Determination of power losses in high-voltage direct current (HVDC) converter stations with line-commutated converters

Applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange in utility systems. Presumes the use of 12-pulse thyristor converters but can also be used for 6-pulse thyristor converters. Presents procedures for determining the total losses of an HVDC converter station. Cover all parts, except synchronous compensators or static var compensators and address no-load operation and operating losses together with their methods of calculation which use, wherever possible, measured parameters.

Bestimmung der Leistungsverluste in Hochspannungsgleichstrom- (HGÜ-)Stromrichterstationen mit netzgeführten Stromrichtern

Détermination des pertes en puissance dans les postes de conversion en courant continu à haute tension (CCHT) munis de convertisseurs commutés par le réseau

S'applique à tous les postes de conversion en courant continu à haute tnesion (CCHT), commutés par le réseau, et utilisés pour l'échange de puissance dans des systèmes de distribution d'énergie. Présuppose l'utilisation de convertisseurs à thyristors à 12 impulsions mais peut également s'appliquer à des convertisseurs à thyristors à 6 impulsions. Décrit un ensemble de procédures types permettant de déterminer l'ensemble des pertes d'un poste de conversion à CCHT. Les procédures recouvrent toutes les pièces, à l'exception des compensateurs synchrones ou des compensateurs var statiques et considèrent les pertes en fonctionnement à vide et les pertes en fonctionnement ainsi que leurs méthodes de calcul utilisant, dans la mesure du possible, des paramètres mesurés.

Determination of power losses in high-voltage direct current (HVDC) converter stations (IEC 61803:1999)

Velja za vse vodovno komutirane visokonapetostne enosmerne (HVDC) pretvornike, ki se uporabljajo za izmenjavo električne energije v javnih sistemih. Ta standard predvideva uporabo 12-pulznih tiristorksih pretvornikov, vendar se lahko uporablja tudi za 6-pulzne tiristorske pretvornike ob ustrezni previdnosti.

General Information

Status
Withdrawn
Publication Date
31-Mar-1999
Withdrawal Date
31-Mar-2002
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
23-Nov-2023
Completion Date
23-Nov-2023

Relations

Buy Standard

Standard
EN 61803:2001
English language
36 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-junij-2001
Determination of power losses in high-voltage direct current (HVDC) converter
stations (IEC 61803:1999)
Determination of power losses in high-voltage direct current (HVDC) converter stations
Bestimmung der Leistungsverluste in Hochspannungsgleichstrom- (HGÜ-)
Stromrichterstationen
Détermination des pertes en puissance dans les postes de conversion en courant
continu à haute tension (CCHT)
Ta slovenski standard je istoveten z: EN 61803:1999
ICS:
29.200 8VPHUQLNL3UHWYRUQLNL Rectifiers. Convertors.
6WDELOL]LUDQRHOHNWULþQR Stabilized power supply
QDSDMDQMH
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.