Clause 4.1 requires the truck to meet the electrical safety measures in this part and, for hazards not covered here, to follow the safety principles of EN ISO 12100 and the relevant base truck standard, EN 1459-1 or EN 1459-2 as applicable. This matters because electrical design is only one part of the safety case: the rest of the truck still has to be safe as a machine.

Clause 4.1.3 also sets the voltage-range expectation for REESS-powered trucks. Lead-acid systems must be designed for 70 % to 120 % of nominal voltage, while other REESS types follow the REESS instructions. That means the electrical design must tolerate the battery’s real operating range, not just its nameplate value.

Protection against direct and indirect contact

Clause 4.2 requires barriers, insulation, or enclosures that cannot be removed without tools or keys, together with minimum protection degrees based on cab type and voltage class. It also adds connector requirements so live parts are not reachable during normal handling. For a buyer or integrator, this is the section that controls shock risk at access points, couplers, and service areas.

Clause 4.3 addresses indirect contact. For VC-B systems, exposed conductive parts must be securely bonded to the truck frame, and the resistance of that bonding path is tightly controlled. Where the truck connects to grounded external power, the frame must be connected to earth before supply is applied and kept connected until after supply is removed, unless class II protection is used. In practice, this is what prevents a metal enclosure or chassis from becoming dangerous if a fault occurs.

Insulation resistance and monitoring

Clause 4.4 sets insulation resistance expectations for VC-B trucks and allows them to be applied to VC-A2 trucks. It covers the truck as a whole, the REESS, and the charging coupling system. VC-B trucks must also have an on-board insulation monitoring device that warns the operator when insulation resistance drops below the required level.

This matters because insulation failure is often invisible until a fault current or shock hazard appears. The standard therefore requires both a design level and a way to detect degradation during operation.

REESS protection

Clause 4.5 focuses on the rechargeable electrical energy storage system [REESS]. The truck must have protective devices against excessive current, and the battery management system [BMS] or machine control system must initiate corrective action if overheating becomes a risk. For open-type lead-acid REESS, the document requires measures against gas accumulation during use and charging, and it requires protection against electrolyte spill and accidental detachment.

In practice, this is the section that drives enclosure design, ventilation, fastening, and fault handling for the battery pack and its associated equipment.

In-use safety and control behavior

Clause 4.6 covers how the truck behaves in operation. The truck must not start moving unless the speed and direction controls are activated from neutral, charging must block powered travel, and the direction control state must be clear to the operator. If the drive system enters limited mode, significant power reduction must be indicated, and restoring full drive must not create unintended movement.

Clause 4.6.4 also requires a visible indication of REESS state of charge. That helps the operator understand available energy and reduces surprises during work, transport, or charging planning.

Emergency stopping and switching off

Clause 4.7 requires an emergency stop control at the operating position and emergency switching off controls that are accessible where they are needed. The document sets response times, reset behavior, and device types, and it requires positive opening action and red color for several switching-off devices.

For normal users, this means there must be a clearly identified way to stop movement and isolate electrical power quickly, without automatic restart after reset.

Verification and user information

Clause 5 gives the verification methods, including insulation resistance measurement and equipotential bonding continuity tests. Clause 6 then requires operator and maintenance information, including charging areas and ventilation, charging procedure, switching-off controls, residual voltage discharge, wire identification, frame fault repair, and checks of the insulation monitoring device.

What terms does EN 1459-7:2026 define?

  • Voltage class - A classification of an electric component or circuit according to its maximum working voltage.
  • Maximum working voltage - The highest AC or DC voltage that can occur in normal operation according to the manufacturer’s specifications, excluding transients and ripple.
  • Direct contact - Electric contact between people or livestock and live parts.
  • Indirect contact - Electric contact with exposed conductive parts that have become live under fault conditions.
  • REESS - Rechargeable electrical energy storage system, including its physical support, battery management system, and casing.
  • BMS - Battery management system; it controls and monitors the battery and can limit overcharge, overcurrent, overdischarge, and overheating.
  • Truck inlet - The on-board charging connection point that accepts a flexible cable for charging the REESS.
  • Regenerative braking - Braking that converts kinetic energy into electric energy for charging the REESS.

