EN 13174:2001
(Main)Cathodic protection for harbour installations
- BACK
- 23-Jan-2001
- 18-Dec-2012
- 77.060
- 93.140
- CEN/TC 219
Cathodic protection for harbour installations
This EN defines the means to be used to cathodically protect the immersed and buried metallic external surfaces of steel harbour installations and appurtenances in sea water and saline mud.
Kathodischer Korrosionsschutz für Hafenbauten
Diese Europäische Norm definiert die Mittel, die für den kathodischen Korrosionsschutz der eingetauchten und bodenbedeckten metallischen, äußeren Oberflächen von stählernen Hafenbauten und Zubehör in Meerwasser und salzhaltigem Schlick einzusetzen sind.
Protection cathodique des installations portuaires
La présente EN définit les moyens à mettre en oeuvre pour assurer la protection cathodique des parties métalliques externes immergées et enfouies des installations portuaires en acier et de leurs parties annexes contre la corrosion due à l'eau de mer ou aux fonds marins.
Katodna zaščita za pristaniške napeljave
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Kathodischer Korrosionsschutz für HafenbautenProtection cathodique des installations portuairesCathodic protection for harbour installations47.020.01Splošni standardi v zvezi z ladjedelništvom in konstrukcijami na morjuGeneral standards related to shipbuilding and marine structures25.220.40Kovinske prevlekeMetallic coatingsICS:Ta slovenski standard je istoveten z:EN 13174:2001SIST EN 13174:2003en01-december-2003SIST EN 13174:2003SLOVENSKI
STANDARD
SI
...
This May Also Interest You
ISO 13174:2012 defines the means to be used to ensure that cathodic protection is efficiently applied to the immersed and driven/buried metallic external surfaces of steel port, harbour, coastal and flood defence installations and appurtenances in seawater and saline mud to provide protection from corrosion.
ISO 13174:2012 specifies cathodic protection of fixed and floating port and harbour structures. This includes piers, jetties, dolphins (mooring and berthing), sheet or tubular piling, pontoons, buoys, floating docks, lock and sluice gates. It also specifies cathodic protection of the submerged areas of appurtenances, such as chains attached to the structure, when these are not electrically isolated from the structure.
ISO 13174:2012 is to be used in respect of cathodic protection systems where the anodes are exposed to water or saline mud. For buried areas, typically in soil or sand filled areas behind piled walls or within filled caissons, which may be significantly affected by corrosion, specific cathodic protection design and operation requirements are defined in EN 12954, the anodes being exposed to soils.
ISO 13174:2012 does not cover the cathodic protection of fixed or floating offshore structures (including offshore loading buoys), submarine pipelines or ships.
ISO 13174:2012 does not include the internal protection of surfaces of any components such as ballast tanks, internals of floating structures flooded compartments of lock and sluice gates or the internals of tubular steel piles.
ISO 13174:2012 covers the cathodic protection of structures fabricated principally from bare or coated carbon and carbon manganese steels.
As some parts of the structure may be made of metallic materials other than carbon steels, the cathodic protection system should be designed to ensure that there is a complete control over any galvanic coupling and minimize risks due to hydrogen embrittlement or hydrogen-induced cracking (see ISO 12473 ).
ISO 13174:2012 does not address steel reinforced concrete structures (see EN 12696).
ISO 13174:2012 is applicable to the whole submerged zone in seawater, brackish waters and saline mud and related buried areas which can normally be found in port, harbour, coastal and flood defence installations wherever these structures are fixed or floating.
For surfaces which are alternately immersed and exposed to the atmosphere, the cathodic protection is only effective when the immersion time is long enough for the steel to become polarized. Typically, effective cathodic protection is achieved for all surfaces below mid tide.
For structures such as sheet steel and tubular steel piles that are driven into the sea bed or those that are partially buried or covered in mud, ISO 13174:2012 is also applicable to the surfaces buried, driven and exposed to mud which are intended to receive cathodic protection along with surfaces immersed in water.
Cathodic protection may also be applied to the rear faces of sheet steel piled walls and the internal surfaces of filled caissons. Cathodic protection of such surfaces is specified by EN 12954.
