Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

Superseded by EN 61000-4-6:2009

Elektromagnetische Verträglichkeit (EMV) - Teil 4-6: Prüf- und Messverfahren - Störfestigkeit gegen leitungsgeführte Störgrößen, induziert durch hochfrequente Felder

Compatibilité électromagnétique (CEM) - Partie 4-6: Techniques d'essai et de mesure - Immunité aux perturbations conduites, induites par les champs radioélectriques

Elektromagnetna združljivost (EMC) - 4-6. del: Preskusne in merilne tehnike - Odpornost proti motnjam po vodnikih, ki jih inducirajo radiofrekvenčna polja * Tolmačenje 5. točke standarda

General Information

Status
Withdrawn
Publication Date
25-Feb-2009
Withdrawal Date
25-Aug-2009
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
01-Mar-2012
Completion Date
01-Mar-2012

Relations

Buy Standard

Addendum
EN 61000-4-6:2008/IS1:2009
English and French language
2 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 61000-4-6:2008/IS1:2009
01-september-2009
(OHNWURPDJQHWQD]GUXåOMLYRVW (0& GHO3UHVNXVQHLQPHULOQHWHKQLNH
2GSRUQRVWSURWLPRWQMDPSRYRGQLNLKNLMLKLQGXFLUDMRUDGLRIUHNYHQþQDSROMD
7ROPDþHQMHWRþNHVWDQGDUGD
Electromagnetic compatibility (EMC) -- Part 4-6: Testing and measurement techniques -
Immunity to conducted disturbances, induced by radio-frequency fields * Interpretation of
Clause 5
Ta slovenski standard je istoveten z: EN 61000-4-6:2007/IS1:2009
ICS:
33.100.20 Imunost Immunity
SIST EN 61000-4-6:2008/IS1:2009 en,fr
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 61000-4-6:2008/IS1:2009

---------------------- Page: 2 ----------------------

SIST EN 61000-4-6:2008/IS1:2009
EN 61000-4-6/IS1

Interpretation Sheet 1
EN 61000-4-6:2007
English version
___________

Foreword
This Interpretation Sheet to the European Standard EN 61000-4-6:2007 was prepared by the
Interpretation Panel of the Technical Committee CENELEC TC 210, Electromagnetic compatibility (EMC).
The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC
on 2008-11-14.

Clause 5 Test levels
Table 1 – Test levels
Question:
How to apply the test levels ?
Interpretation:
The test levels are to be applied as stated in Table 1, or as defined in the product standard, without any
increase to take into account uncertainties in the setting of the output level at the EUT port of the coup
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.