Who uses EN 1459-7:2026?

EN 1459-7:2026 is used by truck manufacturers, electrical system designers, and compliance engineers who need to design and verify electrified rough-terrain trucks. It is also used by test laboratories, certification and market-surveillance bodies, and health and safety organizations that assess whether the truck meets the relevant safety expectations.

Maintenance providers and fleet owners use it when they need instructions for charging, isolation, residual voltage control, fault finding, and insulation monitoring checks. Buyers and specifiers use it to compare electric truck offerings and to confirm that the machine architecture matches the intended use.

Which standards are used with EN 1459-7:2026?

  • EN ISO 12100 - Provides the general principles of risk assessment and risk reduction used for hazards not covered directly by this part.
  • EN 1459-1 - Covers variable-reach rough-terrain trucks and supplies the requirements for hazards outside this electrification part.
  • EN 1459-2 - Covers slewing variable-reach rough-terrain trucks and supplies the requirements for hazards outside this electrification part.
  • EN 60529 - Provides the IP Code used for enclosure protection degrees such as IPXXB and IPXXD.
  • EN ISO 6682 - Defines zones of comfort and reach for controls, used for the zone of reach in the protection table.
  • ISO 7000 - Provides the graphical symbols used for warning and safety signs on the truck.
  • EN 60204-1 - Supplies general electrical equipment requirements, including fault protection, overcurrent protection, equipotential bonding, and residual-voltage-related provisions.
  • EN ISO 17409 - Applies to conductive power transfer and is used for charging modes 2, 3, or 4.
  • EN ISO 13850 - Defines emergency stop design principles used for the emergency stop control.
  • EN 60947-5-5 - Specifies the emergency stop device with mechanical latching function used for positive opening action devices.

What does the EN 1459-7:2026 document contain?

The document contains a voltage-class table, a protection-degree table, safety sign figures, and a detailed annex on insulation resistance measurement. It also includes the list of significant hazards addressed by the standard, which helps users see which machine risks the electrification requirements are intended to cover.

Annex B gives a practical measurement method, including divided measurement, use of external DC sources, and a method that uses the truck’s own REESS. The annex also includes figures showing the test set-ups and formulas for calculating insulation resistance, which makes the requirement testable in laboratory and type-test work.

Clause 6 contains the information-for-use content that should appear in the operator’s manual and maintenance manual. For people writing technical files, service instructions, or verification reports, this part is where the standard turns design rules into documentation and operating guidance.

Buy Documents

Get Certified

Connect with accredited certification bodies for this standard

TÜV Rheinland

TÜV Rheinland is a leading international provider of technical services.

DAKKS Germany Verified

TÜV SÜD

TÜV SÜD is a trusted partner of choice for safety, security and sustainability solutions.

DAKKS Germany Verified

DEKRA Certification Inc.

DEKRA US certification services.

ANAB United States Verified

Sponsored listings

Frequently Asked Questions

EN 1459-7:2026 is a draft published by the European Committee for Standardization (CEN). Its full title is "Rough-terrain trucks - Safety requirements and verification - Part 7: Electrification". This standard covers: This document specifies electrical safety requirements for electrical systems of rough-terrain variable-reach trucks and slewing rough-terrain variable-reach trucks powered by one or more electric motors (hereafter referred to as trucks), namely pure electric and hybrid electric trucks, including when hydraulic systems are electrically powered. This document applies to electrical systems with maximum voltage greater than 32 up to 1500 V DC or greater than 21 up to 1000 V AC r.m.s. This document deals with all significant hazards, hazardous situations and events relevant to the trucks when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer. The significant hazards (see EN ISO 12100:2010, Annex B) dealt with in this document are listed in Annex A. This document does not deal with hazards which could occur: - during construction; - when operating trucks in potentially explosive atmospheres. This document does not cover: - electrical systems of trucks with maximum working voltage up to 32 V DC or 21 V AC r.m.s (see relevant requirements in EN 1459-1 or EN 1459-2, as applicable); - electric regenerative braking systems; - electrical systems of externally-powered trucks designed for operation only when mains-connected. NOTE Electrical systems of trucks designed to be both externally-powered and self-propelled are covered in this document when not mains-connected. This document does not deal with sales literature. This document does not address hazards specifically related to: - trucks designed to operate with varying levels of autonomy (autonomous trucks), including trucks which move autonomously to the charging station, or when truck has embedded safety-systems with fully or partially self-evolving behaviour or logic using machine learning approaches; - trucks with communication network connection. This document is not applicable to trucks manufactured before the date of its publication.

