EN 61076-3-110:2016
(Main)Connectors for electronic equipment - Product requirements - Part 3-110: Detail specification for free and fixed connectors for data transmission with frequencies up to 3 000 MHz
Connectors for electronic equipment - Product requirements - Part 3-110: Detail specification for free and fixed connectors for data transmission with frequencies up to 3 000 MHz
IEC 61076-3-110:2016 This detail specification covers mechanical, electrical and environmental requirements and electrical transmission requirements for frequencies up to 3 000 MHz. These connector's transmission requirements are specifically intended for specific pairs of contacts, which are separated from the other pairs of contacts, such as by means of individual pair shields within the connector. These connectors are similar to, intermateable with, and intended to be used with the IEC 60603-7 series connectors. The IEC 60603-7 series connectors are typically used in ISO/IEC 11801 balanced cabling systems. The ISO/IEC 11801 balanced cabling systems are organized by categories according to frequency range and by basic cabling component types, e.g. according to shielding configurations. A primary common feature among the IEC 60603-7 series connectors is backward compatibility to lower frequency categories. The IEC 61076-3-110 series connectors are backward compatible with IEC 60603-7-7, IEC 60603-7-71 and IEC 60603-7-82 connectors. The IEC 61076-3-110 series connectors are not backward compatible with some IEC 60603-7 series connectors. Key words: Connectors, Free and Fixed Data Transmission, 3000 MHz
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-110: Bauartspezifikation für freie und feste Steckverbinder für Datenübertragungen bis 3 000 MHz
Connecteurs pour équipements électroniques - Exigences de produit - Partie 3-110: Spécification particulière pour les fiches et les embases pour la transmission de données à des fréquences jusqu’à 3 000 MHz
L'IEC 61076-3-110:2016 La présente spécification particulière couvre les exigences mécaniques, électriques et environnementales, et des exigences de transmission électrique pour des fréquences jusqu'à 3 000 MHz. Ces exigences de transmission des connecteurs sont spécifiquement destinées à des paires de contacts spécifiques, séparées des autres paires de contacts, par exemple au moyen d'écrans individuels par paire à l'intérieur du connecteur. Ces connecteurs sont similaires, accouplables et destinés à être utilisés avec des connecteurs de la série IEC 60603-7. Les connecteurs de la série IEC 60603-7 sont typiquement utilisés dans des systèmes de câblage symétriques de l'ISO/IEC 11801. Les systèmes de câblage symétriques de l'ISO/IEC 11801 sont organisés en catégories en fonction de leur plage de fréquences et par types de composants de câblage de base, par exemple en fonction des configurations de l'écrantage. Une caractéristique commune principale des connecteurs de la série IEC 60603-7 est la compatibilité amont avec des catégories de fréquences inférieures. Les connecteurs de la série IEC 61076-3-110 offrent une compatibilité amont avec les connecteurs de l'IEC 60603-7-7, de l'IEC 60603-7-71 et de l'IEC 60603-7-82. Les connecteurs de la série IEC 61076-3-110 n'offrent pas de compatibilité amont avec certains connecteurs de la série IEC 60603-7. Mots clés: Connecteurs, Fiches et embases pour la transmission de données, 3 000 MHz
Konektorji za elektronsko opremo - Zahteve za izdelek - 3-110. del: Podrobna specifikacija za proste in fiksne konektorje za prenos podatkov s frekvencami do 3000 MHz (IEC 61076-3-110:2016)
Ta del standarda IEC 61076 je podrobna specifikacija za dvodelne pravokotne konektorje. Ta podrobna specifikacija zajema mehanske, električne in okoljske zahteve ter zahteve za električni prenos za frekvence do 3000 MHz. Te zahteve za prenos konektorjev so posebej namenjene določenim parom kontaktov, ki so ločeni od drugih parov kontaktov, na primer s posameznimi ščiti za pare znotraj konektorja.
Ti konektorji so podobni konektorjem iz skupine standardov IEC 60603-7, se lahko spajajo z njimi in so namenjeni uporabi v kombinaciji z njimi.
Konektorji iz skupine standardov IEC 60603-7 se običajno uporabljajo v uravnoteženih kabelskih sistemih iz standarda ISO/IEC 11801. Uravnoteženi kabelski sistemi iz standarda ISO/IEC 11801 so razdeljeni v kategorije glede na frekvenčni razpon in osnovne vrste komponent kablov npr. glede na konfiguracije ščitov.