- Standard40 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-Dec-2012
- 29-Jun-2013
- 47.020.99
- 77.060
- 93.140
- CEN/TC 219
This Technical Specification gives guidance for dealing with the production and control of sludge in relation to inputs and treatment and gives a strategic evaluation of recovery, recycling and disposal options for sludge according to its properties and the availability of outlets.
This Technical Specification is applicable for sludges from:
- storm water handling;
- night soil;
- urban wastewater collecting systems;
- urban wastewater treatment plants;
- treating industrial wastewater similar to urban wastewater (as defined in Directive 91/271/EC [1]);
- water supply treatment plants;
but excluding hazardous sludges from industry.
- Technical specification23 pagesEnglish languagesale 10% offe-Library read for×1 day
- 23-Jul-2013
- 77.060
- 93.140
- CEN/TC 308
ISO 13174:2012 defines the means to be used to ensure that cathodic protection is efficiently applied to the immersed and driven/buried metallic external surfaces of steel port, harbour, coastal and flood defence installations and appurtenances in seawater and saline mud to provide protection from corrosion.
ISO 13174:2012 specifies cathodic protection of fixed and floating port and harbour structures. This includes piers, jetties, dolphins (mooring and berthing), sheet or tubular piling, pontoons, buoys, floating docks, lock and sluice gates. It also specifies cathodic protection of the submerged areas of appurtenances, such as chains attached to the structure, when these are not electrically isolated from the structure.
ISO 13174:2012 is to be used in respect of cathodic protection systems where the anodes are exposed to water or saline mud. For buried areas, typically in soil or sand filled areas behind piled walls or within filled caissons, which may be significantly affected by corrosion, specific cathodic protection design and operation requirements are defined in EN 12954, the anodes being exposed to soils.
ISO 13174:2012 does not cover the cathodic protection of fixed or floating offshore structures (including offshore loading buoys), submarine pipelines or ships.
ISO 13174:2012 does not include the internal protection of surfaces of any components such as ballast tanks, internals of floating structures flooded compartments of lock and sluice gates or the internals of tubular steel piles.
ISO 13174:2012 covers the cathodic protection of structures fabricated principally from bare or coated carbon and carbon manganese steels.
As some parts of the structure may be made of metallic materials other than carbon steels, the cathodic protection system should be designed to ensure that there is a complete control over any galvanic coupling and minimize risks due to hydrogen embrittlement or hydrogen-induced cracking (see ISO 12473 ).
ISO 13174:2012 does not address steel reinforced concrete structures (see EN 12696).
ISO 13174:2012 is applicable to the whole submerged zone in seawater, brackish waters and saline mud and related buried areas which can normally be found in port, harbour, coastal and flood defence installations wherever these structures are fixed or floating.
For surfaces which are alternately immersed and exposed to the atmosphere, the cathodic protection is only effective when the immersion time is long enough for the steel to become polarized. Typically, effective cathodic protection is achieved for all surfaces below mid tide.
For structures such as sheet steel and tubular steel piles that are driven into the sea bed or those that are partially buried or covered in mud, ISO 13174:2012 is also applicable to the surfaces buried, driven and exposed to mud which are intended to receive cathodic protection along with surfaces immersed in water.
Cathodic protection may also be applied to the rear faces of sheet steel piled walls and the internal surfaces of filled caissons. Cathodic protection of such surfaces is specified by EN 12954.
- Standard40 pagesEnglish languagesale 10% offe-Library read for×1 day
- 18-Dec-2012
- 29-Jun-2013
- 47.020.99
- 77.060
- 93.140
- CEN/TC 219
This document specifies a test method for the determination of distension and strength of the leather grain or finished surface. This method is applicable to all flexible leathers and it is particularly suitable to determine the lastability of leathers for footwear uppers.
- Draft10 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Nov-2024
- 59.140.30
- CEN/TC 289
This document describes the specific functional requirements for the transportation of gases (gaseous energy carriers) through service lines in addition to the general functional requirements of EN 12007 1 for:
a) a maximum operating pressure (MOP) up to and including 16 bar;
b) an operating temperature between −20 °C and +40 °C;
c) gases and blends of gases which are in the gaseous state when conveyed in the gas pipeline infrastructure such as hydrogen, hydrogen rich, and methane rich gases, dimethyl ether (DME) and propane and butanes used for combustion and/or as feedstock, excluding steam and compressed air, where technical evaluation has ensured that operating conditions, constituents and properties of the gas do not affect the safe operation and maintenance of the service line.