This document specifies electrical safety requirements for electrical systems of rough-terrain variable-reach trucks and slewing rough-terrain variable-reach trucks powered by one or more electric motors (hereafter referred to as trucks), namely pure electric and hybrid electric trucks, including when hydraulic systems are electrically powered. This document applies to electrical systems with maximum voltage greater than 32 up to 1500 V DC or greater than 21 up to 1000 V AC r.m.s. This document deals with all significant hazards, hazardous situations and events relevant to the trucks when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer. The significant hazards (see EN ISO 12100:2010, Annex B) dealt with in this document are listed in Annex A. This document does not deal with hazards which could occur: - during construction; - when operating trucks in potentially explosive atmospheres. This document does not cover: - electrical systems of trucks with maximum working voltage up to 32 V DC or 21 V AC r.m.s (see relevant requirements in EN 1459-1 or EN 1459-2, as applicable); - electric regenerative braking systems; - electrical systems of externally-powered trucks designed for operation only when mains-connected. NOTE Electrical systems of trucks designed to be both externally-powered and self-propelled are covered in this document when not mains-connected. This document does not deal with sales literature. This document does not address hazards specifically related to: - trucks designed to operate with varying levels of autonomy (autonomous trucks), including trucks which move autonomously to the charging station, or when truck has embedded safety-systems with fully or partially self-evolving behaviour or logic using machine learning approaches; - trucks with communication network connection. This document is not applicable to trucks manufactured before the date of its publication.

EN 1459-7:2026 is classified under the following ICS (International Classification for Standards) categories: 43.120 - Electric road vehicles; 53.060 - Industrial trucks. The ICS classification helps identify the subject area and facilitates finding related standards.

EN 1459-7:2026 is associated with the following European legislation: EU Directives/Regulations: 2006/42/EC, 2023/1230; Standardization Mandates: M/396, M/605. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.