Glavna skupna lastnost konektorjev iz skupine standardov IEC 60603-7 je povratna združljivost z nižjefrekvenčnimi kategorijami. Konektorji iz skupine standardov IEC 61076-3-110 so povratno združljivi s konektorji iz standardov IEC 60603-7-7, IEC 60603-7-71 in IEC 60603-7-82. Konektorji iz skupine standardov IEC 61076-3-110 niso povratno združljivi z nekaterimi konektorji iz skupine standardov IEC 60603-7.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2017
1DGRPHãþD
SIST EN 61076-3-110:2012
Konektorji za elektronsko opremo - Zahteve za izdelek - 3-110. del: Podrobna
specifikacija za proste in fiksne konektorje za prenos podatkov s frekvencami do
3000 MHz (IEC 61076-3-110:2016)
Connectors for electronic equipment - Product requirements - Part 3-110: Detail
specification for free and fixed connectors for data transmission with frequencies up to 3
000 mhz (IEC 61076-3-110:2016)
Steckverbinder für elektronische Einrichtungen - Produktanforderungen - Teil 3-110:
Bauartspezifikation für geschirmte freie und feste Steckverbinder für
Datenübertragungen bis 1 000 MHz (IEC 61076-3-110:2016)
Connecteurs pour équipements électroniques - Exigences de produit - Partie 3-110:
Spécification particulière pour les fiches et les embases blindées pour la transmission de
données à des fréquences jusqu'à 1 000 MHz (IEC 61076-3-110:2016)
Ta slovenski standard je istoveten z: EN 61076-3-110:2016
ICS:
31.220.10 9WLþLLQYWLþQLFHNRQHNWRUML Plug-and-socket devices.
Connectors
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD EN 61076-3-110
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2016
ICS 31.220.10 Supersedes EN 61076-3-110:2012
English Version
Connectors for electronic equipment - Product requirements -
Part 3-110: Detail specification for free and fixed connectors for
data transmission with frequencies up to 3 000 MHz
(IEC 61076-3-110:2016)
Connecteurs pour équipements électroniques - Exigences Steckverbinder für elektronische Einrichtungen -
de produit - Partie 3-110: Spécification particulière pour les Produktanforderungen - Teil 3-110: Bauartspezifikation für
fiches et les embases pour la transmission de données à freie und feste Steckverbinder für Datenübertragungen bis 3
des fréquences jusqu'à 3 000 MHz 000 MHz
(IEC 61076-3-110:2016) (IEC 61076-3-110:2016)
This European Standard was approved by CENELEC on 2016-10-04. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 61076-3-110:2016 E
European foreword
The text of document 48B/2496/FDIS, future edition 3 of IEC 61076-3-110, prepared by
SC 48B “Electrical connectors” of IEC/TC 48 “Electrical connectors and mechanical structures for
electrical and electronic equipment" was submitted to the IEC-CENELEC parallel vote and approved
by CENELEC as EN 61076-3-110:2016.
The following dates are fixed:
• latest date by which the document has to be (dop) 2017-07-04
implemented at national level by
publication of an identical national
standard or by endorsement
(dow) 2019-10-04
• latest date by which the national
standards conflicting with the
document have to be withdrawn
This document supersedes EN 61076-3-110:2012.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
Endorsement notice
The text of the International Standard IEC 61076-3-110:2016 was approved by CENELEC as a
European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60068-2-38 NOTE Harmonized as EN 60068-2-38.
IEC 60603-7-81:2015 NOTE Harmonized as EN 60603-7-81:2016 (not modified).
IEC 61076 Series NOTE Harmonized as EN 61076 Series.
IEC 61076-3:2008 NOTE Harmonized as EN 61076-3:2008 (not modified).
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.
NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Publication Year Title EN/HD Year
IEC 60068-1 - Environmental testing - EN 60068-1 -
Part 1: General and guidance
IEC 60512 Series Connectors for electronic equipment - EN 60512 Series
Tests and measurements
IEC 60512-1 - Connectors for electronic equipment - EN 60512-1 -
Tests and measurements -
Part 1: General
IEC 60512-25-9 - Connectors for electronic equipment - EN 60512-25-9 -
Tests and measurements -
Part 25-9: Signal integrity tests - Test 25i:
Alien crosstalk
IEC 60512-28-100 - Connectors for electronic equipment - EN 60512-28-100 -
Tests and measurements -
Part 28-100: Signal integrity tests up to
1 000 MHz on IEC 60603-7 and IEC
61076-3 series connectors - Tests 28a to
28g
IEC 60603-7 - Connectors for electronic equipment - EN 60603-7 -
Part 7: Detail specification for 8-way,
unshielded, free and fixed connectors
IEC 60603-7-1 - Connectors for electronic equipment - EN 60603-7-1 -
Part 7-1: Detail specification for 8-way,
shielded, free and fixed connectors
IEC 60603-7-7 2010 Connectors for electronic equipment - EN 60603-7-7 2010
Part 7-7: Detail specification for 8-way,
shielded, free and fixed connectors for data
transmission with frequencies up to 600
MHz
IEC 60603-7-71 - Connectors for electronic equipment - EN 60603-7-71 -
Part 7-71: Detail specification for 8-way,
shielded, free and fixed connectors, for
data transmission with frequencies up to
1000 MHz
Publication Year Title EN/HD Year
1)
IEC 60603-7-82 2016 Connectors for electronic equipment - EN 60603-7-82 201X
Part 7-82: Detail specification for 8-way,
12 contacts, shielded, free and fixed
connectors, for data transmission with
frequencies up to 2 000 MHz
IEC 61076-1 - Connectors for electronic equipment - EN 61076-1 -
Product requirements -
Part 1: Generic specification
IEC 62153-4-15 2015 Metallic communication cable test methods - -
- Part 4-15: Electromagnetic compatibility
(EMC) - Test method for measuring
transfer impedance and screening
attenuation - or coupling attenuation with
triaxial cell
1)
To be published.
IEC 61076-3-110 ®
Edition 3.0 2016-08
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Connectors for electronic equipment – Product requirements –
Part 3-110: Detail specification for free and fixed connectors for data
transmission with frequencies up to 3 000 MHz
Connecteurs pour équipements électroniques – Exigences de produit –
Partie 3-110: Spécification particulière pour les fiches et les embases pour la
transmission de données à des fréquences jusqu’à 3 000 MHz
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 31.220.10 ISBN 978-2-8322-3557-7
– 2 – IEC 61076-3-110:2016 © IEC 2016
CONTENTS
FOREWORD . 4
INTRODUCTION . 6
1 Scope . 7
2 Normative references. 7
3 Terms and definitions . 8
4 Common features and isometric view . 9
4.1 General . 9
4.2 Cable terminations and internal connections – Fixed and free connectors . 10
4.3 Mating information . 10
4.4 Mounting information . 10
5 Gauges . 11
6 Characteristics . 11
6.1 General . 11
6.2 Classification into climate categories, clearance and creepage distances and
current carrying capacity . 11
6.3 Electrical characteristics . 11
6.4 Transmission characteristics . 11
6.4.1 General . 11
6.4.2 Insertion loss (IL) . 11
6.4.3 Return loss (RL) . 11
6.4.4 Propagation delay . 12
6.4.5 Delay skew . 12
6.4.6 Near-end crosstalk (NEXT) . 12
6.4.7 Power sum NEXT (PSNEXT) (for information only) . 12
6.4.8 Far-end crosstalk (FEXT) . 12
6.4.9 Power sum FEXT (PSFEXT) (for information only) . 12
6.4.10 Transverse conversion loss (TCL) . 12
6.4.11 Transverse conversion transfer loss (TCTL) . 12
6.4.12 Power sum alien (exogenous) NEXT (PSANEXT) . 13
6.4.13 Power sum alien (exogenous) FEXT (PSAFEXT) . 13
6.4.14 Coupling attenuation . 13
6.5 Mechanical characteristics . 13
7 Test schedule . 13
7.1 General . 13
7.2 Test schedule . 14
7.2.1 Test group EP . 14
Annex A (normative) Gauging requirements . 15
A.1 Fixed connectors . 15
A.2 Free connectors . 15
Bibliography . 16
Figure 1 – Isometric view of fixed cable connector and free 4, 6 and 2 pair connectors,
examples . 9
Figure 2 – Isometric view of fixed board connector, example . 10
IEC 61076-3-110:2016 © IEC 2016 – 3 –
Figure 3 – Fixed connector pin numbering assignments (front view of connector),
example .
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.