It applies to their design, construction, commissioning, decommissioning, operation, maintenance, extension and other associated works including safety and environmental aspects. The service line is the physical asset comprising of pipework from the gas main branch saddle or top tee to the outlet of the distribution system operator’s nominated point(s) of delivery (for example: isolation valve, regulator, meter connection or combination of regulator and isolation valve).
This document does not apply retrospectively to installations before the publication date unless specifically stated.
Specific functional requirements for:
— polyethylene pipelines are given in EN 12007 2;
— steel pipelines are given in EN 12007 3;
— polyamide (PA-U) pipelines are given in CEN/TS 12007 6;
— pipework for buildings are given in EN 1775;
— pressure regulating installations are given in EN 12279 or EN 12186;
— pressure testing, commissioning and decommissioning are given in EN 12327;
— safety management system (SMS) and pipeline integrity management system (PIMS) are given in EN 17649.
This document specifies common basic principles for gas infrastructure. Users of this document are expected to be aware that there can exist more detailed national standards and/or codes of practice in the CEN member countries. This document is intended to be applied in association with these national standards and/or codes of practice setting out the above-mentioned basic principles.
In the event of terms of additional requirements in legislation/regulation than in this document, CEN/TR 13737 (all parts) illustrates these terms.
CEN/TR 13737 gives:
— description of legislations/regulations applicable in a member state;
— if appropriate, more restrictive national requirements;
— a national contact point for the latest information.
- Draft30 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Nov-2024
- 23.040.01
- M/017
- CEN/TC 234
This document specifies a high-performance liquid chromatography (HPLC) method for determining the 16-O-Methylcafestol content in green and roasted coffee.
The method is suitable for a content of 40 mg/kg to 1 600 mg/kg of 16-O-Methylcafestol of green and roasted coffee, respectively. The collaborative study has shown that mass fractions also between 20 mg/kg to 40 mg/kg can be successfully analysed depending on the laboratory equipment.
The compliance assessment process is not part of this document.
- Draft18 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Nov-2024
- 67.140.20
- CEN/TC 460
This document provides technical definitions of terms relating to authenticity and fraud when referring to food products. All terms and definitions are in the context of food supply chains, but most of them can also be applied when referring to feed products and the feed supply chain.
- Draft13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Nov-2024
- 01.040.67
- 65.120
- 67.020
- 67.050
- CEN/TC 460
This document specifies procedures, criteria and indicators meeting the sustainability criteria of European Commission Directive 2018/EU/2001 (RED II), the recast of the Renewable Energy Directive, for agricultural biomass and forest biomass for energy applications, i.e. biofuels, bioliquids and biomass fuels. This document is applicable to production, cultivation and harvesting of biomass from agricultural land and forest land for biofuels, bioliquids and biomass fuel production.
- Draft37 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Nov-2024
- 27.190
- 75.160.40
- 98/70/EC
- CEN/TC 383
This document specifies a test method using gas chromatography with mass selective detector (GC-MS) for detection and quantification of chlorobenzenes, chlorotoluenes, and α-chlorinated toluenes in fibres, yarns, fabrics, coated fabrics and plastics.
- Draft26 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Nov-2024
- 59.080.01
- CEN/TC 248
This document specifies a method for the determination of soluble 16-O-Methylcafestol and 16-O-Methylkahweol content (the sum of free forms and derivatives, e.g. fatty acid esters, henceforth abbreviated as 16-OMD = “diterpenes”) in roasted coffee (beans or ground), using quantitative proton nuclear magnetic resonance spectroscopy (1H-qNMR).
If complying with the experimental parameters described below, this test procedure has been proven for the following mass fraction range:
w16-OMD: 20 mg/kg to 2 000 mg/kg.
The mass fraction range can be expanded by suitable changes of the experimental parameters, e.g. a different weighed portion of ground coffee or the accumulation of more NMR-transients.
- Draft23 pagesEnglish languagesale 10% offe-Library read for×1 day
- 05-Nov-2024
- 67.140
- 67.140.20
- CEN/TC 460
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.