EN 1459-7:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 voltage class
  • 3.2 maximum working voltage
  • 3.3 direct contact
  • 3.4 live part
  • 3.5 indirect contact
  • 3.7 connector
  • 3.8 end-of-charge voltage
  • 3.9 exposed conductive part
  • 3.10 hybrid truck
  • 3.11 rechargeable electrical energy storage system
  • 3.12 conductive part
  • 3.13 basic insulation
  • 3.14 REESS nominal voltage
  • 3.15 battery management system
  • 3.16 truck inlet
  • 3.17 regenerative braking
  • 4 Safety requirements and/or protective measures
  • 4.1 General
  • 4.2 Protection against direct contact with live parts
  • 4.3 Protection against indirect contact
  • 4.4 Insulation resistance
  • 4.5 Rechargeable electric energy storage system (REESS)
  • 4.6 In-use safety requirements
  • 4.7 Emergency operations
  • 5 Verification
  • 5.1 Measurements of insulation resistance
  • 5.2 Continuity test for equipotential bonding
  • 6 Information for use
  • 6.1 General
  • 6.2 Contents
  • 6.3 Signals and warning devices
  • Annex A
  • 1 Mechanical hazards
  • 1.1 Due to machine parts or 1.3.3 Risks due to falling -
  • 4.5.4 1.3.2 Risk of break-up
  • 1.3 Crushing 1.3 Protection against -
  • 1.4 Shearing 1.3 Protection against -
  • 1.5 Cutting or severing 1.3.4 Risks due to -
  • 1.6 Entanglement 1.3 Protection against -
  • 1.7 Drawing-in or trapping 1.3 Protection against -
  • 1.9 Stabbing or puncture 1.3 Protection against -
  • 1.10 Friction or abrasion 1.3.4 Risks due to -
  • 1.11 Injection 1.3.2 Risk of break-up -
  • 1.12 Slipping, tripping and falling 1.5.15 Risk of slipping, -
  • 1.13 Instability 1.1.5 Design of -
  • 2 Electrical hazards
  • 4.19 2.6 Projection of molten particles 1.5.5 Extreme -
  • 4.4 2.9 Thermal radiation 1.5.1 Electricity supply 4.5.1
  • 3 Thermal hazards
  • 3.1 Burn, scald 1.5.5 Extreme -
  • 3.2 Frostbite 1.5.5 Extreme -
  • 3.3 Radiation of heat sources 1.5.5 Extreme -
  • 3.4 Dehydration 1.5.5 Extreme -
  • 4 Noise hazards
  • 4.1 Permanent hearing loss, 1.5.8 Noise -
  • 4.2 As a consequence of an 1.5.8 Noise -
  • 4.3 Physiological impairment 1.5.8 Noise -
  • 5 Vibration hazards
  • 5.1 Vibrations transmitted to the 1.1.8 Seating -
  • 5.2 Portable hand-held and/or 1.5.9 Vibrations -
  • 5.3 In conjunction with a rigid 1.5.9 Vibrations -
  • 6 Radiation hazards
  • 6.1 Low frequency 1.5.10 Radiation 4.1.2 See EN 1459-1:2025, 4.20 or
  • 4.19 6.2 Radio frequency 1.5.10 Radiation 4.1.2 See EN 1459-1:2025, 4.20 or
  • 4.19 6.3 Optical radiation (infrared, 1.5.10 Radiation -
  • 6.4 Laser 1.5.12 Laser radiation -
  • 6.5 Ionizing radiation source 1.5.10 Radiation -
  • 7 Material/ substance hazards
  • 7.3 Explosion 1.5.7 Explosion -
  • 8 Ergonomic hazards
  • 8.1 Unhealthy postures or 1.1.5 Design of -
  • 8.2 Inadequate consideration of 1.1.6 Ergonomics -
  • 2.2 Portable hand-held
  • 8.3 Insufficient means for 1.1.7 Operating positions -
  • 8.4 Inadequate local lighting 1.1.4 Lighting -
  • 8.5 Design or location of 1.7.1 Information and -

Introduction

This document is a type-C standard as stated in EN ISO 12100.

This document is of relevance, in particular, for the following stakeholder groups representing the market players with regard to machinery safety:

  • machine manufacturers (small, medium and large enterprises);
  • health and safety bodies (regulators, accident prevention organizations, market surveillance, etc.). Others can be affected by the level of machinery safety achieved with the means of the document by the above-mentioned stakeholder groups:
  • machine users/employers (small, medium and large enterprises);
  • machine users/employees (e.g. trade unions, organizations for people with special needs);
  • service providers, e.g. for maintenance (small, medium and large enterprises);
  • consumers (in case of machinery intended for use by consumers). The above-mentioned stakeholder groups have been given the possibility to participate at the drafting process of this document.

The machinery concerned and the extent to which hazards, hazardous situations or hazardous events are covered are indicated in the Scope of this document.

When requirements of this type-C standard are different from those which are stated in type-A or type-B standards, the requirements of this type-C standard take precedence over the requirements of the other standards for machines that have been designed and built according to the requirements of this type-C standard.

oSIST prEN 1459-7:2025 prEN 1459-7:2025 (E)

1 Scope

This document specifies electrical safety requirements for electrical systems of rough-terrain variablereach trucks and slewing rough-terrain variable-reach trucks powered by one or more electric motors (hereafter referred to as trucks), namely pure electric and hybrid electric trucks, including when hydraulic systems are electrically powered. This document applies to electrical systems with maximum voltage greater than 32 up to 1500 V DC or greater than 21 up to 1000 V AC r.m.s. This document deals with all significant hazards, hazardous situations and events relevant to the trucks when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.

The significant hazards (see EN ISO 12100:2010, Annex B) dealt with in this document are listed in Annex A.

This document does not deal with hazards which could occur:

  • during construction;
  • when operating trucks in potentially explosive atmospheres.

This document does not cover:

- electrical systems of trucks with maximum working voltage up to 32 V DC or 21 V AC r.m.s (see relevant requirements in EN 1459-1 or EN 1459-2, as applicable); - electric regenerative braking systems; - electrical systems of externally-powered trucks designed for operation only when mains-connected. NOTE Electrical systems of trucks designed to be both externally-powered and self-propelled are covered in this document when not mains-connected.

This document does not deal with sales literature.

This document does not address hazards specifically related to:

  • trucks designed to operate with varying levels of autonomy (autonomous trucks), including trucks which move autonomously to the charging station, or when truck has embedded safety-systems with fully or partially self-evolving behaviour or logic using machine learning approaches;
  • trucks with communication network connection.

This document is not applicable to trucks manufactured before the date of its publication.

oSIST prEN 1459-7:2025 prEN 1459-7:2025 (E)

2 Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

EN 60529:1991, Degrees of protection provided by enclosures (IP Code) EN ISO 6682:2008, Earth-moving machinery — Zones of comfort and reach for controls (ISO 6682:1986, including Amd 1:1989) ISO 7000:2019, Graphical symbols for use on equipment — Registered symbols EN 60204-1:2018, Safety of machinery — Electrical equipment of machines — Part 1: General requirements EN ISO 17409:2020, Electrically propelled road vehicles — Conductive power transfer — Safety requirements (ISO 17409:2020) EN ISO 13850:2015, Safety of machinery — Emergency stop function — Principles for design (ISO 13850:2015)

EN 60947-5-5:1997, Low-voltage switchgear and controlgear — Part 5-5: Control circuit devices and switching elements — Electrical emergency stop device with mechanical latching function EN ISO 12100:2010, Safety of machinery — General principles for design — Risk assessment and risk reduction (ISO 12100:2010) EN 1459-1:2025, Rough-terrain trucks — Safety requirements and verification — Part 1: Variable-reach trucks EN 1459-2:2015+A1:2018, Rough-terrain trucks — Safety requirements and verification — Part 2: Slewing variable-reach trucks

3 Terms and definitions

For the purposes of this document, the terms and definitions given in EN 1459-1:2025, EN 1459-2:2015+A1:2018 and the following apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

  • ISO Online browsing platform: available at https://www.iso.org/obp/
  • IEC Electropedia: available at https://www.electropedia.org/

3.1 voltage class

classification of an electric component or circuit according to its maximum working voltage (3.2) [SOURCE: ISO 6469-3:2021, definition 3.36]

As impacted by EN 60529:1991/corrigendum May 1993, EN 60529:1991/A1:2000. EN 60529:1991/A2:2013 and EN 60529:1991/AC:2016-12.

As impacted by EN 60947-5-5:1997/A1:2005, EN 60947-5-5:1997/A2:2017 and EN 60947-5-5:1997/A11:2013.

oSIST prEN 1459-7:2025 prEN 1459-7:2025 (E) Table 1 — Voltage classes Maximum working voltage Voltage class V DC V AC r.m.s.

VC-A 0 < U ≤ 60 0 < U ≤ 30 VC-A1 0 < U ≤ 32 0 < U ≤ 21 VC-A2 32 < U ≤ 60 21 < U ≤ 30 VC-B 60 < U ≤ 1500 30 < U ≤ 1000 VC-B1 60 < U ≤ 75 30 < U ≤ 50 VC-B2 75 < U ≤ 1500 50 < U ≤ 1000 VC-C 1500 < U ≤ 36000 1000 < U ≤ 36000 U = maximum working voltage NOTE The classification of voltage classes VC-A, VC-B and VC-C is according to ISO 6469-3:2021.

3.2 maximum working voltage

highest value of AC voltage (r.m.s) or of DC voltage that can occur under any normal operating conditions according to the manufacturer's specifications, disregarding transients and ripple [SOURCE: ISO 6469-3:2021, definition 3.26]

3.3 direct contact

electric contact of human beings or livestock with live parts [IEV ref 195-06-03]

3.4 live part

conductor or conductive part intended to be energized in normal use Note 1 to entry: This concept does not necessarily imply a risk of electric shock. [SOURCE: IEC 60050-826:2004, definition 826-12-08, modified – Reference to PEN, PEL and PEM conductors removed, reference to running rails added. IEC 62128-1:2013, definition 3.1.13]

3.5 indirect contact

electric contact of human beings or livestock with exposed-conductive-parts that have become live under fault conditions [IEV ref 195-06-04]

3.7 connector

device designed for providing connection and disconnection to a suitable mating component [IEV ref 482-05-55]

oSIST prEN 1459-7:2025 prEN 1459-7:2025 (E) Note 1 to entry: A connector has one or more contact members.

3.8 end-of-charge voltage

voltage attained at the end of a charging step, at a specified constant current [IEV ref 151-12-19, MOD]

3.9 exposed conductive part

conductive part of equipment that can be touched under the provisions of the protection degree IPXXB and that is not live under normal conditions, but that can become live when basic insulation fails [IEV ref 195-06-10, MOD]

3.10 hybrid truck

truck powered by at least two different on-board energy storage systems and two different energy converters, where at least one converter converts electrical energy

3.11 rechargeable electrical energy storage system

REESS rechargeable system with maximum voltage greater than 32 up to 1500 V DC that provides electrical energy Note 1 to entry: REESS includes the necessary systems for physical support, the battery management system and the casing.

3.12 conductive part

part which can carry electric current [IEV ref 195-01-06]

3.13 basic insulation

insulation applied to live parts for protection against direct contact under fault-free conditions Note 1 to entry: Where insulation is not provided by solid insulation only, it is complemented with protective barriers or protective enclosures to prevent access to live parts in order to achieve basic protection.

3.14 REESS nominal voltage

value of the voltage used by the manufacturer or supplier to designate or identify a REESS [IEV ref 482-03-31, MOD]

3.15 battery management system

BMS electronic system associated with a battery which has functions to control current in case of overcharge, overcurrent, overdischarge, and overheating, and which monitors and/or manages the state of the

oSIST prEN 1459-7:2025 prEN 1459-7:2025 (E) battery, calculates secondary data, reports that data and/or controls its environment to influence the battery's safety, performance and/or service life Note 1 to entry: Overdischarge cut off is not mandatory if there is an agreement on this between the cell manufacturer and the customer.

Note 2 to entry: The function of the battery management system (BMS) can be assigned to the battery pack or to equipment that uses the battery.

Note 3 to entry: The BMS can be divided and it can be found partially in the battery pack and partially on the equipment that uses the battery.

Note 4 to entry: The BMS is sometimes also referred to as a BMU (battery management unit).

3.16 truck inlet

part of a truck equipped with an on-board charger enabling the connection of a flexible cable for charging the REESS

3.17 regenerative braking

braking with conversion of kinetic energy into electric energy for charging the rechargeable electrical energy storage system (REESS)

4 Safety requirements and/or protective measures

4.1 General

4.1.1 Context

Trucks shall comply with the safety requirements and/or protective/risk reduction measures of this clause. In addition, trucks shall be designed according to the principles of EN ISO 12100:2010 for relevant but not significant hazards which are not dealt with by this document. 4.1.2 Specific relation with EN 1459-1 and EN 1459-2 Trucks shall comply with EN 1459-1:2025 or EN 1459-2:2015+A1:2018, as applicable, for the significant hazards not covered by this document (see Annex A).

4.1.3 Voltage range

Electrical systems of trucks powered by REESS of the lead-acid type shall be designed to operate in the voltage range from 70 % up to 120 % of the REESS nominal voltage or as indicated by the REESS instructions.

Electrical systems of trucks powered by REESS other than lead-acid type shall be designed to operate in the voltage range as indicated by the REESS instructions.

Verification by design check.

4.2 Protection against direct contact with live parts

4.2.1 Protections

The protections against direct contact with live parts (e.g. solid insulator, barrier, enclosure) shall not be able of being opened, disassembled or removed without the use of tools or keys. Verification by design check.

oSIST prEN 1459-7:2025 prEN 1459-7:2025 (E)

4.2.2 Protection degree

The minimum protection degree in accordance with EN 60529:1991 shall be as given in Table 2:

Table 2 — Protection degree Cab type Zone VC-A2 VC-B a IPXXB IPXXD zone of reach Non-enclosed cab elsewhere on the truck IPXXB IPXXB inside the cab IPXXB IPXXD Enclosed cab outside the cab IPXXB IPXXB a Zone of reach according to EN ISO 6682:2008.

Verification by type-test in accordance with EN 60529:1991 , Clause 15.

4.2.3 Specific requirements for connectors
4.2.3.1 Truck inlet

The truck inlet shall comply with the applicable standard (for example EN 60309, EN 62196). Verification by design check.

For REESS with an end-of-charge voltage exceeding 60 V, switching of external power shall be controlled via the connector auxiliary contacts or via other devices connected to the Batteries Management System to prevent arcing at the connector and to ensure that the charger is not energised until it is connected to the REESS.

Verification by design check.

4.2.3.2 Other connectors

Connectors shall be protected against accidental contacts with live parts. Connectors are deemed to meet this requirement if:

  • they comply with the protection degree IPXXB when separated without the use of tools or keys; or
  • they are provided with a locking mechanism and other components shall first be removed with the use of tools or keys in order to separate the connector; or
  • the voltage of the live parts becomes ≤ DC 60 V or ≤ AC 30 V r.m.s within one second after the connector is separated.

Verification by design check or measurement.

4.2.3.3 Service disconnection

It shall be possible to electrically disconnect the REESS for maintenance and replacement operations. Verification by design check.

Where a service disconnection can be opened, disassembled or removed without the use of tools or keys, the protection degree IPXXB shall be met.

Verification by design check.

oSIST prEN 1459-7:2025 prEN 1459-7:2025 (E)

4.2.4 Protection from residual voltages

After disconnecting the REESS, either of the following requirements shall apply:

  • the voltage of the capacitors (except REESS) shall be less than 60 V DC after 10 s, or
  • a permanent and indelible warning label shall be affixed on, or in close proximity to, the enclosure containing the capacitors. Safety signs in Figure 1 and Figure 3 shall be used. The background shall be yellow, the bordering and the symbol shall be black.

a) Symbol ISO 7000- 0434A

b) symbol ISO 7000- 0434B Figure 1 — Symbol ISO 7000- 0434A and ISO 7000- 0434B Exempted from this requirement are components having a stored charge of 60 µC or less (see EN 60204-1:2018, 6.2.4).

Verification by measurement or visual examination.

oSIST prEN 1459-7:2025 prEN 1459-7:2025 (E)

4.3 Protection against indirect contact

4.3.1 Equipotential bonding

For trucks with VC-B systems the exposed conductive parts, such as the metallic barrier and enclosure or motor frames, shall be securely galvanically connected to the truck frame for instance by connections with electrical wire, ground cable, welds or by connections using bolts so that no dangerous electric potential can exist.

Verification by design check.

The resistance between all exposed conductive parts and the electrical chassis shall be lower than 0,1 Ω when there is current flow of at least 0,2 A. This requirement is deemed as satisfied if the galvanic connection has been established by welding.

For exclusions see EN 60204-1:2018, 8.2.5.

Verification by type-test in 5.2.

4.3.2 Connection to the truck frame

For trucks with VC-B systems there shall be no electrical connection between live parts and the truck frame, except for:

  • insulation monitoring device;
  • VC-A circuits which are galvanically separated from the REESS;
  • earthing terminal of on-board chargers (see also 4.2.3).

This requirement may also be applied to VC-A2 systems.

Verification by design check.

4.3.3 On-board chargers and other connections to a grounded external power supply

When trucks are fitted with on-board chargers or other devices intended to be connected to a grounded external electric power supply through a conductive connection, a device enabling the galvanic connection of the truck frame to the earth ground shall be provided. The device shall enable connection to the earth ground before external voltage is supplied to the truck and shall retain this connection until after the exterior voltage is removed from the truck. Alternatively, class II protection may be provided (see EN 60204-1:2018, 6.3.2.2). In such case, access openings intended for inspection and maintenance of class II protection shall be provided on the truck in accordance with EN ISO 2860:2008 (see also 6.2).

The requirements of EN 60204-1:2018, 6.3 (Fault protection), 7.2.1 (Overcurrent protection) and Clause 8 (Equipotential bonding) up to and including 8.2 shall apply. EN ISO 17409:2020 shall be applied for charging modes 2, 3 or 4. A galvanic connection to the earth ground does not need to be provided if the truck cannot be charged without completely removing the REESS from the truck.

NOTE This document provides requirements on connection to the earth ground only in case the truck is involved. In case the REESS that has to be removed from the truck for charging purposes, the REESS is considered as a separate item.

Verification by design check.

oSIST prEN 1459-7:2025 prEN 1459-7:2025 (E)

4.4 Insulation resistance

4.4.1 General

Insulation resistance of VC-B trucks shall comply with the requirements set out below. The requirements may also be applied to VC-A2 trucks.

The measurements of insulation resistance shall be conducted in accordance with requirements in 5.1.

4.4.2 Insulation resistance of the truck

If AC buses and DC buses are galvanically isolated from each other, insulation resistance between all high voltage buses and the electrical chassis shall have a minimum value of 100 Ω/V of the maximum working voltage for DC buses, and a minimum value of 500 Ω/V of the maximum working voltage for AC buses.

4.4.3 Insulation resistance of the REESS

The insulation resistance between the truck frame and the live parts of the disconnected, filled and charged REESS mounted on the truck shall be at least 500 Ω/V multiplied by the maximum working voltage of the REESS.

A REESS having a nominal voltage not higher than 60 V DC, shall have an insulation resistance of at least 50 Ω multiplied by the nominal REESS voltage when measured between a REESS terminal and metallic container, vehicle frame or other conductive supporting structure.

4.4.4 Insulation resistance of the coupling system for charging the REESS

The truck inlet and the circuit that is galvanically connected to the truck inlet during charging of the REESS shall have an insulation resistance between the circuit and the truck frame of at least 1,0 MΩ when the charger coupler is disconnected. During the measurement the REESS may be disconnected.

4.4.5 Detection of frame faults (on-board insulation monitoring device)

VC-B trucks shall be provided with an on-board insulation monitoring device. Verification by design check.

The on-board insulation monitoring device shall give a visual, and optionally also audible, warning to the operator when the truck is switched on if the insulation resistance of circuits directly connected to the REESS drops below the minimum values required in 4.4.

Verification by design check.

4.5 Rechargeable electric energy storage system (REESS)

4.5.1 Protection in case of excessive current

The truck shall be equipped with one or more protective devices such as fuses, circuit breakers and/or main contactors to prevent from overheating in case of excessive current. For other than lead acid type REESS, the BMS, when fitted, or the machine control system shall be designed such that corrective measures are initiated to prevent overtemperature exposure, for example deactivation of the REESS.

The limit of the overtemperature in the BMS shall be in accordance with the specification of the REESS. NOTE The Battery Management System requirements are given in separate standards, see for example EN 62619, EN IEC 62485-6, EN 1175:2020, Clauses C.2.3.2 to C.2.6. Verification by design check.

oSIST prEN 1459-7:2025 prEN 1459-7:2025 (E)

...